  • National Bridge Inventory (NBI) Statistics
  • 155Number of bridges
  • 1,831ft / 558mTotal length
  • 7,745,903Total average daily traffic
  • 493,264Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Rancho Cucamonga
  • No street view available for this location

New bridges in Rancho Cucamonga, CA - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 11930-1939
  • 31960-1969
  • 531970-1979
  • 221980-1989
  • 151990-1999
  • 522000-2009
  • 82010-2019
Reconstructed bridges in Rancho Cucamonga, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11930-1939
  • 01940-1949
  • 01950-1959
  • 01960-1969
  • 11970-1979
  • 11980-1989
  • 51990-1999
  • 62000-2009
  • 12010-2019
Average Bridge Daily Traffic in Rancho Cucamonga, CA
Average Bridge Truck Traffic in Rancho Cucamonga, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 66.3%Good
  • 32.5%Fair
  • 1.3%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 68.8%Good
  • 31.3%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 98.8%Good
  • 1.3%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 69.0%Excellent
  • 24.1%Very good
  • 6.9%Good
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 45.8%Good
  • 54.2%Satisfactory
Find on map >>   Show street view

Structure Number: 54 067,  Location: 08-SBD-040-R154.42 (Lat: 34.716883,  Lng: -114.491414),  Route carried "on" structure: Interstate 40,  Year Built: 1966,  Status: Open,  Structure Length: 4.45m (14.60ft),  Average Daily Traffic: 17,300 (year 2019),  Truck Traffic: 46%,  Average Future Daily Traffic: 18,900 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: MARINA ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 154.420,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 22.9m (75.1ft),  Skew: 32 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.7m (58.1ft),  Curb-To-Curb Width: 23.4m (76.8ft),  Out-to-Out Width: 24.6m (80.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: May 2021,  Other Special Inspection Date: August 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 54 0673,  Location: 08-SBD-210-6.40-RCUC (Lat: 34.135897,  Lng: -117.584953),  Route carried "on" structure: City street ,  Year Built: 2000,  Status: Open,  Structure Length: 6.05m (19.85ft),  Average Daily Traffic: 6,500 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,500 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 210,  Facility Carried by Structure: HERMOSA AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 9,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.2m (99.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 24.0m (78.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0674,  Location: 08-SBD-210-6.91-RCUC (Lat: 34.136392,  Lng: -117.576108),  Route carried "on" structure: City street ,  Year Built: 2001,  Status: Open,  Structure Length: 7.50m (24.61ft),  Average Daily Traffic: 28,000 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 40,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 210,  Facility Carried by Structure: HAVEN AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 33.6m (110.2ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 40.0m (131.2ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 33.6m (110.2ft),  Out-to-Out Width: 37.8m (124.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0676,  Location: 08-SBD-210-7.91-RCUC (Lat: 34.136878,  Lng: -117.558750),  Route carried "on" structure: City street ,  Year Built: 2001,  Status: Open,  Structure Length: 7.33m (24.05ft),  Average Daily Traffic: 14,000 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 18,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 210,  Facility Carried by Structure: MILLIKEN AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 31.6m (103.7ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 39.0m (128.0ft),  Curb or Sidewalk Widths: Left: 3.4m (11.2ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 31.6m (103.7ft),  Out-to-Out Width: 37.8m (124.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0677,  Location: 08-SBD-210-8.91-RCUC (Lat: 34.136303,  Lng: -117.541142),  Route carried "on" structure: State highway 210,  Year Built: 2001,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 193,000 (year 2017),  Truck Traffic: 5%,  Average Future Daily Traffic: 220,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: DAY CREEK CHANNEL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.910,  Lanes on structure: 10,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 50.8m (166.7ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 54 0679,  Location: 08-SBD-210-9.92-RCUC (Lat: 34.136761,  Lng: -117.523592),  Route carried "on" structure: City street ,  Year Built: 1999,  Status: Open,  Structure Length: 7.62m (25.00ft),  Average Daily Traffic: 9,000 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 12,242 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 210,  Facility Carried by Structure: ETIWANDA AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 40.4m (132.5ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 22.2m (72.