  • 1,085Number of bridges
  • 12,034ft / 3,668mTotal length
  • $82,595,000Total costs
  • 55,047,582Total average daily traffic
  • 3,107,918Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Detroit
  • No street view available for this location

New bridges in Detroit, MI - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 371900-1909
  • 431910-1919
  • 371920-1929
  • 331930-1939
  • 291940-1949
  • 2071950-1959
  • 2591960-1969
  • 2551970-1979
  • 361980-1989
  • 131990-1999
  • 762000-2009
  • 462010-2019
  • 132020-2022
Reconstructed bridges in Detroit, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 31960-1969
  • 51970-1979
  • 221980-1989
  • 1161990-1999
  • 852000-2009
  • 272010-2019
Average Bridge Truck Traffic in Detroit, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 2.5%Excellent
  • 14.0%Very good
  • 41.7%Good
  • 25.6%Satisfactory
  • 10.8%Fair
  • 4.4%Poor
  • 1.0%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 2.3%Excellent
  • 15.1%Very good
  • 44.2%Good
  • 22.8%Satisfactory
  • 11.6%Fair
  • 3.5%Poor
  • 0.4%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 2.1%Excellent
  • 10.0%Very good
  • 41.9%Good
  • 30.9%Satisfactory
  • 12.2%Fair
  • 2.5%Poor
  • 0.4%Serious
  • 0.2%Failed
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 15.5%Very good
  • 30.9%Good
  • 25.5%Satisfactory
  • 22.7%Fair
  • 4.5%Poor
  • 0.9%Serious
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 5.0%Excellent
  • 40.0%Very good
  • 20.0%Satisfactory
  • 25.0%Fair
  • 5.0%Poor
  • 5.0%Serious
Find on map >>   Show street view

Structure Number: 11256,  Location: IN DETROIT (Lat: 42.409092,  Lng: -82.948208),  Route carried "on" structure: City street 2000,  Year Built: 1959,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 7.86m (25.79ft),  Average Daily Traffic: 9,250 (year 1978),  Truck Traffic: 3%,  Average Future Daily Traffic: 13,300 (year 2017),  Design Load: HS 20,  Features Intersected: I-94,  Facility Carried by Structure: HARPER AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.110,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 21.3m (69.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 64.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11257,  Location: IN DETROIT (Lat: 42.412861,  Lng: -82.943211),  Route carried "on" structure: City street 2000,  Year Built: 1959,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 5.15m (16.90ft),  Average Daily Traffic: 12,173 (year 2010),  Average Future Daily Traffic: 13,390 (year 2025),  Design Load: HS 20,  Features Intersected: I-94,  Facility Carried by Structure: WHITTIER RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.453,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.3m (56.8ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 86.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11258,  Location: IN DETROIT (Lat: 42.417208,  Lng: -82.937139),  Route carried "on" structure: City street 2000,  Year Built: 1959,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 5.15m (16.90ft),  Average Daily Traffic: 15,233 (year 2010),  Truck Traffic: 3%,  Average Future Daily Traffic: 16,756 (year 2025),  Design Load: HS 20,  Features Intersected: I-94,  Facility Carried by Structure: CADIEUX AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.410,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.0m (55.8ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 21.9m (71.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 86.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11259,  Location: IN DETROIT (Lat: 42.419250,  Lng: -82.933450),  Route carried "on" structure: City street ,  Year Built: 1959,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 5.03m (16.50ft),  Average Daily Traffic: 4,385 (year 2010),  Average Future Daily Traffic: 4,824 (year 2025),  Design Load: HS 20,  Features Intersected: I-94,  Facility Carried by Structure: MORANG AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.084,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 16.7m (54.8ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 63.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 1126,  Location: IN DETROIT (Lat: 42.420308,  Lng: -82.932122),  Route carried "on" structure: City street ,  Year Built: 1959,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 7.07m (23.20ft),  Average Daily Traffic: 5,948 (year 2010),  Average Future Daily Traffic: 6,543 (year 2025),  Design Load: HS 20,  Features Intersected: I-94,  Facility Carried by Structure: HARPER AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.230,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.0m (78.7ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 80.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11261,  Location: IN DETROIT (Lat: 42.424764,  Lng: -82.928442),  Route carried "on" structure: County highway 2057,  Year Built: 2003,  Status: Open,  Structure Length: 4.98m (16.34ft),  Average Daily Traffic: 20,000 (year 2003),  Truck Traffic: 3%,  Average Future Daily Traffic: 23,000 (year 2023),  Design Load: HS 25 or greater,  Features Intersected: I-94,  Facility Carried by Structure: MOROSS RD NB
