No violation noted during this evaluation. | 01/19/2016 | Routine | |
- Sanitizing Solutions, Testing Devices
Observation: There is no properly working test kit provided in the facility for monitoring the concentration of the chemical sanitizing solutions.
Correction: Obtain a test kit so that employees can accurately monitor the concentration of the sanitizing solutions and maintain them at a safe and effective level.
- Equipment - Good Repair and Proper Adjustment
Observation: Gasket on hot holding unit is not keeping door closed
Correction: Repair the hot holding unit to restore a state of condition that allows for proper operation, accuracy, functioning, maintenance, and cleanability per Part IV, Article 1 and 2 of this chapter. If unable to repair the @EQUIPMENT@, replace it with one that meets the specifications of Part IV, Article 1 and 2 of this chapter.
- Refuse - Covering Receptacles
Observation: Observed filled refuse containers stored in the establishment containing food residue wastes without lids.
Correction: Cover all waste containers when not in continuous use.
|
09/16/2015 | Routine | |
No violation noted during this evaluation. | 02/04/2015 | Follow-up | |
Dishwasher has not been repaired properly
- Warewash Machines, Temperature Measuring Devices (repeated violation)
Observation: The temperature measuring device for thewash and sanitize tank of the warewashing machine is not operating correctly
Correction: Provide a functioning temperature measuring device at the (wash/rinse/sanitizing) compartment so employees can routinely monitor the water temperature.
- Warewashing - Mechanical Warewashing Equipment, Wash Solution Temperature (repeated violation)
Observation: The wash and sanitize temperature of the high temperature sanitizing ware wash machine is not meeting the manufacturer's specifications. .
Correction: Discontinue the use of the ware wash machine until it is working properly. Initiate manual wash, rinse, and sanitize method to properly clean equipment and utensils. To minimize workload you can move to all single service utensils.
|
01/22/2015 | Follow-up | |
- Warewash Machines, Temperature Measuring Devices
Observation: The temperature measuring device for thewash and sanitize tank of the warewashing machine is not operating correctly
Correction: Provide a functioning temperature measuring device at the (wash/rinse/sanitizing) compartment so employees can routinely monitor the water temperature.
- Warewashing - Mechanical Warewashing Equipment, Wash Solution Temperature
Observation: The wash and sanitize temperature of the high temperature sanitizing ware wash machine is not meeting the manufacturer's specifications. .
Correction: Discontinue the use of the ware wash machine until it is working properly. Initiate manual wash, rinse, and sanitize method to properly clean equipment and utensils. To minimize workload you can move to all single service utensils.
|
01/20/2015 | Routine | |
No violation noted during this evaluation. | 09/11/2014 | Routine | |
No violation noted during this evaluation. | 03/11/2014 | Routine | |
- Plumbing System Maintained in Good Repair (corrected on site)
Observation: Very little water pressure at the handsink
Correction: Repair and maintain all plumbing components ans fixtures. PLUMBER CAME TO THE FACILITY DURING INSPECTION, AND IS IN THE PROCESS OF REPAIRING THE SINK
|
09/16/2013 | Routine | |
- Good Repair and Calibration of Thermometers (repeated violation)
Observation: Observed food thermometer is not calibrated to ensure accuracy
Correction: Calibrate food thermometer according to manufacturer's specification as necessary to ensure accuracy
|