Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Dundee, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 51Number of bridges
  • 410ft / 125mTotal length
  • $445,000Total costs
  • 404,056Total average daily traffic
  • 62,759Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Dundee
  • No street view available for this location

New bridges in Dundee, MI - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 11920-1929
  • 21930-1939
  • 21940-1949
  • 161950-1959
  • 131960-1969
  • 31970-1979
  • 11980-1989
  • 71990-1999
  • 22000-2009
  • 22010-2019
  • 12020-2022
Reconstructed bridges in Dundee, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11970-1979
  • 11980-1989
  • 81990-1999
  • 12000-2009
  • 22010-2019
Average Bridge Daily Traffic in Dundee, MI
Average Bridge Truck Traffic in Dundee, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 7.1%Excellent
  • 7.1%Very good
  • 19.0%Good
  • 35.7%Satisfactory
  • 23.8%Fair
  • 4.8%Poor
  • 2.4%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 7.1%Excellent
  • 2.4%Very good
  • 19.0%Good
  • 26.2%Satisfactory
  • 35.7%Fair
  • 7.1%Poor
  • 2.4%Imminent failure
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 2.4%Excellent
  • 9.5%Very good
  • 19.0%Good
  • 45.2%Satisfactory
  • 21.4%Fair
  • 2.4%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 2.6%Very good
  • 15.8%Good
  • 36.8%Satisfactory
  • 26.3%Fair
  • 15.8%Poor
  • 2.6%Serious
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 66.7%Good
  • 33.3%Fair
Find on map >>   Show street view

Structure Number: 707,  Location: 1000 FT S OF TOWNLINE RD (Lat: 43.822464,  Lng: -83.986547),  Route carried "on" structure: County highway ,  Year Built: 2021,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 409 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 499 (year 2040),  Design Load: Greater than HL93,  Features Intersected: JOHNSON DRAIN,  Facility Carried by Structure: MACKINAW ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 33.276,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.3m (43.6ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Channel: Very good,  Operating Rating: 78.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 60.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.30m (4.27ft),  Designated Inspection Frequency: Every 9 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $225,000,  Roadway Improvement Cost: $70,000,  Total Project Cost: $325,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 707,  Location: IN DUNDEE MONROE ST (Lat: 41.956272,  Lng: -83.658481),  Route carried "on" structure: State highway 50,  Year Built: 1937,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 6.15m (20.18ft),  Average Daily Traffic: 9,360 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 13,555 (year 2018),  Design Load: H 20,  Features Intersected: RIVER RAISIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.578,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 122,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.9m (81.7ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 18.1m (59.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 53.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 7073,  Location: 1.5 MI N OF M-50 (Lat: 41.980469,  Lng: -83.678267),  Route carried "on" structure: US 23,  Year Built: 1961,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 16,735 (year 2007),  Truck Traffic: 17%,  Average Future Daily Traffic: 20,019 (year 2018),  Design Load: HS 20,  Features Intersected: S BR MACON RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 29.298,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 122,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 12 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 73.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7074,  Location: 1.5 MI N OF M-50 (Lat: 41.980378,  Lng: -83.678608),  Route carried "on" structure: US 23,  Year Built: 1961,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 16,735 (year 2007),  Truck Traffic: 17%,  Average Future Daily Traffic: 20,019 (year 2018),  Design Load: HS 20,  Features Intersected: S BR MACON RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 29.364,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 122,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 12 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 73.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7075,  Location: 1.7 MI N OF M-50 (Lat: 41.983106,  Lng: -83.678314),  Route carried "on" structure: US 23,  Year Built: 1961,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 3.53m (11.58ft),  Average Daily Traffic: 16,735 (year 2007),  Truck Traffic: 17%,  Average Future Daily Traffic: 20,019 (year 2018),  Design Load: HS 20,  Features Intersected: MIDDLE BR MACON RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 29.590,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 122,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 12 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.8m (38.7ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Inventory Rating: 94.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7076,  Location: 1.7 MI N OF M-50 (Lat: 41.983014,  Lng: -83.678669),  Route carried "on" structure: US 23,  Year Built: 1961,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 3.53m (11.58ft),  Average Daily Traffic: 16,735 (year 2007),  Truck Traffic: 17%,  Average Future Daily Traffic: 20,019 (year 2018),  Design Load: HS 20,  Features Intersected: MIDDLE BR MACON RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 29.656,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 122,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 12 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.8m (38.7ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Inventory Rating: 94.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7077,  Location: 3.5 MI N OF M-50 (Lat: 42.015083,  Lng: -83.678292),  Route carried "on" structure: US 23,  Year Built: 1961,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 16,735 (year 2007),  Truck Traffic: 17%,  Average Future Daily Traffic: 20,019 (year 2018),  Design Load: HS 20,  Features Intersected: BEAR CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 33.144,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 122,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 12 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 60.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 7078,  Location: 3.8 MI N OF M-50 (Lat: 42.015197,  Lng: -83.678647),  Route carried "on" structure: US 23,  Year Built: 1961,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 16,735 (year 2007),  Truck Traffic: 17%,  Average Future Daily Traffic: 20,019 (year 2018),  Design Load: HS 20,  Features Intersected: BEAR CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 33.233,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 122,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 12 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 62.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 7079,  Location: 4.7 MI N OF M-50 (Lat: 42.025508,  Lng: -83.678636),  Route carried "on" structure: US 23,  Year Built: 1961,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 16,735 (year 2007),  Truck Traffic: 17%,  Average Future Daily Traffic: 20,019 (year 2018),  Design Load: HS 20,  Features Intersected: N BR MACON RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 34.301,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 122,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 12 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Fair,  Operating Rating: 60.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 708,  Location: 4.7 MI N OF M-50 (Lat: 42.025631,  Lng: -83.679000),  Route carried "on" structure: US 23,  Year Built: 1961,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 16,735 (year 2007),  Truck Traffic: 17%,  Average Future Daily Traffic: 20,019 (year 2018),  Design Load: HS 20,  Features Intersected: N BR MACON RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 34.391,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 122,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 12 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 87.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 52.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 7083,  Location: 3.7 MI N OF M-50 (Lat: 42.011561,  Lng: -83.678167),  Route carried "on" structure: County highway ,  Year Built: 1961,  Status: Closed,  Structure Length: 6.36m (20.87ft),  Average Daily Traffic: 290 (year 1974),  Truck Traffic: 3%,  Average Future Daily Traffic: 290 (year 1977),  Design Load: H 15,  Features Intersected: US-23,  Facility Carried by Structure: MILWAUKEE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.764,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 21.6m (70.9ft),  Curb-To-Curb Width: 9.0m (29.5ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 53.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 28.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 7093,  Location: 1.0 MI S OF M-50 (Lat: 41.945622,  Lng: -83.665719),  Route carried "on" structure: US 23,  Year Built: 1958,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 7.62m (25.00ft),  Average Daily Traffic: 17,262 (year 2007),  Truck Traffic: 17%,  Average Future Daily Traffic: 19,397 (year 2018),  Design Load: HS 20,  Features Intersected: RIVER RAISIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 25.276,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 122,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 12 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 30.4m (99.7ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 75.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7101,  Location: 3.0 MI S OF DUNDEE (Lat: 41.914314,  Lng: -83.661897),  Route carried "on" structure: US 23,  Year Built: 1958,  Status: Open,  Structure Length: 5.67m (18.60ft),  Average Daily Traffic: 16,733 (year 2007),  Truck Traffic: 16%,  Average Future Daily Traffic: 19,701 (year 2018),  Design Load: HS 20,  Features Intersected: INDIANA & OHIO RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 21.690,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 122,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 14 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.9m (62.0ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Fair,  Operating Rating: 65.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 7102,  Location: 3.0 MI S OF DUNDEE (Lat: 41.914139,  Lng: -83.662156),  Route carried "on" structure: US 23,  Year Built: 1958,  Status: Open,  Structure Length: 5.67m (18.60ft),  Average Daily Traffic: 16,733 (year 2007),  Truck Traffic: 16%,  Average Future Daily Traffic: 19,701 (year 2018),  Design Load: HS 20,  Features Intersected: INDIANA & OHIO RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 21.741,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 122,  Subroute: 4),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 14 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.9m (62.0ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 95.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 49.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 7109,  Location: 3.5 MI S OF M-50 (Lat: 41.909942,  Lng: -83.661786),  Route carried "on" structure: County highway 5850,  Year Built: 1958,  Status: Open,  Structure Length: 6.15m (20.18ft),  Average Daily Traffic: 2,070 (year 1974),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,070 (year 1977),  Design Load: H 15,  Features Intersected: US-23,  Facility Carried by Structure: IDA WEST RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.815,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 122,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.9m (58.7ft),  Curb-To-Curb Width: 9.7m (31.8ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Satisfactory,  Operating Rating: 50.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 711,  Location: 2.2 MI S OF M-50 (Lat: 41.930053,  Lng: -83.662264),  Route carried "on" structure: County highway ,  Year Built: 1959,  Status: Open,  Structure Length: 8.23m (27.00ft),  Average Daily Traffic: 980 (year 1974),  Average Future Daily Traffic: 980 (year 1977),  Design Load: H 15,  Features Intersected: US-23,  Facility Carried by Structure: DIXON RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.449,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.0m (78.7ft),  Curb-To-Curb Width: 9.7m (31.8ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 51.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 7111,  Location: 0.7 MI S OF M-50 (Lat: 41.950242,  Lng: -83.668600),  Route carried "on" structure: City street ,  Year Built: 1959,  Status: Open,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 250 (year 1974),  Truck Traffic: 3%,  Average Future Daily Traffic: 250 (year 1977),  Design Load: H 15,  Features Intersected: US-23,  Facility Carried by Structure: BREWER RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.609,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 9.7m (31.8ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 49.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 26.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 7112,  Location: IN DUNDEE (Lat: 41.959356,  Lng: -83.672381),  Route carried "on" structure: US 23,  Year Built: 1958,  Status: Open,  Structure Length: 6.00m (19.69ft),  Average Daily Traffic: 34,524 (year 2007),  Truck Traffic: 17%,  Average Future Daily Traffic: 40,038 (year 2018),  Design Load: HS 20,  Features Intersected: M-50
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 26.853,  Lanes on structure: 4,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 122,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 31 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.7m (81.0ft),  Curb-To-Curb Width: 29.0m (95.1ft),  Out-to-Out Width: 30.3m (99.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 7113,  Location: 2.5 MI W OF DUNDEE (Lat: 41.965411,  Lng: -83.707050),  Route carried "on" structure: State highway 50,  Year Built: 1953,  Status: Open,  Structure Length: 1.67m (5.48ft),  Average Daily Traffic: 6,646 (year 2007),  Truck Traffic: 6%,  Average Future Daily Traffic: 12,805 (year 2018),  Design Load: HS 20,  Features Intersected: S BR MACON RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.446,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 122,  Subroute: 3),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.7m (54.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.68m (5.51ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $30,000,  Roadway Improvement Cost: $4,000,  Total Project Cost: $50,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 7232,  Location: .2 MI SO OF M 50 (Lat: 41.961250,  Lng: -83.711844),  Route carried "on" structure: County highway 5815,  Year Built: 1958,  Year Reconstructed: 2019,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 500 (year 2016),  Truck Traffic: 17%,  Average Future Daily Traffic: 575 (year 2036),  Design Load: HL 93,  Features Intersected: SO BR MACON DR,  Facility Carried by Structure: PETERSBURG RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.404,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.3m (33.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 82.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 63.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7233,  Location: 1.25 MI S OF M-50 (Lat: 41.947167,  Lng: -83.711547),  Route carried "on" structure: County highway 5815,  Year Built: 1956,  Year Reconstructed: 2019,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 500 (year 2016),  Truck Traffic: 17%,  Average Future Daily Traffic: 575 (year 2036),  Design Load: HL 93,  Features Intersected: SWAMP RAISIN DRAIN,  Facility Carried by Structure: PETERSBURG RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.839,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.6m (34.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 59.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Membrane: Epoxy,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7234,  Location: 1.75 MI S OF M-50 (Lat: 41.942281,  Lng: -83.711394),  Route carried "on" structure: County highway 5815,  Year Built: 1978,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 689 (year 2011),  Truck Traffic: 3%,  Average Future Daily Traffic: 870 (year 2031),  Design Load: HS 20,  Features Intersected: LITTLE RAISIN RIVER,  Facility Carried by Structure: PETERSBURG ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.297,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 57.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other
Find on map >>   Show street view

Structure Number: 7245,  Location: 2.75 MI E OF COUNTY LINE (Lat: 41.945356,  Lng: -83.718947),  Route carried "on" structure: County highway ,  Year Built: 2009,  Status: Open,  Structure Length: 2.10m (6.89ft),  Average Daily Traffic: 260 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 299 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: SWAMP RAISIN CREEK,  Facility Carried by Structure: BREWER RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.276,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 20.5m (67.3ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 94.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 56.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7246,  Location: 3.55 MI E OF COUNTY LINE (Lat: 41.945700,  Lng: -83.704519),  Route carried "on" structure: County highway ,  Year Built: 1967,  Status: Open,  Structure Length: 1.33m (4.36ft),  Average Daily Traffic: 670 (year 2015),  Truck Traffic: 1%,  Average Future Daily Traffic: 771 (year 2035),  Features Intersected: SWAMP RAISIN DRAIN,  Facility Carried by Structure: BREWER RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.472,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.0m (39.4ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 77.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 7247,  Location: 1.85 MI N OF DUNDEE (Lat: 41.978989,  Lng: -83.627492),  Route carried "on" structure: County highway 5866,  Year Built: 1964,  Status: Open,  Structure Length: 3.65m (11.98ft),  Average Daily Traffic: 1,300 (year 2017),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,495 (year 2037),  Design Load: H 20,  Features Intersected: MACON RIVER,  Facility Carried by Structure: STOWELL RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.111,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.8m (38.7ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Poor,  Operating Rating: 50.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: High priority of corrective action,  Length Of Structure Improvement: 3.66m (12.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Bridge Improvement Cost: $60,000,  Total Project Cost: $70,000,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 7249,  Location: 1.25 MI N OF M 50 (Lat: 41.986667,  Lng: -83.731919),  Route carried "on" structure: County highway 5809,  Year Built: 2011,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 430 (year 2015),  Truck Traffic: 14%,  Average Future Daily Traffic: 495 (year 2035),  Design Load: HL 93,  Features Intersected: N DR MID BR MACON R,  Facility Carried by Structure: DENNISON RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.662,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.5m (60.7ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 70.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 725,  Location: .3 MI NO OF M 50 (Lat: 41.974256,  Lng: -83.731494),  Route carried "on" structure: County highway 5809,  Year Built: 2017,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 484 (year 2017),  Truck Traffic: 8%,  Average Future Daily Traffic: 875 (year 2037),  Design Load: Greater than HL93,  Features Intersected: MIDDLE BRANCH MACON DRAI,  Facility Carried by Structure: DENNISON RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.284,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 77.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 7256,  Location: 0.2 MI N OF OSTRANDER RD (Lat: 42.022539,  Lng: -83.674222),  Route carried "on" structure: County highway 5817,  Year Built: 1947,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 2,378 (year 2017),  Truck Traffic: 15%,  Average Future Daily Traffic: 2,735 (year 2037),  Design Load: HS 20,  Features Intersected: NORTH MACON CREEK,  Facility Carried by Structure: ANN ARBOR ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.099,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.1m (43.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 87.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7257,  Location: 3.95 MI N OF M 50 (Lat: 42.014086,  Lng: -83.673958),  Route carried "on" structure: County highway 5817,  Year Built: 1947,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 2,766 (year 2017),  Truck Traffic: 15%,  Average Future Daily Traffic: 3,181 (year 2037),  Design Load: HS 20,  Features Intersected: BEAR SWAMP CREEK,  Facility Carried by Structure: ANN ARBOR ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.161,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.0m (32.8ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 86.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 728,  Location: .35 MI E OF ANN ARBOR RD (Lat: 42.019011,  Lng: -83.667256),  Route carried "on" structure: County highway 5878,  Year Built: 1950,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 926 (year 2017),  Truck Traffic: 11%,  Average Future Daily Traffic: 1,533 (year 2037),  Design Load: H 15,  Features Intersected: MACON DRAIN,  Facility Carried by Structure: OSTRANDER RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.888,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 79.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 47.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 7301,  Location: 0.5 MI E OF ANN ARBOR RD (Lat: 41.997275,  Lng: -83.662933),  Route carried "on" structure: County highway ,  Year Built: 1960,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 855 (year 2005),  Truck Traffic: 37%,  Average Future Daily Traffic: 983 (year 2025),  Features Intersected: MACON DRAIN,  Facility Carried by Structure: DAY ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.260,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.4m (21.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 26.8m (87.9ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 7319,  Location: 0.2 MI S OF BREWER ROAD (Lat: 41.944958,  Lng: -83.682464),  Route carried "on" structure: County highway ,  Year Built: 1979,  Status: Open,  Structure Length: 1.49m (4.89ft),  Average Daily Traffic: 171 (year 2003),  Truck Traffic: 4%,  Average Future Daily Traffic: 240 (year 2023),  Design Load: HS 20,  Features Intersected: LITTLE RIVER RAISIN,  Facility Carried by Structure: DAVIS ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.857,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 70.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other
Find on map >>   Show street view

Structure Number: 732,  Location: 0.7 MI E OF DENNISON ROAD (Lat: 41.981900,  Lng: -83.717442),  Route carried "on" structure: County highway ,  Year Built: 1897,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 21 (year 2004),  Truck Traffic: 3%,  Average Future Daily Traffic: 60 (year 2021),  Design Load: HS 20,  Features Intersected: NORTH MACON DRAIN,  Facility Carried by Structure: COLLINS ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.188,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb-To-Curb Width: 7.5m (24.6ft),  Out-to-Out Width: 7.5m (24.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 77.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 7325,  Location: 0.4 MI S OF DAY ROAD (Lat: 41.989544,  Lng: -83.741706),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 1.57m (5.15ft),  Average Daily Traffic: 50 (year 2005),  Truck Traffic: 4%,  Average Future Daily Traffic: 57 (year 2025),  Design Load: HS 20,  Features Intersected: NORTH MACON DRAIN,  Facility Carried by Structure: HISER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.025,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Skew: 1 degrees,  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 6.9m (22.6ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.7m (25.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 55.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 40.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2022,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 7326,  Location: 0.1 MI N OF M 50 (Lat: 41.972444,  Lng: -83.741125),  Route carried "on" structure: County highway ,  Year Built: 1990,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 54 (year 1990),  Truck Traffic: 3%,  Average Future Daily Traffic: 68 (year 2014),  Design Load: HS 20,  Features Intersected: MIDDLE BRANCH MACON DRAI,  Facility Carried by Structure: HISER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.124,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 733,  Location: 1.1 MILE NORTH OF BREWER (Lat: 41.957950,  Lng: -83.730922),  Route carried "on" structure: County highway ,  Year Built: 1983,  Status: Open,  Structure Length: 2.34m (7.68ft),  Average Daily Traffic: 366 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 550 (year 2026),  Design Load: HS 20,  Features Intersected: SOUTH BRANCH MACON DRAIN,  Facility Carried by Structure: DENNISON RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.472,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 10.6m (34.8ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Fair,  Operating Rating: 59.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other
Find on map >>   Show street view

Structure Number: 7331,  Location: 0.2 MI N OF KENT ROAD (Lat: 41.977839,  Lng: -83.721956),  Route carried "on" structure: County highway ,  Year Built: 1990,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 65 (year 1998),  Truck Traffic: 3%,  Average Future Daily Traffic: 75 (year 2018),  Design Load: HS 20,  Features Intersected: MIDDLE BRANCH MACON DRAI,  Facility Carried by Structure: REA ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.306,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft)

Condition: Channel: Poor,  Culverts: Good,  Operating Rating: 54.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020
Find on map >>   Show street view

Structure Number: 7333,  Location: 0.1 MI N OF KENT ROAD (Lat: 41.979458,  Lng: -83.712322),  Route carried "on" structure: County highway ,  Year Built: 1990,  Status: Open,  Structure Length: 2.01m (6.59ft),  Average Daily Traffic: 40 (year 2016),  Truck Traffic: 3%,  Average Future Daily Traffic: 46 (year 2036),  Design Load: HS 20,  Features Intersected: MIDDLE BRANCH MACON DRAI,  Facility Carried by Structure: PETERSBURG ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 8.425,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 9.7m (31.8ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Poor,  Inventory Rating: 55.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other
Find on map >>   Show street view

Structure Number: 7336,  Location: 1.1 MI N OF M 50 (Lat: 41.977208,  Lng: -83.687567),  Route carried "on" structure: County highway ,  Year Built: 2008,  Status: Open,  Structure Length: 1.87m (6.14ft),  Average Daily Traffic: 460 (year 2006),  Truck Traffic: 12%,  Average Future Daily Traffic: 529 (year 2026),  Design Load: HS 20+Mod,  Features Intersected: SOUTH BRANCH MACON RIVER,  Facility Carried by Structure: WILCOX ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.688,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 59.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Discuss Dundee, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.