Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Brownsville, Texas (TX)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 191Number of bridges
  • 4,993ft / 1,522mTotal length
  • $383,000Total costs
  • 2,373,966Total average daily traffic
  • 195,625Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Brownsville
  • No street view available for this location

New bridges in Brownsville, TX - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 31940-1949
  • 21950-1959
  • 141960-1969
  • 51970-1979
  • 191980-1989
  • 431990-1999
  • 672000-2009
  • 352010-2019
  • 22020-2022
Reconstructed bridges in Brownsville, TX - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 11960-1969
  • 01970-1979
  • 31980-1989
  • 111990-1999
  • 112000-2009
Average Bridge Daily Traffic in Brownsville, TX
Average Bridge Truck Traffic in Brownsville, TX
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 5.0%Very good
  • 81.5%Good
  • 12.6%Satisfactory
  • 0.8%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 33.6%Excellent
  • 57.1%Very good
  • 7.6%Good
  • 1.7%Satisfactory
  • 0.8%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 1.7%Very good
  • 84.9%Good
  • 12.6%Satisfactory
  • 0.8%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 11.4%Very good
  • 29.5%Good
  • 45.5%Satisfactory
  • 11.4%Fair
  • 2.3%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 4.0%Very good
  • 64.0%Good
  • 28.0%Satisfactory
  • 4.0%Fair
Find on map >>   Show street view

Structure Number: 210310003906257,  Location: 2.00 MI E OF FM 800 (Lat: 26.180200,  Lng: -97.751294),  Route carried "on" structure: Business State highway 83,  Year Built: 1997,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 10,700 (year 2017),  Truck Traffic: 6%,  Average Future Daily Traffic: 13,730 (year 2037),  Design Load: HS 20,  Features Intersected: DRAINAGE DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.981,  Lanes on structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 19.8m (65.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 210310003908019,  Location: 2.30 Mi SE of SH 100 (Lat: 26.052892,  Lng: -97.558628),  Route carried "on" structure: US 77,  Year Built: 1924,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 41,850 (year 2011),  Truck Traffic: 9%,  Average Future Daily Traffic: 61,350 (year 2031),  Features Intersected: Jackass Prairie Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 42.735,  Lanes on structure: 11,  Owner: State Highway Agency,  Approaching Roadway Width: 63.1m (207.0ft),  Skew: 22 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 210310003908021,  Location: 1.20 Mi NW of FM 511 (Lat: 26.042656,  Lng: -97.547058),  Route carried "on" structure: US 77,  Year Built: 2007,  Status: Open,  Structure Length: 8.29m (27.20ft),  Average Daily Traffic: 21,780 (year 2011),  Truck Traffic: 9%,  Average Future Daily Traffic: 31,920 (year 2031),  Design Load: HL 93,  Features Intersected: Rancho Viejo Dr
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 43.811,  Lanes on structure: 3,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 34.1m (111.9ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908224,  Location: 1.05 MI NW OF SH 100 (Lat: 26.093989,  Lng: -97.589606),  Route carried "on" structure: US 77,  Year Built: 1983,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 4.57m (14.99ft),  Average Daily Traffic: 25,180 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 35,250 (year 2031),  Design Load: HS 20,  Features Intersected: RUNNELS ST (FR T/A)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 36.682,  Lanes on structure: 3,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 16.7m (54.8ft),  Out-to-Out Width: 17.3m (56.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 210310003908225,  Location: 1.05 MI NW OF SH 100 (Lat: 26.094158,  Lng: -97.590092),  Route carried "on" structure: US 77,  Year Built: 1983,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 4.57m (14.99ft),  Average Daily Traffic: 25,180 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 35,250 (year 2031),  Design Load: HS 20,  Features Intersected: RUNNELS ST (FR T/A)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 36.682,  Lanes on structure: 3,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 16.8m (55.1ft),  Out-to-Out Width: 17.3m (56.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 210310003908226,  Location: 0.90 Mi N of FM 1732 (Lat: 26.029128,  Lng: -97.533356),  Route carried "on" structure: US 77,  Year Built: 1987,  Year Reconstructed: 2007,  Status: Open,  Structure Length: 6.10m (20.01ft),  Average Daily Traffic: 21,780 (year 2011),  Truck Traffic: 9%,  Average Future Daily Traffic: 31,920 (year 2031),  Design Load: HS 20,  Features Intersected: FM 511
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 45.800,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 16.6m (54.5ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 210310003908227,  Location: 0.90 Mi N of FM 1732 (Lat: 26.029142,  Lng: -97.533253),  Route carried "on" structure: US 77,  Year Built: 1987,  Year Reconstructed: 2007,  Status: Open,  Structure Length: 6.10m (20.01ft),  Average Daily Traffic: 21,780 (year 2011),  Truck Traffic: 9%,  Average Future Daily Traffic: 31,920 (year 2031),  Design Load: HS 20,  Features Intersected: FM 511
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 45.800,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 16.6m (54.5ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 210310003908232,  Location: 1.20 MI SE OF SH 100 (Lat: 26.067292,  Lng: -97.570067),  Route carried "on" structure: US 77,  Year Built: 1990,  Year Reconstructed: 2007,  Status: Open,  Structure Length: 4.72m (15.49ft),  Average Daily Traffic: 18,520 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 31,550 (year 2035),  Design Load: HS 20,  Features Intersected: ROBERTA RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 40.226,  Lanes on structure: 3,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 16.6m (54.5ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908233,  Location: 1.20 MI SE OF SH 100 (Lat: 26.067483,  Lng: -97.570547),  Route carried "on" structure: US 77,  Year Built: 1990,  Year Reconstructed: 2007,  Status: Open,  Structure Length: 4.72m (15.49ft),  Average Daily Traffic: 18,520 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 31,550 (year 2035),  Design Load: HS 20,  Features Intersected: ROBERTA RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 40.226,  Lanes on structure: 3,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 16.7m (54.8ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908239,  Location: 0.85 Mi N of FM 3248 (Lat: 25.990469,  Lng: -97.520783),  Route carried "on" structure: US 77,  Year Built: 1991,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 8.69m (28.51ft),  Average Daily Traffic: 30,810 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 55,840 (year 2031),  Design Load: HS 20,  Features Intersected: Old Alice Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 50.482,  Lanes on structure: 3,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 16.6m (54.5ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 21031000390824,  Location: 0.85 Mi N of FM 3248 (Lat: 25.990431,  Lng: -97.520883),  Route carried "on" structure: US 77,  Year Built: 1991,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 8.69m (28.51ft),  Average Daily Traffic: 30,810 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 55,840 (year 2031),  Design Load: HS 20,  Features Intersected: Old Alice Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 50.482,  Lanes on structure: 3,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 16.6m (54.5ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908241,  Location: 0.80 Mi S of FM 1732 (Lat: 26.004422,  Lng: -97.529844),  Route carried "on" structure: US 77,  Year Built: 1991,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 5.33m (17.49ft),  Average Daily Traffic: 30,810 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 55,840 (year 2031),  Design Load: HS 20,  Features Intersected: Merryman Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 48.681,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 16.6m (54.5ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908242,  Location: 0.80 Mi S of FM 1732 (Lat: 26.004422,  Lng: -97.529956),  Route carried "on" structure: US 77,  Year Built: 1991,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 5.33m (17.49ft),  Average Daily Traffic: 30,810 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 55,840 (year 2031),  Design Load: HS 20,  Features Intersected: Merryman Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 48.681,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 16.6m (54.5ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908243,  Location: 0.90 Mi S of FM 511 (Lat: 26.016319,  Lng: -97.530231),  Route carried "on" structure: US 77,  Year Built: 1991,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 6.25m (20.51ft),  Average Daily Traffic: 30,810 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 55,840 (year 2031),  Design Load: HS 20,  Features Intersected: FM 1732 (Anacua St)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.342,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 25.9m (85.0ft),  Curb-To-Curb Width: 16.6m (54.5ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908244,  Location: 0.90 Mi S of FM 511 (Lat: 26.016319,  Lng: -97.530344),  Route carried "on" structure: US 77,  Year Built: 1991,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 6.25m (20.51ft),  Average Daily Traffic: 30,810 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 55,840 (year 2031),  Design Load: HS 20,  Features Intersected: FM 1732 (Anacua St)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.342,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 25.9m (85.0ft),  Curb-To-Curb Width: 16.6m (54.5ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908294,  Location: 1.40 Mi S of FM 1732 (Lat: 25.996944,  Lng: -97.525175),  Route carried "on" structure: US 77,  Year Built: 2000,  Status: Open,  Structure Length: 7.32m (24.02ft),  Average Daily Traffic: 30,810 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 55,840 (year 2031),  Design Load: HS 20,  Features Intersected: UP RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 49.663,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908295,  Location: 1.40 MI S OF FM 1732 (Lat: 25.997050,  Lng: -97.525492),  Route carried "on" structure: US 77,  Year Built: 2000,  Status: Open,  Structure Length: 7.32m (24.02ft),  Average Daily Traffic: 30,810 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 55,840 (year 2031),  Design Load: HS 20,  Features Intersected: UP RR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 49.663,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 27.4m (89.9ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908353,  Location: 1.20 Mi NW of FM 511 (Lat: 26.042578,  Lng: -97.547133),  Route carried "on" structure: US 77,  Year Built: 2007,  Status: Open,  Structure Length: 8.29m (27.20ft),  Average Daily Traffic: 22,300 (year 2015),  Truck Traffic: 9%,  Average Future Daily Traffic: 34,510 (year 2035),  Design Load: HL 93,  Features Intersected: Rancho Viejo Dr
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 45.850,  Lanes on structure: 3,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 34.1m (111.9ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908354,  Location: 2.05 Mi SE of SH 100 (Lat: 26.056197,  Lng: -97.562244),  Route carried "on" structure: US 77,  Year Built: 2007,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 20,920 (year 2011),  Truck Traffic: 9%,  Average Future Daily Traffic: 30,670 (year 2031),  Design Load: HL 93,  Features Intersected: Carmen Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 41.698,  Lanes on structure: 3,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908355,  Location: 2.05 Mi SE of SH 100 (Lat: 26.056131,  Lng: -97.562306),  Route carried "on" structure: US 77,  Year Built: 2007,  Status: Open,  Structure Length: 6.86m (22.51ft),  Average Daily Traffic: 20,920 (year 2011),  Truck Traffic: 9%,  Average Future Daily Traffic: 30,670 (year 2031),  Design Load: HL 93,  Features Intersected: Carmen Rd
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 40.226,  Lanes on structure: 3,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908388,  Location: 2.70 Mi SE of FM 732 (Lat: 26.081131,  Lng: -97.580175),  Route carried "on" structure: US 77,  Year Built: 2006,  Status: Open,  Structure Length: 7.86m (25.79ft),  Average Daily Traffic: 25,180 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 35,250 (year 2031),  Design Load: HS 25 or greater,  Features Intersected: SH 100
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 38.438,  Lanes on structure: 3,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 37.8m (124.0ft),  Curb-To-Curb Width: 17.3m (56.8ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908389,  Location: 2.70 Mi SE of FM 732 (Lat: 26.080692,  Lng: -97.579336),  Route carried "on" structure: US 77,  Year Built: 2006,  Status: Open,  Structure Length: 7.86m (25.79ft),  Average Daily Traffic: 25,180 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 35,250 (year 2031),  Design Load: HS 25 or greater,  Features Intersected: SH 100
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 38.438,  Lanes on structure: 3,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 37.8m (124.0ft),  Curb-To-Curb Width: 17.3m (56.8ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908432,  Location: IH69E/SH 550 INTERCHANG (Lat: 26.030550,  Lng: -97.533850),  Route carried "on" structure: Ramp Other road 550,  Year Built: 2015,  Status: Open,  Structure Length: 30.48m (100.00ft),  Average Daily Traffic: 16,835 (year 2013),  Truck Traffic: 8%,  Average Future Daily Traffic: 21,500 (year 2030),  Design Load: HL 93,  Features Intersected: IH 69E NB ENTRANCE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Toll: On toll road,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 9,  Length of Maximum Span: 36.0m (118.1ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908433,  Location: I69E/SH550 INTERCHANGE (Lat: 26.029503,  Lng: -97.532736),  Route carried "on" structure: Ramp State highway 550,  Year Built: 2015,  Status: Open,  Structure Length: 102.66m (336.81ft),  Average Daily Traffic: 16,835 (year 2013),  Truck Traffic: 8%,  Average Future Daily Traffic: 21,500 (year 2030),  Design Load: HL 93,  Features Intersected: IH 69E