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.974,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 163,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.9m (81.7ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 21.2m (69.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 87.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11262,  Location: IN DETROIT (Lat: 42.424386,  Lng: -82.928739),  Route carried "on" structure: County highway 2057,  Year Built: 2003,  Status: Open,  Structure Length: 4.98m (16.34ft),  Average Daily Traffic: 17,085 (year 2010),  Truck Traffic: 3%,  Average Future Daily Traffic: 18,794 (year 2025),  Design Load: HS 25 or greater,  Features Intersected: I-94,  Facility Carried by Structure: MOROSS RD SB
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.815,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 470,  Subroute: 19),  Owner: State Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.9m (81.7ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 21.2m (69.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11292,  Location: 0.1 MI S OF M-102 (Lat: 42.441442,  Lng: -83.278644),  Route carried "on" structure: US 24,  Year Built: 1967,  Status: Open,  Structure Length: 2.53m (8.30ft),  Average Daily Traffic: 63,820 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 76,808 (year 2018),  Design Load: HS 20,  Features Intersected: ROUGE RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 39.178,  Lanes on structure: 10,  Base Highway Network: Yes (Inventory Route: 470,  Subroute: 38),  Owner: State Highway Agency,  Approaching Roadway Width: 39.0m (128.0ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.3m (83.0ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 43.2m (141.7ft),  Out-to-Out Width: 45.8m (150.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 78.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Other Special Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 11316,  Location: IN DETROIT (Lat: 42.331147,  Lng: -83.101242),  Route carried "on" structure: City street ,  Year Built: 1941,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 4.39m (14.40ft),  Average Daily Traffic: 7,350 (year 1978),  Average Future Daily Traffic: 7,350 (year 1977),  Design Load: H 20,  Features Intersected: US-12,  Facility Carried by Structure: SCOTTEN AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.073,  Lanes on structure: 4,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 21.9m (71.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 19.1m (62.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Operating Rating: 81.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Critical Feature Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11326,  Location: IN DETROIT (Lat: 42.347278,  Lng: -83.035844),  Route carried "on" structure: State highway 3,  Year Built: 1929,  Year Reconstructed: 1970,  Status: Open,  Structure Length: 2.59m (8.50ft),  Average Daily Traffic: 19,649 (year 2007),  Truck Traffic: 6%,  Average Future Daily Traffic: 20,529 (year 2018),  Design Load: H 20,  Features Intersected: DEQUINDRE CUT
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.841,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 470,  Subroute: 42),  Owner: State Highway Agency,  Approaching Roadway Width: 27.4m (89.9ft),  Skew: 23 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 2.9m (9.5ft),  Right: 2.9m (9.5ft),  Curb-To-Curb Width: 27.4m (89.9ft),  Out-to-Out Width: 36.5m (119.8ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Membrane: Other
Find on map >>   Show street view

Structure Number: 11377,  Location: IN DETROIT O S SERVICE RD (Lat: 42.407103,  Lng: -83.083917),  Route carried "on" structure: Ramp State highway 8,  Year Built: 1971,  Status: Open,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 4,360 (year 1982),  Truck Traffic: 7%,  Average Future Daily Traffic: 5,014 (year 2002),  Design Load: HS 20,  Features Intersected: S SERVICE DRIVE, M-8
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.351,  Lanes on structure: 3,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 31.6m (103.7ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.0m,  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Good,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Other Special Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 11378,  Location: IN DETROIT M-8 WB RAMP (Lat: 42.408236,  Lng: -83.083486),  Route carried "on" structure: ServiceState highway 8,  Year Built: 1971,  Status: Open,  Structure Length: 3.72m (12.20ft),  Average Daily Traffic: 3,180 (year 1982),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,657 (year 2002),  Design Load: HS 20,  Features Intersected: I-75 RAMP TO WB M-8,  Facility Carried by Structure: N SERVICE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.962,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 37.2m (122.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 1.9m (6.2ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 11.7m (38.4ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 91.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 54.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 11379,  Location: IN DETROIT (Lat: 42.413131,  Lng: -83.068839),  Route carried "on" structure: City street 2000,  Year Built: 1971,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 5.18m (16.99ft),  Average Daily Traffic: 17,760 (year 1970),  Truck Traffic: 3%,  Average Future Daily Traffic: 17,760 (year 1977),  Design Load: HS 20,  Features Intersected: M-8,  Facility Carried by Structure: JOSEPH CAMPAU
