Facility underwent change of ownership on 3/1/15. Person in charge has been made aware of need to submit application and fee for health license for Regency Care of Arlington.
- Equipment/Good Repair and Proper Adjustment
Observation: The handle to the plate warming cabinet in 2nd floor kitchenette was in disrepair.
The True 2 door prep unit in 2nd floor kitchenette was in disrepair.
The microwave for kitchen use was in disrepair.
The interior bottom cabinetry in 2nd floor kitchenette was in disrepair.
Correction: Equipment shall be maintained in a state of repair and condition that meets the requirements specified under Parts 4-1 [Materials for Construction and Repair] and 4-2 [Design and Construction]. Proper maintenance of equipment to manufacturer specifications helps ensure that it will continue to operate as designed. Failure to properly maintain equipment could lead to violations of the associated requirements of the Code that place the health of the consumer at risk. For example, refrigeration units in disrepair may no longer be capable of properly cooling or holding potentially hazardous (time/temperature control for safety) foods at safe temperatures.
- Floors, Walls, and Ceilings/Cleanability
Observation: The ceiling tiles in 2nd floor kitchenette area are not designed, constructed, and installed so that it is smooth and easily cleanable.
Correction: Floors, floor coverings, walls, wall coverings, and ceilings shall be designed, constructed and installed so that they are smooth and easily cleanable except for anti-slip floor coverings or applications that may be used for safety reasons and except as specified under section 6-201.14. Floors that are of smooth, durable construction and that are nonabsorbent are more easily cleaned. Requirements and restrictions regarding floor coverings, utility lines, and floor/wall junctures are intended to ensure that regular and effective cleaning is possible and that insect and rodent harborage is minimized.
- Light Bulbs, Protective Shielding
Observation: Some ceiling lights in kitchen were missing end caps.
Correction: Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food
- Handwashing Signage
Observation: A sign or poster that notifies food employees to wash their hands is not provided at all handwashing lavatories used by food employees and/or is not clearly visible to food employees. 2nd floor kitchenette hand sink was missing hand wash signage.
Correction: A sign or poster that notifies food employees to wash their hands shall be provided at all handwashing sinks used by food employees and shall be clearly visible to food employees. A sign or poster is required to remind food employees to wash their hands.
|
03/23/2015 | Routine | |
Restaurant representatives - add corrected or new information about Regency Care Of Arlington Llc, 1785 S Hayes St, Arlington, VA 22202 »