Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Thornton, Colorado (CO)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 96Number of bridges
  • 1,142ft / 348mTotal length
  • $6,185,000Total costs
  • 1,688,050Total average daily traffic
  • 114,960Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Thornton
  • No street view available for this location

New bridges in Thornton, CO - historical statistics
  • New bridges - historical statistics
  • 11940-1949
  • 41950-1959
  • 61960-1969
  • 61970-1979
  • 21980-1989
  • 91990-1999
  • 582000-2009
  • 92010-2019
  • 12020-2022
Reconstructed bridges in Thornton, CO - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11970-1979
  • 11980-1989
  • 01990-1999
  • 12000-2009
Average Bridge Daily Traffic in Thornton, CO
Average Bridge Truck Traffic in Thornton, CO
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 13.0%Very good
  • 54.3%Good
  • 21.7%Satisfactory
  • 10.9%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 15.2%Very good
  • 47.8%Good
  • 23.9%Satisfactory
  • 8.7%Fair
  • 4.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 6.5%Very good
  • 58.7%Good
  • 19.6%Satisfactory
  • 10.9%Fair
  • 4.3%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.3%Very good
  • 27.5%Good
  • 31.4%Satisfactory
  • 7.8%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 7.1%Very good
  • 39.3%Good
  • 53.6%Satisfactory
Find on map >>   Show street view

Structure Number: ADA04.6N-143.06,  Location: 0.1 MI S OF 144TH AVE (Lat: 39.956356,  Lng: -104.967192),  Route carried "on" structure: County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 0.72m (2.36ft),  Average Daily Traffic: 338 (year 2021),  Average Future Daily Traffic: 440 (year 2041),  Design Load: HS 20,  Features Intersected: LAKE ERIE TRIB,  Facility Carried by Structure: FRANKLIN ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.579,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.3m (10.8ft),  Out-to-Out Width: 61.6m (202.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: ADA06.0-163.8,  Location: 0.5 MI S of 168th AVENUE (Lat: 39.993114,  Lng: -104.940311),  Route carried "on" structure: County highway ,  Year Built: 2014,  Status: Open,  Structure Length: 0.78m (2.56ft),  Average Daily Traffic: 3,245 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 4,219 (year 2041),  Features Intersected: BIG DRY CREEK,  Facility Carried by Structure: COLORADO BLVD.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.548,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Channel: Good,  Culverts: Very good,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: ADA097-07.4N048,  Location: 0.4 MILE N OF 96TH AVENUE (Lat: 39.874244,  Lng: -104.913517),  Route carried "on" structure: County highway ,  Year Built: 1965,  Status: Open,  Structure Length: 5.55m (18.21ft),  Average Daily Traffic: 12,861 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 16,719 (year 2041),  Features Intersected: SOUTH PLATTE RIVER,  Facility Carried by Structure: Mc KAY ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.719,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.4m (57.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 29.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 17.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.55m (18.21ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2021,  Bridge Improvement Cost: $851,000,  Roadway Improvement Cost: $85,000,  Total Project Cost: $936,000 ( Estimate for 2014),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: ADA120-07.9E305,  Location: 2 MI W OF US85 (Lat: 39.914197,  Lng: -104.893053),  Route carried "on" structure: County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 4.57m (14.99ft),  Average Daily Traffic: 9,443 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 12,276 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: RIVERDALE RD,  Facility Carried by Structure: 120TH AVE EBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.858,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.2m (30.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 44.2m (145.0ft),  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 29.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: ADA120-07.9W304,  Location: 2 MI W OF US85 (Lat: 39.914167,  Lng: -104.893006),  Route carried "on" structure: County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 4.57m (14.99ft),  Average Daily Traffic: 9,443 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 12,276 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: RIVERDALE RD,  Facility Carried by Structure: 120TH AVE WBND
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.863,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 44.2m (145.0ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 0.0m,  Curb-To-Curb Width: 13.2m (43.3ft),  Out-to-Out Width: 17.5m (57.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 35.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: ADA120-08.8W306,  Location: 2 MI W OF US85 (Lat: 39.913536,  Lng: -104.888664),  Route carried "on" structure: County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 3.79m (12.43ft),  Average Daily Traffic: 9,217 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 11,982 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: BRANTNER DITCH,  Facility Carried by Structure: 120TH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.254,  Lanes on structure: 6,  Owner: County Highway Agency,  Approaching Roadway Width: 18.4m (60.4ft),  Skew: 21 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 36.1m (118.4ft),  Curb-To-Curb Width: 34.1m (111.9ft),  Out-to-Out Width: 35.0m (114.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: ADA127-09.5N193,  Location: 0.2 MI W OF MAIN ENTRANCE (Lat: 39.928047,  Lng: -104.877031),  Route carried "on" structure: County highway ,  Year Built: 1993,  Status: Open,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 281 (year 2021),  Average Future Daily Traffic: 366 (year 2041),  Design Load: HS 20,  Features Intersected: BRANTNER GULCH,  Facility Carried by Structure: FAIRGROUNDS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.283,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.1m (33.1ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: ADA143-4.577,  Location: 0.1 MI E OF FRANKLIN ST (Lat: 39.955850,  Lng: -104.966494),  Route carried "on" structure: County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 1.05m (3.44ft),  Average Daily Traffic: 50 (year 2021),  Average Future Daily Traffic: 65 (year 2041),  Design Load: HS 20,  Features Intersected: LAKE ERIE TRIB.,  Facility Carried by Structure: E. 143RD AVE
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 0.206,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.1m (16.7ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021
Find on map >>   Show street view

Structure Number: ADA156-05N.1017,  Location: 0.2 MI E OF YORK ST (Lat: 39.979239,  Lng: -104.956356),  Route carried "on" structure: City street ,  Year Built: 1995,  Status: Open,  Structure Length: 1.08m (3.54ft),  Average Daily Traffic: 219 (year 2021),  Average Future Daily Traffic: 285 (year 2041),  Features Intersected: BIG DRY CREEK,  Facility Carried by Structure: 156TH AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.259,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.0m (32.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 51.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Corrugated Steel,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: BRI102-124,  Location: 0.1 M E OF RIVERDALE RD (Lat: 39.925056,  Lng: -104.882778),  Route carried "on" structure: County highway ,  Year Built: 1940,  Year Reconstructed: 1970,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 10,583 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 13,757 (year 2041),  Features Intersected: BRANTNER DITCH,  Facility Carried by Structure: HENDERSON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.074,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 12.5m (41.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: E-17-ACR,  Location: THORNTON (Lat: 39.848886,  Lng: -104.986050),  Route carried "on" structure: City street ,  Year Built: 2012,  Status: Open,  Structure Length: 7.85m (25.75ft),  Average Daily Traffic: 33,457 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 43,494 (year 2041),  Features Intersected: I 25 ML,  Facility Carried by Structure: 84TH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.658,  Lanes on structure: 8,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 31.7m (104.0ft),  Skew: 21 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 38.5m (126.3ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 31.7m (104.0ft),  Out-to-Out Width: 38.7m (127.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 58.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-17-ADL,  Location: 1.2 MI NE OF JCT I 270 (Lat: 39.828597,  Lng: -104.944097),  Route carried "on" structure: Interstate 76A,  Year Built: 2011,  Status: Open,  Structure Length: 5.43m (17.81ft),  Average Daily Traffic: 84,000 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 123,480 (year 2040),  Design Load: HL 93,  Features Intersected: UP RR,  Facility Carried by Structure: I 76 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.653,  Lanes on structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 37.5m (123.0ft),  Skew: 33 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 42.1m (138.1ft),  Out-to-Out Width: 43.6m (143.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 29.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 22.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.79m (15.72ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $846,000,  Roadway Improvement Cost: $85,000,  Total Project Cost: $1,269,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-17-ADM,  Location: 0.5 MI W OF WASHINGTON ST (Lat: 39.928467,  Lng: -104.988344),  Route carried "on" structure: City street ,  Year Built: 2008,  Status: Open,  Structure Length: 8.24m (27.03ft),  Average Daily Traffic: 15,767 (year 2021),  Average Future Daily Traffic: 20,498 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: I25 ML,  Facility Carried by Structure: 128TH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.106,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 39.9m (130.9ft),  Curb or Sidewalk Widths: Left: 3.2m (10.5ft),  Right: 3.2m (10.5ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 23.2m (76.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-17-ADR,  Location: W. EDGE OF BRIGHTON (Lat: 39.986864,  Lng: -104.832814),  Route carried "on" structure: State highway 7D,  Year Built: 2009,  Status: Open,  Structure Length: 9.50m (31.17ft),  Average Daily Traffic: 16,000 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 21,600 (year 2040),  Features Intersected: SOUTH PLATTE RIVER,  Facility Carried by Structure: SH 7 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.772,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 32.7m (107.3ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 82.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 9.96m (32.68ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Bridge Improvement Cost: $1,456,000,  Roadway Improvement Cost: $145,000,  Total Project Cost: $2,184,000,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-17-AEA,  Location: AT 74TH AVE (Lat: 39.830614,  Lng: -104.941689),  Route carried "on" structure: Interstate 76A,  Year Built: 2010,  Status: Open,  Structure Length: 5.96m (19.55ft),  Average Daily Traffic: 84,000 (year 2020),  Truck Traffic: 13%,  Average Future Daily Traffic: 123,480 (year 2040),  Design Load: HS 25 or greater,  Features Intersected: SH 224 ML (74TH AVE),  Facility Carried by Structure: I-76 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.958,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 38.4m (126.0ft),  Skew: 34 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.5m (77.1ft),  Curb-To-Curb Width: 38.4m (126.0ft),  Out-to-Out Width: 39.9m (130.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 60.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-17-AU,  Location: 7.5 MI E OF JCT I 25 (Lat: 39.987194,  Lng: -104.847317),  Route carried "on" structure: State highway 7D,  Year Built: 1967,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 16,000 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 22,560 (year 2040),  Design Load: H 20,  Features Intersected: BRANTNER DITCH,  Facility Carried by Structure: SH 7 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.532,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.2m (10.5ft),  Out-to-Out Width: 25.1m (82.3ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020
Find on map >>   Show street view

Structure Number: E-17-FJ,  Location: THORNTON (Lat: 39.855186,  Lng: -104.986697),  Route carried "on" structure: Interstate 25A,  Year Built: 1955,  Status: Open,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 154,000 (year 2020),  Truck Traffic: 9%,  Average Future Daily Traffic: 189,420 (year 2040),  Design Load: HS 20,  Features Intersected: PEDESTRIAN UNDERPASS,  Facility Carried by Structure: I 25 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 352.118,  Lanes on structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 37.8m (124.0ft),  Skew: 32 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 37.8m (124.0ft),  Out-to-Out Width: 39.6m (129.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 57.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: E-17-HP,  Location: 2.6 MI E OF JCT US 36 (Lat: 39.830700,  Lng: -104.944886),  Route carried "on" structure: State highway 224A,  Year Built: 1963,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 4.98m (16.34ft),  Average Daily Traffic: 12,000 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 12,600 (year 2040),  Design Load: HS 20,  Features Intersected: I76 RAMP, UP RR,  Facility Carried by Structure: SH 224 ML
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 4.308,  Lanes on structure: 4,  Lanes under structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 25.0m (82.0ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 0.0m,  Curb-To-Curb Width: 25.0m (82.0ft),  Out-to-Out Width: 27.2m (89.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 63.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-17-LE,  Location: IN THORNTON (Lat: 39.856211,  Lng: -104.987589),  Route carried "on" structure: City street ,  Year Built: 1972,  Status: Open,  Structure Length: 6.98m (22.90ft),  Average Daily Traffic: 12,719 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 16,535 (year 2041),  Design Load: HS 20,  Features Intersected: I 25 ML,  Facility Carried by Structure: 88TH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.507,  Lanes on structure: 4,  Lanes under structure: 10,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 1 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 35.1m (115.2ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 19.6m (64.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: E-17-MJ,  Location: IN THORNTON (Lat: 39.867897,  Lng: -104.988042),  Route carried "on" structure: City street ,  Year Built: 1985,  Status: Open,  Structure Length: 7.59m (24.90ft),  Average Daily Traffic: 32,259 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 41,937 (year 2041),  Design Load: HS 20,  Features Intersected: I 25 ML,  Facility Carried by Structure: THORNTON PKWY 94TH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.724,  Lanes on structure: 5,  Lanes under structure: 7,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.0m (82.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 39.6m (129.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 25.0m (82.0ft),  Out-to-Out Width: 29.0m (95.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 50.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-17-QJ,  Location: SBND I25 & EBND I270 (Lat: 39.830656,  Lng: -104.983094),  Route carried "on" structure: Ramp Interstate 270B,  Year Built: 2009,  Status: Open,  Structure Length: 43.43m (142.49ft),  Average Daily Traffic: 18,000 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 45,520 (year 2028),  Design Load: HL 93,  Features Intersected: I25ML/I25HOV/WB I 270,  Facility Carried by Structure: I 270 EBND ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.346,  Lanes on structure: 2,  Lanes under structure: 9,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 61.0m (200.1ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-17-UZ,  Location: 2.3 MI E OF JCT I25 (Lat: 39.986364,  Lng: -104.946289),  Route carried "on" structure: State highway 7D,  Year Built: 2002,  Status: Open,  Structure Length: 6.17m (20.24ft),  Average Daily Traffic: 16,000 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 22,560 (year 2040),  Design Load: HL 93,  Features Intersected: BIG DRY CREEK,  Facility Carried by Structure: SH 7 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 14.079,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.5m (100.1ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 38.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-470-41.57C,  Location: 41.57 MI FROM I25 (Lat: 39.960917,  Lng: -104.903417),  Route carried "on" structure: County highway QUEBE,  Year Built: 2001,  Status: Open,  Structure Length: 7.22m (23.69ft),  Average Daily Traffic: 2,500 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 4,450 (year 2041),  Design Load: HS 25 or greater,  Features Intersected: E-470 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.798,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: Local Toll Authority,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.0m (118.1ft),  Curb or Sidewalk Widths: Left: 3.2m (10.5ft),  Right: 0.0m,  Curb-To-Curb Width: 14.1m (46.3ft),  Out-to-Out Width: 17.8m (58.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-470-42.45CBC,  Location: 42.45 MI FROM I25 (Lat: 39.966194,  Lng: -104.919806),  Route carried "on" structure: Other road E-470,  Year Built: 2002,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 36,702 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 65,329 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: Local Drainage
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 68.645,  Lanes on structure: 4,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 23.2m (76.1ft),  Skew: 34 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Out-to-Out Width: 119.5m (392.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: E-470-42.61A,  Location: 42.61 MI FROM I25 (Lat: 39.967372,  Lng: -104.921628),  Route carried "on" structure: Other road 470,  Year Built: 2001,  Status: Open,  Structure Length: 6.05m (19.85ft),  Average Daily Traffic: 18,236 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 32,460 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: Holly Street
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 68.574,  Lanes on structure: 2,  Lanes under structure: 2,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.3m (96.1ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-470-42.61B,  Location: 42.61 MI FROM I25 (Lat: 39.967111,  Lng: -104.921722),  Route carried "on" structure: Other road 470,  Year Built: 2001,  Status: Open,  Structure Length: 6.05m (19.85ft),  Average Daily Traffic: 18,466 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 32,869 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: Holly Street
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 68.831,  Lanes on structure: 2,  Lanes under structure: 2,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 13 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 29.3m (96.1ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 43.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-470-43.66C,  Location: 43.66 MI FROM I25 (Lat: 39.974222,  Lng: -104.937194),  Route carried "on" structure: Other road COLOR,  Year Built: 2001,  Status: Open,  Structure Length: 7.05m (23.13ft),  Average Daily Traffic: 944 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,958 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: E-470 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.059,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: Local Toll Authority,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 34.2m (112.2ft),  Curb or Sidewalk Widths: Left: 3.2m (10.5ft),  Right: 0.0m,  Curb-To-Curb Width: 14.7m (48.2ft),  Out-to-Out Width: 18.4m (60.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-470-44.62CBC,  Location: 44.62 MI FROM I-25 (Lat: 39.976222,  Lng: -104.949861),  Route carried "on" structure: Other road 470B,  Year Built: 2003,  Status: Open,  Structure Length: 0.71m (2.33ft),  Average Daily Traffic: 36,702 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 65,329 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: Local Drainage,  Facility Carried by Structure: E-470 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 71.527,  Lanes on structure: 6,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 28.7m (94.2ft),  Skew: 22 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Out-to-Out Width: 71.1m (233.3ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: E-470-44.83A,  Location: 44.83 MI FROM I25 (Lat: 39.976186,  Lng: -104.959469),  Route carried "on" structure: Other road 470B,  Year Built: 2003,  Status: Open,  Structure Length: 6.52m (21.39ft),  Average Daily Traffic: 18,236 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 32,460 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: York Street,  Facility Carried by Structure: E-470 NB
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 72.347,  Lanes on structure: 2,  Lanes under structure: 3,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.9m (104.7ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 49.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-470-44.83B,  Location: 44.83 MI FROM I25 (Lat: 39.975975,  Lng: -104.959450),  Route carried "on" structure: Other road 470,  Year Built: 2003,  Status: Open,  Structure Length: 6.52m (21.39ft),  Average Daily Traffic: 18,466 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 32,869 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: York Street
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 72.341,  Lanes on structure: 2,  Lanes under structure: 3,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 31.9m (104.7ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 49.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-470-44.98A,  Location: 44.98 MI FROM I25 (Lat: 39.976528,  Lng: -104.961722),  Route carried "on" structure: Other road 470,  Year Built: 2003,  Status: Open,  Structure Length: 7.09m (23.26ft),  Average Daily Traffic: 18,236 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 32,460 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: Big Dry Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 72.542,  Lanes on structure: 2,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 34.4m (112.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-470-44.98B,  Location: 44.98 MI FROM I25 (Lat: 39.976436,  Lng: -104.962186),  Route carried "on" structure: Other road 470,  Year Built: 2001,  Status: Open,  Structure Length: 7.09m (23.26ft),  Average Daily Traffic: 18,466 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 32,869 (year 2038),  Design Load: HS 25 or greater,  Features Intersected: Big Dry Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 72.578,  Lanes on structure: 2,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 34.4m (112.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-470-44.98C,  Location: BIG DRY CREEK (Lat: 39.977269,  Lng: -104.961719),  Route carried "on" structure: Ramp Other road 470,  Year Built: 2001,  Status: Open,  Structure Length: 6.75m (22.15ft),  Average Daily Traffic: 400 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 462 (year 2033),  Design Load: HS 25 or greater,  Features Intersected: Big Dry Creek,  Facility Carried by Structure: YORK ST NB RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.199,  Lanes on structure: 2,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.7m (107.3ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-470-44.98E,  Location: 44.98 MI FROM I25 (Lat: 39.975867,  Lng: -104.962303),  Route carried "on" structure: Ramp Other road 470,  Year Built: 2001,  Status: Open,  Structure Length: 6.61m (21.69ft),  Average Daily Traffic: 370 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 462 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: Big Dry Creek
