Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Vernon, Texas (TX)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 66Number of bridges
  • 1,122ft / 342mTotal length
  • $3,677,000Total costs
  • 421,234Total average daily traffic
  • 102,361Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Vernon
  • No street view available for this location

New bridges in Vernon, TX - historical statistics
  • New bridges - historical statistics
  • 31920-1929
  • 81930-1939
  • 21940-1949
  • 51950-1959
  • 191960-1969
  • 31970-1979
  • 121980-1989
  • 51990-1999
  • 52000-2009
  • 42010-2019
Reconstructed bridges in Vernon, TX - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 31940-1949
  • 01950-1959
  • 11960-1969
  • 51970-1979
  • 31980-1989
  • 01990-1999
  • 12000-2009
Average Bridge Daily Traffic in Vernon, TX
Average Bridge Truck Traffic in Vernon, TX
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 55.9%Good
  • 26.5%Satisfactory
  • 14.7%Fair
  • 2.9%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 17.6%Very good
  • 41.2%Good
  • 32.4%Satisfactory
  • 5.9%Fair
  • 2.9%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 5.9%Very good
  • 29.4%Good
  • 50.0%Satisfactory
  • 14.7%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 5.1%Very good
  • 33.3%Good
  • 46.2%Satisfactory
  • 15.4%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 40.0%Satisfactory
  • 10.0%Fair
Find on map >>   Show street view

Structure Number: 32440004305013,  Location: 4.5 MI NW OF FM 432 (Lat: 34.239728,  Lng: -99.449267),  Route carried "on" structure: US 287,  Year Built: 1929,  Year Reconstructed: 1960,  Status: Open,  Structure Length: 4.88m (16.01ft),  Average Daily Traffic: 12,235 (year 2020),  Truck Traffic: 46%,  Average Future Daily Traffic: 24,470 (year 2040),  Features Intersected: BNSF RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.710,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 13.3m (43.6ft),  Out-to-Out Width: 13.9m (45.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 32440004305017,  Location: 1.1 MI N OF US 70 (Lat: 34.178514,  Lng: -99.323036),  Route carried "on" structure: US 287,  Year Built: 1928,  Year Reconstructed: 1982,  Status: Open,  Structure Length: 43.21m (141.77ft),  Average Daily Traffic: 10,953 (year 2020),  Truck Traffic: 49%,  Average Future Daily Traffic: 15,334 (year 2040),  Features Intersected: PEASE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.264,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 35,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 39.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 32440004305018,  Location: 1.0 MI N OF US 70 (Lat: 34.175086,  Lng: -99.321092),  Route carried "on" structure: US 287,  Year Built: 1928,  Year Reconstructed: 1982,  Status: Open,  Structure Length: 3.70m (12.14ft),  Average Daily Traffic: 10,953 (year 2020),  Truck Traffic: 49%,  Average Future Daily Traffic: 15,334 (year 2040),  Features Intersected: PEASE RIVER RELIEF
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.850,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.3m (40.4ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 32440004305019,  Location: 0.6 MI N OF US 70 (Lat: 34.170511,  Lng: -99.318272),  Route carried "on" structure: US 287,  Year Built: 1934,  Year Reconstructed: 1982,  Status: Open,  Structure Length: 6.58m (21.59ft),  Average Daily Traffic: 10,753 (year 2020),  Truck Traffic: 49%,  Average Future Daily Traffic: 15,334 (year 2040),  Design Load: H 15,  Features Intersected: BNSF RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 33.394,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 14.1m (46.3ft),  Curb-To-Curb Width: 11.7m (38.4ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.58m (21.59ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $164,000,  Roadway Improvement Cost: $41,000,  Total Project Cost: $205,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 32440004305101,  Location: 1.1 MI N OF US 70 (Lat: 34.178619,  Lng: -99.322808),  Route carried "on" structure: US 287,  Year Built: 1963,  Year Reconstructed: 1985,  Status: Open,  Structure Length: 42.67m (139.99ft),  Average Daily Traffic: 10,953 (year 2020),  Truck Traffic: 49%,  Average Future Daily Traffic: 15,334 (year 2040),  Design Load: HS 20,  Features Intersected: PEASE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.264,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 35,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 32440004305102,  Location: 1.0 MI N OF US 70 (Lat: 34.175200,  Lng: -99.320869),  Route carried "on" structure: US 287,  Year Built: 1963,  Status: Open,  Structure Length: 4.88m (16.01ft),  Average Daily Traffic: 10,953 (year 2020),  Truck Traffic: 49%,  Average Future Daily Traffic: 15,334 (year 2040),  Design Load: HS 20,  Features Intersected: PEASE RIVER RELIEF