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0681G,  Location: 08-SBD-210-11.02-RCUC (Lat: 34.135614,  Lng: -117.504186),  Route carried "on" structure: Ramp State highway 210,  Year Built: 1999,  Status: Open,  Structure Length: 4.66m (15.29ft),  Average Daily Traffic: 3,001 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 5,101 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: EAST ETIWANDA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.020,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 46.6m (152.9ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0681L,  Location: 08-SBD-210-11.02-RCUC (Lat: 34.136383,  Lng: -117.504189),  Route carried "on" structure: State highway 210,  Year Built: 2000,  Status: Open,  Structure Length: 4.20m (13.78ft),  Average Daily Traffic: 93,000 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 102,017 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: EAST ETIWANDA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.020,  Lanes on structure: 5,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 26.8m (87.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 42.0m (137.8ft),  Curb-To-Curb Width: 26.8m (87.9ft),  Out-to-Out Width: 27.8m (91.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0681R,  Location: 08-SBD-210-11.02-RCUC (Lat: 34.136092,  Lng: -117.504192),  Route carried "on" structure: State highway 210,  Year Built: 2000,  Status: Open,  Structure Length: 4.20m (13.78ft),  Average Daily Traffic: 93,000 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 102,017 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: EAST ETIWANDA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.020,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 22.0m (72.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 42.0m (137.8ft),  Curb-To-Curb Width: 22.0m (72.2ft),  Out-to-Out Width: 23.0m (75.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0910F,  Location: 08-SBD-015-2.41-ONT (Lat: 34.066922,  Lng: -117.541017),  Route carried "on" structure: Ramp Interstate 15,  Year Built: 1975,  Status: Open,  Structure Length: 69.19m (227.00ft),  Average Daily Traffic: 18,000 (year 2019),  Truck Traffic: 10%,  Average Future Daily Traffic: 23,000 (year 2040),  Design Load: HS 20,  Features Intersected: I10,I15,CONNS,CHAN,OMPWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.410,  Lanes on structure: 2,  Lanes under structure: 28,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Number Of Approach Spans: 11,  Length of Maximum Span: 68.6m (225.1ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 87.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0912,  Location: 08-SBD-015-3.05-RCUC (Lat: 34.077006,  Lng: -117.544425),  Route carried "on" structure: Interstate 15,  Year Built: 1974,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 4.90m (16.08ft),  Average Daily Traffic: 196,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 220,015 (year 2042),  Design Load: HS 20,  Features Intersected: FOURTH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.050,  Lanes on structure: 13,  Lanes under structure: 8,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 66.2m (217.2ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 49.0m (160.8ft),  Curb-To-Curb Width: 66.2m (217.2ft),  Out-to-Out Width: 67.6m (221.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 66.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0918,  Location: 08-SBD-015-3.81-RCUC (Lat: 34.088036,  Lng: -117.544442),  Route carried "on" structure: Interstate 15,  Year Built: 1975,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 3.81m (12.50ft),  Average Daily Traffic: 196,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 209,539 (year 2042),  Design Load: Greater than HL93,  Features Intersected: SIXTH STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.810,  Lanes on structure: 8,  Lanes under structure: 3,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 48.5m (159.1ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 38.1m (125.0ft),  Curb-To-Curb Width: 48.5m (159.1ft),  Out-to-Out Width: 49.9m (163.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0919L,  Location: 08-SBD-015-4.10-RCUC (Lat: 34.092183,  Lng: -117.543969),  Route carried "on" structure: Interstate 15,  Year Built: 1975,  Status: Open,  Structure Length: 4.85m (15.91ft),  Average Daily Traffic: 98,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 136,200 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: METROLINK & BNSF RY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.100,  Lanes on structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.4m (66.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 54.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0919R,  Location: 08-SBD-015-4.10-RCUC (Lat: 34.092189,  Lng: -117.543639),  Route carried "on" structure: Interstate 15,  Year Built: 1975,  Status: Open,  Structure Length: 4.85m (15.91ft),  Average Daily Traffic: 98,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 136,200 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: METROLINK & BNSF RY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.100,  Lanes on structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 54.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0920R,  Location: 08-SBD-015-4.47-RCUC (Lat: 34.096744,  Lng: -117.541544),  Route carried "on" structure: Interstate 15,  Year Built: 1975,  Status: Open,  Structure Length: 9.57m (31.40ft),  Average Daily Traffic: 98,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 136,200 (year 2042),  Design Load: HS 20,  Features Intersected: DAY CANYON CHANNEL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.470,  Lanes on structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 21.0m (68.9ft),  Skew: 6 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 33.8m (110.9ft),  Curb-To-Curb Width: 19.8m (65.0ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Excellent,  Operating Rating: 69.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 53.