Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Fresno, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 551Number of bridges
  • 7,218ft / 2,200mTotal length
  • $14,141,000Total costs
  • 16,572,698Total average daily traffic
  • 1,423,123Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Fresno
  • No street view available for this location

New bridges in Fresno, CA - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 41910-1919
  • 121920-1929
  • 131930-1939
  • 181940-1949
  • 551950-1959
  • 831960-1969
  • 331970-1979
  • 701980-1989
  • 1491990-1999
  • 912000-2009
  • 202010-2019
  • 22020-2022
Reconstructed bridges in Fresno, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11930-1939
  • 41940-1949
  • 51950-1959
  • 121960-1969
  • 71970-1979
  • 81980-1989
  • 121990-1999
  • 112000-2009
  • 52010-2019
Average Bridge Daily Traffic in Fresno, CA
Average Bridge Truck Traffic in Fresno, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 75.2%Good
  • 2.9%Satisfactory
  • 19.9%Fair
  • 1.6%Poor
  • 0.3%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 77.8%Good
  • 4.2%Satisfactory
  • 16.4%Fair
  • 1.3%Poor
  • 0.3%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 75.6%Good
  • 1.9%Satisfactory
  • 22.2%Fair
  • 0.3%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 11.7%Excellent
  • 55.5%Very good
  • 31.4%Good
  • 1.5%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 36.6%Good
  • 58.5%Satisfactory
  • 4.9%Poor
Find on map >>   Show street view

Structure Number: 42 0312R,  Location: 06-FRE-180-R56.41-FRE (Lat: 36.741528,  Lng: -119.813081),  Route carried "on" structure: State highway 180,  Year Built: 2003,  Status: Open,  Structure Length: 4.89m (16.04ft),  Average Daily Traffic: 8,000 (year 1999),  Truck Traffic: 4%,  Average Future Daily Traffic: 9,251 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: N99-W180 CONNECTOR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 56.410,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 48.9m (160.4ft),  Curb-To-Curb Width: 16.8m (55.1ft),  Out-to-Out Width: 17.9m (58.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0313L,  Location: 06-FRE-180-R56.66-FRE (Lat: 36.743881,  Lng: -119.809364),  Route carried "on" structure: State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 5.97m (19.59ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 56,282 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: G STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 56.660,  Lanes on structure: 4,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.4m (106.3ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 21.7m (71.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0313R,  Location: 06-FRE-180-R56.67-FRE (Lat: 36.743700,  Lng: -119.808856),  Route carried "on" structure: State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 5.99m (19.65ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 56,282 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: G STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 56.670,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.7m (104.0ft),  Curb-To-Curb Width: 26.3m (86.3ft),  Out-to-Out Width: 27.3m (89.6ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0314L,  Location: 06-FRE-180-R56.78-FRE (Lat: 36.744742,  Lng: -119.807681),  Route carried "on" structure: State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 12.51m (41.04ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 56,282 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: UP RR, SJVR, & H STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 56.780,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 1,  Length of Maximum Span: 43.9m (144.0ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 21.7m (71.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0314R,  Location: 06-FRE-180-R56.78-FRE (Lat: 36.744508,  Lng: -119.807403),  Route carried "on" structure: State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 12.43m (40.78ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 56,282 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: UP RR, SJVR, & H STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 56.780,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 1,  Length of Maximum Span: 43.1m (141.4ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0315L,  Location: 06-FRE-180-R57.07-FRE (Lat: 36.747136,  Lng: -119.803203),  Route carried "on" structure: State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 4.41m (14.47ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 56,282 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BROADWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.070,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 43.3m (142.1ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 21.9m (71.9ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0315R,  Location: 06-FRE-180-R57.07-FRE (Lat: 36.746756,  Lng: -119.803203),  Route carried "on" structure: State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 4.41m (14.47ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 56,282 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: BROADWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.070,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 43.9m (144.0ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 21.2m (69.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0316K,  Location: 06-FRE-180-R57.24-FRE (Lat: 36.748856,  Lng: -119.800614),  Route carried "on" structure: Ramp State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 4.69m (15.39ft),  Average Daily Traffic: 101 (year 2013),  Truck Traffic: 15%,  Average Future Daily Traffic: 116 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: FULTON STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.240,  Lanes on structure: 1,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 45.3m (148.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0316L,  Location: 06-FRE-180-R57.24-FRE (Lat: 36.748525,  Lng: -119.800611),  Route carried "on" structure: State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 4.95m (16.24ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 56,296 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: FULTON STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.240,  Lanes on structure: 3,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 48.1m (157.8ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0316R,  Location: 06-FRE-180-R57.24-FRE (Lat: 36.748214,  Lng: -119.800597),  Route carried "on" structure: State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 4.87m (15.98ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 56,296 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: FULTON STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.240,  Lanes on structure: 3,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 47.3m (155.2ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0317L,  Location: 06-FRE-180-R57.34-FRE (Lat: 36.749325,  Lng: -119.799125),  Route carried "on" structure: State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 4.60m (15.09ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 56,296 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: VAN NESS AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.340,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 44.6m (146.3ft),  Curb-To-Curb Width: 21.5m (70.5ft),  Out-to-Out Width: 22.5m (73.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0317R,  Location: 06-FRE-180-R57.34-FRE (Lat: 36.749008,  Lng: -119.799117),  Route carried "on" structure: State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 4.53m (14.86ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 56,296 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: VAN NESS AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.340,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 45.3m (148.6ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0318L,  Location: 06-FRE-180-R57.45-FRE (Lat: 36.750125,  Lng: -119.797514),  Route carried "on" structure: State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 26.18m (85.89ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 56,296 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: BELMONT AV, SAN PABLO AV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.450,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 40.8m (133.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 21.7m (71.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0318R,  Location: 06-FRE-180-R57.45-FRE (Lat: 36.749850,  Lng: -119.797125),  Route carried "on" structure: State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 24.70m (81.04ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 56,296 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: BELMONT, PARK, SAN PABLO
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.450,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 42.2m (138.5ft),  Curb-To-Curb Width: 21.8m (71.5ft),  Out-to-Out Width: 22.8m (74.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0319K,  Location: 06-FRE-180-R57.84-FRE (Lat: 36.752222,  Lng: -119.790744),  Route carried "on" structure: Ramp State highway 180,  Year Built: 1980,  Status: Open,  Structure Length: 3.59m (11.78ft),  Average Daily Traffic: 12,000 (year 2013),  Truck Traffic: 2%,  Average Future Daily Traffic: 25,079 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: BLACKSTONE AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.840,  Lanes on structure: 1,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 35.8m (117.5ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 42 0319L,  Location: 06-FRE-180-R57.84-FRE (Lat: 36.751981,  Lng: -119.790756),  Route carried "on" structure: State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 3.93m (12.89ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 56,296 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: BLACKSTONE AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.840,  Lanes on structure: 3,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 37.8m (124.0ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0319R,  Location: 06-FRE-180-R57.84-FRE (Lat: 36.751675,  Lng: -119.790747),  Route carried "on" structure: State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 3.93m (12.89ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 56,296 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: BLACKSTONE AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.840,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 37.8m (124.0ft),  Curb-To-Curb Width: 20.6m (67.6ft),  Out-to-Out Width: 21.6m (70.9ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0320L,  Location: 06-FRE-180-R57.92-FRE (Lat: 36.752231,  Lng: -119.789581),  Route carried "on" structure: State highway 180,  Year Built: 1980,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 56,296 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: ABBY STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.920,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 40.5m (132.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 21.8m (71.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0320R,  Location: 06-FRE-180-R57.92-FRE (Lat: 36.751975,  Lng: -119.789503),  Route carried "on" structure: State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 4.16m (13.65ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 56,296 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: ABBY STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.920,  Lanes on structure: 3,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 41.6m (136.5ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0320S,  Location: 06-FRE-180-R57.92-FRE (Lat: 36.751858,  Lng: -119.789483),  Route carried "on" structure: Ramp State highway 180,  Year Built: 1995,  Status: Open,  Structure Length: 3.90m (12.80ft),  Average Daily Traffic: 195 (year 2013),  Truck Traffic: 15%,  Average Future Daily Traffic: 326 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: ABBY STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.920,  Lanes on structure: 1,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 39.0m (128.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0321L,  Location: 06-FRE-180-R58.04-FRE (Lat: 36.752703,  Lng: -119.787367),  Route carried "on" structure: State highway 180,  Year Built: 1980,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 3.72m (12.20ft),  Average Daily Traffic: 49,500 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 138,071 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: BNSF RY & AMTRAK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 58.040,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 20.5m (67.3ft),  Out-to-Out Width: 21.5m (70.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0321R,  Location: 06-FRE-180-R58.04-FRE (Lat: 36.752322,  Lng: -119.787381),  Route carried "on" structure: State highway 180,  Year Built: 1980,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 3.72m (12.20ft),  Average Daily Traffic: 49,500 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 138,071 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: BNSF RY & AMTRAK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 58.040,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 23.4m (76.8ft),  Out-to-Out Width: 25.9m (85.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0322L,  Location: 06-FRE-180-R58.36-FRE (Lat: 36.753675,  Lng: -119.781708),  Route carried "on" structure: State highway 180,  Year Built: 1980,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 4.27m (14.01ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 138,071 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: FRESNO STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 58.360,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.5m (67.3ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 42.4m (139.1ft),  Curb-To-Curb Width: 20.5m (67.3ft),  Out-to-Out Width: 21.6m (70.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0322R,  Location: 06-FRE-180-R58.36-FRE (Lat: 36.753342,  Lng: -119.781706),  Route carried "on" structure: State highway 180,  Year Built: 1980,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 4.27m (14.01ft),  Average Daily Traffic: 49,500 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 138,071 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: FRESNO STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 58.360,  Lanes on structure: 5,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 25.4m (83.3ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 42.4m (139.1ft),  Curb-To-Curb Width: 24.3m (79.7ft),  Out-to-Out Width: 26.0m (85.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0323J,  Location: 06-FRE-180-R58.87-FRE (Lat: 36.755306,  Lng: -119.772878),  Route carried "on" structure: Ramp State highway 180,  Year Built: 1999,  Status: Open,  Structure Length: 5.36m (17.59ft),  Average Daily Traffic: 20,000 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 32,821 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: FIRST STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 58.870,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0323K,  Location: 06-FRE-180-R58.87-FRE (Lat: 36.755033,  Lng: -119.772772),  Route carried "on" structure: Ramp State highway 180,  Year Built: 1999,  Status: Open,  Structure Length: 5.36m (17.59ft),  Average Daily Traffic: 11,250 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 17,943 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: FIRST STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 58.870,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0323L,  Location: 06-FRE-180-R58.86-FRE (Lat: 36.754775,  Lng: -119.772758),  Route carried "on" structure: State highway 180,  Year Built: 1999,  Status: Open,  Structure Length: 5.06m (16.60ft),  Average Daily Traffic: 79,000 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 76,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: FIRST STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 58.860,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 25.3m (83.0ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0323R,  Location: 06-FRE-180-R58.86-FRE (Lat: 36.754394,  Lng: -119.772758),  Route carried "on" structure: State highway 180,  Year Built: 1999,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 5.06m (16.60ft),  Average Daily Traffic: 79,000 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 76,500 (year 2040),  Design Load: HL 93,  Features Intersected: FIRST STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 58.860,  Lanes on structure: 5,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 18,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 25.3m (83.0ft),  Curb-To-Curb Width: 24.4m (80.1ft),  Out-to-Out Width: 25.3m (83.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0326,  Location: 06-FRE-180-R59.88-FRE (Lat: 36.754272,  Lng: -119.754233),  Route carried "on" structure: City street ,  Year Built: 1999,  Status: Open,  Structure Length: 16.02m (52.56ft),  Average Daily Traffic: 23,400 (year 2010),  Truck Traffic: 3%,  Average Future Daily Traffic: 41,318 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 180,  Facility Carried by Structure: CEDAR AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 9,  Lanes under structure: 11,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 32.3m (106.0ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 43.8m (143.7ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 32.3m (106.0ft),  Out-to-Out Width: 44.5m (146.0ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0327G,  Location: 06-FRE-180-R59.90-FRE (Lat: 36.754467,  Lng: -119.752242),  Route carried "on" structure: Ramp State highway 180,  Year Built: 1999,  Status: Open,  Structure Length: 28.70m (94.16ft),  Average Daily Traffic: 21,000 (year 2009),  Truck Traffic: 3%,  Average Future Daily Traffic: 35,706 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 180 & RAMPS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 59.900,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 57.5m (188.6ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0328G,  Location: 06-FRE-180-R60.10-FRE (Lat: 36.757544,  Lng: -119.749050),  Route carried "on" structure: Ramp State highway 180,  Year Built: 1999,  Status: Open,  Structure Length: 4.18m (13.71ft),  Average Daily Traffic: 21,000 (year 2009),  Truck Traffic: 4%,  Average Future Daily Traffic: 35,706 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: OLIVE AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.100,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 41.8m (137.1ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0331F,  Location: 06-FRE-168S-R0.39-FRE (Lat: 36.755944,  Lng: -119.751353),  Route carried "on" structure: Ramp State highway 168,  Year Built: 1999,  Status: Open,  Structure Length: 7.01m (23.00ft),  Average Daily Traffic: 62,300 (year 2013),  Truck Traffic: 4%,  Average Future Daily Traffic: 100,829 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CEDAR AVE ON & OFF-RAMPS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.390,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 37.5m (123.0ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0332F,  Location: 06-FRE-168-R0.50L-FRE (Lat: 36.754739,  Lng: -119.745153),  Route carried "on" structure: Ramp State highway 168,  Year Built: 2005,  Status: Open,  Structure Length: 58.40m (191.60ft),  Average Daily Traffic: 12,000 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 35,825 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SR 180,RAMPS,OLIVE,MAPLE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.500,  Lanes on structure: 2,  Lanes under structure: 19,  Owner: State Highway Agency,  Approaching Roadway Width: 11.7m (38.4ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 11,  Length of Maximum Span: 75.5m (247.7ft),  Curb-To-Curb Width: 11.7m (38.4ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0333F,  Location: 06-FRE-168S-R0.52-FRE (Lat: 36.757506,  Lng: -119.749736),  Route carried "on" structure: Ramp State highway 168,  Year Built: 1999,  Status: Open,  Structure Length: 5.24m (17.19ft),  Average Daily Traffic: 62,300 (year 2010),  Truck Traffic: 4%,  Average Future Daily Traffic: 100,829 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: OLIVE AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.520,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 52.4m (171.9ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 42 0334L,  Location: 06-FRE-168S-R0.73-FRE (Lat: 36.761142,  Lng: -119.749364),  Route carried "on" structure: State highway 168,  Year Built: 1998,  Status: Open,  Structure Length: 5.55m (18.21ft),  Average Daily Traffic: 42,000 (year 2013),  Truck Traffic: 4%,  Average Future Daily Traffic: 72,432 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: FLORADORA AVE & SJVR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.730,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 16,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 31.1m (102.0ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 21.8m (71.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 42 0334R,  Location: 06-FRE-168S-R0.73-FRE (Lat: 36.761142,  Lng: -119.748992),  Route carried "on" structure: State highway 168,  Year Built: 1998,  Status: Open,  Structure Length: 5.55m (18.21ft),  Average Daily Traffic: 42,000 (year 2009),  Truck Traffic: 4%,  Average Future Daily Traffic: 72,673 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: FLORADORA AVE & SJVR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.730,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 16,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.6m (67.6ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 31.1m (102.0ft),  Curb-To-Curb Width: 20.6m (67.6ft),  Out-to-Out Width: 21.8m (71.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 42 0335L,  Location: 06-FRE-168S-R0.97-FRE (Lat: 36.764756,  Lng: -119.749386),  Route carried "on" structure: ServiceState highway 168,  Year Built: 1998,  Status: Open,  Structure Length: 6.10m (20.01ft),  Average Daily Traffic: 31,150 (year 2010),  Truck Traffic: 4%,  Average Future Daily Traffic: 50,414 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: MCKINLEY AVE, MILL DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.970,  Lanes on structure: 5,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.4m (119.4ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 21.0m (68.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 42 0335R,  Location: 06-FRE-168S-R0.97 (Lat: 36.764769,  Lng: -119.748967),  Route carried "on" structure: State highway 168,  Year Built: 1995,  Status: Open,  Structure Length: 6.10m (20.01ft),  Average Daily Traffic: 4,200 (year 2009),  Truck Traffic: 4%,  Average Future Daily Traffic: 5,781 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: MCKINLEY AVE, MILL DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.970,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 16,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.4m (119.4ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 21.1m (69.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 42 0337,  Location: 06-FRE-168S-R1.49-FRE (Lat: 36.772208,  Lng: -119.749711),  Route carried "on" structure: City street ,  Year Built: 1999,  Status: Open,  Structure Length: 7.38m (24.21ft),  Average Daily Traffic: 22,896 (year 2013),  Truck Traffic: 1%,  Average Future Daily Traffic: 29,433 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 168 & RAMPS,  Facility Carried by Structure: CLINTON AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 25.5m (83.7ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.9m (121.1ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 25.5m (83.7ft),  Out-to-Out Width: 26.3m (86.3ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Discuss Fresno, California (CA) on our hugely popular California forum.