Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Gilroy, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 67Number of bridges
  • 892ft / 272mTotal length
  • $8,445,000Total costs
  • 1,337,021Total average daily traffic
  • 92,934Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Gilroy
  • No street view available for this location

New bridges in Gilroy, CA - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 11910-1919
  • 31920-1929
  • 41930-1939
  • 41940-1949
  • 61950-1959
  • 41960-1969
  • 231970-1979
  • 151980-1989
  • 41990-1999
  • 12000-2009
  • 12010-2019
Reconstructed bridges in Gilroy, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11940-1949
  • 11950-1959
  • 11960-1969
  • 01970-1979
  • 31980-1989
  • 71990-1999
  • 22000-2009
Average Bridge Daily Traffic in Gilroy, CA
Average Bridge Truck Traffic in Gilroy, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 56.6%Good
  • 15.1%Satisfactory
  • 22.6%Fair
  • 5.7%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 55.6%Good
  • 13.0%Satisfactory
  • 29.6%Fair
  • 1.9%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 85.2%Good
  • 1.9%Satisfactory
  • 11.1%Fair
  • 1.9%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 4.3%Excellent
  • 40.4%Very good
  • 17.0%Good
  • 19.1%Satisfactory
  • 10.6%Fair
  • 8.5%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 40.0%Good
  • 60.0%Satisfactory
Find on map >>   Show street view

Structure Number: 37C034,  Location: 0.1 MI S BENTON ST (Lat: 37.344131,  Lng: -121.995536),  Route carried "on" structure: County highway ,  Year Built: 1965,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 1.11m (3.64ft),  Average Daily Traffic: 74,520 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 79,926 (year 2042),  Features Intersected: CALABAZAS CREEK,  Facility Carried by Structure: LAWRENCE EXPWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 30.2m (99.1ft),  Skew: 22 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.7m (8.9ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 34.4m (112.9ft),  Out-to-Out Width: 46.3m (151.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020
Find on map >>   Show street view

Structure Number: 37C0349,  Location: N/O 6TH ST (Lat: 37.008989,  Lng: -121.562017),  Route carried "on" structure: City street ,  Year Built: 1982,  Status: Open,  Structure Length: 1.48m (4.86ft),  Average Daily Traffic: 1,041 (year 2012),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,010 (year 2037),  Features Intersected: MILLER SLOUGH,  Facility Carried by Structure: ROGERS LANE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.9m (45.6ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Poor,  Operating Rating: 48.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: December 2020,  Other Special Inspection Date: November 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0351,  Location: 1 MI W MONTEREY HWY (Lat: 37.037336,  Lng: -121.588511),  Route carried "on" structure: County highway ,  Year Built: 1988,  Status: Open,  Structure Length: 3.43m (11.25ft),  Average Daily Traffic: 4,990 (year 2011),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,662 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: WEST BRANCH LLAGAS CREEK,  Facility Carried by Structure: DAY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.1m (39.7ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0352,  Location: 0.2 MI W MONTEREY RD (Lat: 37.030456,  Lng: -121.584836),  Route carried "on" structure: City street ,  Year Built: 1989,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 3.44m (11.29ft),  Average Daily Traffic: 3,184 (year 2012),  Truck Traffic: 4%,  Average Future Daily Traffic: 6,100 (year 2037),  Features Intersected: WEST BRANCH LLAGAS CREEK,  Facility Carried by Structure: FARRELL AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 25.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 15.2 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0353,  Location: NW STATE ROUTE 88 (Lat: 37.027700,  Lng: -121.586642),  Route carried "on" structure: City street ,  Year Built: 1989,  Status: Open,  Structure Length: 2.26m (7.41ft),  Average Daily Traffic: 5,000 (year 2012),  Truck Traffic: 4%,  Average Future Daily Traffic: 6,000 (year 2037),  Design Load: HS 20+Mod,  Features Intersected: LIONS CREEK,  Facility Carried by Structure: WREN AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 19.2m (63.0ft),  Out-to-Out Width: 22.3m (73.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0354,  Location: JUST N/O TATUM AVE (Lat: 37.027828,  Lng: -121.591494),  Route carried "on" structure: County highway ,  Year Built: 1989,  Status: Open,  Structure Length: 2.22m (7.28ft),  Average Daily Traffic: 700 (year 2010),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,027 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: LIONS CREEK,  Facility Carried by Structure: KERN AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 11.7m (38.4ft),  Out-to-Out Width: 18.3m (60.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0355,  Location: JUST S/O DAY ROAD (Lat: 37.035269,  Lng: -121.597261),  Route carried "on" structure: County highway ,  Year Built: 1988,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 7,780 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 21,361 (year 2042),  Features Intersected: LIONS CREEK,  Facility Carried by Structure: SANTA TERESA BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.1m (10.2ft)

Condition: Channel: Very good,  Culverts: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2020
Find on map >>   Show street view

Structure Number: 37C0363,  Location: 0.2 MI N RONAN AVE (Lat: 37.027622,  Lng: -121.581817),  Route carried "on" structure: City street ,  Year Built: 1987,  Status: Open,  Structure Length: 3.00m (9.84ft),  Average Daily Traffic: 3,800 (year 2012),  Truck Traffic: 4%,  Average Future Daily Traffic: 4,352 (year 2037),  Design Load: HS 20+Mod,  Features Intersected: W BRANCH LLAGAS CREEK,  Facility Carried by Structure: CHURCH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.3m (37.1ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 16.2m (53.1ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C042,  Location: IN SHORELINE PARK (Lat: 37.431697,  Lng: -122.086756),  Route carried "on" structure: City street ,  Year Built: 1982,  Status: Open,  Structure Length: 1.61m (5.28ft),  Average Daily Traffic: 2,000 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,252 (year 2042),  Features Intersected: PERMANENTE CREEK,  Facility Carried by Structure: SHORELINE BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.9m (25.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022
Find on map >>   Show street view

Structure Number: 37C0427,  Location: 500 FT SOUTH OF GILMAN RD (Lat: 37.009461,  Lng: -121.554886),  Route carried "on" structure: City street ,  Year Built: 2009,  Status: Open,  Structure Length: 4.60m (15.09ft),  Average Daily Traffic: 25,100 (year 2012),  Truck Traffic: 5%,  Average Future Daily Traffic: 31,836 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: WEST BRANCH LLAGAS CREEK,  Facility Carried by Structure: CAMINO ARROYO ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Skew: 33 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 22.6m (74.1ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 2.1m (6.9ft),  Curb-To-Curb Width: 18.9m (62.0ft),  Out-to-Out Width: 26.8m (87.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0534,  Location: BLOOMFIELD AVE (Lat: 36.978372,  Lng: -121.508542),  Route carried "on" structure: County highway ,  Year Built: 1927,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 3,800 (year 2014),  Truck Traffic: 15%,  Average Future Daily Traffic: 5,323 (year 2040),  Features Intersected: FURLONG CREEK,  Facility Carried by Structure: FRAZIER LAKE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Poor,  Operating Rating: 26.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0535,  Location: 0.4 MI S/E BLOOMFIELD AVE (Lat: 36.974928,  Lng: -121.504853),  Route carried "on" structure: County highway ,  Year Built: 1927,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 3,800 (year 2014),  Truck Traffic: 10%,  Average Future Daily Traffic: 5,101 (year 2040),  Features Intersected: BRANCH OF PAJARO RIVER,  Facility Carried by Structure: FRAZIER LAKE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.0m (26.2ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.5m (18.0ft),  Curb-To-Curb Width: 7.8m (25.6ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 27.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Superior to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0536,  Location: 0.6 MI S/E BLOOMFIELD AVE (Lat: 36.972064,  Lng: -121.501611),  Route carried "on" structure: County highway ,  Year Built: 1927,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 3,800 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,101 (year 2040),  Features Intersected: PAJARO RIVER,  Facility Carried by Structure: FRAZIER LAKE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.3m (27.2ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Fair,  Operating Rating: 28.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 17.2 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0537,  Location: HOLSCLAW ROAD (Lat: 37.016958,  Lng: -121.543403),  Route carried "on" structure: County highway ,  Year Built: 1987,  Status: Open,  Structure Length: 4.77m (15.65ft),  Average Daily Traffic: 1,570 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,566 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: LLAGAS CREEK,  Facility Carried by Structure: GILMAN ROAD
Minimum Vertical Clearance: 3.66m (12.01ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.5m (24.6ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 11.7m (38.4ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: High priority of corrective action,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0562,  Location: 0.3 MI W WATSONVILLE RD (Lat: 37.028028,  Lng: -121.659275),  Route carried "on" structure: County highway ,  Year Built: 1909,  Status: Open,  Structure Length: 0.95m (3.12ft),  Average Daily Traffic: 400 (year 2011),  Truck Traffic: 5%,  Average Future Daily Traffic: 612 (year 2037),  Features Intersected: LITTLE ARTHUR CREEK,  Facility Carried by Structure: REDWOOD RETREAT RD
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.7m (18.7ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 5.7m (18.7ft)

Condition: Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 27.2 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020
Find on map >>   Show street view

Structure Number: 37C058,  Location: 0.6 MI W MONTEREY RD (Lat: 36.991572,  Lng: -121.572692),  Route carried "on" structure: County highway ,  Year Built: 1989,  Status: Open,  Structure Length: 8.09m (26.54ft),  Average Daily Traffic: 6,920 (year 2014),  Truck Traffic: 5%,  Average Future Daily Traffic: 9,239 (year 2042),  Design Load: HS 20,  Features Intersected: CARNADERO CREEK (UVAS),  Facility Carried by Structure: THOMAS/LUCHESSA RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 10.9m (35.8ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0582,  Location: 1.86 M S/O HECKER PASS RD (Lat: 36.985378,  Lng: -121.657300),  Route carried "on" structure: County highway ,  Year Built: 1939,  Status: Open,  Structure Length: 1.49m (4.89ft),  Average Daily Traffic: 70 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 84 (year 2037),  Features Intersected: BODFISH CREEK,  Facility Carried by Structure: WHITEHURST ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 31.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0583,  Location: 0.16 MI S/O HECKER PASS R (Lat: 37.004081,  Lng: -121.667317),  Route carried "on" structure: County highway ,  Year Built: 1939,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 70 (year 2011),  Truck Traffic: 2%,  Average Future Daily Traffic: 204 (year 2037),  Features Intersected: BODFISH CREEK,  Facility Carried by Structure: WHITEHURST ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 7.0m (23.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 25.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 15.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 43 0001,  Location: 05-SBT-025-60.04 (Lat: 36.947997,  Lng: -121.511772),  Route carried "on" structure: State highway 25,  Year Built: 1951,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 6.46m (21.19ft),  Average Daily Traffic: 18,000 (year 2009),  Truck Traffic: 10%,  Average Future Daily Traffic: 33,953 (year 2042),  Design Load: HS 20,  Features Intersected: PAJARO RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.040,  Lanes on structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 11.6m (38.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Poor,  Channel: Fair,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.46m (21.19ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Bridge Improvement Cost: $857,000,  Roadway Improvement Cost: $171,000,  Total Project Cost: $1,439,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 43C0033,  Location: 1.2 MILE N OF SHORE ROAD (Lat: 36.963422,  Lng: -121.491836),  Route carried "on" structure: County highway ,  Year Built: 1995,  Status: Open,  Structure Length: 2.18m (7.15ft),  Average Daily Traffic: 4,880 (year 2010),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,516 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: MILLERS CANAL,  Facility Carried by Structure: FRAZIER LAKE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.0m (32.8ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.6m (28.2ft),  Curb-To-Curb Width: 9.7m (31.8ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0304L,  Location: 04-SCL-101-R4.94 (Lat: 36.986775,  Lng: -121.558547),  Route carried "under" structure: County highway C218,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 5,000 (year 1998),  Truck Traffic: 3%,  Features Intersected: MONTEREY ROAD,  Facility Carried by Structure: U.S. HWY 101 (SB)
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 49.2m (161.4ft)

Find on map >>   Show street view

Structure Number: 37 0304R,  Location: 04-SCL-101-R4.94 (Lat: 36.986564,  Lng: -121.558150),  Route carried "under" structure: County highway C218,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 5,000 (year 1998),  Truck Traffic: 3%,  Features Intersected: MONTEREY ROAD,  Facility Carried by Structure: U.S. HWY 101 (NB)
Minimum Vertical Clearance: 4.80m (15.75ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 49.2m (161.4ft)

Find on map >>   Show street view

Structure Number: 37 0325,  Location: 04-SCL-152-R9.92-GIL (Lat: 37.002772,  Lng: -121.556967),  Route carried "under" structure: US 101,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 52,000 (year 2009),  Truck Traffic: 8%,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: SR 152 (10TH ST)
Minimum Vertical Clearance: 5.38m (17.65ft),  Kilometerpoint: 6.080,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 48.6m (159.4ft)

Find on map >>   Show street view

Structure Number: 37 0326,  Location: 04-SCL-101-R6.58-GIL (Lat: 37.009608,  Lng: -121.560161),  Route carried "under" structure: US 101,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 52,000 (year 2009),  Truck Traffic: 8%,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: 6TH STREET
Minimum Vertical Clearance: 5.28m (17.32ft),  Kilometerpoint: 6.580,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 48.5m (159.1ft)

Find on map >>   Show street view

Structure Number: 37 0328L,  Location: 04-SCL-101-R7.52-GIL (Lat: 37.022167,  Lng: -121.566650),  Route carried "under" structure: State highway 152,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 22,550 (year 1998),  Truck Traffic: 3%,  Features Intersected: STATE ROUTE 152,  Facility Carried by Structure: U.S. HWY 101 (SB)
Minimum Vertical Clearance: 4.87m (15.98ft),  Kilometerpoint: 9.730,  Lanes on structure: 3,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 48.5m (159.1ft)

Find on map >>   Show street view

Structure Number: 37 0328R,  Location: 04-SCL-101-R7.52-GIL (Lat: 37.022322,  Lng: -121.566236),  Route carried "under" structure: State highway 152,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 22,550 (year 1998),  Truck Traffic: 3%,  Features Intersected: STATE ROUTE 152,  Facility Carried by Structure: U.S. HWY 101 (NB)
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 9.730,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 48.5m (159.1ft)

Find on map >>   Show street view

Structure Number: 37 0329,  Location: 04-SCL-101-R9.13 (Lat: 37.043533,  Lng: -121.578139),  Route carried "under" structure: US 101,  Year Built: 1972,  Structure Length: 0. m,  Average Daily Traffic: 110,000 (year 2009),  Truck Traffic: 13%,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: BUENA VISTA AVENUE
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 9.130,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 35.1m (115.2ft)

Find on map >>   Show street view

Structure Number: 37 0468,  Location: 04-SCL-025-2.49 (Lat: 36.961414,  Lng: -121.550606),  Route carried "under" structure: US 101,  Year Built: 1989,  Structure Length: 0. m,  Average Daily Traffic: 52,000 (year 2009),  Truck Traffic: 8%,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: STATE ROUTE 25
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 3.200,  Lanes on structure: 2,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.6m (74.1ft)