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.843,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Fair,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 32440004305103,  Location: 0.6 MI N OF US 70 (Lat: 34.170450,  Lng: -99.317931),  Route carried "on" structure: US 287,  Year Built: 1963,  Status: Open,  Structure Length: 7.25m (23.79ft),  Average Daily Traffic: 10,953 (year 2020),  Truck Traffic: 49%,  Average Future Daily Traffic: 15,334 (year 2040),  Design Load: HS 20,  Features Intersected: BNSF RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 33.423,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 4,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 32440004305106,  Location: 0.1 MI NW OF US 70 (Lat: 34.163136,  Lng: -99.313856),  Route carried "on" structure: US 287,  Year Built: 1965,  Year Reconstructed: 2012,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 10,953 (year 2020),  Truck Traffic: 37%,  Average Future Daily Traffic: 15,334 (year 2040),  Features Intersected: NO NAME
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 34.261,  Lanes on structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 43.3m (142.1ft),  Skew: 29 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 1.8m (5.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: 3244000430513,  Location: 0.3 MI N OF US 70 (Lat: 34.167347,  Lng: -99.316239),  Route carried "on" structure: US 287,  Year Built: 1969,  Status: Open,  Structure Length: 8.53m (27.99ft),  Average Daily Traffic: 10,953 (year 2020),  Truck Traffic: 49%,  Average Future Daily Traffic: 15,334 (year 2040),  Design Load: HS 20,  Features Intersected: CONDON SPRINGS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 33.791,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Channel: Fair,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 32440004305166,  Location: 0.12 MI W OF FM 925 (Lat: 34.184347,  Lng: -99.332536),  Route carried "on" structure: ServiceUS 287,  Year Built: 1976,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 10,953 (year 2020),  Truck Traffic: 49%,  Average Future Daily Traffic: 15,334 (year 2040),  Design Load: HS 20,  Features Intersected: DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 31.258,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 6.3m (20.7ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 6.3m (20.7ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 32440004305167,  Location: JCT US 287 & FM 925 (Lat: 34.185158,  Lng: -99.330458),  Route carried "on" structure: Alternate State highway 925,  Year Built: 1976,  Status: Open,  Structure Length: 9.14m (29.99ft),  Average Daily Traffic: 169 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 232 (year 2040),  Design Load: H 15,  Features Intersected: US 287
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.959,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 6.9m (22.6ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 37.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 10.24m (33.60ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $1,449,000,  Roadway Improvement Cost: $816,000,  Total Project Cost: $2,501,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 32440004305173,  Location: US 70/287 AT BENTLEY ST (Lat: 34.160808,  Lng: -99.298608),  Route carried "on" structure: US 70,  Year Built: 1987,  Status: Open,  Structure Length: 5.36m (17.59ft),  Average Daily Traffic: 16,409 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 32,818 (year 2040),  Design Load: HS 20,  Features Intersected: BENTLEY STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 35.787,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.7m (38.4ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 32440004305174,  Location: US 70 AT BENTLEY ST (Lat: 34.160642,  Lng: -99.298581),  Route carried "on" structure: US 70,  Year Built: 1987,  Status: Open,  Structure Length: 5.36m (17.59ft),  Average Daily Traffic: 16,409 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 32,818 (year 2040),  Design Load: HS 20,  Features Intersected: BENTLEY ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 35.787,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 32440004305175,  Location: AT JCT US 70/287 & US 183 (Lat: 34.159828,  Lng: -99.284986),  Route carried "on" structure: US 70,  Year Built: 1987,  Status: Open,  Structure Length: 7.92m (25.98ft),  Average Daily Traffic: 16,718 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 33,436 (year 2040),  Design Load: HS 20,  Features Intersected: US 183/283
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 37.042,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 32440004305176,  Location: AT JCT US 70/287 & US 183 (Lat: 34.159647,  Lng: -99.284983),  Route carried "on" structure: US 70,  Year Built: 1987,  Status: Open,  Structure Length: 7.92m (25.98ft),  Average Daily Traffic: 16,718 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 33,436 (year 2040),  Design Load: HS 20,  Features Intersected: US 183/283
