Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Toledo, Ohio (OH)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 309Number of bridges
  • 7,083ft / 2,159mTotal length
  • $659,445,000Total costs
  • 7,287,020Total average daily traffic
  • 979,698Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Toledo
  • No street view available for this location

New bridges in Toledo, OH - historical statistics
  • New bridges - historical statistics
  • 51910-1919
  • 21920-1929
  • 71930-1939
  • 31940-1949
  • 201950-1959
  • 571960-1969
  • 371970-1979
  • 141980-1989
  • 281990-1999
  • 562000-2009
  • 612010-2019
  • 192020-2022
Reconstructed bridges in Toledo, OH - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 01960-1969
  • 11970-1979
  • 31980-1989
  • 111990-1999
  • 192000-2009
  • 192010-2019
  • 52020-2022
Average Bridge Daily Traffic in Toledo, OH
Average Bridge Truck Traffic in Toledo, OH
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 32.0%Excellent
  • 32.6%Very good
  • 23.3%Good
  • 7.0%Satisfactory
  • 3.5%Fair
  • 1.2%Poor
  • 0.6%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 28.2%Excellent
  • 26.4%Very good
  • 31.6%Good
  • 10.9%Satisfactory
  • 1.7%Fair
  • 1.1%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 25.9%Excellent
  • 29.3%Very good
  • 33.3%Good
  • 10.9%Satisfactory
  • 0.6%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 24.7%Excellent
  • 34.4%Very good
  • 24.7%Good
  • 12.9%Satisfactory
  • 2.2%Fair
  • 1.1%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 16.7%Very good
  • 55.6%Good
  • 27.8%Satisfactory
Find on map >>   Show street view

Structure Number: 4803418,  Location: JCT. IR 475/IR 75 (Lat: 41.674550,  Lng: -83.573919),  Route carried "on" structure: Interstate 75,  Year Built: 2016,  Status: Open,  Structure Length: 9.72m (31.89ft),  Average Daily Traffic: 30,500 (year 2014),  Truck Traffic: 21%,  Average Future Daily Traffic: 31,770 (year 2034),  Design Load: HL 93,  Features Intersected: IR 475 WB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.419,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 37.1m (121.7ft),  Curb-To-Curb Width: 17.5m (57.4ft),  Out-to-Out Width: 18.4m (60.4ft)

Condition: Deck: Very good,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 55.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 9.72m (31.89ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4803469,  Location: I-75 S OVER OTTAWA RIVER (Lat: 41.676669,  Lng: -83.573889),  Route carried "on" structure: Interstate 75,  Year Built: 2016,  Status: Open,  Structure Length: 8.31m (27.26ft),  Average Daily Traffic: 30,500 (year 2014),  Truck Traffic: 21%,  Average Future Daily Traffic: 31,770 (year 2034),  Design Load: HL 93,  Features Intersected: OTTAWA RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.612,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 33.8m (110.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Very good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 8.31m (27.26ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4803515,  Location: I-75 N Ramp to Jeep Pkw (Lat: 41.678969,  Lng: -83.571911),  Route carried "on" structure: Ramp Interstate 75,  Year Built: 1972,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 7.80m (25.59ft),  Average Daily Traffic: 2,400 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,800 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: RAMP OVER OTTAWA RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.886,  Lanes on structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.1m (79.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Good,  Operating Rating: 87.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4803582,  Location: Over Ottawa River (Lat: 41.679169,  Lng: -83.572219),  Route carried "on" structure: Interstate 75,  Year Built: 2017,  Status: Open,  Structure Length: 8.14m (26.71ft),  Average Daily Traffic: 81,060 (year 2014),  Truck Traffic: 20%,  Average Future Daily Traffic: 83,380 (year 2034),  Design Load: HL 93,  Features Intersected: OTTAWA RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.886,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 26.8m (87.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.5m (86.9ft),  Curb-To-Curb Width: 27.3m (89.6ft),  Out-to-Out Width: 28.2m (92.5ft)

Condition: Deck: Good,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Very good,  Operating Rating: 74.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 8.14m (26.71ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4803671,  Location: I-75 over Willys Parkway (Lat: 41.681981,  Lng: -83.571469),  Route carried "on" structure: Ramp Interstate 75,  Year Built: 2018,  Status: Open,  Structure Length: 2.63m (8.63ft),  Average Daily Traffic: 29,250 (year 2014),  Truck Traffic: 14%,  Average Future Daily Traffic: 29,330 (year 2034),  Design Load: HL 93,  Features Intersected: RAMP NC-3
