- Backflow protection
air gap, device standard, when required
- Cleanability of floors, walls, and ceilings
1) Walls in following areas are not smooth, easily cleanable, and nonabsorbent: FRP by kitchen door, under kitchen 3 hole sink, and escutcheon cover by grease trap. 2) Cove base is missing in following areas: along serving window wall, west wall in kitchen, and missing in walk in cooler. 3) Must provide shatter resistant bulbs in prep area.
- Material characteristics of non-food contact surfaces
1) Bar top by the beer tapper is not flush with rest of bar top and is not sealed. Piece was installed seperately from rest of bar top. 2) Walk in cooler door gasket is no longer intact.
- Plumbing
cleanable fixtures
- Plumbing system repaired according to law
1) Walk in cooler and ice machine are soft plumbed. Must hard plumb lines to prevent buildup of bacteria. 2) Urinal in mens RR leaks.
- Roasts held at a temperature of 130°F or above
Walk in cooler was temped @ 65*F. Must maintain cooler @ 41*F.
- Light bulbs, protective shielding
1) Walls in following areas are not smooth, easily cleanable, and nonabsorbent: FRP by kitchen door, under kitchen 3 hole sink, and escutcheon cover by grease trap. 2) Cove base is missing in following areas: along serving window wall, west wall in kitchen, and missing in walk in cooler. 3) Must provide shatter resistant bulbs in prep area.
- Laundry facilities
requirement, location, and use
|
12/19/2013 | Routine |
Restaurant representatives - add corrected or new information about Golden W, 58 Miller Sw Ave, Cedar Rapids, IA 52404 »