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 37.042,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 32440004305177,  Location: US 70/287 AT LAURIE ST. (Lat: 34.158597,  Lng: -99.271156),  Route carried "on" structure: US 70,  Year Built: 1987,  Status: Open,  Structure Length: 5.18m (16.99ft),  Average Daily Traffic: 14,427 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 30,854 (year 2040),  Design Load: HS 20,  Features Intersected: LAURIE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 38.310,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.7m (38.4ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 32440004305178,  Location: US 70 AT LAURIE ST. (Lat: 34.158378,  Lng: -99.271222),  Route carried "on" structure: US 70,  Year Built: 1987,  Status: Open,  Structure Length: 5.18m (16.99ft),  Average Daily Traffic: 15,423 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 30,354 (year 2040),  Design Load: HS 20,  Features Intersected: LAURIE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 38.310,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 32440004305205,  Location: 0.3 MI N OF US 70 (Lat: 34.167414,  Lng: -99.316047),  Route carried "on" structure: US 287,  Year Built: 2009,  Status: Open,  Structure Length: 8.84m (29.00ft),  Average Daily Traffic: 6,730 (year 2013),  Truck Traffic: 37%,  Average Future Daily Traffic: 9,420 (year 2033),  Design Load: HL 93,  Features Intersected: CONDON SPRINGS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 33.790,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Membrane: Other,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 32440004306097,  Location: JCT OF US 287&FM 1763 (Lat: 34.148250,  Lng: -99.227139),  Route carried "on" structure: State highway 1763,  Year Built: 1961,  Status: Open,  Structure Length: 5.79m (19.00ft),  Average Daily Traffic: 255 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 357 (year 2040),  Design Load: H 20,  Features Intersected: US 287
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.449,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 39.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 324400043061,  Location: 0.7 MI E OF FM 1763 (Lat: 34.145133,  Lng: -99.215603),  Route carried "on" structure: ServiceUS 70,  Year Built: 1961,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 57 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 80 (year 2040),  Features Intersected: PLUM CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.320,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.49m (4.89ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $2,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $3,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 32440004306107,  Location: 0.4 MI E OF US 283 (Lat: 34.158103,  Lng: -99.267094),  Route carried "on" structure: US 70,  Year Built: 1965,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 663 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 928 (year 2040),  Design Load: HS 20,  Features Intersected: DRAW,  Facility Carried by Structure: US 287 CROSSOVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.613,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: 32440004306108,  Location: 1.6 MI E OF US 283 (Lat: 34.156475,  Lng: -99.264003),  Route carried "on" structure: US 70,  Year Built: 1965,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 15,427 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 30,854 (year 2040),  Features Intersected: DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.962,  Lanes on structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 45.7m (149.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 2.1m (6.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: No rating analysis performed,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: 3244000430611,  Location: 1.9 MI E OF US 283 (Lat: 34.154678,  Lng: -99.253808),  Route carried "on" structure: State highway 1949,  Year Built: 1965,  Status: Open,  Structure Length: 6.43m (21.10ft),  Average Daily Traffic: 110 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 154 (year 2040),  Design Load: H 15,  Features Intersected: US 70/183/287
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.011,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 32440004306113,  Location: 0.5 MI W OF FM 1763 (Lat: 34.149689,  Lng: -99.235972),  Route carried "on" structure: US 70,  Year Built: 1965,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 8.02m (26.31ft),  Average Daily Traffic: 15,334 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 30,763 (year 2040),  Design Load: HS 20,  Features Intersected: VERNON ACCESS O-PASS,  Facility Carried by Structure: US 287 SB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 25.622,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 5 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 32440004306182,  Location: 0.7 MI E OF FM 1763 (Lat: 34.145589,  Lng: -99.215694),  Route carried "on" structure: US 70,  Year Built: 1991,  Status: Open,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 12,979 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 25,953 (year 2040),  Design Load: HS 20,  Features Intersected: PLUM CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.299,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 32440004306183,  Location: 0.7 MI E OF FM 1763 (Lat: 34.145356,  Lng: -99.215628),  Route carried "on" structure: US 70,  Year Built: 1991,  Status: Open,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 12,979 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 25,958 (year 2040),  Design Load: HS 20,  Features Intersected: PLUM CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.312,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 32440004306185,  Location: 1.1 MI W OF FM 1763 (Lat: 34.152497,  Lng: -99.245792),  Route carried "on" structure: US 70,  Year Built: 1995,  Status: Open,  Structure Length: 5.49m (18.01ft),  Average Daily Traffic: 15,384 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 30,768 (year 2040),  Design Load: HS 20,  Features Intersected: PARADISE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.678,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 32440004306186,  Location: 1.1 MI W OF FM 1763 (Lat: 34.152664,  Lng: -99.245556),  Route carried "on" structure: US 70,  Year Built: 1995,  Status: Open,  Structure Length: 5.49m (18.01ft),  Average Daily Traffic: 15,384 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 30,768 (year 2040),  Design Load: HS 20,  Features Intersected: PARADISE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.687,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Membrane: Other,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 32440004320042,  Location: 1.6 MI E OF US 183 (Lat: 34.150872,  Lng: -99.256392),  Route carried "on" structure: State highway 287,  Year Built: 1936,  Status: Open,  Structure Length: 2.99m (9.81ft),  Average Daily Traffic: 1,456 (year 2020),  Truck Traffic: 27%,  Average Future Daily Traffic: 2,038 (year 2040),  Features Intersected: PARADISE CREEK,  Facility Carried by Structure: LP 488 EB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 26.437,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.99m (9.81ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $7,000,  Roadway Improvement Cost: $2,000,  Total Project Cost: $9,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 32440004320058,  Location: 1.6 MI E OF US 183 (Lat: 34.151033,  Lng: -99.256378),  Route carried "on" structure: State highway 287,  Year Built: 1956,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 1,456 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 2,038 (year 2040),  Features Intersected: PARADISE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 26.437,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 11.2m (36.7ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.85m (15.91ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $245,000,  Roadway Improvement Cost: $61,000,  Total Project Cost: $306,000,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 32440004320105,  Location: 0.2 MI SW OF US 287 (Lat: 34.162039,  Lng: -99.314097),  Route carried "on" structure: State highway 287,  Year Built: 1965,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 1,220 (year 2013),  Truck Traffic: 19%,  Average Future Daily Traffic: 1,710 (year 2033),  Design Load: HS 20,  Features Intersected: OUTFALL CHANNEL,  Facility Carried by Structure: LP 417
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.665,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 9 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 1.5m (4.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.5 metric tons,  Method Used To Determine Inventory Rating: No rating analysis performed,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: 32440012403009,  Location: 2.2 MI S OF US 70 (Lat: 34.120919,  Lng: -99.279497),  Route carried "on" structure: US 183,  Year Built: 1931,  Year Reconstructed: 1975,  Status: Open,  Structure Length: 2.16m (7.09ft),  Average Daily Traffic: 1,269 (year 2020),  Truck Traffic: 17%,  Average Future Daily Traffic: 1,777 (year 2040),  Features Intersected: PARADISE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.029,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 3244001240301,  Location: 3.8 MI S OF US 287 (Lat: 34.106064,  Lng: -99.274394),  Route carried "on" structure: US 183,  Year Built: 1931,  Year Reconstructed: 1975,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 1,097 (year 2020),  Truck Traffic: 18%,  Average Future Daily Traffic: 1,536 (year 2040),  Design Load: H 15,  Features Intersected: DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.748,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 22.7 metric tons,  Method Used To Determine Operating Rating: No rating analysis performed,  Inventory Rating: 17.0 metric tons,  Method Used To Determine Inventory Rating: No rating analysis performed,  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: 32440012403178,  Location: 0.73 MI N OF US 287 (Lat: 34.172117,  Lng: -99.282878),  Route carried "on" structure: US 283,  Year Built: 2012,  Status: Open,  Structure Length: 16.76m (54.99ft),  Average Daily Traffic: 2,001 (year 2020),  Truck Traffic: 21%,  Average Future Daily Traffic: 3,220 (year 2030),  Design Load: HL 93,  Features Intersected: PEASE RIVER RELIEF
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.232,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.6m (44.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 13.3m (43.6ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Membrane: Other,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 32440012403179,  Location: 1.08 MI N OF US 287 (Lat: 34.179708,  Lng: -99.277978),  Route carried "on" structure: US 283,  Year Built: 2012,  Status: Open,  Structure Length: 57.00m (187.01ft),  Average Daily Traffic: 2,001 (year 2020),  Truck Traffic: 21%,  Average Future Daily Traffic: 2,801 (year 2040),  Design Load: HL 93,  Features Intersected: PEASE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.267,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.6m (44.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 17,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 13.3m (43.6ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Membrane: Other,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 32440014607131,  Location: JCT US 70 AND US 287 (Lat: 34.162983,  Lng: -99.312714),  Route carried "on" structure: US 287,  Year Built: 1969,  Status: Open,  Structure Length: 7.01m (23.00ft),  Average Daily Traffic: 21,372 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 42,744 (year 2040),  Design Load: HS 20,  Features Intersected: US 70
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 34.390,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Allowable Stress Design (ASD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Allowable Stress Design (ASD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 32440014607132,  Location: 1.6 MI W OF US 183 (Lat: 34.162850,  Lng: -99.312903),  Route carried "on" structure: US 287,  Year Built: 1969,  Status: Open,  Structure Length: 7.01m (23.00ft),  Average Daily Traffic: 21,372 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 42,744 (year 2040),  Design Load: HS 20,  Features Intersected: US 70
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 34.392,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.4m (37.4ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Allowable Stress Design (ASD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Allowable Stress Design (ASD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 32440082101001,  Location: 1.1 MI W OF US 283 (Lat: 34.082269,  Lng: -99.286197),  Route carried "on" structure: State highway 433,  Year Built: 1943,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 395 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 553 (year 2040),  Design Load: H 15,  Features Intersected: DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.042,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 1.8m (5.9ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: 32440082101002,  Location: 0.9 MI W OF US 283 (Lat: 34.082997,  Lng: -99.282961),  Route carried "on" structure: State highway 433,  Year Built: 1943,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 395 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 553 (year 2040),  Design Load: H 15,  Features Intersected: DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.356,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 1.8m (5.9ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021
Find on map >>   Show street view

Structure Number: 32440082101007,  Location: 2.0 MI W OF US 283 (Lat: 34.079075,  Lng: -99.301669),  Route carried "on" structure: State highway 433,  Year Built: 1956,  Status: Open,  Structure Length: 2.41m (7.91ft),  Average Daily Traffic: 395 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 553 (year 2040),  Features Intersected: PARADISE CRK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.688,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 6.9m (22.6ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 32440082102009,  Location: 0.6 MI E OF US 283 (Lat: 34.102403,  Lng: -99.262419),  Route carried "on" structure: State highway 433,  Year Built: 1959,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 379 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 531 (year 2040),  Features Intersected: DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.007,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: No rating analysis performed,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: No rating analysis performed,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 32440083202001,  Location: 1.3 MI W OF US 287 (Lat: 34.185608,  Lng: -99.367497),  Route carried "on" structure: State highway 925,  Year Built: 1930,  Year Reconstructed: 1951,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 339 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 339 (year 2020),  Features Intersected: BOGGY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.338,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.5m (21.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.22m (4.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $83,000,  Roadway Improvement Cost: $53,000,  Total Project Cost: $136,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 32440083202002,  Location: 1.6 MI W OF US 287 (Lat: 34.184589,  Lng: -99.372322),  Route carried "on" structure: State highway 925,  Year Built: 1930,  Year Reconstructed: 1951,  Status: Open,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 339 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 475 (year 2040),  Features Intersected: DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.875,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 4.6m (15.1ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 6.5m (21.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.83m (6.00ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $111,000,  Roadway Improvement Cost: $71,000,  Total Project Cost: $182,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous