Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Edinburg, Texas (TX)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 95Number of bridges
  • 1,345ft / 410mTotal length
  • $8,000Total costs
  • 954,766Total average daily traffic
  • 131,575Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Edinburg
  • No street view available for this location

New bridges in Edinburg, TX - historical statistics
  • New bridges - historical statistics
  • 11940-1949
  • 391970-1979
  • 61980-1989
  • 11990-1999
  • 412000-2009
  • 72010-2019
Reconstructed bridges in Edinburg, TX - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11940-1949
  • 01950-1959
  • 01960-1969
  • 01970-1979
  • 21980-1989
  • 21990-1999
  • 122000-2009
Average Bridge Daily Traffic in Edinburg, TX
Average Bridge Truck Traffic in Edinburg, TX
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 3.6%Excellent
  • 7.1%Very good
  • 50.0%Good
  • 39.3%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 1.8%Excellent
  • 16.1%Very good
  • 64.3%Good
  • 17.9%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 80.4%Good
  • 16.1%Satisfactory
  • 3.6%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 3.7%Very good
  • 48.1%Good
  • 40.7%Satisfactory
  • 7.4%Fair
Find on map >>   Show street view

Structure Number: 211090052801003,  Location: 0.25 MI E OF FM 2061 (Lat: 26.305372,  Lng: -98.190161),  Route carried "on" structure: State highway 107,  Year Built: 1978,  Year Reconstructed: 2008,  Status: Open,  Structure Length: 1.86m (6.10ft),  Average Daily Traffic: 25,010 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 44,950 (year 2030),  Design Load: HS 20,  Features Intersected: DRAIN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.757,  Lanes on structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 29.3m (96.1ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 29.3m (96.1ft),  Out-to-Out Width: 38.4m (126.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 211090180301002,  Location: 0.25 MI E OF FM 2061 (Lat: 26.341081,  Lng: -98.184136),  Route carried "on" structure: State highway 1925,  Year Built: 1978,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 2.47m (8.10ft),  Average Daily Traffic: 18,428 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 29,840 (year 2031),  Design Load: HS 20,  Features Intersected: DRAIN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.044,  Lanes on structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 25.3m (83.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 25.2m (82.7ft),  Out-to-Out Width: 29.9m (98.1ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 211090193901005,  Location: 1.90 MI S OF SH 107 (Lat: 26.278550,  Lng: -98.199572),  Route carried "on" structure: State highway 2061,  Year Built: 1978,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 2.01m (6.59ft),  Average Daily Traffic: 24,582 (year 2019),  Truck Traffic: 3%,  Average Future Daily Traffic: 23,930 (year 2033),  Design Load: HS 20,  Features Intersected: MCALLEN LATERAL DRAIN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.094,  Lanes on structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.8m (65.0ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 1.1m (3.6ft),  Curb-To-Curb Width: 18.7m (61.4ft),  Out-to-Out Width: 22.6m (74.1ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 211090193901008,  Location: 0.7 MI N OF SH 107 (Lat: 26.316150,  Lng: -98.192342),  Route carried "on" structure: State highway 2061,  Year Built: 1990,  Year Reconstructed: 2007,  Status: Open,  Structure Length: 2.29m (7.51ft),  Average Daily Traffic: 14,794 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 33,680 (year 2030),  Design Load: HS 20,  Features Intersected: W MAIN I DRAIN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.849,  Lanes on structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 20.2m (66.3ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 211090346801001,  Location: 0.25 MI N.OF WISCONSIN RD (Lat: 26.275431,  Lng: -98.190964),  Route carried "on" structure: State highway 3362,  Year Built: 2000,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 15,872 (year 2014),  Truck Traffic: 2%,  Average Future Daily Traffic: 18,480 (year 2033),  Design Load: HS 20,  Features Intersected: S.MAIN DRAINAGE DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.283,  Lanes on structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 24.4m (80.1ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.4m (7.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2021
Find on map >>   Show street view

