Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Eagle Pass, Texas (TX)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 51Number of bridges
  • 1,220ft / 372mTotal length
  • 338,740Total average daily traffic
  • 28,747Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Eagle Pass
  • No street view available for this location

New bridges in Eagle Pass, TX - historical statistics
  • New bridges - historical statistics
  • 31920-1929
  • 31940-1949
  • 31950-1959
  • 31960-1969
  • 41970-1979
  • 81980-1989
  • 61990-1999
  • 32000-2009
  • 182010-2019
Reconstructed bridges in Eagle Pass, TX - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21940-1949
  • 01950-1959
  • 01960-1969
  • 41970-1979
  • 11980-1989
  • 51990-1999
  • 42000-2009
  • 12010-2019
Average Bridge Daily Traffic in Eagle Pass, TX
Average Bridge Truck Traffic in Eagle Pass, TX
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 3.8%Very good
  • 53.8%Good
  • 38.5%Satisfactory
  • 3.8%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 26.9%Very good
  • 46.2%Good
  • 23.1%Satisfactory
  • 3.8%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 7.7%Very good
  • 76.9%Good
  • 11.5%Satisfactory
  • 3.8%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 4.7%Very good
  • 62.8%Good
  • 32.6%Satisfactory
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 47.6%Good
  • 42.9%Satisfactory
  • 9.5%Fair
Find on map >>   Show street view

Structure Number: 221590027601019,  Location: 2.40 MI NE OF US 277 (Lat: 28.737433,  Lng: -100.446736),  Route carried "on" structure: US 57,  Year Built: 1941,  Year Reconstructed: 1981,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 7,580 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 11,740 (year 2033),  Design Load: H 15,  Features Intersected: SECO CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.780,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 1.8m (5.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 26.0m (85.3ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 221590027609095,  Location: 0.33 MI S OF US 57 (Lat: 28.704464,  Lng: -100.473600),  Route carried "on" structure: State highway 3443,  Year Built: 1992,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 5.40m (17.72ft),  Average Daily Traffic: 17,045 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 25,850 (year 2033),  Design Load: HS 20,  Features Intersected: DRAIN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.595,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 16,  Length of Maximum Span: 2.1m (6.9ft),  Curb or Sidewalk Widths: Left: 2.2m (7.2ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 24.2m (79.4ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 221590027609096,  Location: 1.2 MI S OF SH 57 (Lat: 28.692275,  Lng: -100.473717),  Route carried "on" structure: State highway 3443,  Year Built: 1992,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 1.59m (5.22ft),  Average Daily Traffic: 17,045 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 25,850 (year 2033),  Design Load: HS 20,  Features Intersected: DRAIN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.936,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 2.4m (7.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 24.0m (78.7ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 221590029904065,  Location: 0.3 M E OF US 277 BUS (Lat: 28.738283,  Lng: -100.491175),  Route carried "on" structure: US 277,  Year Built: 2010,  Status: Open,  Structure Length: 32.19m (105.61ft),  Average Daily Traffic: 8,560 (year 2013),  Truck Traffic: 6%,  Average Future Daily Traffic: 11,990 (year 2033),  Design Load: HS 25 or greater,  Features Intersected: UPRR TURNAROUNDS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 48.573,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 9,  Length of Maximum Span: 48.8m (160.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 221590029904066,  Location: 0.3 MI E OF US 277 BUS (Lat: 28.738242,  Lng: -100.491314),  Route carried "on" structure: US 277,  Year Built: 2009,  Status: Open,  Structure Length: 32.19m (105.61ft),  Average Daily Traffic: 8,560 (year 2013),  Truck Traffic: 6%,  Average Future Daily Traffic: 11,990 (year 2033),  Design Load: HS 25 or greater,  Features Intersected: UPRR TURNAROUNDS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 48.573,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 9,  Length of Maximum Span: 48.8m (160.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 221590029913044,  Location: 0.8 MI E OF FM 1021 (Lat: 28.708558,  Lng: -100.496992),  Route carried "on" structure: Business State highway 277,  Year Built: 1928,  Year Reconstructed: 1953,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 7,020 (year 2013),  Truck Traffic: 26%,  Average Future Daily Traffic: 9,830 (year 2033),  Features Intersected: EAGLE PASS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.851,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 17.0m (55.8ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 221590029914074,  Location: 2.8 MI S OF US 277 (Lat: 28.670233,  Lng: -100.452469),  Route carried "on" structure: State highway 480,  Year Built: 2012,  Status: Open,  Structure Length: 7.16m (23.49ft),  Average Daily Traffic: 3,782 (year 2016),  Truck Traffic: 12%,  Average Future Daily Traffic: 5,300 (year 2036),  Design Load: HL 93,  Features Intersected: DRAW NO 3
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.924,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 221590029914075,  Location: 2.8 MI S OF US 277 (Lat: 28.670003,  Lng: -100.452036),  Route carried "on" structure: Ramp State highway 480,  Year Built: 2010,  Status: Open,  Structure Length: 7.01m (23.00ft),  Average Daily Traffic: 3,610 (year 2013),  Truck Traffic: 9%,  Average Future Daily Traffic: 5,050 (year 2033),  Design Load: HL 93,  Features Intersected: DRAW NO 3
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.958,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 221590029914076,  Location: 2.8 MI S OF US 277 (Lat: 28.670694,  Lng: -100.452300),  Route carried "on" structure: Ramp State highway 480,  Year Built: 2010,  Status: Open,  Structure Length: 7.01m (23.00ft),  Average Daily Traffic: 3,610 (year 2013),  Truck Traffic: 9%,  Average Future Daily Traffic: 5,050 (year 2033),  Design Load: HL 93,  Features Intersected: DRAW NO 3
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.913,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 6.9m (22.6ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 221590029914079,  Location: 1.5 MI S OF US 277 (Lat: 28.686347,  Lng: -100.439947),  Route carried "on" structure: Ramp State highway 480,  Year Built: 2010,  Status: Open,  Structure Length: 8.69m (28.51ft),  Average Daily Traffic: 3,782 (year 2016),  Truck Traffic: 12%,  Average Future Daily Traffic: 5,300 (year 2036),  Design Load: HL 93,  Features Intersected: MAVERICK CO CANAL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.745,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 1,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 22159002991408,  Location: 0.35 MI N OF US 277 (Lat: 28.710183,  Lng: -100.431600),  Route carried "on" structure: Ramp State highway 480,  Year Built: 2010,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 2,545 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 5,050 (year 2033),  Design Load: HL 93,  Features Intersected: DRAW NO 4
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.534,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 11.2m (36.7ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 221590029914081,  Location: 0.35 MI N OF US 277 (Lat: 28.710450,  Lng: -100.431925),  Route carried "on" structure: State highway 480,  Year Built: 2010,  Status: Open,  Structure Length: 3.35m (10.99ft),  Average Daily Traffic: 2,545 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 5,300 (year 2036),  Design Load: HL 93,  Features Intersected: DRAW NO 4
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.788,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 13.0m (42.7ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 221590029914083,  Location: 0.35 MI N OF US 277 (Lat: 28.710575,  Lng: -100.432081),  Route carried "on" structure: Ramp State highway 480,  Year Built: 2010,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 2,545 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 5,050 (year 2033),  Design Load: HL 93,  Features Intersected: DRAW NO 4
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.776,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 6.9m (22.6ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 221590029914085,  Location: 0.65 MI N OF US 277 (Lat: 28.715767,  Lng: -100.432056),  Route carried "on" structure: State highway 480,  Year Built: 2010,  Status: Open,  Structure Length: 6.10m (20.01ft),  Average Daily Traffic: 2,545 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,710 (year 2036),  Design Load: HL 93,  Features Intersected: DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.187,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 24.4m (80.1ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 221590029914087,  Location: 3.0 MI S OF US 277 (Lat: 28.668700,  Lng: -100.454367),  Route carried "on" structure: State highway 480,  Year Built: 2012,  Status: Open,  Structure Length: 12.80m (41.99ft),  Average Daily Traffic: 3,610 (year 2013),  Truck Traffic: 9%,  Average Future Daily Traffic: 5,050 (year 2033),  Design Load: HL 93,  Features Intersected: FM 1021
