Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Detroit, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 1,085Number of bridges
  • 12,034ft / 3,668mTotal length
  • $82,595,000Total costs
  • 55,047,582Total average daily traffic
  • 3,107,918Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Detroit
  • No street view available for this location

New bridges in Detroit, MI - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 371900-1909
  • 431910-1919
  • 371920-1929
  • 331930-1939
  • 291940-1949
  • 2071950-1959
  • 2591960-1969
  • 2551970-1979
  • 361980-1989
  • 131990-1999
  • 762000-2009
  • 462010-2019
  • 132020-2022
Reconstructed bridges in Detroit, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 31960-1969
  • 51970-1979
  • 221980-1989
  • 1161990-1999
  • 852000-2009
  • 272010-2019
Average Bridge Truck Traffic in Detroit, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 2.5%Excellent
  • 14.0%Very good
  • 41.7%Good
  • 25.6%Satisfactory
  • 10.8%Fair
  • 4.4%Poor
  • 1.0%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 2.3%Excellent
  • 15.1%Very good
  • 44.2%Good
  • 22.8%Satisfactory
  • 11.6%Fair
  • 3.5%Poor
  • 0.4%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 2.1%Excellent
  • 10.0%Very good
  • 41.9%Good
  • 30.9%Satisfactory
  • 12.2%Fair
  • 2.5%Poor
  • 0.4%Serious
  • 0.2%Failed
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 15.5%Very good
  • 30.9%Good
  • 25.5%Satisfactory
  • 22.7%Fair
  • 4.5%Poor
  • 0.9%Serious
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 5.0%Excellent
  • 40.0%Very good
  • 20.0%Satisfactory
  • 25.0%Fair
  • 5.0%Poor
  • 5.0%Serious
Find on map >>   Show street view

Structure Number: 11218,  Location: IN DETROIT (Lat: 42.383344,  Lng: -83.029839),  Route carried "under" structure: Interstate 94,  Year Built: 2019,  Structure Length: 0. m,  Average Daily Traffic: 142,650 (year 2017),  Truck Traffic: 5%,  Features Intersected: I-94,  Facility Carried by Structure: CONCORD AVE
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 48.992,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.9m (114.5ft)

Find on map >>   Show street view

Structure Number: 1122,  Location: IN DETROIT (Lat: 42.386153,  Lng: -83.020078),  Route carried "under" structure: Interstate 94,  Year Built: 2013,  Structure Length: 0. m,  Average Daily Traffic: 147,000 (year 2012),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: M-53(VANDYKE ST)
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 49.864,  Lanes on structure: 6,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 11222,  Location: IN DETROIT (Lat: 42.390858,  Lng: -83.008125),  Route carried "under" structure: Interstate 94,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 157,788 (year 2007),  Truck Traffic: 5%,  Features Intersected: I-94,  Facility Carried by Structure: MCCLELLAN AVE
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 50.978,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.5m (80.4ft)

Find on map >>   Show street view

Structure Number: 11223,  Location: IN DETROIT (Lat: 42.380911,  Lng: -83.031942),  Route carried "under" structure: Interstate 94,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 166,726 (year 2007),  Truck Traffic: 5%,  Features Intersected: I-94,  Facility Carried by Structure: HARPER AVE
Minimum Vertical Clearance: 5.31m (17.42ft),  Kilometerpoint: 48.670,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.5m (86.9ft)

Find on map >>   Show street view

Structure Number: 11224,  Location: CITY OF DETROIT (Lat: 42.373922,  Lng: -83.048900),  Route carried "under" structure: City street 2000,  Year Built: 1983,  Structure Length: 0. m,  Average Daily Traffic: 1,500 (year 1982),  Features Intersected: E BD E GRAND BLVD,  Facility Carried by Structure: CHENE RAMP TO I-94
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.638,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.1m (98.8ft)

Find on map >>   Show street view

Structure Number: 11225,  Location: IN DETROIT (Lat: 42.377111,  Lng: -83.038442),  Route carried "under" structure: Interstate 94,  Year Built: 1983,  Structure Length: 0. m,  Average Daily Traffic: 154,114 (year 2007),  Truck Traffic: 4%,  Features Intersected: I-94,  Facility Carried by Structure: LUCKY PLACE
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 47.973,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>   Show street view

Structure Number: 11226,  Location: IN DETROIT (Lat: 42.378547,  Lng: -83.034897),  Route carried "under" structure: Interstate 94,  Year Built: 1983,  Structure Length: 0. m,  Average Daily Traffic: 154,114 (year 2007),  Truck Traffic: 4%,  Features Intersected: I-94,  Facility Carried by Structure: SAGINAW ST U-TRN
Minimum Vertical Clearance: 5.16m (16.93ft),  Kilometerpoint: 48.308,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>   Show street view