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 14,  Toll: On toll road,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 39 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 25,  Length of Maximum Span: 67.1m (220.1ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 210310003908453,  Location: 2.3 MI S OF I-169 (Lat: 25.997350,  Lng: -97.525097),  Route carried "on" structure: State highway 69,  Year Built: 2020,  Status: Open,  Structure Length: 13.87m (45.51ft),  Average Daily Traffic: 5,660 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 1 (year 1900),  Design Load: HL 93,  Features Intersected: UPRR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.001,  Lanes on structure: 1,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 3,  Length of Maximum Span: 39.6m (129.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.4m (11.2ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of corrective action,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003908454,  Location: 2.3 MI S OF I-169 (Lat: 25.997094,  Lng: -97.525817),  Route carried "on" structure: ServiceState highway 69,  Year Built: 2020,  Status: Open,  Structure Length: 4.57m (14.99ft),  Average Daily Traffic: 5,660 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 7,700 (year 2037),  Design Load: HL 93,  Features Intersected: UPRR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.001,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 45.7m (149.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported in metric tons,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003909234,  Location: 0.90 MI S OF FM 3248 (Lat: 25.967142,  Lng: -97.512472),  Route carried "on" structure: US 77,  Year Built: 1990,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 8.69m (28.51ft),  Average Daily Traffic: 32,120 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 45,490 (year 2031),  Design Load: HS 20,  Features Intersected: MORRISON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 53.250,  Lanes on structure: 3,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 16.7m (54.8ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003909235,  Location: 0.90 MI S OF FM 3248 (Lat: 25.967083,  Lng: -97.512569),  Route carried "on" structure: US 77,  Year Built: 1990,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 8.69m (28.51ft),  Average Daily Traffic: 32,120 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 45,490 (year 2031),  Design Load: HS 20,  Features Intersected: MORRISON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 53.250,  Lanes on structure: 3,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 16.7m (54.8ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003909236,  Location: 2.80 Mi S of FM 1732 (Lat: 25.978703,  Lng: -97.518092),  Route carried "on" structure: US 77,  Year Built: 1990,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 6.25m (20.51ft),  Average Daily Traffic: 30,810 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 55,840 (year 2031),  Design Load: HS 20,  Features Intersected: FM 3248 (Alton Gloor)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 51.829,  Lanes on structure: 3,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 16.7m (54.8ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003909237,  Location: 2.80 Mi S of FM 1732 (Lat: 25.978664,  Lng: -97.518183),  Route carried "on" structure: US 77,  Year Built: 1990,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 6.25m (20.51ft),  Average Daily Traffic: 30,810 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 55,840 (year 2031),  Design Load: HS 20,  Features Intersected: FM 3248 (Alton Gloor)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 51.829,  Lanes on structure: 3,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 16.8m (55.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 29.0m (95.1ft),  Curb-To-Curb Width: 16.7m (54.8ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003910084,  Location: 0.25 MI E OF FM 1419 (Lat: 25.917139,  Lng: -97.377922),  Route carried "on" structure: State highway 4,  Year Built: 1962,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 2.44m (8.01ft),  Average Daily Traffic: 633 (year 2020),  Truck Traffic: 11%,  Average Future Daily Traffic: 390 (year 2033),  Features Intersected: DRAINAGE DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 27.605,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 210310003910094,  Location: 0.60 MI E OF FM 511 (Lat: 25.916992,  Lng: -97.397864),  Route carried "on" structure: State highway 4,  Year Built: 1940,  Year Reconstructed: 1964,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 5,859 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 8,040 (year 2033),  Features Intersected: DRAINAGE DITCH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 25.619,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 9 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Fair,  Culverts: Fair,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 210310003910336,  Location: 4.45 MI E OF FM 1419 (Lat: 25.952853,  Lng: -97.326367),  Route carried "on" structure: State highway 4,  Year Built: 2002,  Status: Open,  Structure Length: 2.01m (6.59ft),  Average Daily Traffic: 462 (year 2018),  Truck Traffic: 9%,  Average Future Daily Traffic: 290 (year 2033),  Design Load: HS 20,  Features Intersected: DRAIN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 34.467,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 13.3m (43.6ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 210310003910337,  Location: 4.95 MI E OF FM 1419 (Lat: 25.953992,  Lng: -97.318433),  Route carried "on" structure: State highway 4,  Year Built: 2002,  Status: Open,  Structure Length: 2.01m (6.59ft),  Average Daily Traffic: 462 (year 2018),  Truck Traffic: 9%,  Average Future Daily Traffic: 290 (year 2033),  Design Load: HS 20,  Features Intersected: DRAIN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 35.274,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 13.3m (43.6ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 21031000391617,  Location: AT JCT SH 4 (Lat: 25.908939,  Lng: -97.488203),  Route carried "on" structure: US 77,  Year Built: 1969,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 183.55m (602.20ft),  Average Daily Traffic: 30,670 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 47,850 (year 2031),  Design Load: HS 20,  Features Intersected: SH 4 12-14 & 24TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.180,  Lanes on structure: 2,  Lanes under structure: 22,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 9 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 61,  Length of Maximum Span: 52.1m (170.9ft),  Curb-To-Curb Width: 11.2m (36.7ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 210310003916171,  Location: AT JCT SH 4 (Lat: 25.908864,  Lng: -97.488319),  Route carried "on" structure: US 77,  Year Built: 1969,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 183.55m (602.20ft),  Average Daily Traffic: 30,670 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 47,850 (year 2031),  Design Load: HS 20,  Features Intersected: SH 4 12-14 & 24TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.180,  Lanes on structure: 2,  Lanes under structure: 22,  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 9 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 62,  Length of Maximum Span: 52.1m (170.9ft),  Curb-To-Curb Width: 11.2m (36.7ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 210310003916172,  Location: 0.02 MI NE OF US 77 (Lat: 25.908725,  Lng: -97.487692),  Route carried "on" structure: ServiceUS 77,  Year Built: 1969,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 5,440 (year 2011),  Truck Traffic: 8%,  Average Future Daily Traffic: 8,480 (year 2031),  Features Intersected: TOWN RESACA
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.426,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 210310003916264,  Location: 0.25 MI NW OF SH 4 (Lat: 25.906983,  Lng: -97.486661),  Route carried "on" structure: Ramp US 77,  Year Built: 2000,  Status: Open,  Structure Length: 20.15m (66.11ft),  Average Daily Traffic: 2,744 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 15,840 (year 2037),  Design Load: HS 20,  Features Intersected: 14TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.201,  Lanes on structure: 1,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 34.1m (111.9ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003916265,  Location: 0.25 MI NW OF SH 4 (Lat: 25.907233,  Lng: -97.485925),  Route carried "on" structure: Ramp US 77,  Year Built: 2000,  Status: Open,  Structure Length: 15.54m (50.98ft),  Average Daily Traffic: 5,440 (year 2017),  Truck Traffic: 8%,  Average Future Daily Traffic: 8,480 (year 2037),  Design Load: HS 20,  Features Intersected: 14TH ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.201,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 34.1m (111.9ft),  Curb-To-Curb Width: 10.6m (34.8ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003916268,  Location: US 77 AND SH 4 (Lat: 25.902361,  Lng: -97.482456),  Route carried "on" structure: Ramp US 77,  Year Built: 1999,  Status: Open,  Structure Length: 36.82m (120.80ft),  Average Daily Traffic: 2,744 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 3,950 (year 2037),  Design Load: HS 20,  Features Intersected: TOWN RESACA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.201,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 10,  Length of Maximum Span: 32.9m (107.9ft),  Curb-To-Curb Width: 10.6m (34.8ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 210310003916269,  Location: US 77 AND SH 4 (Lat: 25.903528,  Lng: -97.482433),  Route carried "on" structure: Ramp US 77,  Year Built: 1999,  Status: Open,  Structure Length: 51.66m (169.49ft),  Average Daily Traffic: 2,744 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 3,950 (year 2037),  Design Load: HS 20,  Features Intersected: TOWN RESACA CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.201,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 13,  Number Of Approach Spans: 4,  Length of Maximum Span: 32.9m (107.9ft),  Curb-To-Curb Width: 7.7m (25.3ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 51.66m (169.49ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Bridge Improvement Cost: $85,000,  Roadway Improvement Cost: $21,000,  Total Project Cost: $106,000,  Deck Structure Type: Concrete Precast Panels
Discuss Brownsville, Texas (TX) on our hugely popular Texas forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.