Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Overland Park, Kansas (KS)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 292Number of bridges
  • 3,885ft / 1,184mTotal length
  • $4,147,000Total costs
  • 5,857,841Total average daily traffic
  • 320,778Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Overland Park
  • No street view available for this location

New bridges in Overland Park, KS - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 11920-1929
  • 81950-1959
  • 551960-1969
  • 301970-1979
  • 291980-1989
  • 571990-1999
  • 492000-2009
  • 542010-2019
  • 82020-2022
Reconstructed bridges in Overland Park, KS - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11940-1949
  • 01950-1959
  • 01960-1969
  • 21970-1979
  • 101980-1989
  • 61990-1999
  • 122000-2009
  • 32010-2019
  • 12020-2022
Average Bridge Daily Traffic in Overland Park, KS
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 17.8%Very good
  • 66.9%Good
  • 11.5%Satisfactory
  • 3.8%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 47.1%Very good
  • 38.9%Good
  • 12.7%Satisfactory
  • 1.3%Fair
  • 0.6%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 45.2%Very good
  • 40.8%Good
  • 12.1%Satisfactory
  • 1.3%Fair
  • 0.6%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.2%Very good
  • 46.2%Good
  • 18.5%Satisfactory
  • 2.2%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 19.4%Very good
  • 63.4%Good
  • 14.0%Satisfactory
  • 2.2%Fair
  • 1.1%Poor
Find on map >>   Show street view

Structure Number: 46014,  Location: 1.7W OF STILLWELL (Lat: 38.767267,  Lng: -94.688089),  Route carried "on" structure: County highway 347,  Year Built: 1987,  Status: Open,  Structure Length: 2.13m (6.99ft),  Average Daily Traffic: 2,663 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 5,000 (year 2041),  Design Load: HS 20,  Features Intersected: TRIB. TO WOLF CREEK,  Facility Carried by Structure: 199TH ST. T.9-2.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 61.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 46015,  Location: E. STILLWELL (Lat: 38.767244,  Lng: -94.654892),  Route carried "on" structure: County highway 347,  Year Built: 1987,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 2,654 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 3,200 (year 2041),  Design Load: HS 20,  Features Intersected: TRIB. TO BIG BLUE RIVER,  Facility Carried by Structure: 199TH ST. V.8-2.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 93.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 56.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 46016,  Location: 1.2E 2.8N OF STILLWELL (Lat: 38.807600,  Lng: -94.630489),  Route carried "on" structure: County highway 347,  Year Built: 1990,  Status: Open,  Structure Length: 2.53m (8.30ft),  Average Daily Traffic: 934 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,130 (year 2041),  Design Load: HS 20,  Features Intersected: TRIB. TO BIG BLUE RIVER,  Facility Carried by Structure: MISSION X.0-4.8
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 46017,  Location: 1.2E 4.3N OF STILLWELL (Lat: 38.830678,  Lng: -94.630311),  Route carried "on" structure: County highway 347,  Year Built: 1999,  Status: Open,  Structure Length: 7.56m (24.80ft),  Average Daily Traffic: 1,703 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 2,100 (year 2041),  Design Load: H 15,  Features Intersected: BIG BLUE RIVER,  Facility Carried by Structure: MISSION X.0-6.3
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.0m (82.0ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 75.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 46025,  Location: 0.6W 1.1S OF STILLWELL (Lat: 38.751236,  Lng: -94.667661),  Route carried "on" structure: County highway 1018,  Year Built: 1993,  Status: Open,  Structure Length: 6.62m (21.72ft),  Average Daily Traffic: 1,386 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,800 (year 2041),  Design Load: HS 20,  Features Intersected: UNION PACIFIC RAILROAD,  Facility Carried by Structure: METCALF V.0-0.9
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 46028,  Location: 1.2N 4.0E OF BONITA (Lat: 38.830169,  Lng: -94.742500),  Route carried "on" structure: County highway 1353,  Year Built: 1960,  Status: Posted for load,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 2,772 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 4,000 (year 2041),  Design Load: H 15,  Features Intersected: COFFEE CREEK,  Facility Carried by Structure: PFLUMM R.0-6.2
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 26.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 15.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 12.19m (39.99ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Bridge Improvement Cost: $1,000,000,  Roadway Improvement Cost: $400,000,  Total Project Cost: $1,000,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 46042,  Location: 0.65 MI S OF 167TH ST (Lat: 38.816075,  Lng: -94.666386),  Route carried "on" structure: City street 2242,  Year Built: 1960,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 6.29m (20.64ft),  Average Daily Traffic: 5,000 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 6,000 (year 2040),  Design Load: H 20,  Features Intersected: BIG BLUE RIVER,  Facility Carried by Structure: METCALF AVE.
