Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Florence, South Carolina (SC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 97Number of bridges
  • 1,316ft / 401mTotal length
  • $9,636,000Total costs
  • 1,337,810Total average daily traffic
  • 133,957Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Florence
  • No street view available for this location

New bridges in Florence, SC - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 21920-1929
  • 41930-1939
  • 51940-1949
  • 11950-1959
  • 361960-1969
  • 161970-1979
  • 81980-1989
  • 61990-1999
  • 112000-2009
  • 52010-2019
  • 22020-2022
Reconstructed bridges in Florence, SC - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 21960-1969
  • 11970-1979
  • 21980-1989
  • 51990-1999
Average Bridge Daily Traffic in Florence, SC
Average Bridge Truck Traffic in Florence, SC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 7.5%Excellent
  • 13.4%Very good
  • 28.4%Good
  • 44.8%Satisfactory
  • 6.0%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 7.5%Excellent
  • 16.4%Very good
  • 28.4%Good
  • 43.3%Satisfactory
  • 4.5%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 6.0%Excellent
  • 20.9%Very good
  • 29.9%Good
  • 37.3%Satisfactory
  • 4.5%Fair
  • 1.5%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 49.0%Very good
  • 29.4%Good
  • 13.7%Satisfactory
  • 5.9%Fair
  • 2.0%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 10.0%Very good
  • 80.0%Good
  • 10.0%Satisfactory
Find on map >>   Show street view

Structure Number: 104,  Location: CITY OF FLORENCE (Lat: 34.173028,  Lng: -79.762411),  Route carried "on" structure: Ramp State highway 12,  Year Built: 2019,  Status: Open,  Structure Length: 4.27m (14.01ft),  Average Daily Traffic: 4,500 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 2,700 (year 2040),  Design Load: HL 93,  Features Intersected: JEFFERIES CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.399,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.27m (14.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 10401,  Location: 5 MI SE OF DARLINGTON (Lat: 34.237781,  Lng: -79.837144),  Route carried "on" structure: State highway 49,  Year Built: 2020,  Status: Open,  Structure Length: 3.05m (10.01ft),  Average Daily Traffic: 6,900 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 4,140 (year 2040),  Design Load: HS 20,  Features Intersected: HIGH HILL CREEK
Minimum Vertical Clearance: 9.14m (29.99ft),  Kilometerpoint: 4.167,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Very good,  Operating Rating: 50.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 3.90m (12.80ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Bridge Improvement Cost: $394,000,  Roadway Improvement Cost: $99,000,  Total Project Cost: $591,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 1044,  Location: 7.5 MI SE OF FLORENCE (Lat: 34.102731,  Lng: -79.702067),  Route carried "on" structure: State highway 51,  Year Built: 2019,  Status: Open,  Structure Length: 3.66m (12.01ft),  Average Daily Traffic: 7,600 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 5,852 (year 2040),  Design Load: HL 93,  Features Intersected: WILLOW CREEK
Minimum Vertical Clearance: 9.14m (29.99ft),  Kilometerpoint: 49.487,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 25.3m (83.0ft),  Out-to-Out Width: 26.2m (86.0ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Very good,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 3.66m (12.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 4767,  Location: 7MI SW OF FLORENCE (Lat: 34.155614,  Lng: -79.872564),  Route carried "under" structure: US 76,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 4,600 (year 2020),  Truck Traffic: 12%,  Features Intersected: US 76,  Facility Carried by Structure: I-95 NB
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 18.717,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 4769,  Location: 3 MI NW OF FLORENCE (Lat: 34.229703,  Lng: -79.799528),  Route carried "under" structure: US 52,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 18,400 (year 2020),  Truck Traffic: 10%,  Features Intersected: US 52&S-21-498&RR CSXT,  Facility Carried by Structure: I-95
Minimum Vertical Clearance: 6.40m (21.00ft),  Kilometerpoint: 46.816,  Lanes on structure: 6,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.1m (56.1ft)

Find on map >>   Show street view

Structure Number: 4776,  Location: 7MI SW OF FLORENCE (Lat: 34.155494,  Lng: -79.872956),  Route carried "under" structure: US 76,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 4,600 (year 2020),  Truck Traffic: 12%,  Features Intersected: US 76,  Facility Carried by Structure: I-95 SB
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 18.717,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Find on map >>   Show street view

Structure Number: 4778,  Location: 4.0 MI NW OF FLORENCE (Lat: 34.204842,  Lng: -79.833358),  Route carried "under" structure: State highway 13,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 8,200 (year 2020),  Truck Traffic: 2%,  Features Intersected: S-21-13,  Facility Carried by Structure: I-95 SB
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 3.460,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 4786,  Location: 3 MI NW FLORENCE (Lat: 34.238956,  Lng: -79.788211),  Route carried "under" structure: Interstate 95,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 48,500 (year 2020),  Truck Traffic: 19%,  Features Intersected: I-95,  Facility Carried by Structure: S-21-63
Minimum Vertical Clearance: 5.82m (19.09ft),  Kilometerpoint: 265.558,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.8m (78.1ft)

Find on map >>   Show street view

Structure Number: 4787,  Location: 4MI SW FLORENCE (Lat: 34.146633,  Lng: -79.876161),  Route carried "under" structure: Interstate 95,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 31,000 (year 2020),  Truck Traffic: 20%,  Features Intersected: I-95,  Facility Carried by Structure: S-21-107
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 252.039,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 4789,  Location: OAKDALE SUBD FLORENCE (Lat: 34.178064,  Lng: -79.863894),  Route carried "under" structure: Interstate 95,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 30,200 (year 2020),  Truck Traffic: 9%,  Features Intersected: I-95,  Facility Carried by Structure: S-21-577
Minimum Vertical Clearance: 6.38m (20.93ft),  Kilometerpoint: 255.725,  Lanes on structure: 5,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.3m (96.1ft)

Find on map >>   Show street view

Structure Number: 5013,  Location: 5MI N FLORENCE (Lat: 34.250111,  Lng: -79.762697),  Route carried "under" structure: Interstate 95,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 48,500 (year 2020),  Truck Traffic: 19%,  Features Intersected: I-95,  Facility Carried by Structure: S-16-179
Minimum Vertical Clearance: 5.82m (19.09ft),  Kilometerpoint: 268.262,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.8m (87.9ft)

Find on map >>   Show street view

Structure Number: 5038,  Location: 4.7 MI W OF FLORENCE (Lat: 34.193347,  Lng: -79.844283),  Route carried "under" structure: Interstate 95,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 15,100 (year 2020),  Truck Traffic: 9%,  Features Intersected: I-95,  Facility Carried by Structure: I-20 EB
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 258.251,  Lanes on structure: 3,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.2m (86.0ft)

Find on map >>   Show street view

Structure Number: 5039,  Location: 4.7 MI W OF FLORENCE (Lat: 34.193550,  Lng: -79.843922),  Route carried "under" structure: Interstate 95,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 15,100 (year 2020),  Truck Traffic: 9%,  Features Intersected: I-95,  Facility Carried by Structure: I-20 WB
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 258.251,  Lanes on structure: 3,  Lanes under structure: 6,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.2m (86.0ft)

Find on map >>   Show street view

Structure Number: 5044,  Location: 4 MI NW OF FLORENCE (Lat: 34.204725,  Lng: -79.833033),  Route carried "under" structure: State highway 13,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 8,200 (year 2020),  Truck Traffic: 2%,  Features Intersected: S-21-13,  Facility Carried by Structure: I-95 NB
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 3.460,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 505,  Location: 4.5 MI W OF FLORENCE (Lat: 34.196056,  Lng: -79.840611),  Route carried "under" structure: Ramp Interstate 20,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 8,760 (year 2004),  Truck Traffic: 18%,  Features Intersected: I-20 EB,  Facility Carried by Structure: I-95 SB
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 227.674,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.0m (95.1ft)

Find on map >>   Show street view

Structure Number: 5056,  Location: 2MI W FLORENCE (Lat: 34.196494,  Lng: -79.849492),  Route carried "under" structure: Interstate 20,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 28,000 (year 2020),  Truck Traffic: 11%,  Features Intersected: I-20,  Facility Carried by Structure: S-21-112
Minimum Vertical Clearance: 5.84m (19.16ft),  Kilometerpoint: 227.095,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.0m (82.0ft)

Find on map >>   Show street view

Structure Number: 5057,  Location: 2MI W FLORENCE (Lat: 34.190561,  Lng: -79.848250),  Route carried "under" structure: Interstate 95,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 30,200 (year 2020),  Truck Traffic: 9%,  Features Intersected: I-95,  Facility Carried by Structure: S-21-112
Minimum Vertical Clearance: 5.46m (17.91ft),  Kilometerpoint: 257.736,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.5m (86.9ft)

Find on map >>   Show street view

Structure Number: 5058,  Location: 3MI NW FLORENCE (Lat: 34.217208,  Lng: -79.816942),  Route carried "under" structure: Interstate 95,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 51,700 (year 2020),  Truck Traffic: 9%,  Features Intersected: I-95,  Facility Carried by Structure: S-21-193
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 261.953,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.4m (57.1ft)

Find on map >>   Show street view

Structure Number: 6261,  Location: 7MI S OF DARLINGTON (Lat: 34.204017,  Lng: -79.913347),  Route carried "under" structure: State highway 340,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 975 (year 2020),  Truck Traffic: 5%,  Features Intersected: SC 340,  Facility Carried by Structure: I-20 EB
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 6.341,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.4m (126.0ft)

Find on map >>   Show street view

Structure Number: 6264,  Location: 9MI W OF FLORENCE (Lat: 34.204211,  Lng: -79.913094),  Route carried "under" structure: State highway 340,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 975 (year 2020),  Truck Traffic: 5%,  Features Intersected: SC 340,  Facility Carried by Structure: I-20 WB
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 6.341,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.4m (126.0ft)

Find on map >>   Show street view

Structure Number: 6291,  Location: 4.8 MI W FLORENCE (Lat: 34.195386,  Lng: -79.846131),  Route carried "under" structure: Interstate 20,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 28,000 (year 2020),  Truck Traffic: 11%,  Features Intersected: RAMP ON I-20 WB
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 227.400,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.0m (105.0ft)

Find on map >>   Show street view

Structure Number: 6493,  Location: 1MI W I-95 & I-20 INT (Lat: 34.204311,  Lng: -79.879228),  Route carried "under" structure: Interstate 20,  Year Built: 1974,  Structure Length: 0. m,  Average Daily Traffic: 28,000 (year 2020),  Truck Traffic: 11%,  Features Intersected: I-20,  Facility Carried by Structure: S-21-1355
Minimum Vertical Clearance: 5.41m (17.75ft),  Kilometerpoint: 224.182,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.6m (97.1ft)

Find on map >>   Show street view

Structure Number: 7357,  Location: CHURCH ST FLORENCE (Lat: 34.197261,  Lng: -79.761997),  Route carried "under" structure: State highway 1545,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 125 (year 2020),  Truck Traffic: 5%,  Features Intersected: S-1545,  Facility Carried by Structure: S-21-12
Minimum Vertical Clearance: 4.27m (14.01ft),  Kilometerpoint: 0.446,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Concrete,  Design/Construction: Slab,  Length of Maximum Span: 9.1m (29.9ft)

Discuss Florence, South Carolina (SC) on our hugely popular South Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.