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.680,  Lanes on structure: 2,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 32.1m (105.3ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-470-45.87C,  Location: 45.87 MI FROM I25 (Lat: 39.979203,  Lng: -104.977994),  Route carried "on" structure: Other road WASH,  Year Built: 2001,  Status: Open,  Structure Length: 7.77m (25.49ft),  Average Daily Traffic: 11,468 (year 2016),  Average Future Daily Traffic: 18,350 (year 2036),  Design Load: HS 25 or greater,  Features Intersected: E-470 ML
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.322,  Lanes on structure: 2,  Lanes under structure: 5,  Owner: Local Toll Authority,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 39.3m (128.9ft),  Curb or Sidewalk Widths: Left: 2.6m (8.5ft),  Right: 0.0m,  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-470-46.36D,  Location: 46.36 MI FROM I25 (Lat: 39.981889,  Lng: -104.985750),  Route carried "on" structure: Ramp Other road 470,  Year Built: 2003,  Status: Open,  Structure Length: 38.48m (126.25ft),  Average Daily Traffic: 830 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 1,780 (year 2035),  Design Load: HS 25 or greater,  Features Intersected: I25, E470 ML, RAMPS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.209,  Lanes on structure: 1,  Lanes under structure: 11,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 51.6m (169.3ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 58.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: E-470-46.39D,  Location: SB I25 TO SB E470 (Lat: 39.980889,  Lng: -104.986639),  Route carried "on" structure: Ramp Other road 470,  Year Built: 2003,  Status: Open,  Structure Length: 24.49m (80.35ft),  Average Daily Traffic: 6,600 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 6,800 (year 2025),  Design Load: HS 25 or greater,  Features Intersected: I25, NWP
Minimum Vertical Clearance: 6.68m (21.92ft),  Kilometerpoint: 0.545,  Lanes on structure: 2,  Lanes under structure: 8,  Toll: On toll road,  Owner: Local Toll Authority,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 69.3m (227.4ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 44.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: THN-086CLD-HFD,  Location: 0.6 MI EAST OF STEELE ST (Lat: 39.852872,  Lng: -104.939153),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 0.78m (2.56ft),  Average Daily Traffic: 286 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 372 (year 2041),  Design Load: HS 20,  Features Intersected: HOFFMAN DITCH,  Facility Carried by Structure: 86TH AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.7m (28.5ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 6.1m (20.0ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 39.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 1.44m (4.72ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Bridge Improvement Cost: $98,000,  Roadway Improvement Cost: $10,000,  Total Project Cost: $108,000 ( Estimate for 2014)
Find on map >>   Show street view

Structure Number: THN-086HUD-HFD,  Location: 0.5 MI E OF STEELE ST (Lat: 39.852331,  Lng: -104.941000),  Route carried "on" structure: City street ,  Year Built: 1992,  Status: Open,  Structure Length: 0.78m (2.56ft),  Design Load: HS 20,  Features Intersected: HOFFMAN DITCH,  Facility Carried by Structure: 86TH AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.005,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 5.6m (18.4ft),  Out-to-Out Width: 6.2m (20.3ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 39.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.44m (4.72ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Bridge Improvement Cost: $98,000,  Roadway Improvement Cost: $10,000,  Total Project Cost: $107,000 ( Estimate for 2014)
Find on map >>   Show street view

Structure Number: THN-088CLD-PLR,  Location: 1.36 MI W OF I-76 (Lat: 39.856094,  Lng: -104.937947),  Route carried "on" structure: City street ,  Year Built: 1960,  Status: Open,  Structure Length: 7.00m (22.97ft),  Average Daily Traffic: 25,590 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 33,267 (year 2041),  Features Intersected: SOUTH PLATTE RIVER,  Facility Carried by Structure: 88TH AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.138,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 16.8m (55.1ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 16.0m (52.5ft),  Out-to-Out Width: 20.3m (66.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Very good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss Thornton, Colorado (CO) on our hugely popular Colorado forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.