Structure Number: 11227,  Location: IN DETROIT (Lat: 42.381817,  Lng: -83.031303),  Route carried "under" structure: Interstate 94,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 166,726 (year 2007),  Truck Traffic: 5%,  Features Intersected: I-94,  Facility Carried by Structure: CONRAIL
Minimum Vertical Clearance: 4.29m (14.07ft),  Kilometerpoint: 48.784,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.2m (59.7ft)

Find on map >>   Show street view

Structure Number: 1123,  Location: IN DETROIT (Lat: 42.397461,  Lng: -82.985933),  Route carried "under" structure: Interstate 94,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: MALCOLM AVE WALKOV
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 53.030,  Lanes under structure: 8,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 20.4m (66.9ft)

Find on map >>   Show street view

Structure Number: 11231,  Location: IN DETROIT (Lat: 42.402119,  Lng: -82.970072),  Route carried "under" structure: Interstate 94,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: COPLIN AVE WALKOVE
Minimum Vertical Clearance: 4.95m (16.24ft),  Kilometerpoint: 54.438,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 22.2m (72.8ft)

Find on map >>   Show street view

Structure Number: 11232,  Location: IN DETROIT (Lat: 42.403047,  Lng: -82.966594),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: NEWPORT AVE WALKOV
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 54.742,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 23.1m (75.8ft)

Find on map >>   Show street view

Structure Number: 11233,  Location: IN DETROIT (Lat: 42.404381,  Lng: -82.961997),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: PHILIP AVE WALKOVE
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 55.149,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 16.6m (54.5ft)

Find on map >>   Show street view

Structure Number: 11234,  Location: IN DETROIT (Lat: 42.406050,  Lng: -82.956558),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: LAKEPOINTE AV WALK
Minimum Vertical Clearance: 4.82m (15.81ft),  Kilometerpoint: 55.634,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 18.2m (59.7ft)

Find on map >>   Show street view

Structure Number: 11235,  Location: IN DETROIT (Lat: 42.407700,  Lng: -82.950672),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: CHATSWORTH RD WALK
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 56.152,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 17.9m (58.7ft)

Find on map >>   Show street view

Structure Number: 11236,  Location: IN DETROIT (Lat: 42.409997,  Lng: -82.947006),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: BEDFORD RD WALKOVE
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 56.549,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 16.7m (54.8ft)

Find on map >>   Show street view

Structure Number: 11239,  Location: IN DETROIT (Lat: 42.415136,  Lng: -82.940147),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: BISHOP AVE WALKOVE
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 57.351,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 11245,  Location: IN DETROIT (Lat: 42.391539,  Lng: -83.006272),  Route carried "under" structure: Interstate 94,  Year Built: 2018,  Structure Length: 0. m,  Average Daily Traffic: 142,650 (year 2017),  Truck Traffic: 5%,  Features Intersected: I-94,  Facility Carried by Structure: M-3 (GRATIOT)
Minimum Vertical Clearance: 4.67m (15.32ft),  Kilometerpoint: 51.135,  Lanes on structure: 8,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 11247,  Location: IN DETROIT (Lat: 42.392269,  Lng: -82.995839),  Route carried "under" structure: Interstate 94,  Year Built: 2019,  Structure Length: 0. m,  Average Daily Traffic: 142,650 (year 2017),  Truck Traffic: 5%,  Features Intersected: I-94,  Facility Carried by Structure: FRENCH ROAD
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 52.011,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.1m (95.5ft)

Find on map >>   Show street view

Structure Number: 11248,  Location: IN DETROIT (Lat: 42.395461,  Lng: -82.989086),  Route carried "under" structure: Interstate 94,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 148,534 (year 2007),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: SB CONNER AVE
Minimum Vertical Clearance: 4.65m (15.26ft),  Kilometerpoint: 52.684,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.7m (67.9ft)

Find on map >>   Show street view

Structure Number: 11249,  Location: IN DETROIT (Lat: 42.396567,  Lng: -82.987589),  Route carried "under" structure: Interstate 94,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 128,570 (year 2007),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: NB CONNER AVE
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 52.858,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.3m (56.8ft)

Find on map >>   Show street view

Structure Number: 1125,  Location: IN DETROIT (Lat: 42.398414,  Lng: -82.984003),  Route carried "under" structure: Interstate 94,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: BARRETT AVE
Minimum Vertical Clearance: 4.65m (15.26ft),  Kilometerpoint: 53.220,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.3m (56.8ft)

Find on map >>   Show street view

Structure Number: 11251,  Location: IN DETROIT (Lat: 42.401467,  Lng: -82.973028),  Route carried "under" structure: Interstate 94,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: DICKERSON AVE
Minimum Vertical Clearance: 4.37m (14.34ft),  Kilometerpoint: 54.184,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.7m (54.8ft)

Find on map >>   Show street view

Structure Number: 11252,  Location: IN DETROIT (Lat: 42.403706,  Lng: -82.964214),  Route carried "under" structure: Interstate 94,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 7%,  Features Intersected: I-94,  Facility Carried by Structure: CHALMERS AVE
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 54.951,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.7m (54.8ft)

Find on map >>   Show street view

Structure Number: 11253,  Location: IN DETROIT (Lat: 42.405008,  Lng: -82.959967),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: OUTER DRIVE NB
Minimum Vertical Clearance: 4.40m (14.44ft),  Kilometerpoint: 55.330,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.7m (54.8ft)

Find on map >>   Show street view

Structure Number: 11254,  Location: IN DETROIT (Lat: 42.404925,  Lng: -82.960242),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: OUTER DRIVE SB
Minimum Vertical Clearance: 4.40m (14.44ft),  Kilometerpoint: 55.305,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.7m (54.8ft)

Find on map >>   Show street view

Structure Number: 11255,  Location: IN DETROIT (Lat: 42.406761,  Lng: -82.953953),  Route carried "under" structure: Interstate 94,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: NOTTINGHAM RD
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 55.862,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.7m (54.8ft)

Find on map >>   Show street view

Structure Number: 11256,  Location: IN DETROIT (Lat: 42.409092,  Lng: -82.948208),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: HARPER AVE
Minimum Vertical Clearance: 4.82m (15.81ft),  Kilometerpoint: 56.408,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 11257,  Location: IN DETROIT (Lat: 42.412861,  Lng: -82.943211),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: WHITTIER RD
Minimum Vertical Clearance: 4.37m (14.34ft),  Kilometerpoint: 56.995,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.3m (56.8ft)

Find on map >>   Show street view

Structure Number: 11258,  Location: IN DETROIT (Lat: 42.417208,  Lng: -82.937139),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: CADIEUX AVE
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 57.691,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.0m (55.8ft)

Find on map >>   Show street view

Structure Number: 11259,  Location: IN DETROIT (Lat: 42.419250,  Lng: -82.933450),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 7%,  Features Intersected: I-94,  Facility Carried by Structure: MORANG AVE
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 58.069,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.7m (54.8ft)

Find on map >>   Show street view

Structure Number: 1126,  Location: IN DETROIT (Lat: 42.420308,  Lng: -82.932122),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: HARPER AVE
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 58.230,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.0m (78.7ft)

Find on map >>   Show street view

Structure Number: 11261,  Location: IN DETROIT (Lat: 42.424764,  Lng: -82.928442),  Route carried "under" structure: Interstate 94,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: MOROSS RD NB
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 58.801,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 24.9m (81.7ft)

Find on map >>   Show street view

Structure Number: 11262,  Location: IN DETROIT (Lat: 42.424386,  Lng: -82.928739),  Route carried "under" structure: Interstate 94,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 130,650 (year 2011),  Truck Traffic: 6%,  Features Intersected: I-94,  Facility Carried by Structure: MOROSS RD SB
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 58.762,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 24.9m (81.7ft)

Find on map >>   Show street view

Structure Number: 1127,  Location: IN DETROIT (Lat: 42.393528,  Lng: -82.991889),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 148,534 (year 2007),  Truck Traffic: 5%,  Features Intersected: I-94,  Facility Carried by Structure: CR RR
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 52.368,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 11271,  Location: IN DETROIT (Lat: 42.393631,  Lng: -82.991703),  Route carried "under" structure: Interstate 94,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 148,534 (year 2007),  Truck Traffic: 5%,  Features Intersected: I-94,  Facility Carried by Structure: CR RR SPUR BR(ABN)
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 52.388,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.5m (64.0ft)

Find on map >>   Show street view

Structure Number: 11316,  Location: IN DETROIT (Lat: 42.331147,  Lng: -83.101242),  Route carried "under" structure: US 12,  Year Built: 1941,  Structure Length: 0. m,  Average Daily Traffic: 12,118 (year 2007),  Truck Traffic: 9%,  Features Intersected: US-12,  Facility Carried by Structure: SCOTTEN AVE
Minimum Vertical Clearance: 4.34m (14.24ft),  Kilometerpoint: 7.632,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 21.9m (71.9ft)

Find on map >>   Show street view

Structure Number: 11319,  Location: IN DETROIT (Lat: 42.331294,  Lng: -83.102817),  Route carried "under" structure: US 12,  Year Built: 1941,  Structure Length: 0. m,  Average Daily Traffic: 12,118 (year 2007),  Truck Traffic: 9%,  Features Intersected: US-12,  Facility Carried by Structure: CONRAIL
Minimum Vertical Clearance: 4.29m (14.07ft),  Kilometerpoint: 7.492,  Lanes under structure: 8,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 22.8m (74.8ft)

Find on map >>   Show street view

Structure Number: 1132,  Location: IN DETROIT @ SCOTTEN 4000 (Lat: 42.331164,  Lng: -83.099461),  Route carried "under" structure: US 12,  Year Built: 1941,  Structure Length: 0. m,  Average Daily Traffic: 12,118 (year 2007),  Truck Traffic: 9%,  Features Intersected: US-12,  Facility Carried by Structure: CONRAIL
Minimum Vertical Clearance: 4.29m (14.07ft),  Kilometerpoint: 7.778,  Lanes under structure: 8,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 23.1m (75.8ft)

Find on map >>   Show street view

Structure Number: 11377,  Location: IN DETROIT O S SERVICE RD (Lat: 42.407103,  Lng: -83.083917),  Route carried "under" structure: ServiceState highway 8,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 7,500 (year 0000),  Truck Traffic: 5%,  Features Intersected: S SERVICE DRIVE, M-8
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 0.137,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.6m (103.7ft)

Find on map >>   Show street view

Structure Number: 11378,  Location: IN DETROIT M-8 WB RAMP (Lat: 42.408236,  Lng: -83.083486),  Route carried "under" structure: Ramp State highway 8,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 18,900 (year 0000),  Features Intersected: I-75 RAMP TO WB M-8,  Facility Carried by Structure: N SERVICE RD
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 0.571,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.2m (122.0ft)

Find on map >>   Show street view

Structure Number: 11379,  Location: IN DETROIT (Lat: 42.413131,  Lng: -83.068839),  Route carried "under" structure: State highway 8,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 37,076 (year 2007),  Truck Traffic: 4%,  Features Intersected: M-8,  Facility Carried by Structure: JOSEPH CAMPAU
Minimum Vertical Clearance: 5.31m (17.42ft),  Kilometerpoint: 8.174,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.9m (85.0ft)

Find on map >>   Show street view

Structure Number: 1138,  Location: IN DETROIT (Lat: 42.410767,  Lng: -83.072833),  Route carried "under" structure: State highway 8,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 37,076 (year 2007),  Truck Traffic: 4%,  Features Intersected: M-8,  Facility Carried by Structure: GODDARD AVENUE
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 7.752,  Lanes on structure: 2,  Lanes under structure: 10,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.9m (130.9ft)

Find on map >>   Show street view

Structure Number: 11383,  Location: IN DETROIT (Lat: 42.330153,  Lng: -83.059461),  Route carried "under" structure: State highway 10,  Year Built: 1954,  Structure Length: 0. m,  Average Daily Traffic: 74,300 (year 2007),  Truck Traffic: 1%,  Features Intersected: M-10,  Facility Carried by Structure: PORTER ST WALKOVER
Minimum Vertical Clearance: 5.31m (17.42ft),  Kilometerpoint: 18.885,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 29.8m (97.8ft)

Find on map >>   Show street view

Structure Number: 11386,  Location: IN DETROIT (Lat: 42.345894,  Lng: -83.069183),  Route carried "under" structure: State highway 10,  Year Built: 1953,  Structure Length: 0. m,  Average Daily Traffic: 111,518 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: SELDEN AVE WALKOVE
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 16.926,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>   Show street view

Structure Number: 11387,  Location: IN DETROIT (Lat: 42.349461,  Lng: -83.070881),  Route carried "under" structure: State highway 10,  Year Built: 1953,  Structure Length: 0. m,  Average Daily Traffic: 111,518 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: CANFIELD AV WALKOV
Minimum Vertical Clearance: 4.78m (15.68ft),  Kilometerpoint: 16.504,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 22.5m (73.8ft)

Find on map >>   Show street view

Structure Number: 11388,  Location: IN DETROIT (Lat: 42.355550,  Lng: -83.074350),  Route carried "under" structure: State highway 10,  Year Built: 1953,  Structure Length: 0. m,  Average Daily Traffic: 129,400 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: MERRICK AVE WALKOV
Minimum Vertical Clearance: 5.77m (18.93ft),  Kilometerpoint: 15.772,  Lanes under structure: 8,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 23.4m (76.8ft)

Find on map >>   Show street view

Structure Number: 11389,  Location: IN DETROIT (Lat: 42.326475,  Lng: -83.052503),  Route carried "under" structure: State highway 10,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 74,078 (year 2007),  Truck Traffic: 1%,  Features Intersected: M-10 JOHN LODGE FRWY,  Facility Carried by Structure: JOE L WALKWAY
Minimum Vertical Clearance: 6.10m (20.01ft),  Kilometerpoint: 19.601,  Lanes under structure: 8,  Material/Design: Steel,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 30.4m (99.7ft)

Find on map >>   Show street view

Structure Number: 1139,  Location: IN DETROIT (Lat: 42.336706,  Lng: -83.038397),  Route carried "under" structure: Interstate 375,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 48,074 (year 2007),  Truck Traffic: 1%,  Features Intersected: I-375,  Facility Carried by Structure: MONROE AVE
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 1.112,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>   Show street view

Structure Number: 11391,  Location: IN DETROIT (Lat: 42.335675,  Lng: -83.037733),  Route carried "under" structure: Interstate 375,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 48,074 (year 2007),  Truck Traffic: 2%,  Features Intersected: I-375,  Facility Carried by Structure: LAFAYETTE AVE
Minimum Vertical Clearance: 4.44m (14.57ft),  Kilometerpoint: 1.001,  Lanes on structure: 6,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>   Show street view

Structure Number: 11392,  Location: IN DETROIT (Lat: 42.333347,  Lng: -83.036158),  Route carried "under" structure: Interstate 375,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 48,856 (year 2003),  Truck Traffic: 2%,  Features Intersected: I-375,  Facility Carried by Structure: LARNED ST
Minimum Vertical Clearance: 4.70m (15.42ft),  Kilometerpoint: 0.715,  Lanes on structure: 5,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.2m (53.1ft)

Find on map >>   Show street view

Structure Number: 11393,  Location: IN DETROIT (Lat: 42.332592,  Lng: -83.035886),  Route carried "under" structure: Interstate 375,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 18,762 (year 2007),  Truck Traffic: 5%,  Features Intersected: I-375,  Facility Carried by Structure: JEFFERSON AVE
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 0.608,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.6m (70.9ft)

Find on map >>   Show street view

Structure Number: 11394,  Location: IN DETROIT (Lat: 42.332258,  Lng: -83.035994),  Route carried "under" structure: Interstate 375,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 18,762 (year 2007),  Truck Traffic: 5%,  Features Intersected: I-375,  Facility Carried by Structure: CHRYSLER DR
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 0.570,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.0m (55.8ft)

Find on map >>   Show street view

Structure Number: 11395,  Location: IN DETROIT (Lat: 42.327158,  Lng: -83.047847),  Route carried "under" structure: State highway 10,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 74,078 (year 2007),  Truck Traffic: 1%,  Features Intersected: M-10,  Facility Carried by Structure: WASHINGTON ST
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 20.037,  Lanes on structure: 6,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.8m (51.8ft)

Find on map >>   Show street view

Structure Number: 11396,  Location: IN DETROIT (Lat: 42.326439,  Lng: -83.051972),  Route carried "under" structure: State highway 10,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 37,039 (year 2007),  Truck Traffic: 1%,  Features Intersected: M-10 NB,  Facility Carried by Structure: LARNED ST RAMP
Minimum Vertical Clearance: 4.37m (14.34ft),  Kilometerpoint: 19.659,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Length of Maximum Span: 31.1m (102.0ft)

Find on map >>   Show street view

Structure Number: 11397,  Location: IN DETROIT (Lat: 42.327200,  Lng: -83.055556),  Route carried "under" structure: State highway 10,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 74,300 (year 2007),  Truck Traffic: 1%,  Features Intersected: M-10,  Facility Carried by Structure: M-85 (FORT ST,)
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 19.345,  Lanes on structure: 6,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.7m (54.8ft)

Find on map >>   Show street view

Structure Number: 11398,  Location: IN DETROIT (Lat: 42.327886,  Lng: -83.056658),  Route carried "under" structure: State highway 10,  Year Built: 1952,  Structure Length: 0. m,  Average Daily Traffic: 74,300 (year 2007),  Truck Traffic: 1%,  Features Intersected: M-10,  Facility Carried by Structure: LAFAYETTE BLVD
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 19.224,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.8m (58.4ft)

Find on map >>   Show street view

Structure Number: 11399,  Location: IN DETROIT (Lat: 42.328564,  Lng: -83.057661),  Route carried "under" structure: State highway 10,  Year Built: 1953,  Structure Length: 0. m,  Average Daily Traffic: 74,300 (year 2007),  Truck Traffic: 1%,  Features Intersected: M-10,  Facility Carried by Structure: HOWARD ST
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 19.112,  Lanes on structure: 3,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.0m (59.1ft)

Find on map >>   Show street view

Structure Number: 114,  Location: IN DETROIT (Lat: 42.331586,  Lng: -83.061181),  Route carried "under" structure: State highway 10,  Year Built: 1954,  Structure Length: 0. m,  Average Daily Traffic: 52,258 (year 2007),  Truck Traffic: 1%,  Features Intersected: M-10 NB,  Facility Carried by Structure: US-12
Minimum Vertical Clearance: 4.65m (15.26ft),  Kilometerpoint: 18.672,  Lanes on structure: 9,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 19.4m (63.6ft)

Find on map >>   Show street view

Structure Number: 11401,  Location: IN DETROIT (Lat: 42.331550,  Lng: -83.061883),  Route carried "under" structure: State highway 10,  Year Built: 1954,  Structure Length: 0. m,  Average Daily Traffic: 52,258 (year 2007),  Truck Traffic: 1%,  Features Intersected: M-10 SB,  Facility Carried by Structure: US-12
Minimum Vertical Clearance: 4.78m (15.68ft),  Kilometerpoint: 18.637,  Lanes on structure: 9,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 20.0m (65.6ft)

Find on map >>   Show street view

Structure Number: 11402,  Location: IN DETROIT (Lat: 42.331850,  Lng: -83.061481),  Route carried "under" structure: State highway 10,  Year Built: 1954,  Structure Length: 0. m,  Average Daily Traffic: 104,516 (year 2007),  Truck Traffic: 1%,  Features Intersected: M-10,  Facility Carried by Structure: BAGLEY AV RAMPS
Minimum Vertical Clearance: 4.34m (14.24ft),  Kilometerpoint: 18.634,  Lanes on structure: 4,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.7m (77.8ft)

Find on map >>   Show street view

Structure Number: 11403,  Location: IN DETROIT (Lat: 42.339167,  Lng: -83.066114),  Route carried "under" structure: State highway 10,  Year Built: 1953,  Structure Length: 0. m,  Average Daily Traffic: 111,518 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: GRAND RIVER AVE
Minimum Vertical Clearance: 4.34m (14.24ft),  Kilometerpoint: 17.671,  Lanes on structure: 10,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.7m (81.0ft)

Find on map >>   Show street view

Structure Number: 11404,  Location: IN DETROIT (Lat: 42.343225,  Lng: -83.068011),  Route carried "under" structure: State highway 10,  Year Built: 2017,  Structure Length: 0. m,  Average Daily Traffic: 98,775 (year 2018),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: MLK JR BLVD EB
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 17.222,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 22.7m (74.5ft)

Find on map >>   Show street view

Structure Number: 11405,  Location: IN DETROIT (Lat: 42.351625,  Lng: -83.072083),  Route carried "under" structure: State highway 10,  Year Built: 1950,  Structure Length: 0. m,  Average Daily Traffic: 129,400 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: FOREST AVE
Minimum Vertical Clearance: 4.37m (14.34ft),  Kilometerpoint: 16.247,  Lanes on structure: 6,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.7m (54.8ft)

Find on map >>   Show street view

Structure Number: 11406,  Location: IN DETROIT (Lat: 42.353769,  Lng: -83.073392),  Route carried "under" structure: State highway 10,  Year Built: 1950,  Structure Length: 0. m,  Average Daily Traffic: 129,400 (year 2007),  Truck Traffic: 1%,  Features Intersected: M-10,  Facility Carried by Structure: WARREN AV
Minimum Vertical Clearance: 4.34m (14.24ft),  Kilometerpoint: 15.967,  Lanes on structure: 10,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.6m (61.0ft)

Find on map >>   Show street view

Structure Number: 11407,  Location: IN CITY OF DETROIT (Lat: 42.325717,  Lng: -83.053119),  Route carried "under" structure: City street 82,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 7,500 (year 1988),  Truck Traffic: 2%,  Features Intersected: JEFFERSON AVE,  Facility Carried by Structure: RAMP FROM M-10
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 3.304,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.2m (108.9ft)

Find on map >>   Show street view

Structure Number: 11408,  Location: IN CITY OF DETROIT (Lat: 42.326178,  Lng: -83.052139),  Route carried "under" structure: City street 2057,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 31,500 (year 1993),  Features Intersected: WB JEFFERSON AVE,  Facility Carried by Structure: M-10 SB
Minimum Vertical Clearance: 4.37m (14.34ft),  Kilometerpoint: 3.397,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Length of Maximum Span: 25.0m (82.0ft)

Find on map >>   Show street view

Structure Number: 11409,  Location: IN DETROIT (Lat: 42.326928,  Lng: -83.054936),  Route carried "under" structure: State highway 10,  Year Built: 1950,  Structure Length: 0. m,  Average Daily Traffic: 74,078 (year 2007),  Truck Traffic: 3%,  Features Intersected: M-10,  Facility Carried by Structure: W C C C RR (ABN)
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 19.437,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.2m (59.7ft)

Find on map >>   Show street view

Structure Number: 1141,  Location: IN DETROIT (Lat: 42.327017,  Lng: -83.055214),  Route carried "under" structure: State highway 10,  Year Built: 1950,  Structure Length: 0. m,  Average Daily Traffic: 74,078 (year 2007),  Truck Traffic: 3%,  Features Intersected: M-10,  Facility Carried by Structure: RR PARK'GDECK(ABN)
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 19.398,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.6m (61.0ft)

Find on map >>   Show street view

Structure Number: 11412,  Location: IN DETROIT (Lat: 42.363078,  Lng: -83.078708),  Route carried "under" structure: State highway 10,  Year Built: 1950,  Structure Length: 0. m,  Average Daily Traffic: 126,308 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: HOLDEN AVE WALKOVE
Minimum Vertical Clearance: 4.39m (14.40ft),  Kilometerpoint: 14.863,  Lanes under structure: 8,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 23.4m (76.8ft)

Find on map >>   Show street view

Structure Number: 11413,  Location: IN DETROIT (Lat: 42.375747,  Lng: -83.087511),  Route carried "under" structure: State highway 10,  Year Built: 1955,  Structure Length: 0. m,  Average Daily Traffic: 126,934 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: PINGREE AV WALKOVE
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 13.281,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 21.0m (68.9ft)

Find on map >>   Show street view

Structure Number: 11414,  Location: IN DETROIT (Lat: 42.377186,  Lng: -83.088492),  Route carried "under" structure: State highway 10,  Year Built: 1955,  Structure Length: 0. m,  Average Daily Traffic: 126,934 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: GLADSTONE AVE WALK
Minimum Vertical Clearance: 5.72m (18.77ft),  Kilometerpoint: 13.102,  Lanes under structure: 9,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 26.2m (86.0ft)

Find on map >>   Show street view

Structure Number: 11415,  Location: IN DETROIT (Lat: 42.390611,  Lng: -83.104081),  Route carried "under" structure: State highway 10,  Year Built: 1955,  Structure Length: 0. m,  Average Daily Traffic: 134,688 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: MONTEREY AV WALKOV
Minimum Vertical Clearance: 4.90m (16.08ft),  Kilometerpoint: 11.053,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Frame,  Length of Maximum Span: 41.3m (135.5ft)

Find on map >>   Show street view

Structure Number: 11416,  Location: IN DETROIT (Lat: 42.392653,  Lng: -83.105578),  Route carried "under" structure: State highway 10,  Year Built: 1955,  Structure Length: 0. m,  Average Daily Traffic: 134,688 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: HIGHLAND AV WALKOV
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 10.796,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Frame,  Length of Maximum Span: 43.0m (141.1ft)

Find on map >>   Show street view

Structure Number: 11417,  Location: IN DETROIT (Lat: 42.400253,  Lng: -83.113219),  Route carried "under" structure: State highway 10,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 156,084 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: FORD AVE WALKOVER
Minimum Vertical Clearance: 5.44m (17.85ft),  Kilometerpoint: 9.743,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 29.3m (96.1ft)

Find on map >>   Show street view

Structure Number: 11418,  Location: IN DETROIT (Lat: 42.404628,  Lng: -83.120939),  Route carried "under" structure: State highway 10,  Year Built: 1956,  Structure Length: 0. m,  Average Daily Traffic: 156,084 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: LOG CABIN AV WALKO
Minimum Vertical Clearance: 5.36m (17.59ft),  Kilometerpoint: 8.942,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 24.9m (81.7ft)

Find on map >>   Show street view

Structure Number: 11419,  Location: IN DETROIT (Lat: 42.405122,  Lng: -83.123289),  Route carried "under" structure: State highway 10,  Year Built: 1956,  Structure Length: 0. m,  Average Daily Traffic: 156,084 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: BAYLIS AVE WALKOVE
Minimum Vertical Clearance: 4.78m (15.68ft),  Kilometerpoint: 8.744,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 24.0m (78.7ft)

Find on map >>   Show street view

Structure Number: 1142,  Location: IN DETROIT (Lat: 42.404897,  Lng: -83.130486),  Route carried "under" structure: State highway 10,  Year Built: 1955,  Structure Length: 0. m,  Average Daily Traffic: 155,986 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: ALDEN AVE WALKOVER
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 8.153,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 28.1m (92.2ft)

Find on map >>   Show street view

Structure Number: 11421,  Location: IN DETROIT (Lat: 42.404947,  Lng: -83.133350),  Route carried "under" structure: State highway 10,  Year Built: 1955,  Structure Length: 0. m,  Average Daily Traffic: 155,986 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: MUIRLAND AV WALKOV
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 7.917,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 22.1m (72.5ft)

Find on map >>   Show street view

Structure Number: 11422,  Location: IN DETROIT (Lat: 42.404736,  Lng: -83.147089),  Route carried "under" structure: State highway 10,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 157,070 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: TULLER AVE WALKOVE
Minimum Vertical Clearance: 5.46m (17.91ft),  Kilometerpoint: 6.787,  Lanes under structure: 7,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 26.1m (85.6ft)

Find on map >>   Show street view

Structure Number: 11423,  Location: IN DETROIT (Lat: 42.404706,  Lng: -83.153372),  Route carried "under" structure: State highway 10,  Year Built: 1955,  Structure Length: 0. m,  Average Daily Traffic: 157,070 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: NORTHLAWN AV WALKO
Minimum Vertical Clearance: 5.59m (18.34ft),  Kilometerpoint: 6.269,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 26.8m (87.9ft)

Find on map >>   Show street view

Structure Number: 11424,  Location: IN DETROIT (Lat: 42.404564,  Lng: -83.156372),  Route carried "under" structure: State highway 10,  Year Built: 1955,  Structure Length: 0. m,  Average Daily Traffic: 157,070 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: WISCONSIN AVE WALK
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 6.022,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 27.6m (90.6ft)

Find on map >>   Show street view

Structure Number: 11425,  Location: IN DETROIT (Lat: 42.427369,  Lng: -83.182883),  Route carried "under" structure: State highway 10,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 124,630 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: MARGARETA AVE WALK
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 2.602,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.6m (54.5ft)

Find on map >>   Show street view

Structure Number: 11426,  Location: IN DETROIT (Lat: 42.365983,  Lng: -83.080892),  Route carried "under" structure: State highway 10,  Year Built: 1949,  Structure Length: 0. m,  Average Daily Traffic: 126,308 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: MILWAUKEE AVE
Minimum Vertical Clearance: 4.39m (14.40ft),  Kilometerpoint: 14.494,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.7m (54.8ft)

Find on map >>   Show street view

Structure Number: 11427,  Location: IN DETROIT (Lat: 42.367025,  Lng: -83.081672),  Route carried "under" structure: State highway 10,  Year Built: 1950,  Structure Length: 0. m,  Average Daily Traffic: 117,034 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: W GRAND BOULEVARD
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 14.340,  Lanes on structure: 9,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.6m (54.5ft)

Find on map >>   Show street view

Structure Number: 11428,  Location: IN DETROIT (Lat: 42.370264,  Lng: -83.083814),  Route carried "under" structure: State highway 10,  Year Built: 1954,  Structure Length: 0. m,  Average Daily Traffic: 117,034 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: PALLISTER AVENUE
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 13.957,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.1m (69.2ft)

Find on map >>   Show street view

Structure Number: 11429,  Location: IN DETROIT (Lat: 42.372031,  Lng: -83.084958),  Route carried "under" structure: State highway 10,  Year Built: 1954,  Structure Length: 0. m,  Average Daily Traffic: 126,934 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: SEWARD AVENUE
Minimum Vertical Clearance: 4.37m (14.34ft),  Kilometerpoint: 13.744,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.1m (75.8ft)

Find on map >>   Show street view

Structure Number: 1143,  Location: IN DETROIT (Lat: 42.374053,  Lng: -83.086358),  Route carried "under" structure: State highway 10,  Year Built: 1954,  Structure Length: 0. m,  Average Daily Traffic: 126,934 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: EUCLID AVENUE
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 13.493,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.2m (76.1ft)

Find on map >>   Show street view

Structure Number: 11431,  Location: IN DETROIT (Lat: 42.379717,  Lng: -83.090219),  Route carried "under" structure: State highway 10,  Year Built: 1954,  Structure Length: 0. m,  Average Daily Traffic: 126,934 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: CLAIRMOUNT AVENUE
Minimum Vertical Clearance: 4.88m (16.01ft),  Kilometerpoint: 12.785,  Lanes on structure: 3,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.3m (66.6ft)

Find on map >>   Show street view

Structure Number: 11432,  Location: 0.1 MI E OF CHICAGO BLVD (Lat: 42.381358,  Lng: -83.092267),  Route carried "under" structure: State highway 10,  Year Built: 1954,  Structure Length: 0. m,  Average Daily Traffic: 119,000 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: HAMILTON AVENUE
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 12.540,  Lanes on structure: 3,  Lanes under structure: 7,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.7m (107.3ft)

Find on map >>   Show street view

Structure Number: 11433,  Location: IN DETROIT (Lat: 42.382411,  Lng: -83.094647),  Route carried "under" structure: State highway 10,  Year Built: 1955,  Structure Length: 0. m,  Average Daily Traffic: 132,618 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: CHICAGO BLVD
Minimum Vertical Clearance: 4.44m (14.57ft),  Kilometerpoint: 12.267,  Lanes on structure: 6,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.6m (74.1ft)

Find on map >>   Show street view

Structure Number: 11434,  Location: IN DETROIT (Lat: 42.384483,  Lng: -83.099550),  Route carried "under" structure: State highway 10,  Year Built: 1955,  Structure Length: 0. m,  Average Daily Traffic: 132,618 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: CALVERT AVE
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 11.831,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.4m (57.1ft)

Find on map >>   Show street view

Structure Number: 11435,  Location: IN DETROIT (Lat: 42.387842,  Lng: -83.102111),  Route carried "under" structure: State highway 10,  Year Built: 1955,  Structure Length: 0. m,  Average Daily Traffic: 134,688 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: WEBB AVE
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 11.401,  Lanes on structure: 5,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.7m (54.8ft)

Find on map >>   Show street view

Structure Number: 11436,  Location: IN DETROIT (Lat: 42.394889,  Lng: -83.107208),  Route carried "under" structure: State highway 10,  Year Built: 1955,  Structure Length: 0. m,  Average Daily Traffic: 134,688 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10,  Facility Carried by Structure: GLENDALE AVE
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 10.513,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.1m (56.1ft)

Find on map >>   Show street view

Structure Number: 11437,  Location: IN DETROIT OVER M-10 SB (Lat: 42.398167,  Lng: -83.110103),  Route carried "under" structure: State highway 10,  Year Built: 1956,  Structure Length: 0. m,  Average Daily Traffic: 78,042 (year 2007),  Truck Traffic: 2%,  Features Intersected: M-10 SB,  Facility Carried by Structure: M-8 EB DAVISON
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 10.081,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.5m (73.8ft)

Discuss Detroit, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.