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 25.120,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 4,  Length of Maximum Span: 38.1m (125.0ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 221590029914088,  Location: 0.3 MI S OF INTL BRDGE 2 (Lat: 28.694236,  Lng: -100.506936),  Route carried "on" structure: State highway 480,  Year Built: 2012,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 2,190 (year 2013),  Truck Traffic: 15%,  Average Future Daily Traffic: 3,070 (year 2033),  Design Load: HL 93,  Features Intersected: DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 33.173,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.0m (82.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020
Find on map >>   Show street view

Structure Number: 221590029914091,  Location: 1.75 MI S OF US 277 (Lat: 28.682825,  Lng: -100.441364),  Route carried "on" structure: State highway 480,  Year Built: 2010,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 3,610 (year 2013),  Truck Traffic: 9%,  Average Future Daily Traffic: 5,050 (year 2033),  Design Load: HS 20,  Features Intersected: DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.194,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2020
Find on map >>   Show street view

Structure Number: 221590030001002,  Location: 0.2 MI E OF FM 3443 (Lat: 28.708978,  Lng: -100.473672),  Route carried "on" structure: US 57,  Year Built: 1926,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 16,881 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 34,670 (year 2036),  Design Load: H 15,  Features Intersected: DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.205,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 1.5m (4.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 26.9m (88.3ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 221590030001003,  Location: 2.5 MI SE OF US 57 (Lat: 28.705661,  Lng: -100.425081),  Route carried "on" structure: US 277,  Year Built: 1926,  Year Reconstructed: 1953,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 10,348 (year 2020),  Truck Traffic: 19%,  Average Future Daily Traffic: 19,820 (year 2036),  Design Load: H 15,  Features Intersected: DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 54.591,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 1.5m (4.9ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 221590030001022,  Location: 0.1 MI W OF FM 1021 (Lat: 28.706017,  Lng: -100.501914),  Route carried "on" structure: US 57,  Year Built: 1957,  Year Reconstructed: 1979,  Status: Open,  Structure Length: 3.66m (12.01ft),  Average Daily Traffic: 10,725 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 16,710 (year 2033),  Design Load: HS 20,  Features Intersected: EAGLE PASS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.271,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 22.6m (74.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 62.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 221590030001023,  Location: 0.01 MI E OF FM 1021 (Lat: 28.706131,  Lng: -100.496642),  Route carried "on" structure: US 57,  Year Built: 1983,  Status: Open,  Structure Length: 34.75m (114.01ft),  Average Daily Traffic: 13,055 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 16,710 (year 2033),  Design Load: HS 20,  Features Intersected: UPRR; CEYLON & PIERCE ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.297,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 14,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 23.8m (78.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 221590030001025,  Location: AT JCT US 277 & SL 480 (Lat: 28.705825,  Lng: -100.431831),  Route carried "on" structure: State highway 480,  Year Built: 2010,  Status: Open,  Structure Length: 43.59m (143.01ft),  Average Daily Traffic: 3,610 (year 2013),  Truck Traffic: 9%,  Average Future Daily Traffic: 5,050 (year 2033),  Design Load: HL 93,  Features Intersected: US 277
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.972,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 13,  Length of Maximum Span: 35.4m (116.1ft),  Curb-To-Curb Width: 13.3m (43.6ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 221590122901011,  Location: 0.05 MI N OF US 57 (Lat: 28.706558,  Lng: -100.500617),  Route carried "on" structure: State highway 1021,  Year Built: 1953,  Status: Open,  Structure Length: 4.63m (15.19ft),  Average Daily Traffic: 3,935 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 6,790 (year 2033),  Design Load: H 15,  Features Intersected: EAGLE PASS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.188,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 12.7m (41.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 221590122901016,  Location: 2.7 MI SE OF SP 240 (Lat: 28.683192,  Lng: -100.469694),  Route carried "on" structure: State highway 1021,  Year Built: 1987,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 26,483 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 32,600 (year 2033),  Design Load: HS 20,  Features Intersected: DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.400,  Lanes on structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 2.1m (6.