Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Taylor, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 75Number of bridges
  • 636ft / 194mTotal length
  • $250,804,000Total costs
  • 2,412,735Total average daily traffic
  • 243,194Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Taylor
  • No street view available for this location

New bridges in Taylor, MI - historical statistics
  • New bridges - historical statistics
  • 21920-1929
  • 41930-1939
  • 11940-1949
  • 11950-1959
  • 391960-1969
  • 51970-1979
  • 21980-1989
  • 11990-1999
  • 182000-2009
  • 12010-2019
  • 12020-2022
Reconstructed bridges in Taylor, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 11960-1969
  • 21970-1979
  • 01980-1989
  • 101990-1999
  • 42000-2009
  • 52010-2019
Average Bridge Daily Traffic in Taylor, MI
Average Bridge Truck Traffic in Taylor, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 7.0%Excellent
  • 7.0%Very good
  • 39.5%Good
  • 20.9%Satisfactory
  • 14.0%Fair
  • 11.6%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 20.9%Very good
  • 32.6%Good
  • 23.3%Satisfactory
  • 18.6%Fair
  • 4.7%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 7.0%Very good
  • 53.5%Good
  • 20.9%Satisfactory
  • 9.3%Fair
  • 7.0%Poor
  • 2.3%Serious
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 4.2%Very good
  • 37.5%Good
  • 33.3%Satisfactory
  • 12.5%Fair
  • 12.5%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 12.5%Excellent
  • 12.5%Very good
  • 50.0%Good
  • 12.5%Satisfactory
  • 12.5%Poor
Find on map >>   Show street view

Structure Number: 1112,  Location: COLDWATER TWP SEC 19-30 (Lat: 41.927247,  Lng: -85.048256),  Route carried "on" structure: County highway 2035,  Year Built: 1947,  Year Reconstructed: 2006,  Status: Posted for load,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 1,455 (year 2005),  Truck Traffic: 4%,  Average Future Daily Traffic: 1,920 (year 2025),  Design Load: HS 20,  Features Intersected: COLDWATER RIVER,  Facility Carried by Structure: GARFIELD ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.972,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.9m (48.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 42.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Length Of Structure Improvement: 1.52m (4.99ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Bridge Improvement Cost: $45,000,  Total Project Cost: $65,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1163,  Location: GIRARD TWP SEC 19 (Lat: 42.024081,  Lng: -85.054892),  Route carried "on" structure: County highway ,  Year Built: 2003,  Status: Open,  Structure Length: 2.32m (7.61ft),  Average Daily Traffic: 75 (year 2003),  Truck Traffic: 4%,  Average Future Daily Traffic: 125 (year 2023),  Design Load: HS 20,  Features Intersected: HOG CREEK,  Facility Carried by Structure: CADY ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.053,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.9m (71.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 72.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 1164,  Location: GIRARD TWP SEC 17-18 (Lat: 42.036058,  Lng: -85.040319),  Route carried "on" structure: County highway ,  Year Built: 1963,  Status: Posted for load,  Structure Length: 1.48m (4.86ft),  Average Daily Traffic: 207 (year 2004),  Truck Traffic: 4%,  Average Future Daily Traffic: 281 (year 2024),  Design Load: HS 20,  Features Intersected: HOG CREEK,  Facility Carried by Structure: RIVER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.450,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.2m (23.6ft),  Curb or Sidewalk Widths: Left: 0.8m (2.6ft),  Right: 0.0m,  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Poor,  Channel: Poor,  Operating Rating: 32.4 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Length Of Structure Improvement: 1.63m (5.35ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2021,  Bridge Improvement Cost: $226,000,  Roadway Improvement Cost: $25,000,  Total Project Cost: $298,000,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1188,  Location: IN VILLAGE OF UNION CITY (Lat: 42.065014,  Lng: -85.139128),  Route carried "on" structure: City street ,  Year Built: 1975,  Status: Posted for load,  Structure Length: 4.05m (13.29ft),  Average Daily Traffic: 1,800 (year 1976),  Average Future Daily Traffic: 2,700 (year 2010),  Design Load: H 20,  Features Intersected: ST JOSEPH RIVER,  Facility Carried by Structure: PARK STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.301,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.7m (54.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Length Of Structure Improvement: 6.10m (20.