Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Burbank, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 67Number of bridges
  • 768ft / 234mTotal length
  • 4,574,634Total average daily traffic
  • 266,593Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Burbank
  • No street view available for this location

New bridges in Burbank, CA - historical statistics
  • New bridges - historical statistics
  • 31930-1939
  • 41940-1949
  • 231950-1959
  • 221960-1969
  • 71970-1979
  • 51980-1989
  • 11990-1999
  • 12000-2009
  • 12010-2019
Reconstructed bridges in Burbank, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 11960-1969
  • 11970-1979
  • 01980-1989
  • 01990-1999
  • 72000-2009
  • 42010-2019
  • 32020-2022
Average Bridge Daily Traffic in Burbank, CA
Average Bridge Truck Traffic in Burbank, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 74.3%Good
  • 25.7%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 91.4%Good
  • 8.6%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 94.3%Good
  • 2.9%Satisfactory
  • 2.9%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 26.7%Excellent
  • 66.7%Very good
  • 6.7%Good
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 83.3%Good
  • 16.7%Satisfactory
Find on map >>   Show street view

Structure Number: 53 1081,  Location: 07-LA-005-28.14-GNDL (Lat: 34.167572,  Lng: -118.300147),  Route carried "on" structure: Interstate 5,  Year Built: 1957,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 1.97m (6.46ft),  Average Daily Traffic: 239,010 (year 2010),  Truck Traffic: 8%,  Average Future Daily Traffic: 244,500 (year 2037),  Design Load: HS 20,  Features Intersected: ALLEN AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.140,  Lanes on structure: 10,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 53.6m (175.9ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.7m (61.4ft),  Curb-To-Curb Width: 53.6m (175.9ft),  Out-to-Out Width: 55.2m (181.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 24.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1082K,  Location: 07-LA-005-28.43-BRB (Lat: 34.170014,  Lng: -118.304325),  Route carried "on" structure: Ramp Interstate 5,  Year Built: 1957,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 3.25m (10.66ft),  Average Daily Traffic: 7,805 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 9,615 (year 2037),  Design Load: HS 20,  Features Intersected: ALAMEDA AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.430,  Lanes on structure: 2,  Lanes under structure: 5,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 8.6m (28.2ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 15.6m (51.2ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 52.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: November 2020,  Other Special Inspection Date: September 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1082L,  Location: 07-LA-005-28.43-BRB (Lat: 34.170153,  Lng: -118.304175),  Route carried "on" structure: Interstate 5,  Year Built: 1957,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 3.25m (10.66ft),  Average Daily Traffic: 119,500 (year 2009),  Truck Traffic: 8%,  Average Future Daily Traffic: 122,029 (year 2042),  Design Load: HS 20,  Features Intersected: ALAMEDA AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.430,  Lanes on structure: 4,  Lanes under structure: 5,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 19.7m (64.6ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 15.6m (51.2ft),  Curb-To-Curb Width: 19.7m (64.6ft),  Out-to-Out Width: 20.6m (67.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 52.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: November 2020,  Other Special Inspection Date: September 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1082R,  Location: 07-LA-005-28.43-BRB (Lat: 34.170289,  Lng: -118.304039),  Route carried "on" structure: Interstate 5,  Year Built: 1957,  Year Reconstructed: 2020,  Status: Open,  Structure Length: 3.25m (10.66ft),  Average Daily Traffic: 254,684 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 258,686 (year 2037),  Design Load: HS 20,  Features Intersected: ALAMEDA AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.430,  Lanes on structure: 12,  Lanes under structure: 5,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 44.4m (145.7ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 15.6m (51.2ft),  Curb-To-Curb Width: 44.4m (145.7ft),  Out-to-Out Width: 45.9m (150.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 52.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: November 2020,  Other Special Inspection Date: September 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1082S,  Location: 07-LA-005-28.43-BRB (Lat: 34.170386,  Lng: -118.303931),  Route carried "on" structure: Bypass Interstate 5,  Year Built: 1957,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 3.25m (10.66ft),  Average Daily Traffic: 8,010 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 9,830 (year 2037),  Design Load: HS 20,  Features Intersected: ALAMEDA AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.430,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 8.6m (28.2ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 15.6m (51.2ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 52.8 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: November 2020,  Other Special Inspection Date: September 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1085L,  Location: 07-LA-005-28.70-BRB (Lat: 34.173619,  Lng: -118.306517),  Route carried "on" structure: Interstate 5,  Year Built: 1959,  Year Reconstructed: 2020,  Status: Open,  Structure Length: 22.25m (73.00ft),  Average Daily Traffic: 119,510 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 119,620 (year 2037),  Design Load: HS 20,  Features Intersected: METROLINK,UP RR,AMTRAK,
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.700,  Lanes on structure: 5,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 27.9m (91.5ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 33.4m (109.6ft),  Curb-To-Curb Width: 27.9m (91.5ft),  Out-to-Out Width: 28.8m (94.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 48.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: December 2020,  Other Special Inspection Date: June 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1085R,  Location: 07-LA-005-28.70-BRB (Lat: 34.173403,  Lng: -118.306214),  Route carried "on" structure: Interstate 5,  Year Built: 1959,  Year Reconstructed: 2020,  Status: Open,  Structure Length: 22.56m (74.02ft),  Average Daily Traffic: 119,510 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 119,620 (year 2037),  Design Load: HS 20,  Features Intersected: METROLINK,UP RR,AMTRAK,
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.700,  Lanes on structure: 5,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 28.2m (92.5ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 33.4m (109.6ft),  Curb-To-Curb Width: 29.1m (95.5ft),  Out-to-Out Width: 30.0m (98.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 43.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: December 2020,  Other Special Inspection Date: June 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1086,  Location: 07-LA-005-28.92-BRB (Lat: 34.176697,  Lng: -118.307678),  Route carried "on" structure: Interstate 5,  Year Built: 1959,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 2.53m (8.30ft),  Average Daily Traffic: 239,020 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 239,240 (year 2037),  Design Load: HS 20,  Features Intersected: VERDUGO AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 28.920,  Lanes on structure: 10,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 56.1m (184.1ft),  Skew: 31 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 24.1m (79.1ft),  Curb-To-Curb Width: 56.1m (184.1ft),  Out-to-Out Width: 57.6m (189.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1087,  Location: 07-LA-005-29.16-BRB (Lat: 34.177847,  Lng: -118.311864),  Route carried "on" structure: City street L426,  Year Built: 1959,  Status: Open,  Structure Length: 7.86m (25.79ft),  Average Daily Traffic: 39,854 (year 2011),  Truck Traffic: 1%,  Average Future Daily Traffic: 52,363 (year 2037),  Design Load: HS 20,  Features Intersected: ROUTE 5 & OLIVE AVE,  Facility Carried by Structure: OLIVE AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 10,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 27.7m (90.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 33.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 23.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1088,  Location: 07-LA-005-29.39-BRB (Lat: 34.179633,  Lng: -118.315344),  Route carried "on" structure: City street L301,  Year Built: 1959,  Status: Open,  Structure Length: 10.58m (34.71ft),  Average Daily Traffic: 33,212 (year 2011),  Truck Traffic: 6%,  Average Future Daily Traffic: 43,640 (year 2037),  Design Load: HS 20,  Features Intersected: ROUTE 5 & FRONTAGE RD,  Facility Carried by Structure: MAGNOLIA BOULEVARD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 13,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 27.1m (88.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 87.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1111,  Location: 07-LA-005-31.86-BRB (Lat: 34.206444,  Lng: -118.342714),  Route carried "on" structure: Interstate 5,  Year Built: 1960,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 2.71m (8.89ft),  Average Daily Traffic: 187,358 (year 2011),  Truck Traffic: 9%,  Average Future Daily Traffic: 245,307 (year 2042),  Design Load: HS 20,  Features Intersected: COHASSET STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 31.860,  Lanes on structure: 12,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 53.3m (174.9ft),  Skew: 33 degrees,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 53.2m (174.5ft),  Out-to-Out Width: 54.9m (180.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 67.