Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Peridot, Arizona (AZ)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 51Number of bridges
  • 420ft / 128mTotal length
  • $8,186,000Total costs
  • 32,464Total average daily traffic
  • 2,958Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Peridot
  • No street view available for this location

New bridges in Peridot, AZ - historical statistics
  • New bridges - historical statistics
  • 321920-1929
  • 11930-1939
  • 41950-1959
  • 61960-1969
  • 21980-1989
  • 31990-1999
  • 32010-2019
Average Bridge Daily Traffic in Peridot, AZ
Average Bridge Truck Traffic in Peridot, AZ
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 3.7%Good
  • 48.1%Satisfactory
  • 33.3%Fair
  • 14.8%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 3.7%Very good
  • 3.7%Good
  • 40.7%Satisfactory
  • 25.9%Fair
  • 18.5%Poor
  • 3.7%Critical
  • 3.7%Imminent failure
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 7.4%Very good
  • 70.4%Satisfactory
  • 11.1%Fair
  • 11.1%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 6.1%Very good
  • 20.4%Good
  • 32.7%Satisfactory
  • 32.7%Fair
  • 8.2%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 4.3%Very good
  • 47.8%Good
  • 43.5%Satisfactory
  • 4.3%Fair
Find on map >>   Show street view

Structure Number: H164,  Location: 4.2 KM S OF AZ 70/170 JCT (Lat: 33.261306,  Lng: -110.463806),  Route carried "on" structure: Federal lands road 3,  Year Built: 1969,  Status: Posted for load-capacity,  Structure Length: 6.41m (21.03ft),  Average Daily Traffic: 514 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 720 (year 2039),  Design Load: HS 20,  Features Intersected: BOOT WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 30.123,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 10.7m (35.1ft),  Curb-To-Curb Width: 10.0m (32.8ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 44.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: H167,  Location: 16 KM SOUTH OF HWY 70 (Lat: 33.196667,  Lng: -110.525917),  Route carried "on" structure: Federal lands road 3,  Year Built: 1930,  Status: Posted for load-capacity,  Structure Length: 4.74m (15.55ft),  Average Daily Traffic: 514 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 743 (year 2038),  Features Intersected: SODA SPRINGS GULCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 40.300,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 9.5m (31.2ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: No rating analysis performed,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: No rating analysis performed,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: H168,  Location: 2.4 KM E OF DAM SPILLWAY (Lat: 33.171250,  Lng: -110.503583),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 0.63m (2.07ft),  Average Daily Traffic: 390 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 456 (year 2039),  Design Load: H 15,  Features Intersected: GULCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.240,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 6.0m (19.7ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Channel: Poor,  Culverts: Good,  Operating Rating: 33.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: H169,  Location: 3.4 KM E OF COOLIDGE DAM (Lat: 33.167778,  Lng: -110.495056),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 0.90m (2.95ft),  Average Daily Traffic: 390 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 507 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 48.305,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.0m (29.5ft),  Curb-To-Curb Width: 6.0m (19.7ft),  Out-to-Out Width: 22.2m (72.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 36.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: H17,  Location: 4.3 KM E OF COOLIDGE DAM (Lat: 33.163250,  Lng: -110.487111),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 2.45m (8.04ft),  Average Daily Traffic: 390 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 510 (year 2039),  Design Load: H 15,  Features Intersected: ROCKHOUSE CANYON
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 49.060,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 6.3m (20.7ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.0m (39.4ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 25.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 18.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H171,  Location: 9.8 KM E OF COOLIDGE DAM (Lat: 33.163139,  Lng: -110.439361),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 3.04m (9.97ft),  Average Daily Traffic: 390 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 507 (year 2039),  Design Load: H 15,  Features Intersected: SQUAW CANYON
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 54.640,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 6.5m (21.3ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.6m (24.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 33.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H172,  Location: 11 KM E OF COOLIDGE DAM (Lat: 33.157417,  Lng: -110.431500),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 2.01m (6.59ft),  Average Daily Traffic: 390 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 507 (year 2039),  Design Load: H 15,  Features Intersected: COTTONWOOD CANYON
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 55.720,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 5.7m (18.7ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 6.7m (22.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.6m (24.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 33.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H173,  Location: 15 KM E OF COOLIDGE DAM (Lat: 33.159383,  Lng: -110.408383),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 2.68m (8.79ft),  Average Daily Traffic: 390 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 507 (year 2039),  Design Load: H 15,  Features Intersected: KELLY GULCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 59.720,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 6.7m (22.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.6m (24.9ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 33.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Length Of Structure Improvement: 3.00m (9.84ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Bridge Improvement Cost: $990,000,  Roadway Improvement Cost: $100,000,  Total Project Cost: $1,290,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: H175,  Location: 17.9 KM E OF COOLIDGE DAM (Lat: 33.169417,  Lng: -110.380444),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 350 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 455 (year 2039),  Design Load: H 15,  Features Intersected: MAVERICK DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 62.670,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 5.3m (17.4ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 5.5m (18.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 33.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: H176,  Location: 11.6 MI E DAM SPILLWAY (Lat: 33.172167,  Lng: -110.373361),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 350 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 410 (year 2039),  Design Load: H 15,  Features Intersected: GULCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 63.430,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 32.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H177,  Location: 19.8 KM E OF DAM SPILLWAY (Lat: 33.178278,  Lng: -110.363417),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 350 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 410 (year 2039),  Design Load: H 15,  Features Intersected: GULCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 64.580,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 32.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H178,  Location: 20 KM E OF COOLIDGE DAM (Lat: 33.179306,  Lng: -110.361889),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 350 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 410 (year 2039),  Design Load: H 15,  Features Intersected: MAVERICK GULCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 64.770,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.5m (21.3ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 33.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H179,  Location: 20.6 KM E OF COOLIDGE DAM (Lat: 33.182722,  Lng: -110.356028),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 2.44m (8.01ft),  Average Daily Traffic: 350 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 410 (year 2039),  Design Load: H 15,  Features Intersected: ROAD HOUSE CANYON
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 65.410,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 5.3m (17.4ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Poor,  Operating Rating: 33.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H18,  Location: 22.9 KM E OF COOLIDGE DAM (Lat: 33.188833,  Lng: -110.333111),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 350 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 410 (year 2039),  Design Load: H 15,  Features Intersected: SHERMAN DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 67.700,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 5.4m (17.7ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 33.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H181,  Location: 23.2 KM E OF DAM SPILLWAY (Lat: 33.189917,  Lng: -110.331222),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 2.44m (8.01ft),  Average Daily Traffic: 350 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 410 (year 2039),  Design Load: H 15,  Features Intersected: SYCAMORE GULCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 67.900,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.6m (24.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 33.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H182,  Location: 24.1 KM OF COOLIDGE DAM (Lat: 33.195472,  Lng: -110.324278),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 350 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 410 (year 2039),  Design Load: H 15,  Features Intersected: GULCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 68.880,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 32.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H183,  Location: 25.1 KM E OF COOLIDGE DAM (Lat: 33.196639,  Lng: -110.313333),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 1.24m (4.07ft),  Average Daily Traffic: 210 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 250 (year 2039),  Design Load: H 15,  Features Intersected: J K GULCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 69.950,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.1m (39.7ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 25.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 21.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H184,  Location: 25.7 KM E OF COOLIDGE DAM (Lat: 33.195194,  Lng: -110.307222),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 1.21m (3.97ft),  Average Daily Traffic: 210 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 250 (year 2039),  Design Load: H 15,  Features Intersected: RAILROAD TRAIL WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 70.550,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.9m (19.4ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.6m (24.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 33.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H185,  Location: 26.9 KM E OF COOLIDGE DAM (Lat: 33.192444,  Lng: -110.295833),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 1.21m (3.97ft),  Average Daily Traffic: 210 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 250 (year 2039),  Design Load: H 15,  Features Intersected: BEE SPRING DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 71.720,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.0m (19.7ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 7.6m (24.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 33.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H186,  Location: 27.6 KM E OF COOLIDGE DAM (Lat: 33.189944,  Lng: -110.290444),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 2.50m (8.20ft),  Average Daily Traffic: 210 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 254 (year 2039),  Design Load: H 15,  Features Intersected: TWIN DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 72.320,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 4.2m (13.8ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.3m (40.4ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 20.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 14.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H187,  Location: 29.6 KM E OF COOLIDGE DAM (Lat: 33.190972,  Lng: -110.269444),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 2.44m (8.01ft),  Average Daily Traffic: 210 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 250 (year 2039),  Design Load: H 15,  Features Intersected: ACORN DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 74.430,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 5.3m (17.4ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 11.9m (39.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 25.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 18.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Length Of Structure Improvement: 2.50m (8.20ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Bridge Improvement Cost: $758,000,  Roadway Improvement Cost: $150,000,  Total Project Cost: $1,073,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H188,  Location: 30.3 KM E DAM SPILLWAY (Lat: 33.192194,  Lng: -110.263417),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 210 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 246 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 75.010,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 6.8m (22.3ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 33.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: H189,  Location: 31.7 KM E OF COOLIDGE DAM (Lat: 33.192861,  Lng: -110.246583),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 3.32m (10.89ft),  Average Daily Traffic: 120 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 140 (year 2039),  Design Load: H 15,  Features Intersected: DEWEY FLAT DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 76.590,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 6.7m (22.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 33.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: H19,  Location: 33.7 KM E OF DAM SPILLWAY (Lat: 33.181333,  Lng: -110.231778),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 120 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 140 (year 2039),  Design Load: H 15,  Features Intersected: GULCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 78.480,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 44.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H191,  Location: 34.1 KM E OF DAM SPILLWAY (Lat: 33.180194,  Lng: -110.227250),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 120 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 140 (year 2039),  Design Load: H 15,  Features Intersected: GULCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 78.930,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 7.4m (24.3ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 44.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H193,  Location: 35.5 KM E OF COOLIDGE DAM (Lat: 33.178500,  Lng: -110.214222),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 3.89m (12.76ft),  Average Daily Traffic: 120 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 142 (year 2039),  Design Load: H 15,  Features Intersected: CALVA WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 80.180,  Lanes on structure: 1,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 3.3m (10.8ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 9.7m (31.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 3.3m (10.8ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Fair,  Superstructure: Critical,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 15.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 11.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: High priority of replacement,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: High priority of corrective action,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 4.00m (13.12ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $1,305,000,  Roadway Improvement Cost: $155,000,  Total Project Cost: $1,775,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H194,  Location: 36.3 KM E OF COOLIDGE DAM (Lat: 33.179278,  Lng: -110.205472),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Closed,  Structure Length: 4.62m (15.16ft),  Average Daily Traffic: 120 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 142 (year 2039),  Design Load: H 15,  Features Intersected: OAK DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 81.060,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 5.8m (19.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Satisfactory,  Superstructure: Imminent failure,  Substructure: Satisfactory,  Channel: Satisfactory,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: High priority of replacement,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 5.00m (16.40ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Total Project Cost: $2,020,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H195,  Location: 38.1 KM E DAM SPILLWAY (Lat: 33.180583,  Lng: -110.185028),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 120 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 140 (year 2039),  Design Load: H 15,  Features Intersected: WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 82.980,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 5.7m (18.7ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 33.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: No rating analysis performed,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: H196,  Location: 39.1 KM E OF COOLIDGE DAM (Lat: 33.177206,  Lng: -110.175975),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load,  Structure Length: 2.01m (6.59ft),  Average Daily Traffic: 120 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 140 (year 2039),  Design Load: H 15,  Features Intersected: HINT CANYON
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 83.910,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 6.7m (22.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Poor,  Channel: Satisfactory,  Operating Rating: 16.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 12.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 3.00m (9.84ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Bridge Improvement Cost: $925,000,  Roadway Improvement Cost: $100,000,  Total Project Cost: $1,260,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: H197,  Location: 40.4 KM E OF COOLIDGE DAM (Lat: 33.171694,  Lng: -110.164278),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 3.53m (11.58ft),  Average Daily Traffic: 120 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 140 (year 2039),  Design Load: H 15,  Features Intersected: BASIN WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 85.190,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 5.1m (16.7ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 9.7m (31.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 28.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: H198,  Location: 41.4 KM E OF COOLIDGE DAM (Lat: 33.166083,  Lng: -110.155250),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 120 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 140 (year 2039),  Design Load: H 15,  Features Intersected: BEARGRASS DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 86.250,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 4.8m (15.7ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.7m (31.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.5m (21.3ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 28.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 21.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: H199,  Location: 43.1 KM E OF COOLIDGE DAM (Lat: 33.159194,  Lng: -110.139500),  Route carried "on" structure: Federal lands road 3,  Year Built: 1929,  Status: Posted for load-capacity,  Structure Length: 4.02m (13.19ft),  Average Daily Traffic: 120 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 140 (year 2039),  Design Load: H 15,  Features Intersected: NAVAJO POINT DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 87.890,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 6.0m (19.7ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 29.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 21.9 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: H201,  Location: 3.4 KM NE OF JCT HWY 70 (Lat: 33.311389,  Lng: -110.351750),  Route carried "on" structure: Federal lands road 8,  Year Built: 1965,  Status: Open,  Structure Length: 0.77m (2.53ft),  Average Daily Traffic: 170 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 200 (year 2036),  Design Load: HS 20,  Features Intersected: TRIPLET WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.430,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 8.0m (26.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 44.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: H202,  Location: 15.3 KM NE OF JCT 70 (Lat: 33.386917,  Lng: -110.277417),  Route carried "on" structure: Federal lands road 8,  Year Built: 1965,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 170 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 200 (year 2038),  Design Load: HS 20,  Features Intersected: WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.370,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 8.3m (27.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 8.3m (27.2ft),  Out-to-Out Width: 14.2m (46.6ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 44.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: H203,  Location: 19.4 KM NE OF AZ 70 JCT (Lat: 33.393944,  Lng: -110.237139),  Route carried "on" structure: Federal lands road 8,  Year Built: 1965,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 170 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 200 (year 2038),  Design Load: HS 20,  Features Intersected: WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.240,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 19.3m (63.3ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: H204,  Location: 25.8 KM NE OF AZ 70 JCT (Lat: 33.394058,  Lng: -110.170769),  Route carried "on" structure: Federal lands road 8,  Year Built: 1965,  Status: Open,  Structure Length: 0.96m (3.15ft),  Average Daily Traffic: 170 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 200 (year 2038),  Design Load: HS 20,  Features Intersected: BRONCHO WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 25.840,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 8.6m (28.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.1m (10.2ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 39.0m (128.0ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 90.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 66.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: H205,  Location: 32.9 KM FROM AZ 70 JCT (Lat: 33.369453,  Lng: -110.103439),  Route carried "on" structure: Federal lands road 8,  Year Built: 1965,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 170 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 200 (year 2038),  Design Load: HS 20,  Features Intersected: JUNIPER WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 32.940,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 8.3m (27.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 8.3m (27.2ft),  Out-to-Out Width: 21.9m (71.9ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: H209,  Location: 12.4 KM S OF AZ 70/170JCT (Lat: 33.218528,  Lng: -110.507111),  Route carried "on" structure: Federal lands road 3,  Year Built: 1987,  Status: Posted for load-capacity,  Structure Length: 1.35m (4.43ft),  Average Daily Traffic: 514 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 720 (year 2038),  Design Load: HS 20,  Features Intersected: SANDY WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 38.117,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.3m (10.8ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: H21,  Location: 19 KM SW OF SAN CARLOS AZ (Lat: 33.175278,  Lng: -110.528889),  Route carried "on" structure: Federal lands road 3,  Year Built: 1928,  Year Reconstructed: 1995,  Status: Posted for load-capacity,  Structure Length: 5.30m (17.39ft),  Average Daily Traffic: 390 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 456 (year 2039),  Design Load: H 15,  Features Intersected: COOLIDGE DAM W. SPILLWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.000,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 4.5m (14.8ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.7m (58.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Poor,  Channel: Very good,  Operating Rating: 22.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 16.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Length Of Structure Improvement: 5.30m (17.39ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Total Project Cost: $386,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: H213,  Location: 19.2 KM SW SAN CARLOS AZ (Lat: 33.174861,  Lng: -110.526694),  Route carried "on" structure: Federal lands road 3,  Year Built: 1928,  Year Reconstructed: 1995,  Status: Posted for load-capacity,  Structure Length: 5.30m (17.39ft),  Average Daily Traffic: 390 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 456 (year 2039),  Design Load: H 15,  Features Intersected: E-SPILLWAY COOLIDGE DAM
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.200,  Lanes on structure: 2,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.7m (58.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Poor,  Channel: Very good,  Operating Rating: 22.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 16.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Length Of Structure Improvement: 5.30m (17.39ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Total Project Cost: $375,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: H58616B0821,  Location: 19KM NW OF POINT OF PINES (Lat: 33.466111,  Lng: -109.922861),  Route carried "on" structure: Federal lands road 4,  Year Built: 1990,  Status: Open,  Structure Length: 1.05m (3.44ft),  Average Daily Traffic: 10 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 11 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: WASH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 98.500,  Lanes on structure: 1,  Owner: Bureau of Indian Affairs,  Approaching Roadway Width: 4.0m (13.1ft),  Skew: 2 degrees,  Material/Design: Aluminum, Iron,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.8m (15.7ft),  Curb-To-Curb Width: 4.0m (13.1ft),  Out-to-Out Width: 16.0m (52.5ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 55.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Discuss Peridot, Arizona (AZ) on our hugely popular Arizona forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.