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.360,  Lanes on structure: 4,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 17.9m (58.7ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 25.9m (85.0ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 24.8m (81.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 71.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Bridge Improvement Cost: $144,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1138,  Location: IN DETROIT (Lat: 42.410767,  Lng: -83.072833),  Route carried "on" structure: City street ,  Year Built: 1971,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 6.60m (21.65ft),  Average Daily Traffic: 2,500 (year 1990),  Average Future Daily Traffic: 2,875 (year 2010),  Design Load: HS 20,  Features Intersected: M-8,  Facility Carried by Structure: GODDARD AVENUE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.755,  Lanes on structure: 2,  Lanes under structure: 10,  Owner: State Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 39.9m (130.9ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 83.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1139,  Location: IN DETROIT (Lat: 42.336706,  Lng: -83.038397),  Route carried "on" structure: City street 2000,  Year Built: 1959,  Year Reconstructed: 1996,  Status: Open,  Structure Length: 5.54m (18.18ft),  Average Daily Traffic: 7,000 (year 1996),  Average Future Daily Traffic: 7,700 (year 2015),  Design Load: HS 20,  Features Intersected: I-375,  Facility Carried by Structure: MONROE AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.853,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 1.0m (3.3ft),  Right: 3.3m (10.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 46.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11391,  Location: IN DETROIT (Lat: 42.335675,  Lng: -83.037733),  Route carried "on" structure: City street 2000,  Year Built: 1960,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 5.64m (18.50ft),  Average Daily Traffic: 5,090 (year 0000),  Average Future Daily Traffic: 1,300 (year 2010),  Design Load: HS 25 or greater,  Features Intersected: I-375,  Facility Carried by Structure: LAFAYETTE AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.600,  Lanes on structure: 6,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 3.3m (10.8ft),  Right: 3.3m (10.8ft),  Curb-To-Curb Width: 27.4m (89.9ft),  Out-to-Out Width: 34.7m (113.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 52.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11392,  Location: IN DETROIT (Lat: 42.333347,  Lng: -83.036158),  Route carried "on" structure: City street 2000,  Year Built: 1960,  Status: Open,  Structure Length: 5.07m (16.63ft),  Average Daily Traffic: 9,000 (year 1978),  Average Future Daily Traffic: 9,000 (year 2010),  Design Load: HS 20+Mod,  Features Intersected: I-375,  Facility Carried by Structure: LARNED ST
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.627,  Lanes on structure: 5,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 23.4m (76.8ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 16.2m (53.1ft),  Curb or Sidewalk Widths: Left: 3.7m (12.1ft),  Right: 3.7m (12.1ft),  Curb-To-Curb Width: 27.4m (89.9ft),  Out-to-Out Width: 34.7m (113.8ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Poor,  Operating Rating: 55.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 6 months,  Inspection Date: June 2020,  Other Special Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 11393,  Location: IN DETROIT (Lat: 42.332592,  Lng: -83.035886),  Route carried "on" structure: City street 2000,  Year Built: 1962,  Status: Open,  Structure Length: 4.17m (13.68ft),  Average Daily Traffic: 42,800 (year 2007),  Average Future Daily Traffic: 47,080 (year 2022),  Design Load: HS 20+Mod,  Features Intersected: I-375,  Facility Carried by Structure: JEFFERSON AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.309,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 21.6m (70.9ft),  Curb or Sidewalk Widths: Left: 4.6m (15.1ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Operating Rating: 71.