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 127,  Location: 07-LA-001-12.01-LA (Lat: 33.791103,  Lng: -118.287408),  Route carried "on" structure: State highway 1,  Year Built: 1934,  Year Reconstructed: 1975,  Status: Open,  Structure Length: 3.08m (10.10ft),  Average Daily Traffic: 50,000 (year 2017),  Truck Traffic: 5%,  Average Future Daily Traffic: 60,253 (year 2038),  Design Load: HS 20,  Features Intersected: BIXBY SLOUGH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.010,  Lanes on structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 24.7m (81.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 4.3m (14.1ft),  Curb or Sidewalk Widths: Left: 2.6m (8.5ft),  Right: 2.6m (8.5ft),  Curb-To-Curb Width: 24.7m (81.0ft),  Out-to-Out Width: 30.0m (98.4ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 53 1277,  Location: 07-LA-134-1.82-BRB (Lat: 34.154428,  Lng: -118.345328),  Route carried "on" structure: City street ,  Year Built: 1962,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 8.38m (27.49ft),  Average Daily Traffic: 18,900 (year 2012),  Truck Traffic: 1%,  Average Future Daily Traffic: 28,609 (year 2039),  Design Load: HS 20,  Features Intersected: STATE ROUTE 134 & ONRAMP,  Facility Carried by Structure: PASS AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 11,  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 1,  Length of Maximum Span: 25.8m (84.6ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 22.6m (74.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1278,  Location: 07-LA-134-2.03-BRB (Lat: 34.154050,  Lng: -118.341025),  Route carried "on" structure: City street ,  Year Built: 1962,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 11.14m (36.55ft),  Average Daily Traffic: 40,200 (year 2015),  Truck Traffic: 1%,  Average Future Daily Traffic: 48,742 (year 2039),  Design Load: HS 20,  Features Intersected: STATE ROUTE 134 & ONRAMP,  Facility Carried by Structure: ALAMEDA AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 10,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.3m (79.7ft),  Skew: 5 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 44.2m (145.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 24.3m (79.7ft),  Out-to-Out Width: 28.7m (94.2ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 49.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1279,  Location: 07-LA-134-2.11-BRB (Lat: 34.153867,  Lng: -118.340356),  Route carried "on" structure: City street ,  Year Built: 1962,  Year Reconstructed: 2011,  Status: Open,  Structure Length: 8.11m (26.61ft),  Average Daily Traffic: 24,500 (year 2012),  Truck Traffic: 1%,  Average Future Daily Traffic: 37,086 (year 2040),  Design Load: HS 20,  Features Intersected: STATE ROUTE 134 & RAMPS,  Facility Carried by Structure: HOLLYWOOD WAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 11,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.4m (86.6ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 24.4m (80.1ft),  Out-to-Out Width: 28.7m (94.2ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1281,  Location: 07-LA-134-2.39-BRB (Lat: 34.152869,  Lng: -118.335306),  Route carried "on" structure: City street ,  Year Built: 1962,  Status: Open,  Structure Length: 4.53m (14.86ft),  Average Daily Traffic: 3,500 (year 2012),  Truck Traffic: 2%,  Average Future Daily Traffic: 5,299 (year 2039),  Design Load: HS 20,  Features Intersected: STATE ROUTE 134,  Facility Carried by Structure: CALIFORNIA STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 10,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 21.4m (70.2ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 16.5m (54.1ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 46.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1282,  Location: 07-LA-134-2.67-BRB (Lat: 34.152661,  Lng: -118.330447),  Route carried "on" structure: State highway 134,  Year Built: 1962,  Year Reconstructed: 2014,  Status: Open,  Structure Length: 3.63m (11.91ft),  Average Daily Traffic: 219,000 (year 2015),  Truck Traffic: 4%,  Average Future Daily Traffic: 283,846 (year 2039),  Design Load: HS 20,  Features Intersected: BOB HOPE DRIVE
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 2.670,  Lanes on structure: 10,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 45.1m (148.0ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.0m,  Curb-To-Curb Width: 45.1m (148.0ft),  Out-to-Out Width: 46.7m (153.2ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 67.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1283,  Location: 07-LA-134-2.90-BRB (Lat: 34.153386,  Lng: -118.326761),  Route carried "on" structure: State highway 134,  Year Built: 1962,  Status: Open,  Structure Length: 7.64m (25.07ft),  Average Daily Traffic: 213,000 (year 2017),  Truck Traffic: 4%,  Average Future Daily Traffic: 283,846 (year 2039),  Design Load: HS 20,  Features Intersected: RIVERSIDE DR & ON-RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.900,  Lanes on structure: 10,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 40.2m (131.9ft),  Skew: 39 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 38.4m (126.0ft),  Curb-To-Curb Width: 40.2m (131.9ft),  Out-to-Out Width: 41.7m (136.8ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 71.