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.7m (31.8ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 35.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4605,  Location: 1.15S OF 159TH (Lat: 38.823500,  Lng: -94.631131),  Route carried "on" structure: County highway 2714,  Year Built: 2015,  Status: Open,  Structure Length: 3.73m (12.24ft),  Average Daily Traffic: 1,261 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 2,000 (year 2041),  Design Load: HL 93,  Features Intersected: CAMP BRANCH TRIBUTARY,  Facility Carried by Structure: MISSION RD X.0-5.9
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 36.6m (120.1ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 76.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 461097004664,  Location: 0.2 MI SOUTH OF 183RD ST (Lat: 38.793175,  Lng: -94.760828),  Route carried "on" structure: County highway ,  Year Built: 2012,  Status: Open,  Structure Length: 9.95m (32.64ft),  Average Daily Traffic: 1,042 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,300 (year 2041),  Design Load: HS 20,  Features Intersected: WOLF CREEK,  Facility Carried by Structure: LACKMAN RD Q.0-3.8
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 21.9m (71.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 70.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 46109720466,  Location: 0.2 mi east of Lackman (Lat: 38.796478,  Lng: -94.757178),  Route carried "on" structure: County highway ,  Year Built: 2010,  Status: Open,  Structure Length: 1.29m (4.23ft),  Average Daily Traffic: 234 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 300 (year 2041),  Design Load: HS 20,  Features Intersected: Wolf Creek Trib.,  Facility Carried by Structure: 183rd St Q.2-4.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.3m (20.7ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 66.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 461098304618,  Location: Heritage Park,S of 160th (Lat: 38.828453,  Lng: -94.750242),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 0.63m (2.07ft),  Average Daily Traffic: 300 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 400 (year 2041),  Design Load: HS 20,  Features Intersected: Coffee Creek,  Facility Carried by Structure: HALLET ST HP-09-VB
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Local Park, Forest, or Reservation Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 8.0m (26.2ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 40.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 46110370472,  Location: 6.8 E OF SPRINGHILL (Lat: 38.752731,  Lng: -94.692808),  Route carried "on" structure: County highway ,  Year Built: 2001,  Status: Open,  Structure Length: 0.63m (2.07ft),  Average Daily Traffic: 131 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 160 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: CREEK,  Facility Carried by Structure: 207TH ST. T.64-1.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 73.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 461105004701,  Location: 0.5W 0.1S US69 & 199TH. (Lat: 38.766308,  Lng: -94.686289),  Route carried "on" structure: City street ,  Year Built: 1997,  Status: Open,  Structure Length: 0.72m (2.36ft),  Average Daily Traffic: 300 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 500 (year 2040),  Design Load: HS 20,  Features Intersected: N. WOLF CREEK TRIB.,  Facility Carried by Structure: ANTIOCH RD.
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.3m (7.5ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 46.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020
Find on map >>   Show street view

Structure Number: 461105004702,  Location: 8.6W 0.2S OF STILLWELL (Lat: 38.763997,  Lng: -94.686275),  Route carried "on" structure: City street ,  Year Built: 1997,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 300 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 500 (year 2040),  Design Load: HS 20,  Features Intersected: WOLF CREEK TRIB.,  Facility Carried by Structure: ANTIOCH RD.
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 62.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020
Find on map >>   Show street view

Structure Number: 46110560468,  Location: 0.37 W OF METCALF (Lat: 38.781861,  Lng: -94.674731),  Route carried "on" structure: County highway 393,  Year Built: 2015,  Status: Open,  Structure Length: 1.00m (3.28ft),  Average Daily Traffic: 659 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 900 (year 2041),  Design Load: HL 93,  Features Intersected: WOLF CREEK TRIBUTARY,  Facility Carried by Structure: 191st St U.63-3.00
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.9m (16.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 70.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 46110730472,  Location: 8.4 E OF SPRINGHILL (Lat: 38.752689,  Lng: -94.662053),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 0.78m (2.56ft),  Average Daily Traffic: 405 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 500 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: CREEK,  Facility Carried by Structure: 207TH ST. V.3-1.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.5m (8.2ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 62.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 461107704686,  Location: .3N .1 E of 199th & Nall (Lat: 38.772325,  Lng: -94.652556),  Route carried "on" structure: Other road ,  Year Built: 2010,  Status: Open,  Structure Length: 0.78m (2.56ft),  Average Daily Traffic: 106 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 130 (year 2041),  Design Load: HS 20,  Features Intersected: Camp Branch Trib.,  Facility Carried by Structure: LOCUST V.84-2.35
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.8m (25.6ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 77.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 461109104684,  Location: 0.5E 0.6N OF STILLWELL (Lat: 38.775322,  Lng: -94.648092),  Route carried "on" structure: County highway ,  Year Built: 1980,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 5 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 5 (year 2041),  Design Load: H 20,  Features Intersected: CAMP BRANCH CREEK,  Facility Carried by Structure: BIRCH RD. W.1-2.6
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 3.0m (9.8ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Fair,  Culverts: Poor,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Length Of Structure Improvement: 1.37m (4.49ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Bridge Improvement Cost: $150,000,  Roadway Improvement Cost: $55,000,  Total Project Cost: $395,000 ( Estimate for 2021)
Find on map >>   Show street view

Structure Number: 46110920468,  Location: 1.8E OF US-69 (Lat: 38.781889,  Lng: -94.645325),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 5.43m (17.81ft),  Average Daily Traffic: 1,368 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,700 (year 2041),  Design Load: HS 20,  Features Intersected: CAMP BRANCH,  Facility Carried by Structure: 191ST ST. W.3-3.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.9 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 50.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 46110930466,  Location: 0.30 MI. E OF NALL AVE. (Lat: 38.796381,  Lng: -94.643539),  Route carried "on" structure: County highway 21925,  Year Built: 2017,  Status: Open,  Structure Length: 19.64m (64.44ft),  Average Daily Traffic: 1,000 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,200 (year 2041),  Design Load: HL 93,  Features Intersected: UP RR & CAMP BRANCH CRK,  Facility Carried by Structure: 183RD ST W.3-4.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.9m (35.8ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 48.2m (158.1ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 87.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 461111004726,  Location: 1.2E 1.6S OF STILLWELL (Lat: 38.744494,  Lng: -94.630544),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 2.16m (7.09ft),  Average Daily Traffic: 241 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 300 (year 2041),  Design Load: HS 20,  Features Intersected: MASSEY CREEK,  Facility Carried by Structure: MISSION X.0-0.4
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.1m (23.3ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.0m (23.0ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 57.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 46111150472,  Location: 0.5E MISSION ON 207TH. ST (Lat: 38.752658,  Lng: -94.619331),  Route carried "on" structure: County highway ,  Year Built: 1997,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 7 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 50 (year 2041),  Design Load: HS 20,  Features Intersected: MASSEY CREEK TRIB.,  Facility Carried by Structure: 207TH ST. X.61-1.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.5m (11.5ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 90.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 59.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 46111170472,  Location: 0.7E MISSION ON 207TH. ST (Lat: 38.752664,  Lng: -94.616336),  Route carried "on" structure: County highway ,  Year Built: 1997,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 7 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 50 (year 2041),  Design Load: HS 20,  Features Intersected: MASSEY CREEK TRIB.,  Facility Carried by Structure: 207TH ST X.76-1.0
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.8m (28.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 58.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 461113204727,  Location: 2.2E 1.7S OF STILLWELL (Lat: 38.741581,  Lng: -94.609056),  Route carried "on" structure: County highway ,  Year Built: 1992,  Status: Open,  Structure Length: 3.14m (10.30ft),  Average Daily Traffic: 82 (year 2016),  Truck Traffic: 6%,  Average Future Daily Traffic: 100 (year 2041),  Design Load: HS 20,  Features Intersected: MASSEY CREEK,  Facility Carried by Structure: STATE LINE Z.0-0.3
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 90.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 59.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 42195046000004,  Location: 1500' S. OF 119TH ST. (Lat: 38.908758,  Lng: -94.723714),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 25,000 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 30,000 (year 2040),  Design Load: H 20,  Features Intersected: INDIAN CK TRIB,  Facility Carried by Structure: QUIVIRA RD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 23 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.5m (11.5ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Inventory Rating: 74.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 421950460000052,  Location: 250' S. OF 121ST ST. (Lat: 38.907794,  Lng: -94.672797),  Route carried "on" structure: City street 4261,  Year Built: 1966,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 0.68m (2.23ft),  Average Daily Traffic: 26,400 (year 2017),  Truck Traffic: 5%,  Average Future Daily Traffic: 31,700 (year 2040),  Design Load: HS 20,  Features Intersected: TOMAHAWK CK TRIB,  Facility Carried by Structure: BLUE VALLEY PKWY
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 9,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 421950460000261,  Location: 400' N. OF I-35 (Lat: 39.035892,  Lng: -94.686367),  Route carried "on" structure: City street ,  Year Built: 1998,  Status: Open,  Structure Length: 7.72m (25.33ft),  Average Daily Traffic: 19,400 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 23,300 (year 2040),  Design Load: HS 20,  Features Intersected: BNSF RAILROAD,  Facility Carried by Structure: ANTIOCH RD.