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 11394,  Location: IN DETROIT (Lat: 42.332258,  Lng: -83.035994),  Route carried "on" structure: City street ,  Year Built: 1962,  Status: Open,  Structure Length: 3.40m (11.15ft),  Average Daily Traffic: 4,220 (year 1988),  Average Future Daily Traffic: 4,220 (year 2016),  Design Load: HS 20+Mod,  Features Intersected: I-375,  Facility Carried by Structure: CHRYSLER DR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.031,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.0m (32.8ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 17.0m (55.8ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 4.6m (15.1ft),  Curb-To-Curb Width: 18.2m (59.7ft),  Out-to-Out Width: 21.0m (68.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 65.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 6 months,  Inspection Date: June 2020,  Other Special Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 11395,  Location: IN DETROIT (Lat: 42.327158,  Lng: -83.047847),  Route carried "on" structure: City street 2000,  Year Built: 1958,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 3.13m (10.27ft),  Average Daily Traffic: 2,500 (year 2004),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,000 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: M-10,  Facility Carried by Structure: WASHINGTON ST
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.042,  Lanes on structure: 6,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 15.8m (51.8ft),  Curb or Sidewalk Widths: Left: 6.8m (22.3ft),  Right: 6.0m (19.7ft),  Curb-To-Curb Width: 48.0m (157.5ft),  Out-to-Out Width: 52.8m (173.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 85.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 50.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 11396,  Location: IN DETROIT (Lat: 42.326439,  Lng: -83.051972),  Route carried "on" structure: Ramp State highway 10,  Year Built: 1959,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 3.11m (10.20ft),  Average Daily Traffic: 7,626 (year 2010),  Average Future Daily Traffic: 8,389 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: M-10 NB,  Facility Carried by Structure: LARNED ST RAMP
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.119,  Lanes on structure: 1,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.1m (16.7ft),  Skew: 6 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 31.1m (102.0ft),  Curb-To-Curb Width: 11.2m (36.7ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 65.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: High priority of corrective action,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11397,  Location: IN DETROIT (Lat: 42.327200,  Lng: -83.055556),  Route carried "on" structure: State highway 85,  Year Built: 1958,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 3.36m (11.02ft),  Average Daily Traffic: 10,191 (year 2007),  Truck Traffic: 32%,  Average Future Daily Traffic: 10,357 (year 2018),  Design Load: HS 20,  Features Intersected: M-10
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.306,  Lanes on structure: 6,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 158,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 16.7m (54.8ft),  Curb or Sidewalk Widths: Left: 4.6m (15.1ft),  Right: 4.2m (13.8ft),  Curb-To-Curb Width: 22.1m (72.5ft),  Out-to-Out Width: 30.9m (101.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 70.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $56,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11398,  Location: IN DETROIT (Lat: 42.327886,  Lng: -83.056658),  Route carried "on" structure: City street ,  Year Built: 1952,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 3.56m (11.68ft),  Average Daily Traffic: 12,860 (year 1978),  Truck Traffic: 2%,  Average Future Daily Traffic: 12,860 (year 1977),  Design Load: HS 20,  Features Intersected: M-10,  Facility Carried by Structure: LAFAYETTE BLVD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.856,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 17.8m (58.4ft),  Curb or Sidewalk Widths: Left: 4.5m (14.8ft),  Right: 4.5m (14.8ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 24.9m (81.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 48.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 28.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 11399,  Location: IN DETROIT (Lat: 42.328564,  Lng: -83.057661),  Route carried "on" structure: City street ,  Year Built: 1953,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 3.60m (11.81ft),  Average Daily Traffic: 16,480 (year 1978),  Average Future Daily Traffic: 16,480 (year 2000),  Design Load: HS 20,  Features Intersected: M-10,  Facility Carried by Structure: HOWARD ST
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.954,  Lanes on structure: 3,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 18.0m (59.1ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 18.9m (62.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 71.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 114,  Location: IN DETROIT (Lat: 42.331586,  Lng: -83.061181),  Route carried "on" structure: US 12,  Year Built: 1954,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 1.94m (6.36ft),  Average Daily Traffic: 12,806 (year 2007),  Truck Traffic: 11%,  Average Future Daily Traffic: 10,630 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: M-10 NB