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53 1368S,  Location: 07-LA-005-31.35-BRB (Lat: 34.200697,  Lng: -118.338417),  Route carried "on" structure: Ramp Interstate 5,  Year Built: 1960,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 9,996 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 12,439 (year 2036),  Features Intersected: BURBANK WESTERN CHANNEL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 31.350,  Lanes on structure: 3,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 41.5m (136.2ft),  Skew: 33 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 41.5m (136.2ft),  Out-to-Out Width: 41.5m (136.2ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2018
Find on map >>   Show street view

Structure Number: 53 1673M,  Location: 07-LA-005-30.00-BRB (Lat: 34.187564,  Lng: -118.321489),  Route carried "on" structure: Interstate 5,  Year Built: 1960,  Status: Open,  Structure Length: 4.51m (14.80ft),  Average Daily Traffic: 239,016 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 239,240 (year 2037),  Features Intersected: BURBANK WEST CHANNEL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.000,  Lanes on structure: 8,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 44.7m (146.7ft),  Skew: 37 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 42.7m (140.1ft),  Curb-To-Curb Width: 44.7m (146.7ft),  Out-to-Out Width: 45.1m (148.0ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: 53 3072,  Location: 07-LA-134-2.82-BRB (Lat: 34.153236,  Lng: -118.327619),  Route carried "on" structure: State highway 134,  Year Built: 1959,  Status: Open,  Structure Length: 1.14m (3.74ft),  Average Daily Traffic: 189,000 (year 2011),  Truck Traffic: 4%,  Average Future Daily Traffic: 283,846 (year 2041),  Features Intersected: BUENA VISTA PARK CHANNEL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.820,  Lanes on structure: 8,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 38.4m (126.0ft),  Skew: 33 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.9m (12.8ft),  Curb-To-Curb Width: 38.4m (126.0ft),  Out-to-Out Width: 52.7m (172.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: 53 3078,  Location: 07-LA-005-30.08-BRB (Lat: 34.188092,  Lng: -118.322044),  Route carried "on" structure: Interstate 5,  Year Built: 2019,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 23,900 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 24,978 (year 2044),  Design Load: HS 20,  Features Intersected: BURBANK WESTERN CHANNEL
Minimum Vertical Clearance: 99.00m (324.80ft),  Kilometerpoint: 30.080,  Lanes on structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 53C0174,  Location: 0.3MI S/O I-5 FWY (Lat: 34.167433,  Lng: -118.307086),  Route carried "on" structure: City street L587,  Year Built: 1949,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 36,252 (year 2012),  Truck Traffic: 4%,  Average Future Daily Traffic: 43,502 (year 2041),  Design Load: HS 20,  Features Intersected: BURBANK WESTERN CHAN,  Facility Carried by Structure: ALAMEDA AVE
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 22.9m (75.1ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.5m (41.0ft),  Curb or Sidewalk Widths: Left: 2.7m (8.9ft),  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 22.9m (75.1ft),  Out-to-Out Width: 23.0m (75.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 53C0190L,  Location: 0.1MI E/O I-710 FWY (Lat: 33.903681,  Lng: -118.183264),  Route carried "on" structure: City street L079,  Year Built: 1951,  Year Reconstructed: 1972,  Status: Open,  Structure Length: 18.51m (60.73ft),  Average Daily Traffic: 13,699 (year 2012),  Truck Traffic: 5%,  Average Future Daily Traffic: 15,754 (year 2040),  Design Load: HS 20,  Features Intersected: LOS ANGELES RIV,  Facility Carried by Structure: ROSECRANS AVE W
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 25.0m (82.0ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 45.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53C0198,  Location: 300FT W/O I-5 FWY (Lat: 34.184528,  Lng: -118.320597),  Route carried "on" structure: City street L570,  Year Built: 1958,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 12.45m (40.85ft),  Average Daily Traffic: 50,138 (year 2012),  Truck Traffic: 20%,  Average Future Daily Traffic: 60,166 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: LAKE ST / SPTCO,  Facility Carried by Structure: BURBANK BLVD
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 1,  Length of Maximum Span: 124.5m (408.5ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 2.3m (7.5ft),  Curb-To-Curb Width: 30.1m (98.8ft),  Out-to-Out Width: 34.5m (113.2ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 44.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C02,  Location: 0.1MI W/O I-5 FWY (Lat: 34.179622,  Lng: -118.315322),  Route carried "on" structure: City street ,  Year Built: 1949,  Year Reconstructed: 1959,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 408 (year 2012),  Truck Traffic: 2%,  Average Future Daily Traffic: 408 (year 2041),  Design Load: HS 20,  Features Intersected: BURBANK WESTERN CHAN,  Facility Carried by Structure: MGNOLIA BLVD F RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 2.8m (9.2ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.0m (49.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 53C0741,  Location: 0.3MI N/O US-101 FWY (Lat: 34.158333,  Lng: -118.266783),  Route carried "on" structure: City street Q407,  Year Built: 1936,  Status: Open,  Structure Length: 3.02m (9.91ft),  Average Daily Traffic: 2,550 (year 2015),  Truck Traffic: 1%,  Average Future Daily Traffic: 2,805 (year 2041),  Design Load: H 20,  Features Intersected: VERDUGO WASH,  Facility Carried by Structure: KENILWORTH AVE
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.0m (95.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 55.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Critical Feature Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 53C0749,  Location: 0.3MI E/O I-5 FWY (Lat: 34.172453,  Lng: -118.301681),  Route carried "on" structure: City street ,  Year Built: 1963,  Status: Open,  Structure Length: 2.36m (7.74ft),  Average Daily Traffic: 500 (year 2012),  Truck Traffic: 2%,  Average Future Daily Traffic: 500 (year 2041),  Design Load: HS 20,  Features Intersected: ALAMEDA AVE,  Facility Carried by Structure: E ACCESS RD
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 11.6m (38.1ft),  Curb or Sidewalk Widths: Left: 1.3m (4.3ft),  Right: 0.8m (2.6ft),  Curb-To-Curb Width: 7.5m (24.6ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 72.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53C0751,  Location: 0.3MI E/O I-5 FWY (Lat: 34.172156,  Lng: -118.302003),  Route carried "on" structure: City street ,  Year Built: 1963,  Status: Open,  Structure Length: 2.35m (7.71ft),  Average Daily Traffic: 500 (year 2012),  Truck Traffic: 2%,  Average Future Daily Traffic: 500 (year 2041),  Design Load: HS 20,  Features Intersected: ALAMEDA AVE,  Facility Carried by Structure: W ACCESS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 11.6m (38.1ft),  Curb or Sidewalk Widths: Left: 0.8m (2.6ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 7.5m (24.6ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 72.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53C0752,  Location: 0.3MI E/O ALAMEDA AVE (Lat: 34.164414,  Lng: -118.304497),  Route carried "on" structure: City street L545,  Year Built: 1940,  Status: Open,  Structure Length: 2.59m (8.50ft),  Average Daily Traffic: 22,154 (year 2012),  Truck Traffic: 3%,  Average Future Daily Traffic: 26,585 (year 2041),  Design Load: HS 20,  Features Intersected: BURBANK WESTERN CHAN,  Facility Carried by Structure: VICTORY BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 20.8m (68.2ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.0m (82.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 20.8m (68.2ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 55.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 53C0754,  Location: 0.3MI W/O ALAMEDA AVE (Lat: 34.171828,  Lng: -118.309486),  Route carried "on" structure: City street Q234,  Year Built: 1949,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 6,180 (year 2012),  Truck Traffic: 4%,  Average Future Daily Traffic: 7,107 (year 2041),  Design Load: HS 20,  Features Intersected: BURBANK WESTERN CHAN,  Facility Carried by Structure: LKE ST / PROVI AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.3m (43.6ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 53C0941,  Location: 0.5MI N/O VICTORY BLVD (Lat: 34.191639,  Lng: -118.349044),  Route carried "on" structure: City street L546,  Year Built: 1970,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 6,489 (year 2012),  Truck Traffic: 1%,  Average Future Daily Traffic: 7,462 (year 2041),  Design Load: HS 20,  Features Intersected: HOLLYWOOD WAY,  Facility Carried by Structure: VANOWEN ST
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 21.4m (70.2ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 18.8m (61.7ft),  Out-to-Out Width: 22.5m (73.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 66.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53C0943,  Location: 0.5MI N/O VICTORY BLVD (Lat: 34.192211,  Lng: -118.349067),  Route carried "on" structure: City street L300,  Year Built: 1970,  Status: Open,  Structure Length: 2.68m (8.79ft),  Average Daily Traffic: 13,081 (year 2012),  Truck Traffic: 2%,  Average Future Daily Traffic: 15,043 (year 2041),  Design Load: HS 20,  Features Intersected: HOLLYWOOD WAY,  Facility Carried by Structure: EMPIRE AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 2.5m (8.2ft),  Right: 1.9m (6.2ft),  Curb-To-Curb Width: 18.9m (62.0ft),  Out-to-Out Width: 23.9m (78.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 63.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 53C0954,  Location: 200FT N/O I-5 FWY (Lat: 34.199469,  Lng: -118.337753),  Route carried "on" structure: City street Q228,  Year Built: 1958,  Status: Open,  Structure Length: 2.02m (6.63ft),  Average Daily Traffic: 27,984 (year 2012),  Truck Traffic: 1%,  Average Future Daily Traffic: 33,581 (year 2041),  Design Load: HS 20,  Features Intersected: BURBANK WESTERN CHAN,  Facility Carried by Structure: BUENA VISTA-WINONA
