Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Washington, District of Columbia (DC)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 506Number of bridges
  • 7,897ft / 2,407mTotal length
  • $289,689,000Total costs
  • 8,096,312Total average daily traffic
  • 287,304Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Washington
  • No street view available for this location

New bridges in Washington, DC - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 191900-1909
  • 61910-1919
  • 111920-1929
  • 281930-1939
  • 511940-1949
  • 871950-1959
  • 2101960-1969
  • 161970-1979
  • 21980-1989
  • 61990-1999
  • 32000-2009
  • 552010-2019
  • 112020-2022
Reconstructed bridges in Washington, DC - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11940-1949
  • 01950-1959
  • 21960-1969
  • 141970-1979
  • 441980-1989
  • 461990-1999
  • 322000-2009
  • 132010-2019
  • 22020-2022
Average Bridge Daily Traffic in Washington, DC
Average Bridge Truck Traffic in Washington, DC
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 6.4%Very good
  • 48.9%Good
  • 33.9%Satisfactory
  • 9.0%Fair
  • 1.7%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 13.9%Very good
  • 34.2%Good
  • 36.7%Satisfactory
  • 14.8%Fair
  • 0.4%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 8.0%Very good
  • 35.9%Good
  • 45.6%Satisfactory
  • 10.5%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 8.7%Very good
  • 40.2%Good
  • 41.3%Satisfactory
  • 7.6%Fair
  • 2.2%Poor
Find on map >>   Show street view

Structure Number: 2,  Location: GEORGETOWN & C&O (Lat: 38.904311,  Lng: -77.062756),  Route carried "on" structure: City street ,  Year Built: 1831,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 7,400 (year 2006),  Truck Traffic: 1%,  Average Future Daily Traffic: 8,500 (year 2026),  Features Intersected: C&O CANAL,  Facility Carried by Structure: WISCONSIN AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Masonry,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.5m (54.1ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3,  Location: GEORGETOWN & C&O (Lat: 38.904336,  Lng: -77.062789),  Route carried "on" structure: City street ,  Year Built: 1900,  Year Reconstructed: 2021,  Status: Open,  Structure Length: 1.66m (5.45ft),  Average Daily Traffic: 1,000 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,000 (year 2027),  Design Load: HL 93,  Features Intersected: C&O CANAL,  Facility Carried by Structure: 31ST STREET N.W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Navigation Control: Yes ( Vertical Clearance: 3.0m (9.8ft), Horizontal Clearance: 6.0m (19.7ft)),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.6m (54.5ft),  Curb or Sidewalk Widths: Left: 3.9m (12.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 46.0 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4,  Location: GEORGETOWN & C&O (Lat: 38.904178,  Lng: -77.060150),  Route carried "on" structure: City street ,  Year Built: 1929,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 1,000 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,000 (year 2027),  Design Load: HS 20,  Features Intersected: C&O CANAL,  Facility Carried by Structure: JEFFERSON ST, N.W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 4.0m (13.1ft),  Navigation Control: Yes ( Vertical Clearance: 3.0m (9.8ft), Horizontal Clearance: 5.0m (16.4ft)),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 4.0m (13.1ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 80.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5,  Location: GEORGETOWN & C&O (Lat: 38.904203,  Lng: -77.059131),  Route carried "on" structure: City street ,  Year Built: 1929,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 1,000 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,000 (year 2027),  Design Load: HS 20,  Features Intersected: C&O CANAL,  Facility Carried by Structure: 30TH STREET, N.W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 4.2m (13.8ft),  Out-to-Out Width: 8.8m (28.9ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 80.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6,  Location: GEORGETOWN & C&O (Lat: 38.903958,  Lng: -77.058078),  Route carried "on" structure: City street ,  Year Built: 1900,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 1,000 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,000 (year 2027),  Design Load: HS 20,  Features Intersected: C&O CANAL,  Facility Carried by Structure: 29TH STREET, N.W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 80.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 7,  Location: WHITEHURST FRWY (Lat: 38.904625,  Lng: -77.068825),  Route carried "on" structure: US 29,  Year Built: 1925,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 52.99m (173.85ft),  Average Daily Traffic: 62,000 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 65,000 (year 2040),  Design Load: HS 20,  Features Intersected: WHITEHURST FRWY,  Facility Carried by Structure: Key Bridge
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Navigation Control: Yes ( Vertical Clearance: 22.0m (72.2ft), Horizontal Clearance: 63.0m (206.7ft)),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 63.4m (208.0ft),  Curb or Sidewalk Widths: Left: 3.1m (10.2ft),  Right: 3.1m (10.2ft),  Curb-To-Curb Width: 20.1m (65.9ft),  Out-to-Out Width: 27.4m (89.9ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2021,  Underwater Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7(EAST RAMP),  Location: KEY BRIDGE OVER POTOMAC R (Lat: 38.903839,  Lng: -77.068050),  Route carried "on" structure: Ramp US 29,  Year Built: 1956,  Year Reconstructed: 2007,  Status: Open,  Structure Length: 8.60m (28.22ft),  Average Daily Traffic: 20,000 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 30,000 (year 2030),  Design Load: HS 20,  Features Intersected: STORAGE YD NEAR POTOMAC,  Facility Carried by Structure: E RAMP TO WH FRWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1,  Location: VA. AVE. OVER 23RD ST. (Lat: 38.897233,  Lng: -77.050122),  Route carried "on" structure: US ,  Year Built: 1942,  Year Reconstructed: 2002,  Status: Open,  Structure Length: 2.07m (6.79ft),  Average Daily Traffic: 20,500 (year 2007),  Truck Traffic: 2%,  Average Future Daily Traffic: 20,500 (year 2026),  Design Load: HS 20,  Features Intersected: VIRGINIA AVENUE, N.W.,  Facility Carried by Structure: 23RD STREET, N.W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 10.1m (33.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 26.2m (86.0ft),  Out-to-Out Width: 43.9m (144.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11,  Location: M STREET & S. CAPITOL (Lat: 38.876450,  Lng: -77.009236),  Route carried "on" structure: City street ,  Year Built: 1959,  Year Reconstructed: 1988,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 20,500 (year 2007),  Truck Traffic: 2%,  Average Future Daily Traffic: 22,000 (year 2026),  Design Load: HS 20,  Features Intersected: SOUTH CAPITOL STREET,  Facility Carried by Structure: M STREET, S.W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 22.6m (74.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.9m (62.0ft),  Curb or Sidewalk Widths: Left: 3.5m (11.5ft),  Right: 7.4m (24.3ft),  Curb-To-Curb Width: 22.6m (74.1ft),  Out-to-Out Width: 34.1m (111.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 17,  Location: 27th Street, N.W. (Lat: 38.956736,  Lng: -77.057933),  Route carried "on" structure: City street ,  Year Built: 2015,  Status: Open,  Structure Length: 1.29m (4.23ft),  Average Daily Traffic: 2,200 (year 2007),  Average Future Daily Traffic: 2,250 (year 2027),  Design Load: HL 93,  Features Intersected: Broad Branch,  Facility Carried by Structure: 27th Street, N.W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.9m (42.3ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.0m,  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 42.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2019,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 19,  Location: BURROUGHS&KENILWORTH (Lat: 38.901944,  Lng: -76.944167),  Route carried "on" structure: City street 295,  Year Built: 1956,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 7.68m (25.20ft),  Average Daily Traffic: 102,600 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 105,000 (year 2027),  Design Load: HS 20,  Features Intersected: BURROUGHS AVE & RAMP,  Facility Carried by Structure: KENILWORTH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 28.0m (91.9ft),  Skew: 31 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 38.1m (125.0ft),  Curb-To-Curb Width: 28.0m (91.9ft),  Out-to-Out Width: 33.8m (110.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 78.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 47.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 19-1(HIGH),  Location: OVER WATTS BRANCH, N.E. (Lat: 38.901667,  Lng: -76.944722),  Route carried "on" structure: City street ,  Year Built: 1956,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 1.65m (5.41ft),  Average Daily Traffic: 102,600 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 105,000 (year 2027),  Design Load: HS 20,  Features Intersected: WATTS BRANCH,  Facility Carried by Structure: KENILWORTH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 28.0m (91.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 28.0m (91.9ft),  Out-to-Out Width: 33.8m (110.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 67.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 19-1(LOW),  Location: OVER WATTS BR, N.E. (Lat: 38.901575,  Lng: -76.944431),  Route carried "on" structure: Ramp City street ,  Year Built: 1956,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 1.64m (5.38ft),  Average Daily Traffic: 13,000 (year 2007),  Truck Traffic: 2%,  Average Future Daily Traffic: 15,000 (year 2027),  Design Load: HS 20,  Features Intersected: WATTS BRANCH,  Facility Carried by Structure: N.RAMP TO BURR.AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 64.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2,  Location: PIERCE MILL & ROCK CR (Lat: 38.939742,  Lng: -77.051481),  Route carried "on" structure: City street ,  Year Built: 1900,  Year Reconstructed: 1993,  Status: Open,  Structure Length: 4.12m (13.52ft),  Average Daily Traffic: 11,900 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 12,500 (year 2027),  Design Load: HS 20,  Features Intersected: ROCK CREEK,  Facility Carried by Structure: PARK ROAD, N.W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.5m (21.3ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 21.3m (69.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 6.5m (21.3ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 65.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 21,  Location: 14TH & C STREETS, S.W (Lat: 38.881411,  Lng: -77.031956),  Route carried "on" structure: US ,  Year Built: 1942,  Status: Open,  Structure Length: 19.51m (64.01ft),  Average Daily Traffic: 55,700 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 56,000 (year 2027),  Design Load: H 20,  Features Intersected: STREET CAR TERMINAL,  Facility Carried by Structure: 14TH STREET, S.W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 37.5m (123.0ft),  Skew: 9 degrees,  Material/Design: Steel,  Design/Construction: Frame,  Number Of Spans In Main Unit: 32,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 0.0m,  Curb-To-Curb Width: 29.5m (96.8ft),  Out-to-Out Width: 37.5m (123.