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.936,  Lanes on structure: 9,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 157,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 27.4m (89.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.4m (63.6ft),  Curb or Sidewalk Widths: Left: 4.9m (16.1ft),  Right: 4.9m (16.1ft),  Curb-To-Curb Width: 27.4m (89.9ft),  Out-to-Out Width: 37.2m (122.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 76.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 47.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Other Special Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11401,  Location: IN DETROIT (Lat: 42.331550,  Lng: -83.061883),  Route carried "on" structure: US 12,  Year Built: 1954,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 2.00m (6.56ft),  Average Daily Traffic: 9,034 (year 2007),  Truck Traffic: 13%,  Average Future Daily Traffic: 9,416 (year 2018),  Design Load: HS 20,  Features Intersected: M-10 SB
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.878,  Lanes on structure: 9,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 157,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 27.4m (89.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.0m (65.6ft),  Curb or Sidewalk Widths: Left: 4.9m (16.1ft),  Right: 4.9m (16.1ft),  Curb-To-Curb Width: 27.4m (89.9ft),  Out-to-Out Width: 37.2m (122.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 74.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Other Special Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11402,  Location: IN DETROIT (Lat: 42.331850,  Lng: -83.061481),  Route carried "on" structure: Ramp US 12,  Year Built: 1954,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 2.37m (7.78ft),  Average Daily Traffic: 8,000 (year 1982),  Truck Traffic: 3%,  Average Future Daily Traffic: 9,200 (year 2002),  Design Load: HS 20,  Features Intersected: M-10,  Facility Carried by Structure: BAGLEY AV RAMPS
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.385,  Lanes on structure: 4,  Lanes under structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 27.4m (89.9ft),  Skew: 24 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.7m (77.8ft),  Curb-To-Curb Width: 23.7m (77.8ft),  Out-to-Out Width: 24.6m (80.7ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 73.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 11403,  Location: IN DETROIT (Lat: 42.339167,  Lng: -83.066114),  Route carried "on" structure: Business Interstate 96,  Year Built: 1953,  Year Reconstructed: 1996,  Status: Open,  Structure Length: 4.90m (16.08ft),  Average Daily Traffic: 8,109 (year 2007),  Truck Traffic: 6%,  Average Future Daily Traffic: 20,049 (year 2018),  Design Load: HS 20,  Features Intersected: M-10,  Facility Carried by Structure: GRAND RIVER AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 18.638,  Lanes on structure: 10,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 157,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 24 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.7m (81.0ft),  Curb or Sidewalk Widths: Left: 1.0m (3.3ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 48.9m (160.4ft),  Out-to-Out Width: 49.5m (162.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 48.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Critical Feature Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 11404,  Location: IN DETROIT (Lat: 42.343225,  Lng: -83.068011),  Route carried "on" structure: City street ,  Year Built: 2017,  Status: Open,  Structure Length: 4.54m (14.90ft),  Average Daily Traffic: 8,565 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 9,095 (year 2038),  Design Load: Greater than HL93,  Features Intersected: M-10,  Facility Carried by Structure: MLK JR BLVD EB
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.580,  Lanes on structure: 2,  Lanes under structure: 7,  Base Highway Network: Yes (Inventory Route: 470,  Subroute: 71),  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 22.7m (74.5ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.2m (10.5ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 17.8m (58.4ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Very good,  Operating Rating: 61.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11405,  Location: IN DETROIT (Lat: 42.351625,  Lng: -83.072083),  Route carried "on" structure: City street 2000,  Year Built: 1950,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 3.38m (11.09ft),  Average Daily Traffic: 13,670 (year 0000),  Truck Traffic: 3%,  Average Future Daily Traffic: 118,200 (year 2014),  Design Load: HS 20,  Features Intersected: M-10,  Facility Carried by Structure: FOREST AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.194,  Lanes on structure: 6,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 158,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 16.7m (54.8ft),  Curb or Sidewalk Widths: Left: 1.0m (3.3ft),  Right: 1.0m (3.3ft),  Curb-To-Curb Width: 23.8m (78.1ft),  Out-to-Out Width: 31.4m (103.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 70.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Other Special Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11406,  Location: IN DETROIT (Lat: 42.353769,  Lng: -83.073392),  Route carried "on" structure: City street 2000,  Year Built: 1950,  Year Reconstructed: 1996,  Status: Open,  Structure Length: 3.86m (12.66ft),  Average Daily Traffic: 26,900 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 29,590 (year 2022),  Design Load: HS 20,  Features Intersected: M-10,  Facility Carried by Structure: WARREN AV
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.462,  Lanes on structure: 10,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 470,  Subroute: 29),  Owner: State Highway Agency,  Approaching Roadway Width: 30.5m (100.1ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 18.6m (61.0ft),  Curb or Sidewalk Widths: Left: 4.2m (13.8ft),  Right: 4.2m (13.8ft),  Curb-To-Curb Width: 33.5m (109.9ft),  Out-to-Out Width: 42.6m (139.8ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 72.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Other Special Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11407,  Location: IN CITY OF DETROIT (Lat: 42.325717,  Lng: -83.053119),  Route carried "on" structure: Ramp State highway 10,  Year Built: 1980,  Status: Open,  Structure Length: 25.06m (82.22ft),  Average Daily Traffic: 550 (year 1988),  Truck Traffic: 2%,  Average Future Daily Traffic: 500 (year 1977),  Design Load: HS 25 or greater,  Features Intersected: JEFFERSON AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.138,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 11,  Length of Maximum Span: 33.2m (108.9ft),  Curb-To-Curb Width: 11.7m (38.4ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 52.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 11408,  Location: IN CITY OF DETROIT (Lat: 42.326178,  Lng: -83.052139),  Route carried "on" structure: State highway 10,  Year Built: 1987,  Status: Open,  Structure Length: 2.50m (8.20ft),  Average Daily Traffic: 37,039 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 45,104 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: WB JEFFERSON AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 19.660,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 157,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.0m (82.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 82.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11426,  Location: IN DETROIT (Lat: 42.365983,  Lng: -83.080892),  Route carried "on" structure: City street ,  Year Built: 1949,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 3.38m (11.09ft),  Average Daily Traffic: 14,000 (year 1993),  Average Future Daily Traffic: 21,000 (year 2015),  Design Load: HS 20,  Features Intersected: M-10,  Facility Carried by Structure: MILWAUKEE AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.166,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 16.7m (54.8ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 21.1m (69.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11427,  Location: IN DETROIT (Lat: 42.367025,  Lng: -83.081672),  Route carried "on" structure: City street 2000,  Year Built: 1950,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 3.40m (11.15ft),  Average Daily Traffic: 29,000 (year 1993),  Truck Traffic: 4%,  Average Future Daily Traffic: 29,000 (year 2013),  Design Load: HS 20,  Features Intersected: M-10,  Facility Carried by Structure: W GRAND BOULEVARD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.768,  Lanes on structure: 9,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 16.6m (54.5ft),  Curb or Sidewalk Widths: Left: 1.0m (3.3ft),  Right: 6.0m (19.7ft),  Curb-To-Curb Width: 30.4m (99.7ft),  Out-to-Out Width: 48.8m (160.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 66.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11428,  Location: IN DETROIT (Lat: 42.370264,  Lng: -83.083814),  Route carried "on" structure: City street ,  Year Built: 1954,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 4.22m (13.85ft),  Average Daily Traffic: 8,660 (year 1978),  Average Future Daily Traffic: 8,660 (year 1998),  Design Load: HS 20,  Features Intersected: M-10,  Facility Carried by Structure: PALLISTER AVENUE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.829,  Lanes on structure: 4,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 21.1m (69.2ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.7m (12.1ft),  Curb-To-Curb Width: 15.3m (50.2ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 71.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.24m (13.91ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $33,000,  Roadway Improvement Cost: $3,000,  Total Project Cost: $38,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing