Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Reed City, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 53Number of bridges
  • 338ft / 103mTotal length
  • 246,521Total average daily traffic
  • 29,918Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Reed City
  • No street view available for this location

New bridges in Reed City, MI - historical statistics
  • New bridges - historical statistics
  • 11940-1949
  • 31950-1959
  • 11970-1979
  • 411980-1989
  • 41990-1999
  • 12000-2009
  • 22010-2019
Reconstructed bridges in Reed City, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11970-1979
  • 11980-1989
Average Bridge Daily Traffic in Reed City, MI
Average Bridge Truck Traffic in Reed City, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 6.1%Very good
  • 39.4%Good
  • 51.5%Satisfactory
  • 3.0%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 14.7%Very good
  • 44.1%Good
  • 35.3%Satisfactory
  • 5.9%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 5.9%Very good
  • 58.8%Good
  • 29.4%Satisfactory
  • 5.9%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 4.8%Very good
  • 38.1%Good
  • 38.1%Satisfactory
  • 19.0%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 20.0%Very good
  • 80.0%Good
Find on map >>   Show street view

Structure Number: 854,  Location: 7.2 MI E OF I-196 (Lat: 42.178750,  Lng: -86.249975),  Route carried "on" structure: Interstate 94,  Year Built: 1959,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 30,064 (year 2007),  Truck Traffic: 27%,  Average Future Daily Traffic: 42,736 (year 2018),  Design Load: HS 20,  Features Intersected: MILL CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.576,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 136,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 27.2m (89.2ft),  Skew: 11 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 42.0m (137.8ft),  Out-to-Out Width: 62.0m (203.4ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 97.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 858,  Location: 1.4 MI W OF THREE OAKS (Lat: 41.798892,  Lng: -86.636825),  Route carried "on" structure: US 12,  Year Built: 2017,  Status: Open,  Structure Length: 0.68m (2.23ft),  Average Daily Traffic: 5,975 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 6,625 (year 2037),  Design Load: Greater than HL93,  Features Intersected: DEER CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.014,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 135,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.2m (20.3ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 71.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 54.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 6726,  Location: 1.4 MI N OF 22 MI RD (Lat: 43.805856,  Lng: -85.533761),  Route carried "on" structure: US 131,  Year Built: 1984,  Status: Open,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 6,322 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 10,456 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: BUCKHORN CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 38.408,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 180,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 61.2m (200.8ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 97.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022
Find on map >>   Show street view

Structure Number: 6727,  Location: 1.4 MI N OF 22 MI RD (Lat: 43.805353,  Lng: -85.535244),  Route carried "on" structure: US 131,  Year Built: 1984,  Status: Open,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 6,322 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 10,456 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: BUCKHORN CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 38.333,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 180,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 44.6m (146.3ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 97.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022
Find on map >>   Show street view

Structure Number: 854,  Location: 0.26 MI S OF US-10 (Lat: 43.880383,  Lng: -85.509947),  Route carried "on" structure: Alternate US 131,  Year Built: 1954,  Status: Open,  Structure Length: 3.04m (9.97ft),  Average Daily Traffic: 5,735 (year 2007),  Truck Traffic: 2%,  Average Future Daily Traffic: 7,493 (year 2018),  Design Load: HS 20,  Features Intersected: HERSEY RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.302,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 18.4m (60.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 66.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 8551,  Location: 1.5 MI NW OF REED CITY (Lat: 43.890189,  Lng: -85.527631),  Route carried "on" structure: US 131,  Year Built: 1984,  Status: Open,  Structure Length: 3.32m (10.89ft),  Average Daily Traffic: 6,391 (year 2007),  Truck Traffic: 14%,  Average Future Daily Traffic: 9,660 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: JOHNSON CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.462,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.2m (108.9ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 84.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8552,  Location: 1.5 MI NW OF REED CITY (Lat: 43.890150,  Lng: -85.528092),  Route carried "on" structure: US 131,  Year Built: 1984,  Status: Open,  Structure Length: 3.26m (10.70ft),  Average Daily Traffic: 6,391 (year 2007),  Truck Traffic: 14%,  Average Future Daily Traffic: 9,660 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: JOHNSON CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.454,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.6m (57.7ft),  Curb-To-Curb Width: 19.2m (63.0ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 59.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8553,  Location: 1.5 MI NW OF REED CITY (Lat: 43.890094,  Lng: -85.526611),  Route carried "on" structure: Ramp US 131,  Year Built: 1984,  Status: Open,  Structure Length: 2.60m (8.53ft),  Average Daily Traffic: 1,400 (year 1988),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,610 (year 2008),  Design Load: HS 25 or greater,  Features Intersected: JOHNSON CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.348,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 86.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8554,  Location: 1.5 MI NW OF REED CITY (Lat: 43.886497,  Lng: -85.531997),  Route carried "on" structure: Ramp US 131,  Year Built: 1984,  Status: Open,  Structure Length: 2.83m (9.28ft),  Average Daily Traffic: 1,400 (year 1988),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,500 (year 1977),  Design Load: HS 25 or greater,  Features Intersected: JOHNSON CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.389,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.3m (92.8ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 85.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8555,  Location: 1.5 MI NW OF REED CITY (Lat: 43.883992,  Lng: -85.527681),  Route carried "on" structure: US 131,  Year Built: 1984,  Status: Open,  Structure Length: 3.99m (13.09ft),  Average Daily Traffic: 6,322 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 10,456 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: CSX RR (ABN)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.773,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 69.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8556,  Location: 1.5 MI NW OF REED CITY (Lat: 43.884086,  Lng: -85.528119),  Route carried "on" structure: US 131,  Year Built: 1984,  Status: Open,  Structure Length: 3.93m (12.89ft),  Average Daily Traffic: 6,322 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 10,456 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: CSX RR (ABN)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.780,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 64.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8557,  Location: 1.5 MI NW OF REED CITY (Lat: 43.883819,  Lng: -85.527044),  Route carried "on" structure: Ramp US 131,  Year Built: 1984,  Status: Open,  Structure Length: 3.87m (12.70ft),  Average Daily Traffic: 1,400 (year 1988),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,500 (year 1977),  Design Load: HS 25 or greater,  Features Intersected: CSX RR (ABN)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.361,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 67.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8558,  Location: 1.5 MI NW OF REED CITY (Lat: 43.884239,  Lng: -85.529136),  Route carried "on" structure: Ramp US 131,  Year Built: 1984,  Status: Open,  Structure Length: 5.33m (17.49ft),  Average Daily Traffic: 1,500 (year 1988),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,550 (year 1977),  Design Load: HS 25 or greater,  Features Intersected: CSX RR (ABN)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.729,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.6m (61.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 74.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8559,  Location: 4 MILES S OF REED CITY (Lat: 43.815611,  Lng: -85.536089),  Route carried "on" structure: US 131,  Year Built: 1984,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 6,322 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 10,456 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: MECEOLA ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 13.9m (45.6ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 85.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 856,  Location: 4 MILE S OF REED CITY (Lat: 43.815594,  Lng: -85.538000),  Route carried "on" structure: US 131,  Year Built: 1984,  Status: Open,  Structure Length: 2.83m (9.28ft),  Average Daily Traffic: 6,322 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 10,456 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: MECEOLA ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 13.8m (45.3ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 68.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8561,  Location: 2.5 MI SW REED CITY (Lat: 43.844506,  Lng: -85.530803),  Route carried "on" structure: US 131,  Year Built: 1984,  Status: Open,  Structure Length: 3.04m (9.97ft),  Average Daily Traffic: 6,322 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 10,456 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: HERSEY RD (2 MILE RD)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.251,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.4m (99.7ft),  Curb-To-Curb Width: 13.6m (44.6ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 70.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8562,  Location: 2.5 MI SW OF REED CITY (Lat: 43.844500,  Lng: -85.532531),  Route carried "on" structure: US 131,  Year Built: 1984,  Status: Open,  Structure Length: 3.17m (10.40ft),  Average Daily Traffic: 6,322 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 10,456 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: HERSEY RD (2 MILE RD)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.246,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 14.1m (46.3ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 31.7m (104.0ft),  Curb-To-Curb Width: 13.6m (44.6ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 89.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 53.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8563,  Location: 2.0 MI SW OF REED CITY (Lat: 43.858903,  Lng: -85.533889),  Route carried "on" structure: US 131,  Year Built: 1984,  Status: Open,  Structure Length: 3.17m (10.40ft),  Average Daily Traffic: 6,322 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 10,456 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: PECK LAKE RD (3 MILE RD)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.886,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 31.7m (104.0ft),  Curb-To-Curb Width: 13.6m (44.6ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 89.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 53.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8564,  Location: 2.0 MI SW OF REED CITY (Lat: 43.858908,  Lng: -85.535075),  Route carried "on" structure: US 131,  Year Built: 1984,  Status: Open,  Structure Length: 2.98m (9.78ft),  Average Daily Traffic: 6,322 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 10,456 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: PECK LAKE RD (3 MILE RD)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.873,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.8m (97.8ft),  Curb-To-Curb Width: 13.6m (44.6ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 87.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 52.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8565,  Location: 0.5 MI W OF REED CITY (Lat: 43.873122,  Lng: -85.529294),  Route carried "on" structure: US 131,  Year Built: 1984,  Status: Open,  Structure Length: 3.04m (9.97ft),  Average Daily Traffic: 6,322 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 10,456 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: CHIPPEWA RD (4 MILE RD)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.549,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.4m (99.7ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 86.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8566,  Location: 0.5 MI W OF REED CITY (Lat: 43.873136,  Lng: -85.530789),  Route carried "on" structure: US 131,  Year Built: 1984,  Status: Open,  Structure Length: 3.04m (9.97ft),  Average Daily Traffic: 6,322 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 10,456 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: CHIPPEWA RD (4 MILE RD)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.531,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.4m (99.7ft),  Curb-To-Curb Width: 13.6m (44.6ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 86.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8567,  Location: 1.5 MI NW OF REED CITY (Lat: 43.887433,  Lng: -85.527653),  Route carried "on" structure: US 131,  Year Built: 1984,  Status: Open,  Structure Length: 3.38m (11.09ft),  Average Daily Traffic: 6,391 (year 2007),  Truck Traffic: 14%,  Average Future Daily Traffic: 9,660 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: US-10
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.155,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.8m (110.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 72.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8568,  Location: 1.5 MI NW OF REED CITY (Lat: 43.887433,  Lng: -85.528111),  Route carried "on" structure: US 131,  Year Built: 1984,  Status: Open,  Structure Length: 3.29m (10.79ft),  Average Daily Traffic: 6,391 (year 2007),  Truck Traffic: 14%,  Average Future Daily Traffic: 9,660 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: US-10
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.152,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 32.9m (107.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 69.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8569,  Location: 2.4 MI N OF REED CITY (Lat: 43.914275,  Lng: -85.521933),  Route carried "on" structure: US 131,  Year Built: 1985,  Status: Open,  Structure Length: 3.81m (12.50ft),  Average Daily Traffic: 11,841 (year 2013),  Truck Traffic: 10%,  Average Future Daily Traffic: 9,660 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: HERSEY CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.190,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 71.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 857,  Location: 2.4 MI N OF REED CITY (Lat: 43.914567,  Lng: -85.522281),  Route carried "on" structure: US 131,  Year Built: 1985,  Status: Open,  Structure Length: 3.81m (12.50ft),  Average Daily Traffic: 11,841 (year 2013),  Truck Traffic: 10%,  Average Future Daily Traffic: 9,660 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: HERSEY CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.221,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 64.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8573,  Location: 4.5 MI N OF REED CITY (Lat: 43.944631,  Lng: -85.520861),  Route carried "on" structure: US 131,  Year Built: 1985,  Status: Open,  Structure Length: 2.90m (9.51ft),  Average Daily Traffic: 6,391 (year 2007),  Truck Traffic: 14%,  Average Future Daily Traffic: 9,660 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: PENASHA RD (9 MILE RD)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 14.639,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.9m (94.8ft),  Curb-To-Curb Width: 13.6m (44.6ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 72.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 18 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8575,  Location: 2.5 MI N OF REED CITY (Lat: 43.916275,  Lng: -85.521147),  Route carried "on" structure: US 131,  Year Built: 1985,  Status: Open,  Structure Length: 3.23m (10.60ft),  Average Daily Traffic: 6,391 (year 2007),  Truck Traffic: 14%,  Average Future Daily Traffic: 9,660 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: GRAND AVE (7 MILE RD)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.420,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 8),  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 32.3m (106.0ft),  Curb-To-Curb Width: 13.5m (44.3ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 70.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8576,  Location: 2.5 MI N OF REED CITY (Lat: 43.916239,  Lng: -85.521647),  Route carried "on" structure: US 131,  Year Built: 1985,  Status: Open,  Structure Length: 3.23m (10.60ft),  Average Daily Traffic: 6,391 (year 2007),  Truck Traffic: 14%,  Average Future Daily Traffic: 9,660 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: GRAND AVE (7 MILE RD)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.414,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 32.3m (106.0ft),  Curb-To-Curb Width: 13.5m (44.3ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 59.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8577,  Location: 4.5 MI N OF REED CITY (Lat: 43.944619,  Lng: -85.521392),  Route carried "on" structure: US 131,  Year Built: 1985,  Status: Open,  Structure Length: 2.87m (9.42ft),  Average Daily Traffic: 6,391 (year 2007),  Truck Traffic: 14%,  Average Future Daily Traffic: 9,660 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: PENASHA RD (9 MILE RD)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 14.620,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 184,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.6m (93.8ft),  Curb-To-Curb Width: 13.6m (44.6ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 71.