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 19.7m (64.6ft),  Out-to-Out Width: 23.9m (78.4ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 221590122901018,  Location: 1.3 MI S OF FM 3443 (Lat: 28.673086,  Lng: -100.458428),  Route carried "on" structure: State highway 1021,  Year Built: 1993,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 28,712 (year 2019),  Truck Traffic: 6%,  Average Future Daily Traffic: 45,080 (year 2036),  Design Load: HS 20,  Features Intersected: DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.871,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 1.5m (4.9ft),  Curb-To-Curb Width: 21.1m (69.2ft),  Out-to-Out Width: 26.3m (86.3ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2018,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 221590122901023,  Location: 1.8 MI SE OF FM 3443 (Lat: 28.668175,  Lng: -100.453036),  Route carried "on" structure: State highway 1021,  Year Built: 2001,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 26,483 (year 2020),  Truck Traffic: 22%,  Average Future Daily Traffic: 45,080 (year 2036),  Design Load: HS 20,  Features Intersected: DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.721,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 26.9m (88.3ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2018,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 221590122901024,  Location: 0.9 MI W OF FM 375 (Lat: 28.702883,  Lng: -100.498308),  Route carried "on" structure: State highway 1021,  Year Built: 2014,  Status: Open,  Structure Length: 23.38m (76.71ft),  Average Daily Traffic: 17,573 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 20,320 (year 2036),  Design Load: HL 93,  Features Intersected: UNION PACIFIC RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.099,  Lanes on structure: 4,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 6,  Length of Maximum Span: 51.2m (168.0ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 0.0m,  Curb-To-Curb Width: 17.2m (56.4ft),  Out-to-Out Width: 20.2m (66.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 221590150802002,  Location: 0.3 MI E OF US 277 (Lat: 28.719853,  Lng: -100.472078),  Route carried "on" structure: State highway 216,  Year Built: 2006,  Status: Open,  Structure Length: 5.79m (19.00ft),  Average Daily Traffic: 1,000 (year 2010),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,400 (year 2030),  Design Load: HS 25 or greater,  Features Intersected: MAVERICK CO WCID IRR CAN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.438,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 21.3m (69.9ft),  Out-to-Out Width: 25.9m (85.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 55.3 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 221590B00010001,  Location: 0.70 MI SW OF FM 1021 (Lat: 28.698239,  Lng: -100.507550),  Route carried "on" structure: Other road ,  Year Built: 1999,  Status: Open,  Structure Length: 40.02m (131.30ft),  Average Daily Traffic: 11,200 (year 2010),  Average Future Daily Traffic: 24,278 (year 2028),  Design Load: HS 20,  Features Intersected: RIO GRANDE RIVER,  Facility Carried by Structure: SOUTH ADAMS ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Toll: Toll bridge,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 24.7m (81.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 13,  Number Of Approach Spans: 1,  Length of Maximum Span: 30.8m (101.0ft),  Curb or Sidewalk Widths: Left: 1.3m (4.3ft),  Right: 1.3m (4.3ft),  Curb-To-Curb Width: 21.9m (71.9ft),  Out-to-Out Width: 25.6m (84.0ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2019,  Underwater Inspection Date: January 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 221590B00065001,  Location: 0.8 MI S OF VETERANS BLVD (Lat: 28.723250,  Lng: -100.483367),  Route carried "on" structure: City street ,  Year Built: 2011,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 1,000 (year 2012),  Average Future Daily Traffic: 1,200 (year 2030),  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: BIBB AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.381,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.3m (4.3ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 16.6m (54.5ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 221590B00135001,  Location: 0.2 MI N OF FM 1021 (Lat: 28.705778,  Lng: -100.499267),  Route carried "on" structure: City street ,  Year Built: 1982,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 2,414 (year 2018),  Average Future Daily Traffic: 4,500 (year 2030),  Design Load: HS 20,  Features Intersected: EAGLE PASS CREEK,  Facility Carried by Structure: CEYLON ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb or Sidewalk Widths: Left: 0.8m (2.6ft),  Right: 1.1m (3.6ft),  Curb-To-Curb Width: 10.2m (33.5ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 221590B00145001,  Location: 0.1 MI W OF LP 3443 (Lat: 28.697844,  Lng: -100.475186),  Route carried "on" structure: City street ,  Year Built: 1997,  Status: Posted for load,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 1,450 (year 2010),  Average Future Daily Traffic: 4,950 (year 2028),  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: CHERRY LEAF DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 1.2m (3.9ft),  Curb or Sidewalk Widths: Left: 1.3m (4.3ft),  Right: 0.0m,  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 221590B00175001,  Location: 0.1 MI S OF 5TH ST (Lat: 28.720742,  Lng: -100.494583),  Route carried "on" structure: City street ,  Year Built: 1970,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 2.38m (7.81ft),  Average Daily Traffic: 4,050 (year 2010),  Average Future Daily Traffic: 10,500 (year 2028),  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: CONCHO ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 7 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 16.5m (54.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 221590B00200001,  Location: 0.10 MI W OF LP 3443 (Lat: 28.693983,  Lng: -100.474589),  Route carried "on" structure: City street ,  Year Built: 1998,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 1,750 (year 2010),  Average Future Daily Traffic: 4,500 (year 2028),  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: DELLCREST DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.4m (7.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 221590B00205008,  Location: 0.1 MI N OF FM 1021 (Lat: 28.703392,  Lng: -100.496375),  Route carried "on" structure: City street ,  Year Built: 1978,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 191 (year 2018),  Average Future Daily Traffic: 2,900 (year 2030),  Design Load: H 15,  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: CROCKETT ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 221590B00250001,  Location: 0.05 MI W OF MEDINA ST (Lat: 28.715322,  Lng: -100.496531),  Route carried "on" structure: City street ,  Year Built: 1960,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 4,254 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 7,869 (year 2035),  Design Load: HS 20,  Features Intersected: EAGLE PASS CREEK,  Facility Carried by Structure: FERRY ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 10.2m (33.5ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 221590B00260005,  Location: 0.05 MI W OF CONCHO ST (Lat: 28.718261,  Lng: -100.495081),  Route carried "on" structure: City street ,  Year Built: 1978,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 247 (year 2018),  Average Future Daily Traffic: 1,200 (year 2028),  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: FIRST ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 221590B00290001,  Location: 0.37 MI W OF FM 1021 (Lat: 28.705806,  Lng: -100.506775),  Route carried "on" structure: Other road ,  Year Built: 1954,  Year Reconstructed: 1985,  Status: Open,  Structure Length: 56.54m (185.50ft),  Average Daily Traffic: 9,540 (year 2010),  Average Future Daily Traffic: 24,400 (year 2028),  Design Load: HS 20,  Features Intersected: RIO GRANDE RIVER,  Facility Carried by Structure: GARRISON ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Toll: Toll bridge,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 17,  Number Of Approach Spans: 12,  Length of Maximum Span: 23.2m (76.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: October 2019,  Underwater Inspection Date: January 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 221590B00455001,  Location: 0.01 MI N OF FERRY ST (Lat: 28.715608,  Lng: -100.495653),  Route carried "on" structure: City street ,  Year Built: 1960,  Year Reconstructed: 1979,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 1,758 (year 2018),  Average Future Daily Traffic: 3,010 (year 2030),  Features Intersected: EAGLE PASS CREEK,  Facility Carried by Structure: MEDINA ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 11.4m (37.4ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 221590B00510001,  Location: 0.05 MI N OF FM 1021 (Lat: 28.703575,  Lng: -100.497994),  Route carried "on" structure: City street ,  Year Built: 1983,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 3,241 (year 2018),  Average Future Daily Traffic: 9,900 (year 2028),  Design Load: H 15,  Features Intersected: DRAINAGE DITCH,  Facility Carried by Structure: PIERCE ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 221590B00510002,  Location: 0.2 MI N OF FM 1021 (Lat: 28.705933,  Lng: -100.497939),  Route carried "on" structure: City street ,  Year Built: 1983,  Status: Open,  Structure Length: 2.44m (8.01ft),  Average Daily Traffic: 4,700 (year 2010),  Average Future Daily Traffic: 9,900 (year 2028),  Features Intersected: EAGLE PASS CREEK,  Facility Carried by Structure: PIERCE ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss Eagle Pass, Texas (TX) on our hugely popular Texas forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.