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 9.57m (31.40ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 54 0921L,  Location: 08-SBD-015-4.61-RCUC (Lat: 34.098925,  Lng: -117.540375),  Route carried "on" structure: Interstate 15,  Year Built: 1975,  Status: Open,  Structure Length: 4.72m (15.49ft),  Average Daily Traffic: 98,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 136,200 (year 2042),  Design Load: HS 20,  Features Intersected: ARROW ROUTE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.610,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.4m (66.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 47.2m (154.9ft),  Curb-To-Curb Width: 19.8m (65.0ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 69.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0921R,  Location: 08-SBD-015-4.61-RCUC (Lat: 34.098919,  Lng: -117.539992),  Route carried "on" structure: Interstate 15,  Year Built: 1975,  Status: Open,  Structure Length: 4.72m (15.49ft),  Average Daily Traffic: 98,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 136,200 (year 2042),  Design Load: HS 20,  Features Intersected: ARROW ROUTE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.610,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.4m (66.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 47.2m (154.9ft),  Curb-To-Curb Width: 19.8m (65.0ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 69.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0922L,  Location: 08-SBD-015-5.28-RCUC (Lat: 34.106106,  Lng: -117.532483),  Route carried "on" structure: Interstate 15,  Year Built: 1975,  Status: Open,  Structure Length: 7.20m (23.62ft),  Average Daily Traffic: 101,500 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 120,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: FOOTHILL BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.280,  Lanes on structure: 5,  Lanes under structure: 8,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 26.0m (85.3ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 39.0m (128.0ft),  Curb-To-Curb Width: 26.0m (85.3ft),  Out-to-Out Width: 27.1m (88.9ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 74.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0922R,  Location: 08-SBD-015-5.28-RCUC (Lat: 34.106097,  Lng: -117.531897),  Route carried "on" structure: Interstate 15,  Year Built: 1975,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 6.80m (22.31ft),  Average Daily Traffic: 101,500 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 120,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: FOOTHILL BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.280,  Lanes on structure: 5,  Lanes under structure: 8,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 25.8m (84.6ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.0m (114.8ft),  Curb-To-Curb Width: 25.8m (84.6ft),  Out-to-Out Width: 26.6m (87.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0958G,  Location: 08-SBD-210-11.31-RCUC (Lat: 34.135000,  Lng: -117.499783),  Route carried "on" structure: Ramp State highway 210,  Year Built: 1976,  Status: Open,  Structure Length: 3.72m (12.20ft),  Average Daily Traffic: 3,001 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 5,101 (year 2041),  Design Load: HS 20,  Features Intersected: W210-S15 CONNECTOR RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.310,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 36.6m (120.1ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0960L,  Location: 08-SBD-210-11.34-RCUC (Lat: 34.136400,  Lng: -117.498706),  Route carried "on" structure: State highway 210,  Year Built: 2000,  Status: Open,  Structure Length: 4.61m (15.12ft),  Average Daily Traffic: 93,000 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 102,017 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: W210-S15 CONNECTOR RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.340,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 22.3m (73.2ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 46.1m (151.2ft),  Curb-To-Curb Width: 22.3m (73.2ft),  Out-to-Out Width: 23.3m (76.4ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0960R,  Location: 08-SBD-210-11.34-RCUC (Lat: 34.136111,  Lng: -117.498975),  Route carried "on" structure: State highway 210,  Year Built: 2000,  Status: Open,  Structure Length: 4.56m (14.96ft),  Average Daily Traffic: 83,000 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 102,017 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: W210-S15 CONNECTOR RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.340,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 22.0m (72.2ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 45.6m (149.6ft),  Curb-To-Curb Width: 22.0m (72.2ft),  Out-to-Out Width: 23.0m (75.5ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0961,  Location: 08-SBD-210-11.46-RCUC (Lat: 34.136125,  Lng: -117.496803),  Route carried "on" structure: State highway 210,  Year Built: 2001,  Status: Open,  Structure Length: 12.01m (39.40ft),  Average Daily Traffic: 166,000 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 204,033 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: INTERSTATE 15
Minimum Vertical Clearance: 8.28m (27.17ft),  Kilometerpoint: 11.460,  Lanes on structure: 9,  Lanes under structure: 9,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 35.0m (114.8ft),  Skew: 34 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 63.4m (208.0ft),  Curb-To-Curb Width: 59.4m (194.9ft),  Out-to-Out Width: 61.0m (200.1ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0961F,  Location: 08-SBD-210-11.55-RCUC (Lat: 34.138350,  Lng: -117.494050),  Route carried "on" structure: Ramp State highway 210,  Year Built: 1999,  Status: Open,  Structure Length: 11.64m (38.19ft),  Average Daily Traffic: 3,001 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,081 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: INTERSTATE 15
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.550,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 61.0m (200.1ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0964L,  Location: 08-SBD-015-7.56-RCUC (Lat: 34.129561,  Lng: -117.504261),  Route carried "on" structure: Interstate 15,  Year Built: 1976,  Status: Open,  Structure Length: 3.81m (12.50ft),  Average Daily Traffic: 80,000 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 90,000 (year 2040),  Design Load: HS 20,  Features Intersected: EAST ETIWANDA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.560,  Lanes on structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 36.0m (118.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 37.8m (124.0ft),  Curb-To-Curb Width: 32.8m (107.6ft),  Out-to-Out Width: 33.8m (110.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Excellent,  Operating Rating: 65.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 44.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0964R,  Location: 08-SBD-015-7.56-RCUC (Lat: 34.128964,  Lng: -117.504303),  Route carried "on" structure: Interstate 15,  Year Built: 1976,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 4.60m (15.09ft),  Average Daily Traffic: 80,000 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 90,000 (year 2040),  Design Load: HS 20,  Features Intersected: EAST ETIWANDA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.560,  Lanes on structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 29.3m (96.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 45.7m (149.9ft),  Curb-To-Curb Width: 27.5m (90.2ft),  Out-to-Out Width: 28.5m (93.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Excellent,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0965L,  Location: 08-SBD-015-7.44-RCUC (Lat: 34.128144,  Lng: -117.505972),  Route carried "on" structure: Interstate 15,  Year Built: 1976,  Status: Open,  Structure Length: 4.11m (13.48ft),  Average Daily Traffic: 80,000 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 90,000 (year 2040),  Design Load: HS 20,  Features Intersected: VICTORIA STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.440,  Lanes on structure: 5,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 40.5m (132.9ft),  Curb-To-Curb Width: 25.6m (84.0ft),  Out-to-Out Width: 26.7m (87.6ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0965R,  Location: 08-SBD-015-7.44-RCUC (Lat: 34.128142,  Lng: -117.505292),  Route carried "on" structure: Interstate 15,  Year Built: 1976,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 4.11m (13.48ft),  Average Daily Traffic: 80,000 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 90,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: VICTORIA STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.440,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 32.0m (105.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 40.5m (132.9ft),  Curb-To-Curb Width: 27.5m (90.2ft),  Out-to-Out Width: 28.5m (93.5ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0966G,  Location: 08-SBD-210-11.42-RCUC (Lat: 34.134811,  Lng: -117.498394),  Route carried "on" structure: Ramp State highway 210,  Year Built: 1976,  Status: Open,  Structure Length: 11.77m (38.62ft),  Average Daily Traffic: 3,001 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,081 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: INTERSTATE 15
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.420,  Lanes on structure: 2,  Lanes under structure: 9,  Owner: State Highway Agency,  Approaching Roadway Width: 10.5m (34.4ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 59.4m (194.9ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 58.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 23.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0967F,  Location: 08-SBD-015-8.30-RCUC (Lat: 34.134758,  Lng: -117.491789),  Route carried "on" structure: Ramp Interstate 15,  Year Built: 2001,  Status: Open,  Structure Length: 78.15m (256.40ft),  Average Daily Traffic: 4,501 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I15, I210 & CONNECTOR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.300,  Lanes on structure: 2,  Lanes under structure: 26,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 16,  Length of Maximum Span: 51.8m (169.9ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0970L,  Location: 08-SBD-015-8.83-RCUC (Lat: 34.142483,  Lng: -117.488672),  Route carried "on" structure: Interstate 15,  Year Built: 1976,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 7.01m (23.00ft),  Average Daily Traffic: 80,000 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 85,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CHERRY AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.830,  Lanes on structure: 7,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 39.0m (128.0ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 34.7m (113.8ft),  Curb-To-Curb Width: 31.3m (102.7ft),  Out-to-Out Width: 32.3m (106.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0970R,  Location: 08-SBD-015-8.83-RCUC (Lat: 34.141831,  Lng: -117.488672),  Route carried "on" structure: Interstate 15,  Year Built: 1976,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 7.28m (23.88ft),  Average Daily Traffic: 80,000 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 85,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: CHERRY AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.830,  Lanes on structure: 7,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 30.7m (100.7ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.4m (119.4ft),  Curb-To-Curb Width: 30.7m (100.7ft),  Out-to-Out Width: 31.7m (104.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0973L,  Location: 08-SBD-015-5.97-RCUC (Lat: 34.113250,  Lng: -117.523939),  Route carried "on" structure: Interstate 15,  Year Built: 1976,  Status: Open,  Structure Length: 8.11m (26.61ft),  Average Daily Traffic: 88,500 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 100,000 (year 2040),  Design Load: HS 20,  Features Intersected: ETIWANDA AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.970,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 19.9m (65.3ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 19.9m (65.3ft),  Out-to-Out Width: 21.0m (68.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0973R,  Location: 08-SBD-015-5.97-RCUC (Lat: 34.112833,  Lng: -117.523878),  Route carried "on" structure: Interstate 15,  Year Built: 1976,  Status: Open,  Structure Length: 8.26m (27.10ft),  Average Daily Traffic: 88,500 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 100,000 (year 2040),  Design Load: HS 20,  Features Intersected: ETIWANDA AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.970,  Lanes on structure: 4,  Lanes under structure: 9,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 21.2m (69.6ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0974L,  Location: 08-SBD-015-6.71-RCUC (Lat: 34.120844,  Lng: -117.514772),  Route carried "on" structure: Interstate 15,  Year Built: 1976,  Status: Open,  Structure Length: 13.50m (44.29ft),  Average Daily Traffic: 80,000 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 100,000 (year 2040),  Design Load: HS 20,  Features Intersected: BASELINE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.710,  Lanes on structure: 4,  Lanes under structure: 16,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 19.9m (65.3ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 52.4m (171.9ft),  Curb-To-Curb Width: 19.9m (65.3ft),  Out-to-Out Width: 21.0m (68.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0974R,  Location: 08-SBD-015-6.71-RCUC (Lat: 34.120375,  Lng: -117.514761),  Route carried "on" structure: Interstate 15,  Year Built: 1976,  Status: Open,  Structure Length: 17.31m (56.79ft),  Average Daily Traffic: 78,500 (year 2017),  Truck Traffic: 8%,  Average Future Daily Traffic: 100,000 (year 2040),  Design Load: HS 20,  Features Intersected: BASELINE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.710,  Lanes on structure: 4,  Lanes under structure: 14,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 19.9m (65.3ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 39.3m (128.9ft),  Curb-To-Curb Width: 19.9m (65.3ft),  Out-to-Out Width: 21.0m (68.9ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0975S,  Location: 08-SBD-015-6.70-RCUC (Lat: 34.119928,  Lng: -117.514753),  Route carried "on" structure: Ramp Interstate 15,  Year Built: 1976,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 4.24m (13.91ft),  Average Daily Traffic: 14,800 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 28,000 (year 2040),  Design Load: HL 93,  Features Intersected: EAST AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.700,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 21.0m (68.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0978,  Location: 08-SBD-015-9.60-RCUC (Lat: 34.150253,  Lng: -117.479800),  Route carried "on" structure: City street ,  Year Built: 1999,  Status: Open,  Structure Length: 11.98m (39.30ft),  Average Daily Traffic: 5,001 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 8,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: INTERSTATE 15,  Facility Carried by Structure: SUMMIT AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 10,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 64.0m (210.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 23.2m (76.1ft),  Out-to-Out Width: 26.1m (85.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0986L,  Location: 08-SBD-015-3.94-RCUC (Lat: 34.089897,  Lng: -117.544525),  Route carried "on" structure: Interstate 15,  Year Built: 1975,  Status: Open,  Structure Length: 3.51m (11.52ft),  Average Daily Traffic: 98,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 136,200 (year 2042),  Design Load: HS 20,  Features Intersected: MWD PIPELINE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.940,  Lanes on structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 20.4m (66.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 34.7m (113.8ft),  Curb-To-Curb Width: 19.8m (65.0ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 54 0986R,  Location: 08-SBD-015-3.94-RCUC (Lat: 34.089900,  Lng: -117.544203),  Route carried "on" structure: Interstate 15,  Year Built: 1975,  Status: Open,  Structure Length: 3.51m (11.52ft),  Average Daily Traffic: 98,000 (year 2020),  Truck Traffic: 18%,  Average Future Daily Traffic: 136,200 (year 2042),  Design Load: HS 20,  Features Intersected: MWD PIPELINE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.940,  Lanes on structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 21.0m (68.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 34.7m (113.8ft),  Curb-To-Curb Width: 19.8m (65.0ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place