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 21.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 22,  Location: OVER PINEY BR PKWY, N.W. (Lat: 38.937856,  Lng: -77.036447),  Route carried "on" structure: US ,  Year Built: 1906,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 8.29m (27.20ft),  Average Daily Traffic: 30,600 (year 2008),  Truck Traffic: 3%,  Average Future Daily Traffic: 32,500 (year 2028),  Design Load: HS 20,  Features Intersected: PINEY BRANCH PARKWAY,  Facility Carried by Structure: 16TH STREET. N.W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 38.1m (125.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 71.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 23,  Location: N. CAPITAL & IRVING STS. (Lat: 38.931667,  Lng: -77.006667),  Route carried "on" structure: City street ,  Year Built: 1956,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 4.02m (13.19ft),  Average Daily Traffic: 31,900 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 35,000 (year 2027),  Design Load: HS 20,  Features Intersected: IRVING ST INTERCHANGE,  Facility Carried by Structure: NORTH CAPITOL ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 29.3m (96.1ft),  Skew: 22 degrees,  Material/Design: Concrete continuous,  Design/Construction: Frame,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 19.5m (64.0ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 29.3m (96.1ft),  Out-to-Out Width: 35.4m (116.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 25,  Location: OVER PINEY BRANCH PKWY,NW (Lat: 38.936161,  Lng: -77.046139),  Route carried "on" structure: City street ,  Year Built: 1959,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 10.03m (32.91ft),  Average Daily Traffic: 11,900 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 13,500 (year 2027),  Design Load: HS 20,  Features Intersected: PINEY BRANCH PKWY,  Facility Carried by Structure: PARK ROAD, N.W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 4,  Length of Maximum Span: 62.8m (206.0ft),  Curb or Sidewalk Widths: Left: 2.9m (9.5ft),  Right: 2.9m (9.5ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 62.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 26-1,  Location: ROCK CREEK & BEACH DR (Lat: 38.933475,  Lng: -77.050800),  Route carried "on" structure: City street ,  Year Built: 1947,  Year Reconstructed: 2000,  Status: Open,  Structure Length: 7.22m (23.69ft),  Average Daily Traffic: 11,900 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 12,500 (year 2027),  Design Load: HS 20,  Features Intersected: ROCK CREEK & BEACH D,  Facility Carried by Structure: KLINGLE ROAD, N.W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 39 degrees,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 20.6m (67.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 58.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Critical Feature Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 26-2,  Location: PORTER ST AT ROCK CREEK (Lat: 38.933961,  Lng: -77.051822),  Route carried "on" structure: City street ,  Year Built: 1947,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 2.07m (6.79ft),  Average Daily Traffic: 11,900 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 12,500 (year 2027),  Design Load: HS 20,  Features Intersected: KLINGLE ROAD,  Facility Carried by Structure: PORTER STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 23 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.5m (64.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 23.5m (77.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 84.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 26-3,  Location: OVER ROCK CREEK (Lat: 38.934189,  Lng: -77.049231),  Route carried "on" structure: City street ,  Year Built: 1947,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 1,000 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,100 (year 2027),  Design Load: HS 20,  Features Intersected: ROCK CREEK,  Facility Carried by Structure: KLINGLE ROAD, N.W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.3m (60.0ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 59.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Critical Feature Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 29,  Location: OVER ROCK CREEK, N.W. (Lat: 38.921667,  Lng: -77.050328),  Route carried "on" structure: City street ,  Year Built: 1907,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 23.07m (75.69ft),  Average Daily Traffic: 29,100 (year 2007),  Truck Traffic: 2%,  Average Future Daily Traffic: 30,500 (year 2027),  Design Load: HS 20,  Features Intersected: ROCK CREEK & POTOMAC PKW,  Facility Carried by Structure: CONNECTICUT AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete continuous,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 44.5m (146.0ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 19.9m (65.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 49.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 3,  Location: OVER ROCK CREEK, N.W. (Lat: 38.923275,  Lng: -77.047558),  Route carried "on" structure: City street ,  Year Built: 1933,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 23.07m (75.69ft),  Average Daily Traffic: 13,900 (year 2007),  Truck Traffic: 2%,  Average Future Daily Traffic: 15,000 (year 2026),  Design Load: HS 20,  Features Intersected: ROCK CREEK & PARK DR,  Facility Carried by Structure: CALVERT STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Material/Design: Concrete continuous,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 10,  Length of Maximum Span: 54.9m (180.1ft),  Curb or Sidewalk Widths: Left: 3.7m (12.1ft),  Right: 3.7m (12.1ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 26.8m (87.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 60.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 32,  Location: GEORGETOWN WATERFRONT, NW (Lat: 38.904494,  Lng: -77.065000),  Route carried "on" structure: US 29,  Year Built: 1949,  Year Reconstructed: 1998,  Status: Posted for load,  Structure Length: 127.16m (417.19ft),  Average Daily Traffic: 31,200 (year 2006),  Truck Traffic: 4%,  Average Future Daily Traffic: 32,500 (year 2026),  Design Load: HS 20,  Features Intersected: K Street, N.W.,  Facility Carried by Structure: WHITEHURST FRWY
Minimum Vertical Clearance: 4.30m (14.11ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 39 degrees,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 76,  Number Of Approach Spans: 18,  Length of Maximum Span: 23.2m (76.1ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 18.9m (62.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 31.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Critical Feature Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 32(TO KEY BR),  Location: RAMP OVER C&O CANAL (Lat: 38.904842,  Lng: -77.070217),  Route carried "on" structure: Ramp US 29,  Year Built: 1949,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 2.87m (9.42ft),  Average Daily Traffic: 31,200 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 32,500 (year 2026),  Design Load: HS 20,  Features Intersected: C&O CANAL, N.W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 17.4m (57.1ft),  Skew: 36 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.7m (94.2ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.3m (4.3ft),  Curb-To-Curb Width: 17.4m (57.1ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 32-2,  Location: K Street (Lat: 38.902436,  Lng: -77.058044),  Route carried "on" structure: Ramp City street _,  Year Built: 1949,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 8.17m (26.80ft),  Average Daily Traffic: 12,500 (year 2012),  Truck Traffic: 2%,  Average Future Daily Traffic: 13,000 (year 2022),  Design Load: HS 20,  Features Intersected: K Street exit Ramp,  Facility Carried by Structure: K Street Ramp
Minimum Vertical Clearance: 6.10m (20.01ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 7.2m (23.6ft),  Material/Design: Concrete continuous,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 22.9m (75.1ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 32-3,  Location: K Street, N.W. (Lat: 38.902656,  Lng: -77.056989),  Route carried "on" structure: Ramp City street _,  Year Built: 1949,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 7.26m (23.82ft),  Average Daily Traffic: 12,500 (year 2012),  Truck Traffic: 2%,  Average Future Daily Traffic: 12,750 (year 2020),  Design Load: H 20,  Features Intersected: K Street Entrance Ramp,  Facility Carried by Structure: K Street Ramp
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 7.2m (23.6ft),  Material/Design: Concrete continuous,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 22.9m (75.1ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 33.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 34,  Location: P ST.OVER ROCK CREEK (Lat: 38.909636,  Lng: -77.050633),  Route carried "on" structure: City street ,  Year Built: 1935,  Year Reconstructed: 2004,  Status: Open,  Structure Length: 6.49m (21.29ft),  Average Daily Traffic: 8,100 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 8,200 (year 2027),  Design Load: HS 20,  Features Intersected: ROCK CREEK,  Facility Carried by Structure: P STREET, N.W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.5m (106.6ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 56.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 35,  Location: M ST. OVER PARKWAY N.W. (Lat: 38.905256,  Lng: -77.055864),  Route carried "on" structure: City street ,  Year Built: 1928,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 7.07m (23.20ft),  Average Daily Traffic: 10,800 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 11,000 (year 2027),  Design Load: HS 20,  Features Intersected: PARKWAY & ROCK CREEK,  Facility Carried by Structure: M STREET, N.W.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.8m (78.1ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 36(N&S Ramps),  Location: RAMPS OVER ROCK CREEK (Lat: 38.902542,  Lng: -77.057589),  Route carried "on" structure: Ramp City street ,  Year Built: 1940,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 2.37m (7.78ft),  Average Daily Traffic: 9,000 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 9,000 (year 2027),  Design Load: H 20,  Features Intersected: ROCK CREEK,  Facility Carried by Structure: RAMPS TO&FROM
Minimum Vertical Clearance: 3.34m (10.96ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.1m (39.7ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.7m (77.8ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 12.1m (39.7ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 47.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 36(POT. PKWY),  Location: K ST OVER POTOMAC PKWY NW (Lat: 38.902544,  Lng: -77.057042),  Route carried "on" structure: City street ,  Year Built: 1940,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 2.41m (7.91ft),  Average Daily Traffic: 31,800 (year 2007),  Truck Traffic: 1%,  Average Future Daily Traffic: 32,500 (year 2027),  Design Load: HS 20,  Features Intersected: POTOMAC PKWY,  Facility Carried by Structure: K STREET, N.W.
Minimum Vertical Clearance: 30.18m (99.02ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 26.1m (85.6ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.0m (68.9ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 26.1m (85.6ft),  Out-to-Out Width: 32.1m (105.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 36(ROCK CR),  Location: K ST OVER ROCK CREEK NW (Lat: 38.902525,  Lng: -77.057769),  Route carried "on" structure: City street ,  Year Built: 1940,  Year Reconstructed: 1949,  Status: Open,  Structure Length: 2.29m (7.51ft),  Average Daily Traffic: 31,800 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 32,500 (year 2027),  Design Load: HS 20,  Features Intersected: ROCK CREEK,  Facility Carried by Structure: K STREET, N.W.
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.0m (68.9ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Low Slump Concrete
Find on map >>   Show street view

Structure Number: 38,  Location: KENILWORTH AVE OVER E CAP (Lat: 38.890436,  Lng: -76.957978),  Route carried "on" structure: City street ,  Year Built: 1952,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 3.35m (10.99ft),  Average Daily Traffic: 101,800 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 102,500 (year 2027),  Design Load: HS 20,  Features Intersected: EAST CAPITOL ST,  Facility Carried by Structure: KENILWORTH AVE NB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 35 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 16.8m (55.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.9m (3.0ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 24.1m (79.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4,  Location: MINNESOTA AVE OVER E CAP (Lat: 38.889886,  Lng: -76.952994),  Route carried "on" structure: City street ,  Year Built: 1954,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 2.16m (7.09ft),  Average Daily Traffic: 31,400 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 32,000 (year 2027),  Design Load: HS 20,  Features Intersected: EAST CAPITOL ST,  Facility Carried by Structure: MINNESOTA AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 7,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 27.7m (90.9ft),  Skew: 23 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 11.9m (39.0ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 27.7m (90.9ft),  Out-to-Out Width: 36.6m (120.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 40-1,  Location: 35th St over East Capitol (Lat: 38.889889,  Lng: -76.955889),  Route carried "on" structure: City street ,  Year Built: 1954,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 2.46m (8.07ft),  Average Daily Traffic: 2,500 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,550 (year 2027),  Design Load: HS 20,  Features Intersected: EAST CAPITOL ST,  Facility Carried by Structure: 35TH ST, N.E.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 11.5m (37.7ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 75.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 41,  Location: RFK Stadium (Lat: 38.892656,  Lng: -76.972883),  Route carried "on" structure: City street ,  Year Built: 1954,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 1.77m (5.81ft),  Average Daily Traffic: 20,000 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 20,500 (year 2027),  Design Load: HS 20,  Features Intersected: Pedestrian Walkway,  Facility Carried by Structure: C Street, N.E.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.7m (58.1ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 14.9m (48.9ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 82.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 41-1,  Location: RAMP A-B OVER PED. WALK (Lat: 38.891892,  Lng: -76.971667),  Route carried "on" structure: City street ,  Year Built: 1954,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 32,300 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 32,500 (year 2027),  Design Load: HS 20,  Features Intersected: PEDESTRIAN WALK,  Facility Carried by Structure: C Street, N.E.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 24.2m (79.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 60.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 41-2,  Location: Ind. Ave. over Ped. Walk (Lat: 38.904558,  Lng: -76.971781),  Route carried "on" structure: City street ,  Year Built: 1954,  Year Reconstructed: 1992,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 21,300 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 21,500 (year 2027),  Design Load: HS 20,  Features Intersected: PEDESTRIAN WALK,  Facility Carried by Structure: Independence Ave.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 17.2m (56.4ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 0.9m (3.0ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 17.2m (56.4ft),  Out-to-Out Width: 20.3m (66.6ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing