Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for New River, Arizona (AZ)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 72Number of bridges
  • 663ft / 202mTotal length
  • $2,000Total costs
  • 896,885Total average daily traffic
  • 88,199Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for New River
  • No street view available for this location

New bridges in New River, AZ - historical statistics
  • New bridges - historical statistics
  • 21940-1949
  • 11950-1959
  • 201960-1969
  • 21970-1979
  • 81980-1989
  • 111990-1999
  • 282000-2009
Reconstructed bridges in New River, AZ - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 41970-1979
  • 11980-1989
  • 21990-1999
  • 02000-2009
  • 12010-2019
Average Bridge Daily Traffic in New River, AZ
Average Bridge Truck Traffic in New River, AZ
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 50.0%Good
  • 45.0%Satisfactory
  • 5.0%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 5.0%Very good
  • 50.0%Good
  • 40.0%Satisfactory
  • 5.0%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 75.0%Good
  • 25.0%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 4.9%Very good
  • 80.3%Good
  • 13.1%Satisfactory
  • 1.6%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 2.2%Very good
  • 87.0%Good
  • 10.9%Satisfactory
Find on map >>   Show street view

Structure Number: 339,  Location: 14.6 mi N Jct SR 74 (Lat: 34.004100,  Lng: -112.140900),  Route carried "on" structure: Interstate 17,  Year Built: 1950,  Status: Open,  Structure Length: 5.43m (17.81ft),  Average Daily Traffic: 20,210 (year 2021),  Truck Traffic: 26%,  Average Future Daily Traffic: 20,220 (year 2041),  Design Load: HS 20,  Features Intersected: Moores Gulch
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 383.989,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.4m (66.9ft),  Curb-To-Curb Width: 9.7m (31.8ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Very good,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.95m (22.80ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $1,000,  Total Project Cost: $1,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 967,  Location: 14.2 mi N Jct SR 74 (Lat: 33.999500,  Lng: -112.134000),  Route carried "on" structure: Interstate 17,  Year Built: 1967,  Status: Open,  Structure Length: 5.94m (19.49ft),  Average Daily Traffic: 22,300 (year 2019),  Truck Traffic: 26%,  Average Future Daily Traffic: 22,310 (year 2039),  Design Load: HS 20,  Features Intersected: Moores Gulch
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 383.346,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.3m (73.2ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 68.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1289,  Location: 1.5 mi North Jct SR 74 (Lat: 33.819800,  Lng: -112.141800),  Route carried "on" structure: County highway ,  Year Built: 1968,  Status: Open,  Structure Length: 6.83m (22.41ft),  Average Daily Traffic: 5,000 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,010 (year 2040),  Design Load: HS 20,  Features Intersected: I 17,  Facility Carried by Structure: Pioneer TI
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 33.5m (109.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 129,  Location: 7.4 mi North Jct SR 74 (Lat: 33.905300,  Lng: -112.146000),  Route carried "on" structure: Interstate 17,  Year Built: 1968,  Year Reconstructed: 1981,  Status: Open,  Structure Length: 10.58m (34.71ft),  Average Daily Traffic: 23,914 (year 2018),  Truck Traffic: 13%,  Average Future Daily Traffic: 23,924 (year 2038),  Design Load: HS 20,  Features Intersected: New River
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 372.402,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1291,  Location: 7.4 mi North Jct SR 74 (Lat: 33.905200,  Lng: -112.146400),  Route carried "on" structure: Interstate 17,  Year Built: 1968,  Year Reconstructed: 1981,  Status: Open,  Structure Length: 10.58m (34.71ft),  Average Daily Traffic: 23,952 (year 2018),  Truck Traffic: 13%,  Average Future Daily Traffic: 23,962 (year 2038),  Design Load: HS 20,  Features Intersected: New River
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 372.402,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1292,  Location: 8.0 mi N Jct SR 74 (Lat: 33.913500,  Lng: -112.145300),  Route carried "on" structure: Interstate 17,  Year Built: 1968,  Status: Open,  Structure Length: 4.85m (15.91ft),  Average Daily Traffic: 23,352 (year 2017),  Truck Traffic: 12%,  Average Future Daily Traffic: 23,362 (year 2037),  Design Load: HS 20,  Features Intersected: Lake Pleasant Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 373.400,  Lanes on structure: 2,  Lanes under structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 64.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1293,  Location: 8.0 mi N Jct SR 74 (Lat: 33.913400,  Lng: -112.145700),  Route carried "on" structure: Interstate 17,  Year Built: 1968,  Status: Open,  Structure Length: 4.42m (14.50ft),  Average Daily Traffic: 23,401 (year 2017),  Truck Traffic: 12%,  Average Future Daily Traffic: 23,411 (year 2037),  Design Load: HS 20,  Features Intersected: New River Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 373.400,  Lanes on structure: 2,  Lanes under structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 66.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1294,  Location: 11.9 mi N Jct SR 74 (Lat: 33.968200,  Lng: -112.128400),  Route carried "on" structure: County highway ,  Year Built: 1968,  Status: Open,  Structure Length: 4.60m (15.09ft),  Average Daily Traffic: 300 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 310 (year 2038),  Design Load: HS 20,  Features Intersected: I 17 SB,  Facility Carried by Structure: Table Mesa Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.3m (69.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 2537,  Location: 5.1 mi North Jct SR 74 (Lat: 33.870800,  Lng: -112.145700),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 6.71m (22.01ft),  Average Daily Traffic: 19,639 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 19,649 (year 2039),  Design Load: HS 20,  Features Intersected: I 17,  Facility Carried by Structure: Anthem Way
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 9,  Lanes under structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 36.6m (120.1ft),  Skew: 21 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.6m (107.0ft),  Curb or Sidewalk Widths: Left: 2.5m (8.2ft),  Right: 2.5m (8.2ft),  Curb-To-Curb Width: 36.6m (120.1ft),  Out-to-Out Width: 43.3m (142.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 70.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 2696,  Location: 3.0 mi North Jct SR 74 (Lat: 33.839700,  Lng: -112.143800),  Route carried "on" structure: Ramp Interstate 17,  Year Built: 2004,  Status: Open,  Structure Length: 9.94m (32.61ft),  Average Daily Traffic: 7,335 (year 2019),  Truck Traffic: 10%,  Average Future Daily Traffic: 7,345 (year 2039),  Design Load: HS 20,  Features Intersected: Deadman Wash,  Facility Carried by Structure: Daisy Mtn TI Rmp B
Minimum Vertical Clearance: 5.50m (18.04ft),  Kilometerpoint: 365.160,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 14.3m (46.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.9m (107.9ft),  Curb-To-Curb Width: 14.5m (47.6ft),  Out-to-Out Width: 15.4m (50.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 574,  Location: 7.2 mi N Jct SR 74 (Lat: 33.901900,  Lng: -112.146500),  Route carried "on" structure: Interstate 17,  Year Built: 1948,  Year Reconstructed: 1980,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 46,866 (year 2017),  Truck Traffic: 12%,  Average Future Daily Traffic: 46,876 (year 2037),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 372.230,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 21 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 60.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.37m (4.49ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2018,  Total Project Cost: $1,000 ( Estimate for 2018)
Find on map >>   Show street view

Structure Number: 5742,  Location: 8.5 mi N Jct SR 74 (Lat: 33.920000,  Lng: -112.144100),  Route carried "on" structure: Interstate 17,  Year Built: 1968,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 22,100 (year 2017),  Truck Traffic: 13%,  Average Future Daily Traffic: 22,110 (year 2038),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 374.237,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2018
Find on map >>   Show street view

Structure Number: 5743,  Location: 8.5 mi N Jct SR 74 (Lat: 33.921100,  Lng: -112.144800),  Route carried "on" structure: Interstate 17,  Year Built: 1968,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 22,571 (year 2017),  Truck Traffic: 13%,  Average Future Daily Traffic: 22,581 (year 2038),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 374.350,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2018
Find on map >>   Show street view

Structure Number: 5744,  Location: 9.9 mi N Jct SR 74 (Lat: 33.939300,  Lng: -112.140500),  Route carried "on" structure: Interstate 17,  Year Built: 1949,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 22,100 (year 2017),  Truck Traffic: 13%,  Average Future Daily Traffic: 22,110 (year 2038),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 376.490,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2018
Find on map >>   Show street view

Structure Number: 5745,  Location: 9.9 mi N Jct SR 74 (Lat: 33.940800,  Lng: -112.141300),  Route carried "on" structure: Interstate 17,  Year Built: 1968,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 22,571 (year 2017),  Truck Traffic: 13%,  Average Future Daily Traffic: 22,581 (year 2038),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 376.490,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2018
Find on map >>   Show street view

Structure Number: 5746,  Location: 14.7 mi N Jct SR 74 (Lat: 34.004800,  Lng: -112.134100),  Route carried "on" structure: Interstate 17,  Year Built: 1967,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 19,241 (year 2017),  Truck Traffic: 26%,  Average Future Daily Traffic: 19,251 (year 2038),  Design Load: HS 20,  Features Intersected: Wash
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 384.215,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2018
Find on map >>   Show street view

Structure Number: 7642,  Location: At 29th Ave (Lat: 33.921950,  Lng: -112.121917),  Route carried "on" structure: County highway ,  Year Built: 1989,  Status: Open,  Structure Length: 1.71m (5.61ft),  Average Daily Traffic: 2,937 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,947 (year 2038),  Design Load: HS 20,  Features Intersected: Wash,  Facility Carried by Structure: New River Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 5.5m (18.0ft)

Condition: Channel: Good,  Culverts: Good,  Inventory Rating: 98.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2019
Find on map >>   Show street view

Structure Number: 7643,  Location: 0.21 mi E/ 27th Ave (Lat: 33.922403,  Lng: -112.113817),  Route carried "on" structure: County highway ,  Year Built: 1989,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 2,937 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,947 (year 2038),  Design Load: HS 20,  Features Intersected: Wash,  Facility Carried by Structure: New River Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Good,  Culverts: Good,  Inventory Rating: 93.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2019
Find on map >>   Show street view

Structure Number: 8011,  Location: 450' W/ I-17 Frontage Rd (Lat: 33.914428,  Lng: -112.142303),  Route carried "on" structure: County highway ,  Year Built: 1968,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 4,873 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 4,883 (year 2038),  Design Load: HS 20,  Features Intersected: Wash,  Facility Carried by Structure: New River Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 49.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2019,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 864,  Location: 0.9 mi S/ New River (Lat: 33.901739,  Lng: -112.145878),  Route carried "on" structure: County highway ,  Year Built: 1969,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 2,275 (year 2018),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,285 (year 2038),  Design Load: HS 20,  Features Intersected: Wash,  Facility Carried by Structure: I-17 Frontage Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 68.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2019
Find on map >>   Show street view

Structure Number: 9538,  Location: 0.8 mi E Jct Central Hwy (Lat: 31.466900,  Lng: -109.684600),  Route carried "on" structure: County highway ,  Year Built: 1969,  Year Reconstructed: 2010,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 4,500 (year 2017),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,510 (year 2039),  Design Load: HS 20,  Features Intersected: Desert Wash,  Facility Carried by Structure: Double Adobe Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 9613,  Location: 0.1 mi S Jct Dbl Adobe Rd (Lat: 31.465100,  Lng: -109.698400),  Route carried "on" structure: County highway ,  Year Built: 1980,  Status: Open,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 800 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 810 (year 2041),  Design Load: HS 20,  Features Intersected: Whitewater Draw,  Facility Carried by Structure: Central Hwy
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 9615,  Location: 0.1 mi S Jct Ajo Way (Lat: 32.175917,  Lng: -111.003056),  Route carried "on" structure: City street ,  Year Built: 1969,  Year Reconstructed: 1977,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 7,936 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,946 (year 2039),  Design Load: HS 20,  Features Intersected: Ajo Wash,  Facility Carried by Structure: Mission Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 28.0m (91.9ft),  Skew: 22 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 2.9m (9.5ft),  Right: 3.2m (10.5ft),  Curb-To-Curb Width: 28.0m (91.9ft),  Out-to-Out Width: 34.7m (113.8ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 9823,  Location: 0.5 mi W of Power Rd (Lat: 33.379333,  Lng: -111.696667),  Route carried "on" structure: City street ,  Year Built: 1983,  Status: Open,  Structure Length: 4.57m (14.99ft),  Average Daily Traffic: 19,867 (year 2019),  Truck Traffic: 10%,  Average Future Daily Traffic: 19,877 (year 2039),  Design Load: HS 20,  Features Intersected: RWCD Floodway,  Facility Carried by Structure: Baseline Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 10.1m (33.1ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Fair,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 9824,  Location: 1.7 mi N/ Thomas (Lat: 33.504989,  Lng: -111.684133),  Route carried "on" structure: County highway ,  Year Built: 1983,  Status: Open,  Structure Length: 3.19m (10.47ft),  Average Daily Traffic: 2,952 (year 2019),  Truck Traffic: 10%,  Average Future Daily Traffic: 2,962 (year 2039),  Design Load: HS 20,  Features Intersected: FanninMcFar CAP Aqueduct,  Facility Carried by Structure: Bush Hwy
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 31.4m (103.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 24.2m (79.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Inventory Rating: 51.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 9825,  Location: 2 miles W/ Cave Creek Rd (Lat: 33.799203,  Lng: -111.995758),  Route carried "on" structure: County highway ,  Year Built: 1986,  Status: Open,  Structure Length: 10.79m (35.40ft),  Average Daily Traffic: 9,194 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 9,204 (year 2040),  Design Load: HS 20,  Features Intersected: Cave Creek Wash,  Facility Carried by Structure: Carefree Hwy WB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 85.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 9872,  Location: 0.1 mi E Silverbell Rd (Lat: 32.250600,  Lng: -111.011900),  Route carried "on" structure: City street ,  Year Built: 1979,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 24,583 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 24,593 (year 2040),  Design Load: HS 20,  Features Intersected: Brichta Wash,  Facility Carried by Structure: Grant Road
Minimum Vertical Clearance: 9.14m (29.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 23.2m (76.1ft),  Out-to-Out Width: 28.3m (92.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 52.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 9873,  Location: 200' N Speedway Blvd (Lat: 32.236600,  Lng: -111.021500),  Route carried "on" structure: City street ,  Year Built: 1980,  Status: Open,  Structure Length: 1.74m (5.71ft),  Average Daily Traffic: 6,342 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,352 (year 2040),  Design Load: HS 20,  Features Intersected: Anklam Wash,  Facility Carried by Structure: Greasewood Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 64.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 9882,  Location: 0.3 mi E Jct Higley Rd (Lat: 33.408400,  Lng: -111.713500),  Route carried "on" structure: City street ,  Year Built: 1970,  Year Reconstructed: 1984,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 15,727 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 15,737 (year 2039),  Design Load: HS 20,  Features Intersected: RWCD Canal,  Facility Carried by Structure: Broadway Road
Minimum Vertical Clearance: 9.14m (29.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 25.0m (82.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 9893,  Location: 250' W/ 24th St (Lat: 33.799175,  Lng: -112.031275),  Route carried "on" structure: County highway ,  Year Built: 1985,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 13,867 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 13,877 (year 2037),  Design Load: HS 20,  Features Intersected: Wash,  Facility Carried by Structure: Carefree Hwy
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: County Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 55.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2018,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10021,  Location: 0.75 mi N/Venado Dr (Lat: 33.907081,  Lng: -112.083889),  Route carried "on" structure: County highway ,  Year Built: 1995,  Status: Open,  Structure Length: 11.19m (36.71ft),  Average Daily Traffic: 2,707 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,717 (year 2040),  Design Load: HS 20,  Features Intersected: Skunk Creek,  Facility Carried by Structure: New River Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 5 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 24.1m (79.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 25.6m (84.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 64.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 1005,  Location: 0.2 mi N/ Carefree Hwy (Lat: 33.802000,  Lng: -112.065400),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 4.11m (13.48ft),  Average Daily Traffic: 8,677 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 8,687 (year 2035),  Design Load: HS 20,  Features Intersected: Desert Lake Wash,  Facility Carried by Structure: 7th St
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 5 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 6.4m (21.0ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 68.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2018
Find on map >>   Show street view

Structure Number: 10051,  Location: N/ Carefree Hwy (Lat: 33.800300,  Lng: -112.065411),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 8,677 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 8,687 (year 2037),  Design Load: HS 20,  Features Intersected: Desert Lk Wash S Branch,  Facility Carried by Structure: 7th St
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 5 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.4m (21.0ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 86.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2018
Find on map >>   Show street view

Structure Number: 10083,  Location: S and N/ Circle Mtn Rd (Lat: 33.885767,  Lng: -112.072628),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 6.74m (22.11ft),  Average Daily Traffic: 2,707 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,717 (year 2040),  Design Load: HS 20,  Features Intersected: Cline Creek Wash,  Facility Carried by Structure: New River Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.6m (61.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 25.6m (84.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Inventory Rating: 60.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 10084,  Location: 0.6 mi E/ New River Rd (Lat: 33.886908,  Lng: -112.063272),  Route carried "on" structure: County highway ,  Year Built: 1996,  Status: Open,  Structure Length: 3.08m (10.10ft),  Average Daily Traffic: 4,166 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 4,176 (year 2038),  Design Load: HS 20,  Features Intersected: Wash,  Facility Carried by Structure: Circle Mtn Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 6 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 39.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10085,  Location: 0.2 mi S/ New River Rd (Lat: 33.911525,  Lng: -112.141069),  Route carried "on" structure: County highway ,  Year Built: 1997,  Status: Open,  Structure Length: 12.22m (40.09ft),  Average Daily Traffic: 2,454 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,464 (year 2040),  Design Load: HS 20,  Features Intersected: New River,  Facility Carried by Structure: I-17 Frontage Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 21.0m (68.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 10106,  Location: E of I-17 Frontage Rd (Lat: 33.918336,  Lng: -112.138703),  Route carried "on" structure: County highway ,  Year Built: 1997,  Status: Open,  Structure Length: 12.41m (40.72ft),  Average Daily Traffic: 5,477 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,487 (year 2040),  Design Load: HS 20,  Features Intersected: New River,  Facility Carried by Structure: New River Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 25.8m (84.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 10158,  Location: W/ 16th Street (Lat: 33.799114,  Lng: -112.049325),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 14,900 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 14,910 (year 2037),  Design Load: HS 20,  Features Intersected: Wash,  Facility Carried by Structure: Carefree Highway
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: County Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 23.8m (78.1ft),  Out-to-Out Width: 23.8m (78.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 64.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2018,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10159,  Location: 0.5 mi W/ 24th Street (Lat: 33.799150,  Lng: -112.038994),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 14,544 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 14,554 (year 2037),  Design Load: HS 20,  Features Intersected: Wash,  Facility Carried by Structure: Carefree Highway
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 21 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 62.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2018,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1016,  Location: 0.21 mi E/ 24th Street (Lat: 33.799186,  Lng: -112.026756),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 15,404 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 15,414 (year 2037),  Design Load: HS 20,  Features Intersected: Wash,  Facility Carried by Structure: Carefree Highway
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 20 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Inventory Rating: 74.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2018
Find on map >>   Show street view

Structure Number: 10369,  Location: 0.2 Mi E/GavilanPeakPkwy (Lat: 33.856797,  Lng: -112.134225),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 1,824 (year 2020),  Average Future Daily Traffic: 1,834 (year 2040),  Design Load: HS 20,  Features Intersected: Wash,  Facility Carried by Structure: Whitman Drive
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.2m (3.9ft)

Condition: Channel: Good,  Culverts: Good,  Inventory Rating: 92.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 10384,  Location: 300 ft N/ King Drive (Lat: 33.848328,  Lng: -112.138092),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 10,097 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 10,107 (year 2040),  Design Load: HS 20,  Features Intersected: Wash,  Facility Carried by Structure: Gavilan Peak Pkwy
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 21 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.4m (11.2ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 10385,  Location: 0.1 mi E/Gavilan Pk Pkwy (Lat: 33.853628,  Lng: -112.136225),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 3,610 (year 2020),  Average Future Daily Traffic: 3,620 (year 2040),  Design Load: HS 20,  Features Intersected: Wash,  Facility Carried by Structure: Memorial Drive
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.7m (12.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft)

Condition: Channel: Good,  Culverts: Good,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 10386,  Location: 0.3 mi E/Gavilan Pk Pkwy (Lat: 33.852147,  Lng: -112.133300),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 3,610 (year 2020),  Average Future Daily Traffic: 3,620 (year 2040),  Design Load: HS 20,  Features Intersected: Wash,  Facility Carried by Structure: Memorial Drive
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft)

Condition: Channel: Good,  Culverts: Good,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2021
Find on map >>   Show street view

Structure Number: 10388,  Location: 350 ft E of Republic Way (Lat: 33.852297,  Lng: -112.123594),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 3,464 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,474 (year 2040),  Design Load: HS 20,  Features Intersected: Split Flow Wash,  Facility Carried by Structure: Memorial Drive
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 2.4m (7.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 92.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 55.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2021