Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Frankfort, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 47Number of bridges
  • 203ft / 62.0mTotal length
  • $944,000Total costs
  • 240,750Total average daily traffic
  • 12,913Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Frankfort
  • No street view available for this location

New bridges in Frankfort, IL - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 41970-1979
  • 91980-1989
  • 151990-1999
  • 122000-2009
  • 52010-2019
Reconstructed bridges in Frankfort, IL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 42000-2009
  • 02010-2019
  • 12020-2022
Average Bridge Daily Traffic in Frankfort, IL
Average Bridge Truck Traffic in Frankfort, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 5.9%Excellent
  • 17.6%Very good
  • 35.3%Good
  • 23.5%Satisfactory
  • 5.9%Fair
  • 5.9%Poor
  • 5.9%Critical
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 4.5%Excellent
  • 27.3%Very good
  • 31.8%Good
  • 22.7%Satisfactory
  • 4.5%Fair
  • 4.5%Poor
  • 4.5%Critical
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 59.1%Very good
  • 36.4%Good
  • 4.5%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 2.2%Excellent
  • 31.1%Very good
  • 26.7%Good
  • 28.9%Satisfactory
  • 11.1%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 65.2%Very good
  • 30.4%Good
  • 4.3%Satisfactory
Find on map >>   Show street view

Structure Number: 990118,  Location: 4.7 M S OF US 30 (Lat: 41.447406,  Lng: -87.883883),  Route carried "on" structure: US 45,  Year Built: 1978,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 1.36m (4.46ft),  Average Daily Traffic: 6,250 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 7,577 (year 2032),  Design Load: HS 20,  Features Intersected: N BR PRAIRIE CR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 560.873,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.3m (43.6ft),  Curb-To-Curb Width: 11.8m (38.7ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: September 2019,  Other Special Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 990119,  Location: 5.6 M S OF US 30 (Lat: 41.430625,  Lng: -87.883600),  Route carried "on" structure: US 45,  Year Built: 1978,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 6,250 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 7,577 (year 2032),  Design Load: H 15,  Features Intersected: PRAIRIE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 559.006,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 11.8m (38.7ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 990293,  Location: 2.2 M S OF I-80 (Lat: 41.520831,  Lng: -87.849883),  Route carried "on" structure: US 45,  Year Built: 1991,  Status: Open,  Structure Length: 3.52m (11.55ft),  Average Daily Traffic: 34,000 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 49,349 (year 2032),  Features Intersected: HICKORY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 570.014,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 20 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 16.9m (55.4ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 67.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 99031,  Location: 0.5 M W OF US 45 (Lat: 41.425333,  Lng: -87.892514),  Route carried "on" structure: Other road ,  Year Built: 1992,  Status: Open,  Structure Length: 1.94m (6.36ft),  Average Daily Traffic: 5,100 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 6,169 (year 2032),  Features Intersected: PRAIRIE CREEK,  Facility Carried by Structure: MANHATTAN-MONEE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.950,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.5m (60.7ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Fair,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 58.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.71m (8.89ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $344,000,  Roadway Improvement Cost: $34,000,  Total Project Cost: $516,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 990311,  Location: 1.3 M E OF US 45 (Lat: 41.506822,  Lng: -87.821758),  Route carried "on" structure: US 30,  Year Built: 1995,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 4.85m (15.91ft),  Average Daily Traffic: 18,900 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 16,226 (year 2032),  Design Load: HS 20,  Features Intersected: HICKORY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 220.201,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 33 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.2m (53.1ft),  Curb or Sidewalk Widths: Left: 4.3m (14.1ft),  Right: 0.0m,  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 28.0m (91.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 89.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 59.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2017,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 99301,  Location: 0.5M S MANH-MONEE RD (Lat: 41.418947,  Lng: -87.825342),  Route carried "on" structure: Other road ,  Year Built: 2011,  Status: Open,  Structure Length: 2.42m (7.94ft),  Average Daily Traffic: 425 (year 2019),  Truck Traffic: 11%,  Average Future Daily Traffic: 603 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: FORKED CREEK,  Facility Carried by Structure: 88TH AVE (PEOTONE)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.697,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.9m (78.4ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 993016,  Location: .50 M W CHW 19 (Lat: 41.411344,  Lng: -87.852369),  Route carried "on" structure: County highway ,  Year Built: 2006,  Status: Open,  Structure Length: 0.63m (2.07ft),  Average Daily Traffic: 225 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 167 (year 2038),  Design Load: HS 20,  Features Intersected: S Br Forked Creek,  Facility Carried by Structure: TR-241 (Bruns Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.499,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.3m (10.8ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Gravel,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 993311,  Location: 2 MI E. OF US RTE 45 (Lat: 41.415600,  Lng: -87.843053),  Route carried "on" structure: County highway ,  Year Built: 1990,  Status: Open,  Structure Length: 1.18m (3.87ft),  Average Daily Traffic: 125 (year 2019),  Truck Traffic: 13%,  Average Future Daily Traffic: 268 (year 2032),  Design Load: HS 20,  Features Intersected: BR. OF FORKED CREEK,  Facility Carried by Structure: GOLFVIEW DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.579,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.9m (12.8ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Other
Find on map >>   Show street view

Structure Number: 993337,  Location: APPROX0.5M WOF80THAV (Lat: 41.489675,  Lng: -87.817417),  Route carried "on" structure: Other road ,  Year Built: 1992,  Status: Open,  Structure Length: 0.95m (3.12ft),  Average Daily Traffic: 2,650 (year 2019),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,822 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB HICKORY CREEK,  Facility Carried by Structure: SAUK TRAIL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.704,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 993338,  Location: APPROX0.3MWOFHARLEMA (Lat: 41.487864,  Lng: -87.799228),  Route carried "on" structure: Other road ,  Year Built: 1992,  Status: Open,  Structure Length: 1.69m (5.54ft),  Average Daily Traffic: 1,650 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 2,950 (year 2032),  Design Load: HS 20,  Features Intersected: HICKORY CREEK TRIB A,  Facility Carried by Structure: SAUK TRAIL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.232,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 5.5m (18.0ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 993341,  Location: 0.8 M S.MAN-MONEE RD (Lat: 41.414878,  Lng: -87.844678),  Route carried "on" structure: Other road ,  Year Built: 1993,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 3,050 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 2,347 (year 2032),  Design Load: HS 20,  Features Intersected: BR. FORKED CREEK,  Facility Carried by Structure: CENTER ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.155,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 993375,  Location: 1.9 S MANH-MONEE RD (Lat: 41.398789,  Lng: -87.844411),  Route carried "on" structure: Other road ,  Year Built: 2005,  Status: Open,  Structure Length: 2.33m (7.64ft),  Average Daily Traffic: 2,750 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 4,023 (year 2032),  Design Load: HS 20,  Features Intersected: FORKED CREEK,  Facility Carried by Structure: CENTER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.957,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.0m (75.5ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 993393,  Location: .45M W HARLEM (Lat: 41.484436,  Lng: -87.799083),  Route carried "on" structure: Other road ,  Year Built: 1973,  Status: Open,  Structure Length: 1.05m (3.44ft),  Average Daily Traffic: 8,950 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 20,300 (year 2034),  Design Load: HS 20,  Features Intersected: EAST BRCH HICKORY CK,  Facility Carried by Structure: LARAWAY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 25.250,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.2m (10.5ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 73.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 53.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 993394,  Location: 0.7 MI W. HARLEM (Lat: 41.484453,  Lng: -87.804269),  Route carried "on" structure: Other road ,  Year Built: 1973,  Status: Open,  Structure Length: 0.65m (2.13ft),  Average Daily Traffic: 8,950 (year 2019),  Truck Traffic: 12%,  Average Future Daily Traffic: 20,300 (year 2034),  Features Intersected: WEST BRCH HICKORY CK,  Facility Carried by Structure: LARAWAY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.815,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 993398,  Location: 3.3 MI E US 45 (Lat: 41.426311,  Lng: -87.820814),  Route carried "on" structure: Other road ,  Year Built: 1988,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 5,150 (year 2019),  Truck Traffic: 11%,  Average Future Daily Traffic: 6,504 (year 2032),  Design Load: HS 20,  Features Intersected: FORKED CK. TRIB,  Facility Carried by Structure: MANHATTAN-MONEE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.953,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.3m (7.5ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2021
Find on map >>   Show street view

Structure Number: 994353,  Location: .9 S LARAWAY RD (Lat: 41.473022,  Lng: -87.906558),  Route carried "on" structure: Other road ,  Year Built: 1984,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 550 (year 2019),  Truck Traffic: 3%,  Average Future Daily Traffic: 738 (year 2032),  Design Load: HS 20,  Features Intersected: STREAM,  Facility Carried by Structure: SCHEER ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.223,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.2m (17.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2018,  Deck Structure Type: Other
Find on map >>   Show street view

Structure Number: 994355,  Location: 2.9 MI E OF CEDAR RD (Lat: 41.469525,  Lng: -87.910236),  Route carried "on" structure: County highway ,  Year Built: 1985,  Status: Open,  Structure Length: 1.15m (3.77ft),  Average Daily Traffic: 2,600 (year 2019),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,615 (year 2032),  Design Load: HS 20,  Features Intersected: JACKSON CREEK,  Facility Carried by Structure: Delaney Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.331,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.5m (18.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2018,  Deck Structure Type: Other
Find on map >>   Show street view

Structure Number: 994401,  Location: 1.2 MI E US-45 (Lat: 41.521525,  Lng: -87.826039),  Route carried "on" structure: Other road ,  Year Built: 1984,  Year Reconstructed: 2020,  Status: Open,  Structure Length: 2.80m (9.19ft),  Average Daily Traffic: 10,050 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 13,000 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: UNION DITCH,  Facility Carried by Structure: ST FRANCIS ROAD
Minimum Vertical Clearance: 27.99m (91.83ft),  Kilometerpoint: 2.012,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Very good,  Channel: Very good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.57m (11.71ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Bridge Improvement Cost: $285,000,  Roadway Improvement Cost: $29,000,  Total Project Cost: $428,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 994557,  Location: 0.8 M NO BAKER RD (Lat: 41.465108,  Lng: -87.906278),  Route carried "on" structure: Other road ,  Year Built: 1994,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 550 (year 2019),  Truck Traffic: 3%,  Average Future Daily Traffic: 738 (year 2032),  Design Load: HS 20,  Features Intersected: JACKSON CRK TRIB,  Facility Carried by Structure: SCHEER RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.092,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.1m (43.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Bituminous
Find on map >>   Show street view

Structure Number: 994566,  Location: 0.5 MI N MANH-MONEE (Lat: 41.432925,  Lng: -87.903183),  Route carried "on" structure: Other road ,  Year Built: 2004,  Status: Open,  Structure Length: 0.87m (2.85ft),  Average Daily Traffic: 550 (year 2019),  Truck Traffic: 3%,  Average Future Daily Traffic: 738 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB PRAIRIE CREEK,  Facility Carried by Structure: SCHEER ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.874,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.0m (13.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 994605,  Location: 0.5 MI S OF GORMAN R (Lat: 41.404861,  Lng: -87.863822),  Route carried "on" structure: County highway ,  Year Built: 1985,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 75 (year 2016),  Truck Traffic: 17%,  Average Future Daily Traffic: 101 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: FORKED CREEK,  Facility Carried by Structure: 104TH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.306,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.8m (48.6ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 994606,  Location: 02 M SO MANH MON RD (Lat: 41.422119,  Lng: -87.902994),  Route carried "on" structure: Other road ,  Year Built: 1988,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 50 (year 2008),  Truck Traffic: 40%,  Average Future Daily Traffic: 67 (year 2032),  Design Load: HS 20,  Features Intersected: PRAIRIE CREEK,  Facility Carried by Structure: SCHEER RD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.081,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 994608,  Location: 0.7MI N.MAN-MONEE RD (Lat: 41.435978,  Lng: -87.864450),  Route carried "on" structure: County highway ,  Year Built: 1995,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 75 (year 2016),  Truck Traffic: 17%,  Average Future Daily Traffic: 101 (year 2032),  Design Load: HS 20,  Features Intersected: PRAIRE CREEK,  Facility Carried by Structure: 104TH AV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.814,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 994613,  Location: 2.9 MI E US-45 (Lat: 41.411625,  Lng: -87.827258),  Route carried "on" structure: County highway ,  Year Built: 1999,  Status: Open,  Structure Length: 1.17m (3.84ft),  Average Daily Traffic: 225 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 603 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB FORKED CREEK,  Facility Carried by Structure: BRUNS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.624,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.8m (35.4ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 994626,  Location: 50 FT N US-30 (Lat: 41.506778,  Lng: -87.849539),  Route carried "on" structure: US 45,  Year Built: 1999,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 1.26m (4.13ft),  Average Daily Traffic: 34,000 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 49,349 (year 2032),  Features Intersected: HICKORY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 568.469,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 994629,  Location: 0.8 MI W.US 45 (Lat: 41.439808,  Lng: -87.898308),  Route carried "on" structure: Other road ,  Year Built: 1998,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 75 (year 2020),  Average Future Daily Traffic: 101 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB PRAIRIE CRK,  Facility Carried by Structure: DRALLE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.028,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 99463,  Location: 0.1 MI S STUENKEL RD (Lat: 41.453114,  Lng: -87.864731),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 75 (year 2016),  Truck Traffic: 17%,  Average Future Daily Traffic: 101 (year 2032),  Design Load: HS 20,  Features Intersected: TRIB TO PRAIRIE CRK,  Facility Carried by Structure: 104TH AV
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.883,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 994632,  Location: 0.75 MI N.MANHATTAN- (Lat: 41.432156,  Lng: -87.806153),  Route carried "on" structure: County highway ,  Year Built: 1997,  Status: Open,  Structure Length: 0.66m (2.17ft),  Average Daily Traffic: 575 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 101 (year 2032),  Design Load: HS 20,  Features Intersected: FORKED CREEK,  Facility Carried by Structure: 80TH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.216,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.2m (10.5ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Channel: Satisfactory,  Culverts: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020
Find on map >>   Show street view

Structure Number: 994649,  Location: 2.7 M S OF US 30 (Lat: 41.476961,  Lng: -87.878706),  Route carried "on" structure: US 45,  Year Built: 2008,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 7,550 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 8,180 (year 2032),  Design Load: HS 20,  Features Intersected: JACKSON CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 564.237,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Other
Find on map >>   Show street view

Structure Number: 994657,  Location: 1.1 MI N MAN MONEE R (Lat: 41.442639,  Lng: -87.786936),  Route carried "on" structure: Other road ,  Year Built: 1986,  Status: Open,  Structure Length: 0.62m (2.03ft),  Average Daily Traffic: 2,150 (year 2019),  Truck Traffic: 14%,  Average Future Daily Traffic: 2,682 (year 2032),  Design Load: HS 20,  Features Intersected: FORKED CREEK,  Facility Carried by Structure: HARLEM AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.042,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.7m (8.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2019,  Deck Structure Type: Other
Find on map >>   Show street view

Structure Number: 994662,  Location: 0.64 M E OF WOLF (Lat: 41.503150,  Lng: -87.876214),  Route carried "on" structure: US 30,  Year Built: 2012,  Status: Open,  Structure Length: 0.87m (2.85ft),  Average Daily Traffic: 24,700 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 25,300 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: HICKORY CR TRIB #2
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 215.566,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.0m (13.1ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: 994663,  Location: 4.5M E.US 45 (Lat: 41.441186,  Lng: -87.790981),  Route carried "on" structure: Other road ,  Year Built: 2009,  Status: Open,  Structure Length: 1.29m (4.23ft),  Average Daily Traffic: 175 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 101 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: BR OF FORKED CREEK,  Facility Carried by Structure: DRALLE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.975,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2019,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 994664,  Location: 3.9 MILES E. OF US45 (Lat: 41.440983,  Lng: -87.808381),  Route carried "on" structure: Other road ,  Year Built: 2011,  Status: Open,  Structure Length: 1.38m (4.53ft),  Average Daily Traffic: 350 (year 2019),  Truck Traffic: 13%,  Average Future Daily Traffic: 268 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: TRIB OF FORKED CREEK,  Facility Carried by Structure: DRALLE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.527,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 99601,  Location: 0.56 MI S LARAWAY RD (Lat: 41.476022,  Lng: -87.887422),  Route carried "on" structure: Other road ,  Year Built: 2003,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 3,700 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,749 (year 2032),  Features Intersected: JACKSON CREEK,  Facility Carried by Structure: WOLF ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.932,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 2.8m (9.2ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 996011,  Location: 0.15 MI N OF US 30 (Lat: 41.505506,  Lng: -87.876450),  Route carried "on" structure: City street ,  Year Built: 1995,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 225 (year 2019),  Truck Traffic: 16%,  Average Future Daily Traffic: 146 (year 2032),  Features Intersected: HICKORY CREEK TRIB,  Facility Carried by Structure: S WALNUT RIDGE CT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.209,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 996012,  Location: 0.14 S OF LARAWAY RD (Lat: 41.481828,  Lng: -87.900931),  Route carried "on" structure: City street ,  Year Built: 2002,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 225 (year 2019),  Truck Traffic: 16%,  Average Future Daily Traffic: 414 (year 2032),  Features Intersected: RET POND CONNECT CUL,  Facility Carried by Structure: LEDGESTONE WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.225,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 1.7m (5.6ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 996013,  Location: 0.45 MI S OF LARAWAY (Lat: 41.476892,  Lng: -87.897153),  Route carried "on" structure: City street ,  Year Built: 2003,  Status: Open,  Structure Length: 0.65m (2.13ft),  Average Daily Traffic: 1,800 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,146 (year 2032),  Features Intersected: RET POND CONNECT CUL,  Facility Carried by Structure: 116TH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.577,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.6m (28.2ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 2.4m (7.9ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 996014,  Location: 0.01 M N OF IRONWOOD (Lat: 41.510992,  Lng: -87.869433),  Route carried "on" structure: City street ,  Year Built: 1980,  Status: Posted for load,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 275 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 280 (year 2032),  Features Intersected: HICKORY CREEK TRIB,  Facility Carried by Structure: STONEBRIDGE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.772,  Lanes on structure: 2,  Owner: Private,  Approaching Roadway Width: 7.8m (25.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 7.8m (25.6ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Deck: Critical,  Superstructure: Critical,  Substructure: Very good,  Channel: Good,  Operating Rating: 29.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 15.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of replacement,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 6 months,  Inspection Date: June 2020,  Other Special Inspection Date: December 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 996015,  Location: 0.6MI S LARAWAY RD (Lat: 41.475892,  Lng: -87.816014),  Route carried "on" structure: City street ,  Year Built: 2002,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 250 (year 2019),  Truck Traffic: 10%,  Average Future Daily Traffic: 671 (year 2032),  Features Intersected: HICKORY CREEK TRIB,  Facility Carried by Structure: MADELINE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.386,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft)

Condition: Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2020,  Deck Structure Type: Other
Find on map >>   Show street view

Structure Number: 996016,  Location: 0.1 M W OF HARLEM (Lat: 41.469869,  Lng: -87.792744),  Route carried "on" structure: Other road ,  Year Built: 2000,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 2,500 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 2,146 (year 2032),  Features Intersected: HICKORY CREEK TRIB,  Facility Carried by Structure: STEGER ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.950,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.2m (10.5ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2018,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 996017,  Location: 0.3 MI W OF HARLEM (Lat: 41.494019,  Lng: -87.795786),  Route carried "on" structure: County highway ,  Year Built: 1980,  Status: Open,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 900 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,353 (year 2032),  Features Intersected: Hickory Creek Trib,  Facility Carried by Structure: TR-1572 Aberdeen R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.317,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.9m (58.7ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 46.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 12.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: April 2020,  Other Special Inspection Date: April 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss Frankfort, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.