Minimum Vertical Clearance: 10.00m (32.81ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.0m (52.5ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 29.0m (95.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 19.4m (63.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 79.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 42195046275103,  Location: 1000' N OF 127TH ST (Lat: 38.900958,  Lng: -94.742400),  Route carried "on" structure: City street 2751,  Year Built: 1992,  Status: Open,  Structure Length: 4.48m (14.70ft),  Average Daily Traffic: 16,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 19,200 (year 2040),  Design Load: HS 20,  Features Intersected: INDIAN CK,  Facility Carried by Structure: PFLUMM RD.
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.1m (56.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 18.7m (61.4ft),  Out-to-Out Width: 28.3m (92.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 76.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 42195046277425,  Location: 250' W OF MASTIN (Lat: 38.985714,  Lng: -94.702186),  Route carried "on" structure: City street 2774,  Year Built: 1966,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 5,600 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 6,700 (year 2040),  Design Load: H 20,  Features Intersected: TURKEY CK TRIB,  Facility Carried by Structure: 79TH ST
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 73.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 421950462801045,  Location: 300' S OF 119TH ST (Lat: 38.912067,  Lng: -94.723736),  Route carried "on" structure: City street 2801,  Year Built: 1984,  Status: Posted for load,  Structure Length: 4.97m (16.31ft),  Average Daily Traffic: 25,000 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 30,000 (year 2040),  Design Load: HS 20,  Features Intersected: INDIAN CK,  Facility Carried by Structure: QUIVIRA RD.
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.5m (64.0ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 22.6m (74.1ft),  Out-to-Out Width: 28.3m (92.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 29.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 421950462801095,  Location: 400' S OF I-435 (Lat: 38.934133,  Lng: -94.723656),  Route carried "on" structure: City street 2801,  Year Built: 1974,  Year Reconstructed: 2012,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 42,900 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 51,500 (year 2040),  Design Load: H 20,  Features Intersected: INDIAN CK N BRANCH,  Facility Carried by Structure: QUIVIRA RD.
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 10,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 3.4m (11.2ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 421950462801507,  Location: 0.7 MI S OF 159TH ST (Lat: 38.818881,  Lng: -94.723719),  Route carried "on" structure: City street 2801,  Year Built: 2021,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 2,000 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 9,000 (year 2041),  Design Load: HL 93,  Features Intersected: COFFEE CREEK TRIB,  Facility Carried by Structure: QUIVIRA RD NB
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.2m (20.3ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.7m (12.1ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 421950462801508,  Location: 0.7 MI S OF 159TH ST (Lat: 38.829903,  Lng: -94.723894),  Route carried "on" structure: City street 2801,  Year Built: 2021,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 9,000 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 9,000 (year 2041),  Design Load: HL 93,  Features Intersected: COFFEE CREEK TRIB,  Facility Carried by Structure: QUIVIRA RD SB
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.0m,  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 61.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 47.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 421950462801511,  Location: 0.2 MI N OF 167TH ST (Lat: 38.826200,  Lng: -94.723633),  Route carried "on" structure: City street 2801,  Year Built: 2020,  Status: Open,  Structure Length: 9.79m (32.12ft),  Average Daily Traffic: 2,000 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 9,000 (year 2041),  Design Load: HL 93,  Features Intersected: COFFEE CREEK,  Facility Carried by Structure: QUIVIRA RD NB
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 5.9m (19.4ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 52.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 421950462801512,  Location: 0.2 MI N OF 167TH ST (Lat: 38.826233,  Lng: -94.723808),  Route carried "on" structure: City street 2801,  Year Built: 2020,  Status: Open,  Structure Length: 9.79m (32.12ft),  Average Daily Traffic: 2,000 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 9,000 (year 2041),  Design Load: HL 93,  Features Intersected: COFFEE CREEK,  Facility Carried by Structure: QUIVIRA RD SB
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 3.7m (12.1ft),  Right: 0.0m,  Curb-To-Curb Width: 6.6m (21.7ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 49.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 421950462801515,  Location: 0.18 MI S OF 167TH ST (Lat: 38.820667,  Lng: -94.723783),  Route carried "on" structure: City street 2801,  Year Built: 2020,  Status: Open,  Structure Length: 0.89m (2.92ft),  Average Daily Traffic: 4,000 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 18,000 (year 2041),  Design Load: HL 93,  Features Intersected: COFFEE CREEK TRIB,  Facility Carried by Structure: QUIVIRA RD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Skew: 21 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.4m (14.4ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 1.5m (4.9ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 95.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 73.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: 421950462824243,  Location: 1100' West of Metcalf (Lat: 38.956700,  Lng: -94.671572),  Route carried "on" structure: City street 1,  Year Built: 2008,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 18,000 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 21,600 (year 2040),  Design Load: HS 20,  Features Intersected: INDIAN CK TRIB NO 3,  Facility Carried by Structure: 95TH ST.