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8578,  Location: 1.8 MI NW OF REED CITY (Lat: 43.887450,  Lng: -85.530206),  Route carried "on" structure: US 10,  Year Built: 1947,  Year Reconstructed: 1984,  Status: Open,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 5,822 (year 2007),  Truck Traffic: 7%,  Average Future Daily Traffic: 5,816 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: JOHNSON CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.583,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 129,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 18.0m (59.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.6m (34.8ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 18.6m (61.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Fair,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 62.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8579,  Location: IN REED CITY (Lat: 43.885025,  Lng: -85.512736),  Route carried "on" structure: US 10,  Year Built: 1958,  Year Reconstructed: 1985,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 6,569 (year 2013),  Truck Traffic: 9%,  Average Future Daily Traffic: 8,648 (year 2018),  Design Load: HS 20,  Features Intersected: HERSEY RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.036,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 129,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 18.0m (59.1ft),  Out-to-Out Width: 19.0m (62.3ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 858,  Location: IN REED CITY (Lat: 43.870442,  Lng: -85.494183),  Route carried "on" structure: Business US 10,  Year Built: 1996,  Status: Open,  Structure Length: 1.82m (5.97ft),  Average Daily Traffic: 2,420 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 3,820 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: HERSEY RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.359,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.2m (59.7ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 80.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8608,  Location: SECTION 29/32 T18N R10W (Lat: 43.916175,  Lng: -85.523783),  Route carried "on" structure: County highway 6726,  Year Built: 2001,  Status: Open,  Structure Length: 1.50m (4.92ft),  Average Daily Traffic: 460 (year 2002),  Average Future Daily Traffic: 830 (year 2020),  Design Load: HS 20,  Features Intersected: HERSEY CREEK,  Facility Carried by Structure: 7 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.095,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.8m (45.3ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 74.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8631,  Location: SECTION 21 T18N R10W (Lat: 43.937467,  Lng: -85.517283),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 27 (year 2000),  Average Future Daily Traffic: 48 (year 2020),  Design Load: HS 20+Mod,  Features Intersected: LINCOLN CREEK,  Facility Carried by Structure: ORONO ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.314,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8632,  Location: SECTION 20/29 T18N R10W (Lat: 43.930214,  Lng: -85.528217),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 64 (year 2000),  Average Future Daily Traffic: 115 (year 2020),  Design Load: HS 20,  Features Intersected: HERSEY CREEK,  Facility Carried by Structure: 8 MILE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.749,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.7m (31.8ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 8633,  Location: SECTION 33 T18N R10W (Lat: 43.913958,  Lng: -85.521292),  Route carried "on" structure: County highway ,  Year Built: 1985,  Status: Open,  Structure Length: 2.13m (6.99ft),  Average Daily Traffic: 891 (year 2017),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,900 (year 2037),  Design Load: HS 25 or greater,  Features Intersected: HERSEY RIVER,  Facility Carried by Structure: 220 TH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.946,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.4m (66.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8651,  Location: SECTION 14 T17N R10W (Lat: 43.867481,  Lng: -85.483228),  Route carried "on" structure: County highway ,  Year Built: 1992,  Status: Open,  Structure Length: 3.05m (10.01ft),  Average Daily Traffic: 217 (year 2017),  Truck Traffic: 15%,  Average Future Daily Traffic: 410 (year 2037),  Design Load: HS 20,  Features Intersected: HERSEY RIVER,  Facility Carried by Structure: 200 TH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.820,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.3m (96.1ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 75.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 8657,  Location: IN REED CITY 0.3MI S.OF10 (Lat: 43.875494,  Lng: -85.503300),  Route carried "on" structure: Business City street ,  Year Built: 1979,  Status: Open,  Structure Length: 2.74m (8.99ft),  Average Daily Traffic: 400 (year 1990),  Truck Traffic: 2%,  Average Future Daily Traffic: 600 (year 2010),  Design Load: HS 20+Mod,  Features Intersected: HERSEY RIVER,  Facility Carried by Structure: ROTH STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.496,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 51.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 13254,  Location: RICHMOND TWP SEC 15 (Lat: 43.867681,  Lng: -85.490192),  Route carried "on" structure: County highway ,  Year Built: 2011,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 152 (year 2016),  Truck Traffic: 3%,  Average Future Daily Traffic: 300 (year 2036),  Features Intersected: HERSEY CREEK,  Facility Carried by Structure: TWIN CREEK ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.634,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 82.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 63.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss Reed City, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.