Structure Number: 211090AA0166001,  Location: 3.05 MI N OF FM 1925 (Lat: 26.383197,  Lng: -98.162311),  Route carried "on" structure: County highway ,  Year Built: 1979,  Status: Open,  Structure Length: 2.83m (9.28ft),  Average Daily Traffic: 1,560 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 890 (year 2030),  Features Intersected: N MAIN DRAINAGE DITCH,  Facility Carried by Structure: SEMINARY RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.908,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 211090AA0266001,  Location: 0.70 MI E OF US 281 (Lat: 26.265789,  Lng: -98.147425),  Route carried "on" structure: County highway ,  Year Built: 1989,  Status: Open,  Structure Length: 2.83m (9.28ft),  Average Daily Traffic: 2,080 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,860 (year 2030),  Design Load: H 20,  Features Intersected: PHARR-MCALLEN LATERAL,  Facility Carried by Structure: WISCONSIN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.127,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.2m (30.2ft),  Curb-To-Curb Width: 7.7m (25.3ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 211090AA3534002,  Location: 0.3 MI OF SCHUNIOR RD (Lat: 26.320200,  Lng: -98.216200),  Route carried "on" structure: County highway ,  Year Built: 2019,  Status: Open,  Structure Length: 3.66m (12.01ft),  Average Daily Traffic: 1,000 (year 2010),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,600 (year 2030),  Design Load: HL 93,  Features Intersected: HIDALGO W MAIN DRAIN,  Facility Carried by Structure: 10TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.451,  Lanes on structure: 5,  Owner: County Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 30.5m (100.1ft),  Out-to-Out Width: 36.6m (120.1ft)

Condition: Deck: Excellent,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 211090E00183001,  Location: 0.20 MI N OF SH 107 (Lat: 26.314025,  Lng: -98.225489),  Route carried "on" structure: City street ,  Year Built: 1989,  Status: Open,  Structure Length: 2.80m (9.19ft),  Average Daily Traffic: 4,661 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,420 (year 2029),  Features Intersected: HIDALGO W MAIN DRAIN,  Facility Carried by Structure: DEPOT RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.338,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 211090E00320001,  Location: 0.25 MI E OF FM 2061 (Lat: 26.290975,  Lng: -98.192722),  Route carried "on" structure: City street ,  Year Built: 1975,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 1.59m (5.22ft),  Average Daily Traffic: 16,962 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 15,000 (year 2029),  Features Intersected: N MAIN DRAINAGE DITCH,  Facility Carried by Structure: FREDDY GONZALEZ DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.094,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.0m,  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 22.1m (72.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 211090E00344001,  Location: 0.75 MI N OF SH 107 (Lat: 26.320175,  Lng: -98.216167),  Route carried "on" structure: City street ,  Year Built: 1989,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 1,110 (year 2010),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,340 (year 2029),  Features Intersected: HIDALGO W MAIN DRAIN,  Facility Carried by Structure: HOEHN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.207,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 211090E00365001,  Location: 0.25 MI N OF WISCONSIN (Lat: 26.270436,  Lng: -98.154325),  Route carried "on" structure: City street ,  Year Built: 2010,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 5,241 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,160 (year 2029),  Design Load: HS 20,  Features Intersected: HIDALGO S MAIN DRAIN,  Facility Carried by Structure: N I RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.771,  Lanes on structure: 3,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 20 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020
Find on map >>   Show street view

Structure Number: 211090E00525001,  Location: 0.60 MI N OF SH 107 (Lat: 26.315450,  Lng: -98.200667),  Route carried "on" structure: City street ,  Year Built: 1989,  Status: Open,  Structure Length: 2.80m (9.19ft),  Average Daily Traffic: 5,275 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,140 (year 2029),  Features Intersected: HIDALGO W MAIN DRAIN,  Facility Carried by Structure: MON MACK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.575,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 211090E00657001,  Location: 0.25 MI E OF FM 2061 (Lat: 26.326856,  Lng: -98.186406),  Route carried "on" structure: City street ,  Year Built: 1975,  Status: Open,  Structure Length: 1.74m (5.71ft),  Average Daily Traffic: 5,369 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,740 (year 2029),  Features Intersected: N MAIN DRAINAGE DITCH,  Facility Carried by Structure: MILE 17-1/2 N RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.035,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 211090E00668001,  Location: 0.25 MI E OF FM 2061 (Lat: 26.333953,  Lng: -98.185086),  Route carried "on" structure: City street ,  Year Built: 1975,  Status: Open,  Structure Length: 1.74m (5.71ft),  Average Daily Traffic: 4,186 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 3,420 (year 2029),  Features Intersected: N MAIN DRAINAGE DITCH,  Facility Carried by Structure: ROGERS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.575,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 211090E00695001,  Location: 0.25 MI E OF FM 2061 (Lat: 26.319617,  Lng: -98.187739),  Route carried "on" structure: City street ,  Year Built: 1975,  Status: Posted for load,  Structure Length: 1.74m (5.71ft),  Average Daily Traffic: 7,028 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 6,510 (year 2029),  Features Intersected: N MAIN DRAINAGE DITCH,  Facility Carried by Structure: SCHUNIOR RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.426,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 8.1m (26.6ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Fair,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Length Of Structure Improvement: 1.74m (5.71ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $3,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $4,000,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 211090E00695002,  Location: 0.35 MI W OF DEPOT RD (Lat: 26.316772,  Lng: -98.219119),  Route carried "on" structure: City street ,  Year Built: 1989,  Status: Open,  Structure Length: 2.80m (9.19ft),  Average Daily Traffic: 1,543 (year 2019),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,510 (year 2029),  Features Intersected: HIDALGO W MAIN DRAIN,  Facility Carried by Structure: SCHUNIOR RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.448,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 211090E00785001,  Location: 0.25 MI E OF FM 2061 (Lat: 26.298069,  Lng: -98.191469),  Route carried "on" structure: City street ,  Year Built: 1975,  Status: Open,  Structure Length: 1.59m (5.22ft),  Average Daily Traffic: 6,087 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 8,040 (year 2036),  Features Intersected: N MAIN DRAINAGE DITCH,  Facility Carried by Structure: SPRAGUE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.621,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.59m (5.22ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $3,000,  Roadway Improvement Cost: $1,000,  Total Project Cost: $4,000,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 211090E00805001,  Location: 0.25 MI N OF WISCONSIN RD (Lat: 26.274306,  Lng: -98.182872),  Route carried "on" structure: City street ,  Year Built: 1986,  Year Reconstructed: 1996,  Status: Open,  Structure Length: 2.83m (9.28ft),  Average Daily Traffic: 12,010 (year 2016),  Truck Traffic: 2%,  Average Future Daily Traffic: 12,460 (year 2036),  Design Load: H 15,  Features Intersected: S MAIN DRAINAGE DITCH,  Facility Carried by Structure: SOUTH SUGAR ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.679,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.5m (50.9ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 15.6m (51.2ft),  Out-to-Out Width: 20.2m (66.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 211090LH3636001,  Location: 0.25 Ml E OF FM 2061 (Lat: 26.319592,  Lng: -98.187794),  Route carried "on" structure: County highway ,  Year Built: 2019,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 11,780 (year 2010),  Truck Traffic: 2%,  Average Future Daily Traffic: 12,200 (year 2029),  Design Load: HL 93,  Features Intersected: N. Main Drainage Ditch,  Facility Carried by Structure: Chapin Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.805,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.8m (65.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 211090025507001,  Location: 0.50 MI N OF SH 107 (Lat: 26.306461,  Lng: -98.146147),  Route carried "under" structure: State highway 2128,  Year Built: 2007,  Structure Length: 0. m,  Average Daily Traffic: 13,030 (year 2013),  Truck Traffic: 3%,  Features Intersected: FM 2128,  Facility Carried by Structure: US 281 SB OFF RAMP
Minimum Vertical Clearance: 6.20m (20.34ft),  Kilometerpoint: 1.530,  Lanes on structure: 1,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.6m (129.9ft)

Find on map >>   Show street view

Structure Number: 211090025507043,  Location: 0.75 MI N OF SH 107 (Lat: 26.310436,  Lng: -98.146403),  Year Built: 1978,  Structure Length: 0. m,  Features Intersected: UPRR (ABANDONED)
Minimum Vertical Clearance: 6.99m (22.93ft),  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 211090025507044,  Location: 0.75 MI N OF SH 107 (Lat: 26.309861,  Lng: -98.146011),  Year Built: 1978,  Structure Length: 0. m,  Features Intersected: UPRR (ABANDONED)
Minimum Vertical Clearance: 6.91m (22.67ft),  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.3m (69.9ft)

Find on map >>   Show street view

Structure Number: 211090025507045,  Location: 0.6 MI N OF FM 1925 (Lat: 26.344181,  Lng: -98.148111),  Route carried "under" structure: Business State highway 281,  Year Built: 1978,  Structure Length: 0. m,  Average Daily Traffic: 3,100 (year 2011),  Truck Traffic: 3%,  Features Intersected: BU 281 NB
Minimum Vertical Clearance: 5.82m (19.09ft),  Kilometerpoint: 1.775,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 29.9m (98.1ft)

Find on map >>   Show street view

Structure Number: 211090025507046,  Location: 0.6 MI N OF FM 1925 (Lat: 26.343703,  Lng: -98.147544),  Route carried "under" structure: Business State highway 281,  Year Built: 1978,  Structure Length: 0. m,  Average Daily Traffic: 3,100 (year 2011),  Truck Traffic: 3%,  Features Intersected: BU 281 NB
Minimum Vertical Clearance: 5.31m (17.42ft),  Kilometerpoint: 1.823,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.1m (102.0ft)

Find on map >>   Show street view

Structure Number: 211090025507047,  Location: 2.50 MI N OF SH 107 (Lat: 26.335744,  Lng: -98.145403),  Route carried "under" structure: State highway 1925,  Year Built: 1978,  Structure Length: 0. m,  Average Daily Traffic: 15,000 (year 2013),  Truck Traffic: 3%,  Features Intersected: FM 1925 MONTE CRISTO RD,  Facility Carried by Structure: US 281 SB
Minimum Vertical Clearance: 5.01m (16.44ft),  Kilometerpoint: 1.099,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 211090025507048,  Location: 2.50 MI N OF SH 107 (Lat: 26.335217,  Lng: -98.145000),  Route carried "under" structure: State highway 1925,  Year Built: 1978,  Structure Length: 0. m,  Average Daily Traffic: 15,000 (year 2013),  Truck Traffic: 3%,  Features Intersected: FM 1925 MONTE CRISTO RD,  Facility Carried by Structure: US 281 NB
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 1.099,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 211090025507049,  Location: 1.00 MI N OF SH 107 (Lat: 26.313644,  Lng: -98.146658),  Route carried "under" structure: City street ,  Year Built: 1978,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 2013),  Truck Traffic: 2%,  Features Intersected: CHAPIN ST,  Facility Carried by Structure: US 281 SB
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 21109002550705,  Location: 1.00 MI N OF SH 107 (Lat: 26.313650,  Lng: -98.146544),  Route carried "under" structure: City street ,  Year Built: 1978,  Structure Length: 0. m,  Average Daily Traffic: 1,000 (year 2012),  Truck Traffic: 2%,  Features Intersected: CHAPIN ST,  Facility Carried by Structure: US 281 NB
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 27.4m (89.9ft)

Find on map >>   Show street view

Structure Number: 211090025507053,  Location: 6.9 MI N OF US 83 (Lat: 26.299581,  Lng: -98.147092),  Route carried "under" structure: State highway 107,  Year Built: 1978,  Structure Length: 0. m,  Average Daily Traffic: 11,560 (year 2013),  Truck Traffic: 3%,  Features Intersected: SH 107,  Facility Carried by Structure: US 281 SB
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 33.502,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.5m (100.1ft)

Find on map >>   Show street view

Structure Number: 211090025507054,  Location: 6.9 MI N OF US 83 (Lat: 26.299075,  Lng: -98.146786),  Route carried "under" structure: State highway 107,  Year Built: 1978,  Structure Length: 0. m,  Average Daily Traffic: 11,560 (year 2013),  Truck Traffic: 3%,  Features Intersected: SH 107,  Facility Carried by Structure: US 281 NB
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 33.486,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.5m (100.1ft)

Find on map >>   Show street view

Structure Number: 211090025507055,  Location: 1.50 MI N OF SH 107 (Lat: 26.321228,  Lng: -98.148019),  Route carried "under" structure: US 281,  Year Built: 1978,  Structure Length: 0. m,  Average Daily Traffic: 37,550 (year 2011),  Truck Traffic: 24%,  Features Intersected: US 281,  Facility Carried by Structure: RUSSELL RD
Minimum Vertical Clearance: 5.54m (18.18ft),  Kilometerpoint: 52.099,  Lanes on structure: 2,  Lanes under structure: 11,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.5m (100.1ft)

Find on map >>   Show street view

Structure Number: 211090025507093,  Location: 0.50 MI N OF SH 107 (Lat: 26.306444,  Lng: -98.146033),  Route carried "under" structure: State highway 2128,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 13,030 (year 2013),  Truck Traffic: 3%,  Features Intersected: FM 2128 (SCHUNIOR ST),  Facility Carried by Structure: US 281 SB
Minimum Vertical Clearance: 5.49m (18.01ft),  Kilometerpoint: 1.550,  Lanes on structure: 3,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 211090025507094,  Location: 0.50 MI N. OF SH 107 (Lat: 26.305719,  Lng: -98.145742),  Route carried "under" structure: State highway 2128,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 15,360 (year 2013),  Truck Traffic: 2%,  Features Intersected: FM 2128 (SCHUNIOR ST),  Facility Carried by Structure: US 281 NB
Minimum Vertical Clearance: 6.04m (19.82ft),  Kilometerpoint: 1.568,  Lanes on structure: 3,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.4m (116.1ft)

Find on map >>   Show street view

Structure Number: 211090025507095,  Location: 2.1 MI S OF FM 162 (Lat: 26.385031,  Lng: -98.142236),  Route carried "under" structure: State highway 2812,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 9,610 (year 2013),  Truck Traffic: 7%,  Features Intersected: FM 2812,  Facility Carried by Structure: US 281 NB
Minimum Vertical Clearance: 5.44m (17.85ft),  Kilometerpoint: 0.113,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.1m (111.9ft)

Find on map >>   Show street view

Structure Number: 211090025507096,  Location: 2.1 MI S OF FM 162 (Lat: 26.385589,  Lng: -98.142475),  Route carried "under" structure: State highway 2812,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 9,610 (year 2013),  Truck Traffic: 7%,  Features Intersected: FM 2812,  Facility Carried by Structure: US 281 SB
Minimum Vertical Clearance: 5.44m (17.85ft),  Kilometerpoint: 0.137,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.1m (111.9ft)

Find on map >>   Show street view

Structure Number: 211090025507253,  Location: 2.4 MI S OF FM 490 (Lat: 26.416242,  Lng: -98.137331),  Route carried "under" structure: State highway 162,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 3,320 (year 2013),  Truck Traffic: 6%,  Features Intersected: FM 162,  Facility Carried by Structure: US 281 NB
Minimum Vertical Clearance: 5.21m (17.09ft),  Kilometerpoint: 0.296,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.1m (111.9ft)

Find on map >>   Show street view

Structure Number: 211090025507254,  Location: 2.4 MI S OF FM 490 (Lat: 26.416814,  Lng: -26.416814),  Route carried "under" structure: State highway 162,  Year Built: 2003,  Structure Length: 0. m,  Average Daily Traffic: 3,320 (year 2013),  Truck Traffic: 6%,  Features Intersected: FM 162,  Facility Carried by Structure: US 281 SB
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 0.314,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.1m (111.9ft)

Find on map >>   Show street view

Structure Number: 211090025507255,  Location: 4.58 MI N OF FM 2812 (Lat: 26.450458,  Lng: -98.133306),  Route carried "under" structure: State highway 490,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 1,300 (year 2013),  Truck Traffic: 11%,  Features Intersected: FM 490,  Facility Carried by Structure: US 281 NB
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.050,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Find on map >>   Show street view

Structure Number: 211090025507256,  Location: 4.58 MI N OF FM 2812 (Lat: 26.451264,  Lng: -98.133706),  Route carried "under" structure: State highway 490,  Year Built: 2004,  Structure Length: 0. m,  Average Daily Traffic: 1,300 (year 2013),  Truck Traffic: 11%,  Features Intersected: FM 490,  Facility Carried by Structure: US 281 SB
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 0.027,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Find on map >>   Show street view

Structure Number: 211090025507263,  Location: 4.6 MI N OF SH 107 (Lat: 26.365528,  Lng: -98.145211),  Route carried "under" structure: City street ,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 750 (year 2011),  Truck Traffic: 2%,  Features Intersected: RAMSEYER RD,  Facility Carried by Structure: US 281 NB
Minimum Vertical Clearance: 6.45m (21.16ft),  Kilometerpoint: 0.002,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.1m (111.9ft)

Find on map >>   Show street view

Structure Number: 211090025507264,  Location: 4.6 MI N OF SH 107 (Lat: 26.366200,  Lng: -98.145481),  Route carried "under" structure: City street ,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 750 (year 2011),  Truck Traffic: 2%,  Features Intersected: RAMSEYER RD,  Facility Carried by Structure: US 281 SB
Minimum Vertical Clearance: 6.02m (19.75ft),  Kilometerpoint: 0.002,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 34.1m (111.9ft)

Find on map >>   Show street view

Structure Number: 211090025508058,  Location: 0.50 MI S OF SH 107 (Lat: 26.291744,  Lng: -98.148053),  Route carried "under" structure: City street ,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 400 (year 2011),  Truck Traffic: 2%,  Features Intersected: SPRAGUE ST,  Facility Carried by Structure: US 281 NB
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.9m (85.0ft)

Find on map >>   Show street view

Structure Number: 211090025508059,  Location: 0.50 MI S OF SH 107 (Lat: 26.292231,  Lng: -98.148311),  Route carried "under" structure: City street ,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 400 (year 2011),  Truck Traffic: 2%,  Features Intersected: SPRAGUE ST,  Facility Carried by Structure: US 281 SB
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.9m (85.0ft)

Find on map >>   Show street view

Structure Number: 21109002550806,  Location: 1.00 MI S OF SH 107 (Lat: 26.284308,  Lng: -98.149322),  Route carried "under" structure: City street ,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 400 (year 2011),  Truck Traffic: 2%,  Features Intersected: FREDDY GONZALEZ DR,  Facility Carried by Structure: US 281 NB
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.9m (85.0ft)

Find on map >>   Show street view

Structure Number: 211090025508061,  Location: 1.00 MI S OF SH 107 (Lat: 26.284908,  Lng: -98.149581),  Route carried "under" structure: City street ,  Year Built: 1979,  Structure Length: 0. m,  Average Daily Traffic: 400 (year 2011),  Truck Traffic: 2%,  Features Intersected: FREDDY GONZALEZ DR,  Facility Carried by Structure: US 281 SB
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.9m (85.0ft)

Find on map >>   Show street view

Structure Number: 211090025508261,  Location: 2.95 MI S OF SH 107 (Lat: 26.260550,  Lng: -98.164322),  Route carried "under" structure: City street ,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 500 (year 2009),  Truck Traffic: 2%,  Features Intersected: TRENTON RD,  Facility Carried by Structure: US 281 NB
Minimum Vertical Clearance: 5.08m (16.67ft),  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.6m (129.9ft)

Find on map >>   Show street view

Structure Number: 211090025508262,  Location: 2.95 MI S OF SH 107 (Lat: 26.261167,  Lng: -98.164292),  Route carried "under" structure: City street ,  Year Built: 2005,  Structure Length: 0. m,  Average Daily Traffic: 500 (year 2009),  Truck Traffic: 2%,  Features Intersected: TRENTON RD,  Facility Carried by Structure: US 281 SB
Minimum Vertical Clearance: 5.18m (16.99ft),  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 39.6m (129.9ft)

Find on map >>   Show street view

Structure Number: 211090025508265,  Location: 1.75 MI S OF SH 107 (Lat: 26.273639,  Lng: -98.152536),  Route carried "under" structure: County highway ,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 14,550 (year 2011),  Truck Traffic: 1%,  Features Intersected: CANTON ROAD,  Facility Carried by Structure: US 281 NB
Minimum Vertical Clearance: 6.40m (21.00ft),  Lanes on structure: 4,  Lanes under structure: 9,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.2m (122.0ft)

Find on map >>   Show street view

Structure Number: 211090025508266,  Location: 1.75 MI S OF SH 107 (Lat: 26.274125,  Lng: -98.152708),  Route carried "under" structure: County highway ,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 14,550 (year 2011),  Truck Traffic: 1%,  Features Intersected: CANTON ROAD,  Facility Carried by Structure: US 281 SB
Minimum Vertical Clearance: 5.41m (17.75ft),  Lanes on structure: 4,  Lanes under structure: 9,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.2m (122.0ft)

Find on map >>   Show street view

Structure Number: 211090025508267,  Location: 1.9 MI S OF SH 107 (Lat: 26.271758,  Lng: -98.154228),  Route carried "under" structure: County highway ,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 3,560 (year 2011),  Truck Traffic: 1%,  Features Intersected: I ROAD,  Facility Carried by Structure: US 281 NB
Minimum Vertical Clearance: 5.59m (18.34ft),  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.4m (126.0ft)

Find on map >>   Show street view

Structure Number: 211090025508268,  Location: 1.90 MI S OF SH 107 (Lat: 26.272806,  Lng: -98.153806),  Route carried "under" structure: County highway ,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 3,560 (year 2011),  Truck Traffic: 1%,  Features Intersected: I ROAD,  Facility Carried by Structure: US 281 SB
Minimum Vertical Clearance: 5.77m (18.93ft),  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 38.4m (126.0ft)

Find on map >>   Show street view

Structure Number: 21109002550827,  Location: 1.1 MI N OF FM 3461 (Lat: 26.251300,  Lng: -98.174372),  Route carried "under" structure: State highway 281,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 37,550 (year 2010),  Truck Traffic: 8%,  Features Intersected: US 281 & OWASSA RD
Minimum Vertical Clearance: 6.38m (20.93ft),  Kilometerpoint: 7.937,  Lanes on structure: 1,  Lanes under structure: 18,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 52.4m (171.9ft)

Find on map >>   Show street view

Structure Number: 211090025508272,  Location: 1.0 MI N OF FM 3461 (Lat: 26.247964,  Lng: -98.175381),  Route carried "under" structure: County highway ,  Year Built: 2006,  Structure Length: 0. m,  Average Daily Traffic: 7,240 (year 2009),  Truck Traffic: 1%,  Features Intersected: OWASSA ROAD,  Facility Carried by Structure: US 281 SB
Minimum Vertical Clearance: 6.40m (21.00ft),  Lanes on structure: 4,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Discuss Edinburg, Texas (TX) on our hugely popular Texas forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.