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.240,  Lanes on structure: 2,  Lanes under structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 24.8m (81.4ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.62m (8.60ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4803701,  Location: JCT. IR 75/WILLYS PKWY (Lat: 41.683331,  Lng: -83.570281),  Route carried "on" structure: Interstate 75,  Year Built: 2017,  Status: Open,  Structure Length: 3.37m (11.06ft),  Average Daily Traffic: 51,750 (year 2014),  Truck Traffic: 21%,  Average Future Daily Traffic: 53,900 (year 2034),  Design Load: HL 93,  Features Intersected: WILLYS PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.369,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 32.9m (107.9ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.38m (11.09ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4803744,  Location: JCT. IR 75/WILLYS PKWY (Lat: 41.682781,  Lng: -83.569719),  Route carried "on" structure: Interstate 75,  Year Built: 2017,  Status: Open,  Structure Length: 3.38m (11.09ft),  Average Daily Traffic: 51,750 (year 2014),  Truck Traffic: 21%,  Average Future Daily Traffic: 53,900 (year 2034),  Design Load: HL 93,  Features Intersected: WILLYS PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.369,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.0m (108.3ft),  Curb-To-Curb Width: 22.6m (74.1ft),  Out-to-Out Width: 23.6m (77.4ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.38m (11.09ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 480376,  Location: JCT I-75 and WILLYS PKWY (Lat: 41.683331,  Lng: -83.570831),  Route carried "on" structure: Ramp Interstate 75,  Year Built: 2018,  Status: Open,  Structure Length: 3.37m (11.06ft),  Average Daily Traffic: 29,230 (year 2010),  Truck Traffic: 14%,  Average Future Daily Traffic: 29,310 (year 2030),  Design Load: HL 93,  Features Intersected: WILLYS PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.369,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 32.9m (107.9ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.35m (10.99ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4803787,  Location: 0.2 MI E INT USR24 & IR75 (Lat: 41.686931,  Lng: -83.552139),  Route carried "on" structure: Interstate 75,  Year Built: 1970,  Year Reconstructed: 2017,  Status: Open,  Structure Length: 5.82m (19.09ft),  Average Daily Traffic: 83,634 (year 2015),  Truck Traffic: 16%,  Average Future Daily Traffic: 116,084 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: PHILLIPS AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.155,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.4m (70.2ft),  Skew: 31 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 26.4m (86.6ft),  Out-to-Out Width: 45.0m (147.6ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4803795,  Location: 1.05 Mi. N. of I-475 (Lat: 41.688461,  Lng: -83.562381),  Route carried "on" structure: Interstate 75,  Year Built: 2018,  Status: Open,  Structure Length: 61.27m (201.02ft),  Average Daily Traffic: 61,427 (year 2014),  Truck Traffic: 21%,  Average Future Daily Traffic: 64,993 (year 2034),  Design Load: HL 93,  Features Intersected: BERDAN,OTTAWA R. US24 CR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.286,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 22.4m (73.5ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 14,  Length of Maximum Span: 48.9m (160.4ft),  Curb-To-Curb Width: 22.4m (73.5ft),  Out-to-Out Width: 23.5m (77.1ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4803809,  Location: 1.05 MI. N of I-475 (Lat: 41.688369,  Lng: -83.562219),  Route carried "on" structure: Interstate 75,  Year Built: 2016,  Status: Open,  Structure Length: 61.27m (201.02ft),  Average Daily Traffic: 61,427 (year 2014),  Truck Traffic: 21%,  Average Future Daily Traffic: 64,993 (year 2034),  Design Load: HL 93,  Features Intersected: BERDAN,OTTAWA R.,US24 CR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.286,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 22.4m (73.5ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 14,  Length of Maximum Span: 48.9m (160.4ft),  Curb-To-Curb Width: 22.4m (73.5ft),  Out-to-Out Width: 23.5m (77.1ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4803876,  Location: I-75 over Lagrange St. (Lat: 41.688669,  Lng: -83.544931),  Route carried "on" structure: Interstate 75,  Year Built: 1970,  Year Reconstructed: 2017,  Status: Open,  Structure Length: 5.01m (16.44ft),  Average Daily Traffic: 83,634 (year 2015),  Truck Traffic: 17%,  Average Future Daily Traffic: 116,084 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: LAGRANGE ST.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.783,  Lanes on structure: 6,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 44.8m (147.0ft),  Out-to-Out Width: 46.8m (153.5ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Excellent,  Operating Rating: 74.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 4803973,  Location: 0.5 Mi. E. of LaGrange St (Lat: 41.689269,  Lng: -83.534469),  Route carried "on" structure: City street M0569,  Year Built: 2017,  Status: Open,  Structure Length: 4.33m (14.21ft),  Average Daily Traffic: 1,450 (year 2017),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,490 (year 2037),  Design Load: HL 93,  Features Intersected: POLISH VILLAGE OVERPASS,  Facility Carried by Structure: IR 75
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.871,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Excellent,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.33m (14.21ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4804058,  Location: IR 75 over Stickney Ave. (Lat: 41.689850,  Lng: -83.527239),  Route carried "on" structure: Interstate 75,  Year Built: 1967,  Year Reconstructed: 2017,  Status: Open,  Structure Length: 5.15m (16.90ft),  Average Daily Traffic: 75,973 (year 2015),  Truck Traffic: 19%,  Average Future Daily Traffic: 105,451 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: STICKNEY AVE.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.263,  Lanes on structure: 8,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.0m (82.0ft),  Curb-To-Curb Width: 40.8m (133.9ft),  Out-to-Out Width: 44.2m (145.0ft)

Condition: Deck: Excellent,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 81.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 4804279,  Location: JCT. IR 75 & IR 280 (Lat: 41.690131,  Lng: -83.518519),  Route carried "on" structure: Interstate 75,  Year Built: 2016,  Status: Open,  Structure Length: 4.79m (15.72ft),  Average Daily Traffic: 75,600 (year 2017),  Truck Traffic: 21%,  Average Future Daily Traffic: 78,299 (year 2037),  Design Load: HL 93,  Features Intersected: RAMP NB IR280 TO SB IR75
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.987,  Lanes on structure: 4,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 29.3m (96.1ft),  Skew: 35 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 45.7m (149.9ft),  Curb-To-Curb Width: 29.0m (95.1ft),  Out-to-Out Width: 31.0m (101.7ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Very good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.79m (15.72ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4804333,  Location: JCT. IR 75 & IR 280 (Lat: 41.690231,  Lng: -83.516731),  Route carried "on" structure: Interstate 75,  Year Built: 2016,  Status: Open,  Structure Length: 3.83m (12.57ft),  Average Daily Traffic: 80,670 (year 2018),  Truck Traffic: 22%,  Average Future Daily Traffic: 82,000 (year 2038),  Design Load: HL 93,  Features Intersected: IR 280 SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.148,  Lanes on structure: 4,  Lanes under structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 34 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 36.6m (120.1ft),  Curb-To-Curb Width: 14.5m (47.6ft),  Out-to-Out Width: 32.2m (105.6ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 87.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 68.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4804414,  Location: 1/4 MI N OF JCT IR 280 (Lat: 41.691411,  Lng: -83.510669),  Route carried "on" structure: Interstate 75,  Year Built: 1957,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 7.56m (24.80ft),  Average Daily Traffic: 76,020 (year 2010),  Truck Traffic: 25%,  Average Future Daily Traffic: 105,516 (year 2030),  Design Load: HS 20,  Features Intersected: CHRYSLER DR & ANNARBOR R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.663,  Lanes on structure: 7,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 39.0m (128.0ft),  Skew: 31 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 28.7m (94.2ft),  Curb-To-Curb Width: 39.0m (128.0ft),  Out-to-Out Width: 41.0m (134.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 35.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4804473,  Location: 1/2 MI W. OF JCT IR 280 (Lat: 41.691789,  Lng: -83.508481),  Route carried "on" structure: Interstate 75,  Year Built: 1957,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 9.48m (31.10ft),  Average Daily Traffic: 76,020 (year 2010),  Truck Traffic: 25%,  Average Future Daily Traffic: 105,516 (year 2030),  Design Load: HS 20+Mod,  Features Intersected: HOFFMAN RD. CSX RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.856,  Lanes on structure: 7,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 38.2m (125.3ft),  Skew: 31 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 38.2m (125.3ft),  Out-to-Out Width: 39.8m (130.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4804562,  Location: .8 MI N. OF JCT IR 280 (Lat: 41.693511,  Lng: -83.503339),  Route carried "on" structure: Interstate 75,  Year Built: 1957,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 9.72m (31.89ft),  Average Daily Traffic: 76,020 (year 2010),  Truck Traffic: 25%,  Average Future Daily Traffic: 105,516 (year 2030),  Design Load: HS 20+Mod,  Features Intersected: CSX/CANADIAN NATIONAL RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.339,  Lanes on structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 38.2m (125.3ft),  Skew: 35 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 39.0m (128.0ft),  Curb-To-Curb Width: 38.2m (125.3ft),  Out-to-Out Width: 40.3m (132.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4804678,  Location: 150 YDS W JCT SUDER AVE (Lat: 41.706461,  Lng: -83.501939),  Route carried "on" structure: Ramp County highway C0516,  Year Built: 1997,  Status: Open,  Structure Length: 8.60m (28.22ft),  Average Daily Traffic: 8,799 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 84,493 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: IR 75,  Facility Carried by Structure: OTTAWA RIVER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.805,  Lanes on structure: 1,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 43.3m (142.1ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4804686,  Location: 300 FEET SOUTH BENORE RD (Lat: 41.711050,  Lng: -83.502069),  Route carried "on" structure: Interstate 75,  Year Built: 1959,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 4.97m (16.31ft),  Average Daily Traffic: 64,045 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 84,493 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: OTTAWA RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 16.303,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 10.7m (35.1ft),  Curb-To-Curb Width: 35.4m (116.1ft),  Out-to-Out Width: 36.3m (119.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: January 2021,  Underwater Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4804724,  Location: 100 YDS. WEST OF SUDER (Lat: 41.712661,  Lng: -83.501611),  Route carried "on" structure: City street M0537,  Year Built: 1997,  Status: Open,  Structure Length: 7.38m (24.21ft),  Average Daily Traffic: 13,396 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 14,000 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: IR 75,  Facility Carried by Structure: BENORE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.069,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 24 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.0m (118.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4804759,  Location: 1/4 MI N ALEXIS RD INTER (Lat: 41.725639,  Lng: -83.495331),  Route carried "on" structure: City street C0172,  Year Built: 1998,  Status: Open,  Structure Length: 7.74m (25.39ft),  Average Daily Traffic: 4,623 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 75,285 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: IR 75,  Facility Carried by Structure: SUDER AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.153,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 37.8m (124.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 20.2m (66.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4805038,  Location: JCT IR 75 (Lat: 41.678000,  Lng: -83.573750),  Route carried "on" structure: State highway 120,  Year Built: 2009,  Status: Open,  Structure Length: 19.48m (63.91ft),  Average Daily Traffic: 9,051 (year 2015),  Truck Traffic: 10%,  Average Future Daily Traffic: 12,563 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: I-75 OTTAWA RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 25.395,  Lanes on structure: 5,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 49.1m (161.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 23.3m (76.4ft)

Condition: Deck: Excellent,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4805119,  Location: 1.5 MILE WEST OF IR 75 (Lat: 41.722450,  Lng: -83.531300),  Route carried "on" structure: State highway 184,  Year Built: 1975,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 7.07m (23.20ft),  Average Daily Traffic: 24,599 (year 2019),  Truck Traffic: 3%,  Average Future Daily Traffic: 32,729 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: ANN ARBOR R.R.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.390,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.4m (66.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 22.0m (72.2ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4805127,  Location: JCT. SR 184/STICKNEY AVE (Lat: 41.722539,  Lng: -83.529269),  Route carried "on" structure: State highway 184,  Year Built: 1975,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 13.08m (42.91ft),  Average Daily Traffic: 24,599 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 32,729 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: NORFOLK SOUTERN/STICKNEY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.518,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 9 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 22.0m (72.2ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 38.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4805143,  Location: 1.41 Mi. East of USR 24 (Lat: 41.722781,  Lng: -83.519539),  Route carried "on" structure: State highway 184,  Year Built: 1975,  Status: Open,  Structure Length: 2.93m (9.61ft),  Average Daily Traffic: 23,657 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 32,729 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: SHANTEE & SILVER CREEKS,  Facility Carried by Structure: ALEXIS ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.355,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.0m (82.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 22.3m (73.2ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 4805151,  Location: 0.1 MILE WEST OF IR 75 (Lat: 41.722331,  Lng: -83.503850),  Route carried "on" structure: State highway 184,  Year Built: 1975,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 8.66m (28.41ft),  Average Daily Traffic: 23,657 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 40,746 (year 2039),  Design Load: HS 20,  Features Intersected: CANADIAN NATIONAL RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.659,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.7m (81.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 27.2m (89.2ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 38.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4805178,  Location: 0.5 MI S SUDER AVE & IR75 (Lat: 41.721431,  Lng: -83.501300),  Route carried "on" structure: State highway 184,  Year Built: 1975,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 6.22m (20.41ft),  Average Daily Traffic: 23,657 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 22,863 (year 2039),  Design Load: HS 20,  Features Intersected: IR 75
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.884,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.9m (62.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 19.7m (64.6ft),  Out-to-Out Width: 21.9m (71.9ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4805259,  Location: Monroe SR 51 over IR 475 (Lat: 41.685281,  Lng: -83.614039),  Route carried "on" structure: State highway 51,  Year Built: 1970,  Year Reconstructed: 2018,  Status: Open,  Structure Length: 7.01m (23.00ft),  Average Daily Traffic: 28,295 (year 2019),  Truck Traffic: 1%,  Average Future Daily Traffic: 34,500 (year 2039),  Design Load: HS 20,  Features Intersected: IR 475,  Facility Carried by Structure: MONROE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.615,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.3m (83.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 20.8m (68.2ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 4805313,  Location: 0.01 Mile N. of S. Cove (Lat: 41.671311,  Lng: -83.584411),  Route carried "on" structure: State highway 51,  Year Built: 1961,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 14,971 (year 2019),  Truck Traffic: 1%,  Average Future Daily Traffic: 26,082 (year 2039),  Design Load: HS 20,  Features Intersected: OTTAWA RIVER,  Facility Carried by Structure: MONROE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.702,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 20.8m (68.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 4805372,  Location: Monroe St SR-51 over I-75 (Lat: 41.661419,  Lng: -83.563661),  Route carried "on" structure: State highway 51,  Year Built: 1967,  Year Reconstructed: 2017,  Status: Open,  Structure Length: 5.67m (18.60ft),  Average Daily Traffic: 14,884 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 20,659 (year 2035),  Design Load: HS 20,  Features Intersected: IR 75
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.658,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 24.5m (80.4ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 4805402,  Location: 0.3 MI. SW OF SR 120 (Lat: 41.651361,  Lng: -83.533450),  Route carried "on" structure: State highway 65,  Year Built: 1982,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 17,252 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 20,118 (year 2039),  Design Load: HL 93,  Features Intersected: PED WALK CONCOURSE B,  Facility Carried by Structure: PEDESTRIAN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.518,  Lanes on structure: 7,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 22.9m (75.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 3.4m (11.2ft),  Right: 2.8m (9.2ft)

Condition: Culverts: Good,  Operating Rating: 74.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 58.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 480541,  Location: 0.2 MI. SW OF SR 120 (Lat: 41.652239,  Lng: -83.532561),  Route carried "on" structure: State highway 65,  Year Built: 1982,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 17,252 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 20,118 (year 2039),  Design Load: HL 93,  Features Intersected: PED WALK CONCOURSE A,  Facility Carried by Structure: PEDESTRIAN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.630,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 20.4m (66.9ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 1.8m (5.9ft)

Condition: Culverts: Good,  Operating Rating: 84.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 64.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 4805497,  Location: DORR ST. OVER IR 75 (Lat: 41.652969,  Lng: -83.552100),  Route carried "on" structure: State highway 246,  Year Built: 2019,  Status: Open,  Structure Length: 9.61m (31.53ft),  Average Daily Traffic: 9,500 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 10,450 (year 2038),  Design Load: HL 93,  Features Intersected: IR 75
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.399,  Lanes on structure: 3,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 51.1m (167.7ft),  Curb or Sidewalk Widths: Left: 4.0m (13.1ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Very good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4805739,  Location: 1.1 MI SE OF SR 65 (Lat: 41.643561,  Lng: -83.497750),  Route carried "on" structure: Interstate 280,  Year Built: 1957,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 2.62m (8.60ft),  Average Daily Traffic: 49,583 (year 2019),  Truck Traffic: 11%,  Average Future Daily Traffic: 77,378 (year 2039),  Design Load: HS 15,  Features Intersected: STARR AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.541,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 31 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.0m (82.0ft),  Curb-To-Curb Width: 37.5m (123.0ft),  Out-to-Out Width: 38.4m (126.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4805763,  Location: 0.60 MI SE OF SR 65 (Lat: 41.650111,  Lng: -83.501850),  Route carried "on" structure: Interstate 280,  Year Built: 1957,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 52,360 (year 2019),  Truck Traffic: 11%,  Average Future Daily Traffic: 58,000 (year 2039),  Design Load: H 20,  Features Intersected: Seaman Rd.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.361,  Lanes on structure: 8,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 40.4m (132.5ft),  Skew: 31 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.4m (57.1ft),  Curb-To-Curb Width: 41.5m (136.2ft),  Out-to-Out Width: 44.5m (146.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Discuss Toledo, Ohio (OH) on our hugely popular Ohio forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.