Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Hillsborough, North Carolina (NC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 84Number of bridges
  • 732ft / 223mTotal length
  • 1,560,418Total average daily traffic
  • 242,562Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Hillsborough
  • No street view available for this location

New bridges in Hillsborough, NC - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 31940-1949
  • 331950-1959
  • 41960-1969
  • 21970-1979
  • 241980-1989
  • 31990-1999
  • 42000-2009
  • 82010-2019
  • 22020-2022
Reconstructed bridges in Hillsborough, NC - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21970-1979
  • 11980-1989
Average Bridge Daily Traffic in Hillsborough, NC
Average Bridge Truck Traffic in Hillsborough, NC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 19.0%Very good
  • 23.8%Good
  • 38.1%Satisfactory
  • 19.0%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 2.4%Excellent
  • 21.4%Very good
  • 21.4%Good
  • 23.8%Satisfactory
  • 31.0%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 11.9%Very good
  • 14.3%Good
  • 33.3%Satisfactory
  • 38.1%Fair
  • 2.4%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 2.9%Excellent
  • 61.8%Good
  • 5.9%Satisfactory
  • 29.4%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 7.7%Very good
  • 15.4%Good
  • 69.2%Fair
  • 7.7%Poor
Find on map >>   Show street view

Structure Number: 1350221,  Location: 0.2 MI. W. JCT. SR1134 (Lat: 36.040864,  Lng: -79.143239),  Route carried "on" structure: State highway 1135,  Year Built: 2016,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 240 (year 2000),  Truck Traffic: 6%,  Average Future Daily Traffic: 480 (year 2040),  Design Load: HL 93,  Features Intersected: ROCKY RUN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 5.4m (17.7ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Length of Maximum Span: 3.6m (11.8ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 44.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: 1350228,  Location: 0.4 MI. N. JCT. SR1723 (Lat: 36.004839,  Lng: -79.107247),  Route carried "on" structure: State highway 1009,  Year Built: 1974,  Status: Posted for load,  Structure Length: 1.82m (5.97ft),  Average Daily Traffic: 4,800 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 9,600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: NEW HOPE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.7m (25.3ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 37.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1350241,  Location: .02 MI.SW. JCT.NC86 (Lat: 36.072567,  Lng: -79.099956),  Route carried "on" structure: City street ,  Year Built: 1922,  Status: Open,  Structure Length: 7.98m (26.18ft),  Average Daily Traffic: 100 (year 1985),  Average Future Daily Traffic: 200 (year 2040),  Design Load: H 15,  Features Intersected: ENO RIVER,  Facility Carried by Structure: EXCHANGE PARK LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 6.0m (19.7ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 21.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 135026,  Location: 2.1 MI. S. JCT. SR1009 (Lat: 36.009461,  Lng: -79.084314),  Route carried "on" structure: State highway 1723,  Year Built: 1986,  Status: Open,  Structure Length: 5.76m (18.90ft),  Average Daily Traffic: 4,800 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 9,600 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 80.163,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.4m (99.7ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 64.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1350262,  Location: 100 FT. S. JCT. SR1133 (Lat: 36.052614,  Lng: -79.122178),  Route carried "on" structure: State highway 1006,  Year Built: 1986,  Status: Open,  Structure Length: 6.15m (20.18ft),  Average Daily Traffic: 5,400 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 10,800 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I40
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 30.7m (100.7ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 66.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1350267,  Location: 0.99 MI. W. JCT. SR1006 (Lat: 36.059400,  Lng: -79.130411),  Route carried "on" structure: Ramp Interstate 40,  Year Built: 1987,  Status: Open,  Structure Length: 10.05m (32.97ft),  Average Daily Traffic: 14,333 (year 2015),  Truck Traffic: 16%,  Average Future Daily Traffic: 28,666 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I40E,I85E,  Facility Carried by Structure: I85S RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 49.622,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 40),  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 27.1m (88.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1350268,  Location: 0.77 MI. W. JCT. SR1006 (Lat: 36.059072,  Lng: -79.125675),  Route carried "on" structure: Interstate 40,  Year Built: 1987,  Status: Open,  Structure Length: 9.78m (32.09ft),  Average Daily Traffic: 31,500 (year 2019),  Truck Traffic: 16%,  Average Future Daily Traffic: 63,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: I85
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 78.761,  Lanes on structure: 2,  Lanes under structure: 7,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 40),  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Skew: 9 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 39.6m (129.9ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 82.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1350269,  Location: 1.5 MI. E. JCT. SR1120 (Lat: 36.062444,  Lng: -79.136994),  Route carried "on" structure: Interstate 40,  Year Built: 1957,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 1.21m (3.97ft),  Average Daily Traffic: 113,000 (year 2019),  Truck Traffic: 23%,  Average Future Daily Traffic: 226,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SEVEN MILE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 49.347,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 85),  Owner: State Highway Agency,  Approaching Roadway Width: 44.1m (144.7ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.1m (39.7ft)

Condition: Channel: Good,  Culverts: Fair,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 135027,  Location: 2.5 MI. E. JCT. I85 (Lat: 36.037050,  Lng: -79.097483),  Route carried "on" structure: Interstate 40,  Year Built: 1987,  Status: Open,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 38,000 (year 2017),  Truck Traffic: 16%,  Average Future Daily Traffic: 76,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR1009
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 79.553,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 40),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.5m (86.9ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1350271,  Location: 2.5 MI. E. JCT. I85 (Lat: 36.036817,  Lng: -79.097408),  Route carried "on" structure: Interstate 40,  Year Built: 1987,  Status: Open,  Structure Length: 5.02m (16.47ft),  Average Daily Traffic: 35,500 (year 2019),  Truck Traffic: 16%,  Average Future Daily Traffic: 71,000 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SR1009
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 79.553,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 40),  Owner: State Highway Agency,  Approaching Roadway Width: 12.4m (40.7ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 64.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 135034,  Location: 0.4 MI. S. JONES FERRY RD (Lat: 35.900214,  Lng: -79.086825),  Route carried "on" structure: City street ,  Year Built: 2010,  Status: Open,  Structure Length: 3.56m (11.68ft),  Average Daily Traffic: 3,800 (year 2017),  Truck Traffic: 7%,  Average Future Daily Traffic: 7,600 (year 2040),  Design Load: HS 20,  Features Intersected: TOM'S CREEK,  Facility Carried by Structure: BERRYHILL DR.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 17.9m (58.7ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 14.6m (47.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 73.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1350341,  Location: 0.4 MI. S. JCT. NC86 (Lat: 36.057972,  Lng: -79.089189),  Route carried "on" structure: Interstate 85,  Year Built: 1950,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 56,000 (year 2018),  Truck Traffic: 16%,  Average Future Daily Traffic: 112,000 (year 2040),  Design Load: HS 20,  Features Intersected: CATES CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 50.292,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 85),  Owner: State Highway Agency,  Approaching Roadway Width: 17.6m (57.7ft),  Skew: 24 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.1m (6.9ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 1350346,  Location: 0.2 MI. E. JCT. SR1009 (Lat: 36.048033,  Lng: -79.098647),  Route carried "on" structure: City street ,  Year Built: 2008,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 100 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 200 (year 2040),  Design Load: HS 20,  Features Intersected: CATES CREEK,  Facility Carried by Structure: CATES CREEK PKWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020
Find on map >>   Show street view

Structure Number: 1350059,  Location: 0.6 MI. S. JCT. US70 BUS (Lat: 36.058844,  Lng: -79.082361),  Route carried "under" structure: Interstate 85,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 28,250 (year 2019),  Truck Traffic: 16%,  Features Intersected: NC86
Minimum Vertical Clearance: 4.64m (15.22ft),  Kilometerpoint: 50.414,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.0m (78.7ft)

Find on map >>   Show street view

Structure Number: 1350059,  Location: 0.6 MI. S. JCT. US70 BUS (Lat: 36.058844,  Lng: -79.082361),  Route carried "under" structure: Interstate 85,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 28,250 (year 2019),  Truck Traffic: 16%,  Features Intersected: NC86
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 50.414,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.0m (78.7ft)

Find on map >>   Show street view

Structure Number: 1350079,  Location: 0.3 MI. S. JCT. I85 (Lat: 36.061606,  Lng: -79.135217),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 62,000 (year 2018),  Truck Traffic: 23%,  Features Intersected: SR1134
Minimum Vertical Clearance: 5.56m (18.24ft),  Kilometerpoint: 49.530,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.0m (128.0ft)

Find on map >>   Show street view

Structure Number: 1350079,  Location: 0.3 MI. S. JCT. I85 (Lat: 36.061606,  Lng: -79.135217),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 62,000 (year 2018),  Truck Traffic: 23%,  Features Intersected: SR1134
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 49.530,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.0m (128.0ft)

Find on map >>   Show street view

Structure Number: 1350081,  Location: 0.5 MI.S. JCT. SR1009 (Lat: 36.059006,  Lng: -79.112317),  Route carried "under" structure: State highway 1006,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 9,500 (year 2019),  Truck Traffic: 7%,  Features Intersected: I85N,NC86,  Facility Carried by Structure: H
Minimum Vertical Clearance: 4.39m (14.40ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.0m (68.9ft)

Find on map >>   Show street view

Structure Number: 1350082,  Location: 0.3 MI. S. JCT. SR1009 (Lat: 36.059214,  Lng: -79.111978),  Route carried "under" structure: State highway 1006,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 9,500 (year 2019),  Truck Traffic: 7%,  Features Intersected: I85S, NC86
Minimum Vertical Clearance: 5.43m (17.81ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.0m (68.9ft)

Find on map >>   Show street view

Structure Number: 1350083,  Location: 1.3 MI. N. JCT. I40 (Lat: 36.056950,  Lng: -79.104111),  Route carried "under" structure: State highway 1009,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 25,000 (year 2018),  Truck Traffic: 6%,  Features Intersected: I85N,NC86
Minimum Vertical Clearance: 4.59m (15.06ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.2m (49.9ft)

Find on map >>   Show street view

Structure Number: 1350087,  Location: 1.3 MI. N. JCT. I40 (Lat: 36.057131,  Lng: -79.104075),  Route carried "under" structure: State highway 1009,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 25,000 (year 2018),  Truck Traffic: 6%,  Features Intersected: I85S,NC86
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 15.2m (49.9ft)

Find on map >>   Show street view

Structure Number: 1350095,  Location: 0.3 MI. N. JCT. SR1710 (Lat: 36.053967,  Lng: -79.067794),  Route carried "under" structure: Interstate 85,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 28,000 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1709
Minimum Vertical Clearance: 4.87m (15.98ft),  Kilometerpoint: 50.688,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.3m (56.8ft)

Find on map >>   Show street view

Structure Number: 1350095,  Location: 0.3 MI. N. JCT. SR1710 (Lat: 36.053967,  Lng: -79.067794),  Route carried "under" structure: Interstate 85,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 28,000 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1709
Minimum Vertical Clearance: 5.56m (18.24ft),  Kilometerpoint: 50.688,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.3m (56.8ft)

Find on map >>   Show street view

Structure Number: 1350096,  Location: 0.2 MI. N. JCT. SR1817 (Lat: 36.041167,  Lng: -79.030758),  Route carried "under" structure: Interstate 85,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 26,750 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1712
Minimum Vertical Clearance: 4.92m (16.14ft),  Kilometerpoint: 51.420,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.5m (64.0ft)

Find on map >>   Show street view

Structure Number: 1350096,  Location: 0.2 MI. N. JCT. SR1817 (Lat: 36.041167,  Lng: -79.030758),  Route carried "under" structure: Interstate 85,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 26,750 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1712
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 51.420,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.5m (64.0ft)

Find on map >>   Show street view

Structure Number: 1350098,  Location: 0.5 MI. S. JCT. US70 (Lat: 36.038725,  Lng: -79.017208),  Route carried "under" structure: State highway 1713,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 2,900 (year 2019),  Truck Traffic: 6%,  Features Intersected: I85N
Minimum Vertical Clearance: 6.17m (20.24ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.4m (53.8ft)

Find on map >>   Show street view

Structure Number: 1350106,  Location: 0.65 MI. N. JCT. SR1567 (Lat: 36.038678,  Lng: -79.011917),  Route carried "under" structure: US 70,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 18,500 (year 2019),  Truck Traffic: 6%,  Features Intersected: I85S, US70W
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.1m (75.8ft)

Find on map >>   Show street view

Structure Number: 135011,  Location: 0.6 MI. N. JCT. SR1712 (Lat: 36.038367,  Lng: -79.008572),  Route carried "under" structure: Business US 70,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 7,700 (year 2018),  Truck Traffic: 6%,  Features Intersected: I85SN,US70E
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 51.755,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.8m (65.0ft)

Find on map >>   Show street view

Structure Number: 1350111,  Location: 0.6 MI. N. JCT. SR1712 (Lat: 36.038542,  Lng: -79.008781),  Route carried "under" structure: Business US 70,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 7,700 (year 2017),  Truck Traffic: 6%,  Features Intersected: I85 SBL
Minimum Vertical Clearance: 4.92m (16.14ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.7m (67.9ft)

Find on map >>   Show street view

Structure Number: 135026,  Location: 2.1 MI. S. JCT. SR1009 (Lat: 36.009461,  Lng: -79.084314),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 38,000 (year 2017),  Truck Traffic: 16%,  Features Intersected: SR1723
Minimum Vertical Clearance: 5.43m (17.81ft),  Kilometerpoint: 80.132,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.4m (99.7ft)

Find on map >>   Show street view

Structure Number: 135026,  Location: 2.1 MI. S. JCT. SR1009 (Lat: 36.009461,  Lng: -79.084314),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 38,000 (year 2017),  Truck Traffic: 16%,  Features Intersected: SR1723
Minimum Vertical Clearance: 6.85m (22.47ft),  Kilometerpoint: 80.132,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.4m (99.7ft)

Find on map >>   Show street view

Structure Number: 1350262,  Location: 100 FT. S. JCT. SR1133 (Lat: 36.052614,  Lng: -79.122178),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 31,500 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1006
Minimum Vertical Clearance: 5.58m (18.31ft),  Kilometerpoint: 78.913,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.7m (100.7ft)

Find on map >>   Show street view

Structure Number: 1350262,  Location: 100 FT. S. JCT. SR1133 (Lat: 36.052614,  Lng: -79.122178),  Route carried "under" structure: Interstate 40,  Year Built: 1986,  Structure Length: 0. m,  Average Daily Traffic: 31,500 (year 2019),  Truck Traffic: 16%,  Features Intersected: SR1006
Minimum Vertical Clearance: 5.30m (17.39ft),  Kilometerpoint: 78.913,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.7m (100.7ft)

Find on map >>   Show street view

Structure Number: 1350267,  Location: 0.99 MI. W. JCT. SR1006 (Lat: 36.059400,  Lng: -79.130411),  Route carried "under" structure: Interstate 85,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 49,500 (year 2015),  Truck Traffic: 16%,  Features Intersected: I85S RAMP
Minimum Vertical Clearance: 6.68m (21.92ft),  Kilometerpoint: 49.500,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.1m (88.9ft)

Find on map >>   Show street view

Structure Number: 1350267,  Location: 0.99 MI. W. JCT. SR1006 (Lat: 36.059400,  Lng: -79.130411),  Route carried "under" structure: Interstate 85,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 49,500 (year 2015),  Truck Traffic: 16%,  Features Intersected: I85S RAMP
Minimum Vertical Clearance: 7.18m (23.56ft),  Kilometerpoint: 49.500,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.1m (88.9ft)

Find on map >>   Show street view

Structure Number: 1350267,  Location: 0.99 MI. W. JCT. SR1006 (Lat: 36.059400,  Lng: -79.130411),  Route carried "under" structure: Interstate 40,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 33,000 (year 2015),  Truck Traffic: 16%,  Features Intersected: I85S RAMP
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 78.730,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.1m (88.9ft)

Find on map >>   Show street view

Structure Number: 1350268,  Location: 0.77 MI. W. JCT. SR1006 (Lat: 36.059072,  Lng: -79.125675),  Route carried "under" structure: Interstate 85,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 56,500 (year 2019),  Truck Traffic: 16%,  Features Intersected: I40W.
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 49.591,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.6m (129.9ft)

Find on map >>   Show street view

Structure Number: 1350268,  Location: 0.77 MI. W. JCT. SR1006 (Lat: 36.059072,  Lng: -79.125675),  Route carried "under" structure: Interstate 85,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 56,500 (year 2019),  Truck Traffic: 16%,  Features Intersected: I40W.
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 49.591,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.6m (129.9ft)

Find on map >>   Show street view

Structure Number: 135027,  Location: 2.5 MI. E. JCT. I85 (Lat: 36.037050,  Lng: -79.097483),  Route carried "under" structure: State highway 1009,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 7,500 (year 2017),  Truck Traffic: 6%,  Features Intersected: I40W
Minimum Vertical Clearance: 5.76m (18.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.5m (86.9ft)

Find on map >>   Show street view

Structure Number: 135027,  Location: 2.5 MI. E. JCT. I85 (Lat: 36.037050,  Lng: -79.097483),  Route carried "under" structure: State highway 1009,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 7,500 (year 2017),  Truck Traffic: 6%,  Features Intersected: I40W
Minimum Vertical Clearance: 5.91m (19.39ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.5m (86.9ft)

Find on map >>   Show street view

Structure Number: 1350271,  Location: 2.5 MI. E. JCT. I85 (Lat: 36.036817,  Lng: -79.097408),  Route carried "under" structure: State highway 1009,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 3,300 (year 2018),  Truck Traffic: 7%,  Features Intersected: I40E
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.8m (87.9ft)

Find on map >>   Show street view

Structure Number: 1350271,  Location: 2.5 MI. E. JCT. I85 (Lat: 36.036817,  Lng: -79.097408),  Route carried "under" structure: State highway 1009,  Year Built: 1987,  Structure Length: 0. m,  Average Daily Traffic: 3,300 (year 2018),  Truck Traffic: 7%,  Features Intersected: I40E
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.8m (87.9ft)

Discuss Hillsborough, North Carolina (NC) on our hugely popular North Carolina forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.