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 6 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 18.2m (59.7ft),  Out-to-Out Width: 32.9m (107.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 55.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 53C0956,  Location: 50FT E/O I-5 FWY (Lat: 34.206458,  Lng: -118.342539),  Route carried "on" structure: City street ,  Year Built: 1958,  Status: Open,  Structure Length: 1.23m (4.04ft),  Average Daily Traffic: 2,754 (year 2012),  Truck Traffic: 3%,  Average Future Daily Traffic: 3,029 (year 2041),  Design Load: HS 20,  Features Intersected: BURBANK WESTERN CHAN,  Facility Carried by Structure: COHASSET ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.1m (49.5ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.6m (34.8ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.9m (6.2ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 18.6m (61.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 85.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 53C1833,  Location: 0.5MI S/O I-5 (Lat: 34.205758,  Lng: -118.348850),  Route carried "on" structure: City street L900,  Year Built: 1984,  Status: Open,  Structure Length: 3.84m (12.60ft),  Average Daily Traffic: 5,459 (year 2012),  Truck Traffic: 4%,  Average Future Daily Traffic: 6,278 (year 2041),  Design Load: HS 20,  Features Intersected: HOLLYWOOD WAY,  Facility Carried by Structure: SAN FERNANDO BLV N
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Skew: 23 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 18.9m (62.0ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 14.9m (48.9ft),  Out-to-Out Width: 23.0m (75.5ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 70.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.78m (15.68ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C1834,  Location: 0.5MI S/O I-5 (Lat: 34.205208,  Lng: -118.348886),  Route carried "on" structure: City street ,  Year Built: 1984,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 10,918 (year 2012),  Truck Traffic: 4%,  Average Future Daily Traffic: 12,556 (year 2041),  Design Load: HS 20,  Features Intersected: HOLLYWOOD WAY,  Facility Carried by Structure: SAN FERNANDO BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 23 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 19.5m (64.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 21.2m (69.6ft),  Out-to-Out Width: 26.1m (85.6ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 85.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C1902,  Location: AT I-5 FWY (Lat: 34.177178,  Lng: -118.312564),  Route carried "on" structure: City street L426,  Year Built: 1959,  Status: Open,  Structure Length: 17.30m (56.76ft),  Average Daily Traffic: 30,104 (year 2012),  Truck Traffic: 1%,  Average Future Daily Traffic: 36,125 (year 2041),  Features Intersected: FRONT ST, SPTCO, FLOWER,  Facility Carried by Structure: OLIVE AVE
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Number Of Approach Spans: 3,  Length of Maximum Span: 32.4m (106.3ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 1.9m (6.2ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 33.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 20.1 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C1903,  Location: AT I-5 FWY (Lat: 34.180314,  Lng: -118.314603),  Route carried "on" structure: City street L301,  Year Built: 1959,  Status: Open,  Structure Length: 14.50m (47.57ft),  Average Daily Traffic: 29,786 (year 2012),  Truck Traffic: 4%,  Average Future Daily Traffic: 35,743 (year 2041),  Design Load: H 20,  Features Intersected: FRONTAGE RD / SPTCO,  Facility Carried by Structure: MAGNOLIA BL
Minimum Vertical Clearance: 30.47m (99.97ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 4,  Length of Maximum Span: 32.3m (106.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.7m (51.5ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 81.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 53C2231,  Location: 290FT E/O MEADOW PASS RD (Lat: 34.029686,  Lng: -117.861375),  Route carried "on" structure: City street ,  Year Built: 1995,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 202 (year 2012),  Truck Traffic: 2%,  Average Future Daily Traffic: 202 (year 2041),  Features Intersected: LEMON CRK,  Facility Carried by Structure: PIERRE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 26.0m (85.3ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Channel: Excellent,  Culverts: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: Febuary 2021
Discuss Burbank, California (CA) on our hugely popular California forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.