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.6m (15.1ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 1.2m (3.9ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 421950462831255,  Location: 50' S OF MASTIN (Lat: 38.987378,  Lng: -94.702683),  Route carried "on" structure: City street 2831,  Year Built: 1959,  Year Reconstructed: 2010,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 9,400 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 11,300 (year 2040),  Design Load: HS 20,  Features Intersected: TURKEY CK TRIB,  Facility Carried by Structure: FRONTAGE RD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.1m (36.4ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.6m (5.2ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 31.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 18.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 421950462831265,  Location: 900' S OF GRANT CIRCLE (Lat: 38.990972,  Lng: -94.699072),  Route carried "on" structure: City street 2831,  Year Built: 1959,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 13,200 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 15,800 (year 2040),  Design Load: HS 20,  Features Intersected: TURKEY CK TRIB,  Facility Carried by Structure: FRONTAGE RD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 421950462836218,  Location: 0.3 mi. East of Roe (Lat: 38.949408,  Lng: -94.638439),  Route carried "on" structure: City street 1,  Year Built: 2008,  Status: Open,  Structure Length: 0.63m (2.07ft),  Average Daily Traffic: 1,500 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,800 (year 2040),  Design Load: HS 20,  Features Intersected: INDIAN CK TRIB NO 1,  Facility Carried by Structure: 99TH ST.
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.0m

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 56.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 42195046283622,  Location: 200' E OF MARTY (Lat: 38.949464,  Lng: -94.668872),  Route carried "on" structure: City street 2836,  Year Built: 1961,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 0.74m (2.43ft),  Average Daily Traffic: 2,400 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 2,900 (year 2040),  Design Load: H 20,  Features Intersected: INDIAN CK TRIB NO 3,  Facility Carried by Structure: 99TH ST
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.6m (34.8ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft),  Curb or Sidewalk Widths: Left: 2.9m (9.5ft),  Right: 2.9m (9.5ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 42195046285015,  Location: 750' E OF QUIVIRA (Lat: 38.942083,  Lng: -94.720756),  Route carried "on" structure: City street 2850,  Year Built: 1977,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 12,000 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 14,400 (year 2040),  Design Load: H 20,  Features Intersected: INDIAN CK N BRANCH TRIB,  Facility Carried by Structure: 103RD ST
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.1m (6.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 56.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.64m (2.10ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Bridge Improvement Cost: $56,000,  Total Project Cost: $70,000 ( Estimate for 2018)
Find on map >>   Show street view

Structure Number: 42195046285016,  Location: 600' W OF METCALF (Lat: 38.941992,  Lng: -94.669722),  Route carried "on" structure: City street 2850,  Year Built: 1978,  Status: Open,  Structure Length: 5.12m (16.80ft),  Average Daily Traffic: 13,400 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 16,100 (year 2040),  Design Load: HS 20,  Features Intersected: INDIAN CK,  Facility Carried by Structure: 103RD ST
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 22 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 14.6m (47.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 23.8m (78.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Good,  Operating Rating: 76.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 5.12m (16.80ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Bridge Improvement Cost: $40,000,  Total Project Cost: $50,000 ( Estimate for 2018),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Discuss Overland Park, Kansas (KS) on our hugely popular Kansas forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.