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Bridge Improvement Cost: $200,000,000,  Roadway Improvement Cost: $50,000,000,  Total Project Cost: $250,000,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1202,  Location: 3.2 MI N OF I-94 (Lat: 42.313297,  Lng: -85.181178),  Route carried "on" structure: Interstate 194,  Year Built: 1966,  Status: Open,  Structure Length: 6.29m (20.64ft),  Average Daily Traffic: 24,600 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 28,600 (year 2033),  Design Load: HS 20+Mod,  Features Intersected: GTW RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.768,  Lanes on structure: 6,  Base Highway Network: Yes (Inventory Route: 129,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 28.6m (93.8ft),  Skew: 31 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 31.2m (102.4ft),  Curb-To-Curb Width: 27.6m (90.6ft),  Out-to-Out Width: 29.7m (97.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 67.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 1522,  Location: 2.3 MI N OF OTSEGO COL (Lat: 45.225892,  Lng: -84.592450),  Route carried "on" structure: Interstate 75,  Year Built: 1962,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 7,777 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 8,944 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: STURGEON RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.689,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 55,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.5m (47.6ft),  Curb-To-Curb Width: 11.7m (38.4ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 1524,  Location: 2.5 MI N OF OTSEGO COL (Lat: 45.229364,  Lng: -84.587486),  Route carried "on" structure: Interstate 75,  Year Built: 1962,  Status: Open,  Structure Length: 7.68m (25.20ft),  Average Daily Traffic: 7,777 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 8,944 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: TROWBRIDGE & D&MRR(ABN)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.238,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 55,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.7m (67.9ft),  Curb-To-Curb Width: 10.2m (33.5ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 75.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 11117,  Location: W LTS OF TAYLOR (Lat: 42.247103,  Lng: -83.308278),  Route carried "on" structure: Interstate 94,  Year Built: 2002,  Status: Open,  Structure Length: 2.81m (9.22ft),  Average Daily Traffic: 74,175 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 78,763 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: INKSTER RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 19.905,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 157,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 26.2m (86.0ft),  Curb-To-Curb Width: 19.6m (64.3ft),  Out-to-Out Width: 20.6m (67.6ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11118,  Location: W LTS OF TAYLOR (Lat: 42.249708,  Lng: -83.308378),  Route carried "on" structure: Interstate 94,  Year Built: 2002,  Status: Open,  Structure Length: 3.82m (12.53ft),  Average Daily Traffic: 74,175 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 78,763 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: INKSTER RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 20.018,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 158,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 37.3m (122.4ft),  Curb-To-Curb Width: 19.7m (64.6ft),  Out-to-Out Width: 20.7m (67.9ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 75.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11119,  Location: IN TAYLOR,OVER ECORSE RD (Lat: 42.254089,  Lng: -83.298378),  Route carried "on" structure: Interstate 94,  Year Built: 1962,  Year Reconstructed: 1997,  Status: Open,  Structure Length: 7.22m (23.69ft),  Average Daily Traffic: 74,175 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 78,763 (year 2039),  Design Load: HS 20,  Features Intersected: ECORSE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 21.041,  Lanes on structure: 4,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 157,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 18.7m (61.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 62.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1112,  Location: IN TAYLOR,OVER ECORSE RD (Lat: 42.253797,  Lng: -83.303561),  Route carried "on" structure: Interstate 94,  Year Built: 1962,  Status: Temporarily open,  Structure Length: 7.22m (23.69ft),  Average Daily Traffic: 74,175 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 78,763 (year 2039),  Design Load: HS 20,  Features Intersected: ECORSE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 20.621,  Lanes on structure: 4,  Lanes under structure: 5,  Base Highway Network: Yes (Inventory Route: 158,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.8m (65.0ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 18.7m (61.4ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Poor,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 11121,  Location: IN TAYLOR,OVER BEECH-DALY (Lat: 42.261122,  Lng: -83.289397),  Route carried "on" structure: Interstate 94,  Year Built: 1962,  Year Reconstructed: 1977,  Status: Open,  Structure Length: 4.78m (15.68ft),  Average Daily Traffic: 60,077 (year 2007),  Truck Traffic: 13%,  Average Future Daily Traffic: 65,620 (year 2018),  Design Load: HS 20,  Features Intersected: BEECH-DALY RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 22.121,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 157,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 14.3m (46.9ft),  Out-to-Out Width: 15.4m (50.5ft)

Condition: Deck: Poor,  Superstructure: Satisfactory,  Substructure: Serious,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 11122,  Location: IN TAYLOR,OVER BEECH-DALY (Lat: 42.261639,  Lng: -83.289406),  Route carried "on" structure: Interstate 94,  Year Built: 1962,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 4.72m (15.49ft),  Average Daily Traffic: 74,175 (year 2019),  Truck Traffic: 9%,  Average Future Daily Traffic: 78,763 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: BEECH-DALY RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 22.089,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 158,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.5m (54.1ft),  Curb-To-Curb Width: 16.8m (55.1ft),  Out-to-Out Width: 17.8m (58.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 25.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11123,  Location: IN TAYLOR,US-24 (Lat: 42.264658,  Lng: -83.270253),  Route carried "on" structure: Interstate 94,  Year Built: 2004,  Status: Open,  Structure Length: 7.50m (24.61ft),  Average Daily Traffic: 81,200 (year 2013),  Truck Traffic: 8%,  Average Future Daily Traffic: 89,700 (year 2033),  Design Load: HS 25 or greater,  Features Intersected: US-24 (TELEGRAPH RD)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 23.758,  Lanes on structure: 3,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 157,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 20 degrees,  Material/Design: Steel,  Design/Construction: Arch - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 73.5m (241.1ft),  Curb-To-Curb Width: 22.0m (72.2ft),  Out-to-Out Width: 23.0m (75.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11124,  Location: IN TAYLOR,US-24 (Lat: 42.265006,  Lng: -83.270239),  Route carried "on" structure: Interstate 94,  Year Built: 2004,  Status: Open,  Structure Length: 7.50m (24.61ft),  Average Daily Traffic: 81,200 (year 2013),  Truck Traffic: 8%,  Average Future Daily Traffic: 89,700 (year 2033),  Design Load: HS 25 or greater,  Features Intersected: US-24(TELEGRAPH RD)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 23.729,  Lanes on structure: 3,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 158,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 21.9m (71.9ft),  Skew: 20 degrees,  Material/Design: Steel,  Design/Construction: Arch - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 73.5m (241.1ft),  Curb-To-Curb Width: 22.0m (72.2ft),  Out-to-Out Width: 23.0m (75.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11125,  Location: IN TAYLOR OVER MONROE BLV (Lat: 42.265469,  Lng: -83.250392),  Route carried "on" structure: Interstate 94,  Year Built: 2004,  Status: Open,  Structure Length: 3.81m (12.50ft),  Average Daily Traffic: 71,546 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 71,250 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: MONROE BLVD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 25.411,  Lanes on structure: 5,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 157,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.5m (77.1ft),  Curb-To-Curb Width: 25.6m (84.0ft),  Out-to-Out Width: 26.7m (87.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 86.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11126,  Location: IN TAYLOR OVER MONROE BLV (Lat: 42.265917,  Lng: -83.250406),  Route carried "on" structure: Interstate 94,  Year Built: 2004,  Status: Open,  Structure Length: 3.81m (12.50ft),  Average Daily Traffic: 71,546 (year 2007),  Truck Traffic: 10%,  Average Future Daily Traffic: 71,250 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: MONROE BLVD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 25.380,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 158,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.5m (77.1ft),  Curb-To-Curb Width: 25.6m (84.0ft),  Out-to-Out Width: 27.8m (91.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 84.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11272,  Location: IN TAYLOR (Lat: 42.255514,  Lng: -83.269989),  Route carried "on" structure: County highway 2057,  Year Built: 2004,  Status: Open,  Structure Length: 4.58m (15.03ft),  Average Daily Traffic: 20,000 (year 1978),  Truck Traffic: 9%,  Average Future Daily Traffic: 41,000 (year 2025),  Design Load: HS 25 or greater,  Features Intersected: US-24,  Facility Carried by Structure: ECORSE RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 17.641,  Lanes on structure: 4,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 20 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 22.9m (75.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 17.3m (56.8ft),  Out-to-Out Width: 24.0m (78.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 86.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11276,  Location: IN TAYLOR (Lat: 42.185111,  Lng: -83.267278),  Route carried "on" structure: US 24,  Year Built: 1986,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 24,955 (year 2007),  Truck Traffic: 2%,  Average Future Daily Traffic: 26,093 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: BLAKLEY DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.653,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 470,  Subroute: 38),  Owner: State Highway Agency,  Approaching Roadway Width: 17.0m (55.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb-To-Curb Width: 24.1m (79.1ft),  Out-to-Out Width: 25.2m (82.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 74.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 44.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11277,  Location: IN TAYLOR (Lat: 42.227358,  Lng: -83.268953),  Route carried "on" structure: US 24,  Year Built: 1986,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 29,303 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 34,838 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: SEXTON KILFOIL DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 15.363,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 470,  Subroute: 38),  Owner: State Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 19.6m (64.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 59.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11278,  Location: IN TAYLOR (Lat: 42.227414,  Lng: -83.269408),  Route carried "on" structure: US 24,  Year Built: 1964,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 29,303 (year 2007),  Truck Traffic: 4%,  Average Future Daily Traffic: 34,838 (year 2018),  Design Load: HS 20,  Features Intersected: SEXTON KILFOIL DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.289,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 157,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 10.8m (35.4ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.6m (34.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 14.5m (47.6ft),  Out-to-Out Width: 16.7m (54.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 80.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11281,  Location: IN TAYLOR (Lat: 42.198772,  Lng: -83.268281),  Route carried "on" structure: US 24,  Year Built: 1964,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 0.75m (2.46ft),  Average Daily Traffic: 22,172 (year 2007),  Truck Traffic: 6%,  Average Future Daily Traffic: 24,647 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: FRANK & POET DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.107,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 157,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 14.4m (47.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.5m (24.6ft),  Curb or Sidewalk Widths: Left: 3.9m (12.8ft),  Right: 0.0m,  Curb-To-Curb Width: 15.5m (50.9ft),  Out-to-Out Width: 20.1m (65.9ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Fair,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 68.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Total Project Cost: $178,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11284,  Location: 4.5 MI N OF FLAT ROCK (Lat: 42.178556,  Lng: -83.267042),  Route carried "on" structure: US 24,  Year Built: 1935,  Year Reconstructed: 1983,  Status: Open,  Structure Length: 5.03m (16.50ft),  Average Daily Traffic: 23,232 (year 2007),  Truck Traffic: 2%,  Average Future Daily Traffic: 23,438 (year 2018),  Design Load: H 20,  Features Intersected: CONRAIL
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.925,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 470,  Subroute: 38),  Owner: State Highway Agency,  Approaching Roadway Width: 18.2m (59.7ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 17.3m (56.8ft),  Curb-To-Curb Width: 17.6m (57.7ft),  Out-to-Out Width: 18.8m (61.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 81.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: August 2021,  Other Special Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11625,  Location: 0.2 MI S OF TAYLOR (Lat: 42.182650,  Lng: -83.243900),  Route carried "on" structure: Interstate 75,  Year Built: 1964,  Year Reconstructed: 2018,  Status: Open,  Structure Length: 1.26m (4.13ft),  Average Daily Traffic: 46,853 (year 2015),  Truck Traffic: 20%,  Average Future Daily Traffic: 52,548 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: BLAKELY DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 12.981,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 159,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 22.4m (73.5ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 23.6m (77.4ft),  Out-to-Out Width: 24.6m (80.7ft)

Condition: Deck: Excellent,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 47.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11626,  Location: 0.2 MI S OF TAYLOR (Lat: 42.182361,  Lng: -83.243217),  Route carried "on" structure: Interstate 75,  Year Built: 1964,  Year Reconstructed: 2019,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 46,853 (year 2015),  Truck Traffic: 20%,  Average Future Daily Traffic: 52,548 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: BLAKELY DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 12.977,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 159,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.4m (37.4ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 19.3m (63.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 80.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 48.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11629,  Location: IN TAYLOR (Lat: 42.195714,  Lng: -83.239708),  Route carried "on" structure: Ramp Interstate 75,  Year Built: 1966,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 40,584 (year 2005),  Truck Traffic: 16%,  Average Future Daily Traffic: 43,839 (year 2025),  Design Load: HS 20,  Features Intersected: FRANK & POET DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.246,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.9m (12.8ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 21.4m (70.2ft)

Condition: Channel: Fair,  Culverts: Good,  Operating Rating: 36.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1163,  Location: IN TAYLOR (Lat: 42.195828,  Lng: -83.240278),  Route carried "on" structure: Interstate 75,  Year Built: 1966,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 83,412 (year 2007),  Truck Traffic: 19%,  Average Future Daily Traffic: 74,095 (year 2018),  Design Load: HS 20,  Features Intersected: FRANK & POET DRAIN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 14.502,  Lanes on structure: 7,  Base Highway Network: Yes (Inventory Route: 159,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 16.5m (54.1ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.9m (12.8ft),  Curb-To-Curb Width: 16.5m (54.1ft),  Out-to-Out Width: 42.0m (137.8ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 11635,  Location: S OF EUREKA (Lat: 42.197278,  Lng: -83.235083),  Route carried "on" structure: Ramp City street ,  Year Built: 1965,  Status: Open,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 1,750 (year 2006),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,013 (year 2026),  Design Load: HS 20,  Features Intersected: FRANK & POET DRAIN,  Facility Carried by Structure: HURON STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.269,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.4m (17.7ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 79.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 78.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.93m (26.02ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Bridge Improvement Cost: $224,000,  Roadway Improvement Cost: $22,000,  Total Project Cost: $263,000
Find on map >>   Show street view

Structure Number: 1164,  Location: IN TAYLOR (Lat: 42.203750,  Lng: -83.233644),  Route carried "on" structure: Interstate 75,  Year Built: 1965,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 6.50m (21.33ft),  Average Daily Traffic: 46,853 (year 2015),  Truck Traffic: 20%,  Average Future Daily Traffic: 52,548 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: GTW RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 15.552,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 159,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.1m (75.8ft),  Curb-To-Curb Width: 15.7m (51.5ft),  Out-to-Out Width: 16.6m (54.5ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 61.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11641,  Location: IN TAYLOR (Lat: 42.204100,  Lng: -83.233661),  Route carried "on" structure: Interstate 75,  Year Built: 1965,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 6.50m (21.33ft),  Average Daily Traffic: 46,853 (year 2015),  Truck Traffic: 20%,  Average Future Daily Traffic: 52,548 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: GTW RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 15.589,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 159,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 16.4m (53.8ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.1m (75.8ft),  Curb-To-Curb Width: 15.7m (51.5ft),  Out-to-Out Width: 16.6m (54.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 61.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11653,  Location: 0.8 MI S OF TAYLOR (Lat: 42.170556,  Lng: -83.243092),  Route carried "on" structure: County highway 2057,  Year Built: 2006,  Status: Open,  Structure Length: 6.10m (20.01ft),  Average Daily Traffic: 21,800 (year 2005),  Truck Traffic: 4%,  Average Future Daily Traffic: 51,600 (year 2026),  Design Load: HS 25 or greater,  Features Intersected: I-75,  Facility Carried by Structure: SIBLEY RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 13.266,  Lanes on structure: 5,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.0m (98.4ft),  Curb-To-Curb Width: 24.4m (80.1ft),  Out-to-Out Width: 25.4m (83.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 76.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11654,  Location: S LTS OF TAYLOR (Lat: 42.183978,  Lng: -83.243261),  Route carried "on" structure: County highway 2057,  Year Built: 1964,  Status: Open,  Structure Length: 10.69m (35.07ft),  Average Daily Traffic: 40,584 (year 2005),  Truck Traffic: 5%,  Average Future Daily Traffic: 43,839 (year 2025),  Design Load: H 20,  Features Intersected: I-75,  Facility Carried by Structure: PENNSYLVANIA RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 14.309,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 25.1m (82.3ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.7m (35.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 69.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11655,  Location: IN TAYLOR OVER US-24 CONN (Lat: 42.187711,  Lng: -83.244086),  Route carried "on" structure: Interstate 75,  Year Built: 1964,  Year Reconstructed: 2018,  Status: Open,  Structure Length: 5.81m (19.06ft),  Average Daily Traffic: 46,853 (year 2015),  Truck Traffic: 20%,  Average Future Daily Traffic: 52,548 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: US-24 CONN
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 13.545,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 159,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 18.3m (60.0ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.2m (79.4ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 19.3m (63.3ft)

Condition: Deck: Excellent,  Superstructure: Good,  Substructure: Good,  Operating Rating: 69.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11656,  Location: IN TAYLOR OVER EUREKA RD (Lat: 42.198314,  Lng: -83.239156),  Route carried "on" structure: Interstate 75,  Year Built: 1966,  Year Reconstructed: 2019,  Status: Open,  Structure Length: 7.00m (22.97ft),  Average Daily Traffic: 46,853 (year 2015),  Truck Traffic: 20%,  Average Future Daily Traffic: 52,548 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: EUREKA RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 14.794,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 159,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 23.5m (77.1ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.7m (81.0ft),  Curb-To-Curb Width: 23.8m (78.1ft),  Out-to-Out Width: 24.8m (81.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 59.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11657,  Location: IN TAYLOR OVER EUREKA RD (Lat: 42.198303,  Lng: -83.239528),  Route carried "on" structure: Interstate 75,  Year Built: 1966,  Year Reconstructed: 2018,  Status: Open,  Structure Length: 6.96m (22.83ft),  Average Daily Traffic: 46,853 (year 2015),  Truck Traffic: 20%,  Average Future Daily Traffic: 52,548 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: EUREKA RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 14.781,  Lanes on structure: 3,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 159,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.6m (80.7ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 19.3m (63.3ft)

Condition: Deck: Excellent,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 85.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11879,  Location: IN TAYLOR (Lat: 42.190494,  Lng: -83.253761),  Route carried "on" structure: Alternate US 24,  Year Built: 1963,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 5.54m (18.18ft),  Average Daily Traffic: 9,440 (year 2007),  Truck Traffic: 11%,  Average Future Daily Traffic: 9,227 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: CONRAIL
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.144,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 157,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.4m (60.4ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 81.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 11 months,  Inspection Date: November 2021,  Other Special Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1188,  Location: IN TAYLOR (Lat: 42.190211,  Lng: -83.254103),  Route carried "on" structure: Alternate US 24,  Year Built: 1963,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 5.54m (18.18ft),  Average Daily Traffic: 9,440 (year 2007),  Truck Traffic: 11%,  Average Future Daily Traffic: 9,227 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: CONRAIL
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.139,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 157,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.4m (60.4ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 81.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 6 months,  Inspection Date: November 2021,  Other Special Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 11881,  Location: IN TAYLOR OVER RACHO RD (Lat: 42.189158,  Lng: -83.247819),  Route carried "on" structure: Alternate US 24,  Year Built: 1964,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 4.36m (14.30ft),  Average Daily Traffic: 9,440 (year 2007),  Truck Traffic: 11%,  Average Future Daily Traffic: 9,227 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: RACHO RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.595,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 157,  Subroute: 9),  Owner: State Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Good,  Operating Rating: 60.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Discuss Taylor, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.