Restaurant: Subway-South Lakes
Address: 11160d South Lakes Dr, Reston, VA 20191
Type: Fast Food Restaurant
Phone: 703 815-5570
Total inspections: 4
Last inspection: 05/18/2015
Handwashing Sink / Accessible at All Times (corrected on site) Observation: The handwashing facility located at the 3-vat sink area is blocked by a container or lids, preventing access by employees for easy handwashing.
Correction: A hand washing sink shall be maintained so that it is accessible at all times for employee use.
05/18/2015
Risk Factor
Note: Reviewed temperature log. Recommendations: 1) Adjust temperature for the 2DR prep refrigerator to 36F during summer time. 2) Please have a thermometer inside each refrigerator and cold well to monitor ambient air temperature. 3) Do not overfill containers on prep top--example, pepperjack cheese was filled above the fill line.
Ambient Air & Water Temp Meas Devices, F Scale, Accurate within 3°F (repeated violation) Observation: The ambient air temperature measuring device, in-built thermometer on door, located in the walk-in refrigerator unit is not accurate in 7°F. It was 35F inside and the thermometer showed 42F.
Correction: Ambient air and water temperature measuring devices that are scaled only in Fahrenheit shall be accurate to +/-3°F in the intended range of use.
Temp Meas Devices for Cold & Hot Hold Equipment, Present Observation: There was no temperature measuring device located in the following cold or hot holding equipment: 2DR flat top refrigerator front and cold wells at preparation line
Correction: Cold or hot holding equipment used for the storage of potentially hazardous foods (time/temperature control for safety food) shall be designed to include and shall be equipped with at least one integral or permanently affixed temperature measuring device that is located to allow easy viewing of the device's temperature display.
04/21/2015
Routine
The purpose of this visit was to conduct a routine risk evaluation. Quaternary ammonium sanitizer in 3 vat sink: 250 ppm.
Ambient Air & Water Temp Meas Devices, F Scale, Accurate within 3°F Observation: The ambient (air/water) temperature measuring device located in the following unit is not accurate in °F. Thermometer in 2 dr UC refrigerator.
Correction: Ambient air and water temperature measuring devices that are scaled only in Fahrenheit shall be accurate to +/-3°F in the intended range of use.
Restaurant representatives - add corrected or new information about Subway-South Lakes, 11160d South Lakes Dr, Reston, VA 20191 »