Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Lapeer, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 56Number of bridges
  • 358ft / 109mTotal length
  • $810,000Total costs
  • 515,575Total average daily traffic
  • 63,245Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Lapeer
  • No street view available for this location

New bridges in Lapeer, MI - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 21930-1939
  • 11940-1949
  • 21950-1959
  • 31960-1969
  • 181970-1979
  • 171980-1989
  • 81990-1999
  • 12000-2009
  • 32010-2019
Reconstructed bridges in Lapeer, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11980-1989
  • 11990-1999
  • 12000-2009
  • 12010-2019
Average Bridge Daily Traffic in Lapeer, MI
Average Bridge Truck Traffic in Lapeer, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 15.8%Very good
  • 36.8%Good
  • 31.6%Satisfactory
  • 5.3%Fair
  • 7.9%Poor
  • 2.6%Serious
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 21.1%Very good
  • 26.3%Good
  • 18.4%Satisfactory
  • 26.3%Fair
  • 5.3%Poor
  • 2.6%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 31.6%Very good
  • 34.2%Good
  • 21.1%Satisfactory
  • 13.2%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 29.7%Very good
  • 51.4%Good
  • 13.5%Satisfactory
  • 2.7%Fair
  • 2.7%Poor
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 25.0%Very good
  • 62.5%Good
  • 12.5%Satisfactory
Find on map >>   Show street view

Structure Number: 53,  Location: 6.2 MI S OF GRAND MARAIS (Lat: 46.589900,  Lng: -86.008808),  Route carried "on" structure: State highway 77,  Year Built: 1928,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 406 (year 2007),  Truck Traffic: 14%,  Average Future Daily Traffic: 651 (year 2018),  Design Load: H 15,  Features Intersected: W BR SUCKER RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.158,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 113,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 63.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1265,  Location: 3.2 MI E OF M-66 (Lat: 42.287058,  Lng: -85.120475),  Route carried "on" structure: Interstate 94,  Year Built: 1959,  Status: Open,  Structure Length: 3.57m (11.71ft),  Average Daily Traffic: 22,400 (year 2010),  Truck Traffic: 23%,  Average Future Daily Traffic: 29,282 (year 2030),  Design Load: HS 20,  Features Intersected: 9 MILE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 15.540,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 129,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 11.7m (38.4ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.5m (44.3ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 61.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Other Special Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 53,  Location: 0.1 MI S OF W GENESEE ST (Lat: 43.049269,  Lng: -83.318511),  Route carried "on" structure: State highway 24,  Year Built: 2015,  Status: Open,  Structure Length: 1.33m (4.36ft),  Average Daily Traffic: 28,600 (year 2013),  Truck Traffic: 3%,  Average Future Daily Traffic: 31,600 (year 2033),  Design Load: Greater than HL93,  Features Intersected: FARMER'S CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 18.722,  Lanes on structure: 5,  Owner: State Highway Agency,  Approaching Roadway Width: 19.8m (65.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft),  Curb or Sidewalk Widths: Left: 0.8m (2.6ft),  Right: 0.8m (2.6ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 33.1m (108.6ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 87.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 67.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5301,  Location: 1.8 MI N OF M-21 (Lat: 43.080733,  Lng: -83.310192),  Route carried "on" structure: State highway 24,  Year Built: 1948,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 18,440 (year 2007),  Truck Traffic: 3%,  Average Future Daily Traffic: 26,109 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: S BR FLINT RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 22.392,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.7m (61.4ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 13.8m (45.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 70.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5302,  Location: 2.8 MI N OF M-21 (Lat: 43.091672,  Lng: -83.307692),  Route carried "on" structure: State highway 24,  Year Built: 2012,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 18,300 (year 2012),  Truck Traffic: 3%,  Average Future Daily Traffic: 20,200 (year 2032),  Design Load: Greater than HL93,  Features Intersected: PLUM CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 23.655,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 75,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 51.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5322,  Location: IN LAPEER (OLD M-21) (Lat: 43.050925,  Lng: -83.304039),  Route carried "on" structure: City street ,  Year Built: 1997,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 14,458 (year 1999),  Truck Traffic: 4%,  Average Future Daily Traffic: 16,627 (year 2014),  Design Load: HS 20,  Features Intersected: S BR FLINT R,  Facility Carried by Structure: E IMLAY CITY RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 13.860,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 22.6m (74.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.7m (31.8ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 23.3m (76.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 75.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5324,  Location: 1.0 MI SW OF LAPEER (Lat: 43.030950,  Lng: -83.349019),  Route carried "on" structure: Interstate 69,  Year Built: 1971,  Status: Open,  Structure Length: 3.36m (11.02ft),  Average Daily Traffic: 13,176 (year 2007),  Truck Traffic: 22%,  Average Future Daily Traffic: 17,095 (year 2018),  Design Load: HS 20,  Features Intersected: FARMERS CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.227,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 75,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 83.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 5325,  Location: 1.0 MI SW OF LAPEER (Lat: 43.031358,  Lng: -83.348906),  Route carried "on" structure: Interstate 69,  Year Built: 1971,  Status: Open,  Structure Length: 3.36m (11.02ft),  Average Daily Traffic: 13,176 (year 2007),  Truck Traffic: 22%,  Average Future Daily Traffic: 17,095 (year 2018),  Design Load: HS 20,  Features Intersected: FARMERS CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.233,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 75,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Fair,  Channel: Good,  Operating Rating: 83.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 533,  Location: 3.0 MI SW OF LAPEER (Lat: 43.031167,  Lng: -83.361469),  Route carried "on" structure: County highway 4421,  Year Built: 1971,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 8.05m (26.41ft),  Average Daily Traffic: 9,540 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 10,971 (year 2035),  Design Load: H 20,  Features Intersected: I-69,  Facility Carried by Structure: LAKE NEPESSING RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.197,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.5m (41.0ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 39.6m (129.9ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 65.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5332,  Location: 1.0 MI S OF LAPEER , M-24 (Lat: 43.024283,  Lng: -83.322511),  Route carried "on" structure: Interstate 69,  Year Built: 1971,  Status: Open,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 13,176 (year 2007),  Truck Traffic: 18%,  Average Future Daily Traffic: 14,061 (year 2018),  Design Load: HS 20,  Features Intersected: M-24
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.539,  Lanes on structure: 3,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 75,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 14.5m (47.6ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 26.5m (86.9ft),  Curb-To-Curb Width: 14.8m (48.6ft),  Out-to-Out Width: 16.0m (52.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 5335,  Location: SE OF LAPEER (Lat: 43.011786,  Lng: -83.265536),  Route carried "on" structure: Interstate 69,  Year Built: 1983,  Status: Open,  Structure Length: 4.20m (13.78ft),  Average Daily Traffic: 12,398 (year 2007),  Truck Traffic: 18%,  Average Future Daily Traffic: 14,061 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: S BR FLINT RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 16.591,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 75,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.5m (64.0ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 52.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5337,  Location: S OF LAPEER (Lat: 43.024750,  Lng: -83.316256),  Route carried "on" structure: Interstate 69,  Year Built: 1983,  Status: Open,  Structure Length: 3.75m (12.30ft),  Average Daily Traffic: 12,398 (year 2007),  Truck Traffic: 18%,  Average Future Daily Traffic: 14,061 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: HUNTER CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 12.046,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 75,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 21.6m (70.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 20.3m (66.6ft),  Out-to-Out Width: 21.5m (70.5ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 75.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5339,  Location: 0.2 MI E OF WILDER RD (Lat: 43.009836,  Lng: -83.240986),  Route carried "on" structure: Interstate 69,  Year Built: 1983,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 22,572 (year 2007),  Truck Traffic: 17%,  Average Future Daily Traffic: 39,025 (year 2018),  Design Load: HS 20+Mod,  Features Intersected: PINE CREEK
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 18.608,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 75,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft),  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 25.5m (83.7ft)

Condition: Channel: Poor,  Culverts: Good,  Operating Rating: 58.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5344,  Location: 1.0 MI S OF LAPEER (Lat: 43.023075,  Lng: -83.302711),  Route carried "on" structure: Interstate 69,  Year Built: 1983,  Status: Open,  Structure Length: 2.99m (9.81ft),  Average Daily Traffic: 9,991 (year 2013),  Truck Traffic: 18%,  Average Future Daily Traffic: 11,489 (year 2033),  Design Load: HS 25 or greater,  Features Intersected: CLARK RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 13.173,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 75,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.8m (94.5ft),  Curb-To-Curb Width: 13.5m (44.3ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Very good,  Operating Rating: 86.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5345,  Location: 1.0 MI S OF LAPEER (Lat: 43.023450,  Lng: -83.302742),  Route carried "on" structure: Interstate 69,  Year Built: 1983,  Status: Open,  Structure Length: 2.99m (9.81ft),  Average Daily Traffic: 9,991 (year 2013),  Truck Traffic: 18%,  Average Future Daily Traffic: 11,489 (year 2033),  Design Load: HS 25 or greater,  Features Intersected: CLARK RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 13.167,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 75,  Subroute: 10),  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.8m (94.5ft),  Curb-To-Curb Width: 13.5m (44.3ft),  Out-to-Out Width: 14.7m (48.2ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 86.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5346,  Location: 0.7 MI E OF LAPEER (Lat: 43.012808,  Lng: -83.282550),  Route carried "on" structure: County highway ,  Year Built: 1983,  Status: Open,  Structure Length: 9.14m (29.99ft),  Average Daily Traffic: 1,090 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,500 (year 2016),  Design Load: HS 20,  Features Intersected: I-69,  Facility Carried by Structure: MORRIS RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.977,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.2m (36.7ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 45.7m (149.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 63.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5347,  Location: 3.0 MI E OF LAPEER (Lat: 43.009550,  Lng: -83.243322),  Route carried "on" structure: County highway 4445,  Year Built: 1983,  Status: Open,  Structure Length: 8.29m (27.20ft),  Average Daily Traffic: 1,870 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,500 (year 2016),  Design Load: HS 20,  Features Intersected: I-69,  Facility Carried by Structure: WILDER RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.131,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 40.8m (133.9ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5369,  Location: SEC 23-26 LAPEER TWP (Lat: 43.001125,  Lng: -83.252603),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 1,887 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 2,303 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: SOUTH BR FLINT RIVER,  Facility Carried by Structure: NEWARK ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.589,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 84.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 50.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 537,  Location: SEC. 13-24 ELBA TWP. (Lat: 43.013981,  Lng: -83.351108),  Route carried "on" structure: County highway 4430,  Year Built: 1963,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 2,309 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,817 (year 2040),  Design Load: H 15,  Features Intersected: FARMERS CREEK,  Facility Carried by Structure: LIPPINCOTT ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.064,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 53.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 5372,  Location: SEC. 11 ELBA TWP. (Lat: 43.038997,  Lng: -83.375911),  Route carried "on" structure: County highway 4432,  Year Built: 2003,  Status: Posted for load,  Structure Length: 6.43m (21.10ft),  Average Daily Traffic: 2,007 (year 2020),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,449 (year 2040),  Design Load: HS 20,  Features Intersected: CN NORTH AMERICA,  Facility Carried by Structure: GENESEE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.258,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.1m (79.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 36.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 22.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5373,  Location: SEC. 21-28 MAYFIELD TWP. (Lat: 43.087858,  Lng: -83.295617),  Route carried "on" structure: County highway 4448,  Year Built: 1976,  Status: Open,  Structure Length: 1.06m (3.48ft),  Average Daily Traffic: 2,713 (year 2020),  Average Future Daily Traffic: 3,310 (year 2040),  Design Load: H 20,  Features Intersected: PLUM CREEK DRAIN,  Facility Carried by Structure: DALEY ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.964,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.6m (11.8ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 58.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 5388,  Location: SEC. 5 ELBA TWP. (Lat: 43.042297,  Lng: -83.422992),  Route carried "on" structure: County highway 4434,  Year Built: 1993,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 5,780 (year 2020),  Average Future Daily Traffic: 7,053 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: HASLER CREEK DRAIN,  Facility Carried by Structure: DAVISON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.941,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.2m (36.7ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 45.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 26.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5389,  Location: SEC. 28-29 MAYFIELD TWP. (Lat: 43.078714,  Lng: -83.306794),  Route carried "on" structure: County highway 4433,  Year Built: 1935,  Year Reconstructed: 2021,  Status: Open,  Structure Length: 1.26m (4.13ft),  Average Daily Traffic: 5,200 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 9,392 (year 2041),  Design Load: H 15,  Features Intersected: SOUTH BR. FLINT RIVER,  Facility Carried by Structure: SAGINAW ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 12.174,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.2m (36.7ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 52.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 40.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 22 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 539,  Location: SEC. 11-12 LAPEER TWP. (Lat: 43.041178,  Lng: -83.245197),  Route carried "on" structure: County highway 4445,  Year Built: 2017,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 3,415 (year 2019),  Average Future Daily Traffic: 4,167 (year 2039),  Design Load: H 20,  Features Intersected: PINE CREEK DRAIN,  Facility Carried by Structure: WILDER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.646,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Aluminum, Iron,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Out-to-Out Width: 18.4m (60.4ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 45.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 5421,  Location: SEC. 35 ELBA TWP. (Lat: 42.977314,  Lng: -83.362514),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1985,  Status: Posted for load,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 25 (year 2020),  Truck Traffic: 6%,  Average Future Daily Traffic: 31 (year 2040),  Design Load: HS 20,  Features Intersected: FARMERS CREEK,  Facility Carried by Structure: MITCHELL ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.325,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 40.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 27.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Other
Find on map >>   Show street view

Structure Number: 5433,  Location: SEC. 14-23 LAPEER TWP. (Lat: 43.015486,  Lng: -83.259825),  Route carried "on" structure: County highway ,  Year Built: 1981,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 215 (year 2018),  Average Future Daily Traffic: 262 (year 2038),  Design Load: HS 20,  Features Intersected: SOUTH BR. FLINT RIVER,  Facility Carried by Structure: GREENWOOD ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.859,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.5m (37.7ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 56.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5434,  Location: SEC. 15 LAPEER TWP. (Lat: 43.022461,  Lng: -83.265292),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1977,  Status: Temporarily open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 420 (year 2005),  Average Future Daily Traffic: 750 (year 2027),  Design Load: HS 20,  Features Intersected: SOUTH BR. FLINT RIVER,  Facility Carried by Structure: HIGLEY ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.121,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.4m (24.3ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Good,  Operating Rating: 59.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5435,  Location: SEC. 10 LAPEER TWP. (Lat: 43.036961,  Lng: -83.277978),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1991,  Status: Posted for load,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 616 (year 2020),  Average Future Daily Traffic: 752 (year 2040),  Design Load: HS 20,  Features Intersected: SOUTH BR. FLINT RIVER,  Facility Carried by Structure: PEPPERMILL ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.489,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 44.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 26.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5436,  Location: SEC. 4-9 LAPEER TWP. (Lat: 43.044025,  Lng: -83.287550),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1982,  Status: Open,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 4,300 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,247 (year 2039),  Design Load: HS 20,  Features Intersected: SOUTH BR. FLINT RIVER,  Facility Carried by Structure: PEPPERMILL ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.345,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 5437,  Location: SEC. 9-10 LAPEER TWP. (Lat: 43.043086,  Lng: -83.284453),  Route carried "on" structure: County highway ,  Year Built: 1967,  Status: Posted for load,  Structure Length: 1.09m (3.58ft),  Average Daily Traffic: 4,300 (year 2019),  Average Future Daily Traffic: 5,247 (year 2039),  Design Load: H 20,  Features Intersected: SOUTH BR. FLINT RIVER,  Facility Carried by Structure: MORRIS ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.364,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.6m (34.8ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.3m (24.0ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 26.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 15.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 5442,  Location: SEC. 29 MAYFIELD TWP. (Lat: 43.082028,  Lng: -83.316989),  Route carried "on" structure: County highway ,  Year Built: 1988,  Status: Posted for load,  Structure Length: 3.90m (12.80ft),  Average Daily Traffic: 1,594 (year 2020),  Average Future Daily Traffic: 1,945 (year 2040),  Design Load: HS 20,  Features Intersected: SOUTH BR. FLINT RIVER,  Facility Carried by Structure: MAYFIELD ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.077,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 9.7m (31.8ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 17.2 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 12.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5443,  Location: SEC. 27 MAYFIELD TWP. (Lat: 43.085597,  Lng: -83.277628),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1976,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 695 (year 2019),  Average Future Daily Traffic: 848 (year 2039),  Design Load: H 20,  Features Intersected: PLUM CREEK DRAIN,  Facility Carried by Structure: ROODS LAKE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.924,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.3m (10.8ft),  Out-to-Out Width: 17.1m (56.1ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 87.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 5444,  Location: SEC 19 MAYFIELD TWP (Lat: 43.092247,  Lng: -83.345108),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1978,  Status: Open,  Structure Length: 2.77m (9.09ft),  Average Daily Traffic: 2,320 (year 2019),  Average Future Daily Traffic: 2,831 (year 2039),  Design Load: HS 20,  Features Intersected: SOUTH BR FLINT RIVER,  Facility Carried by Structure: MILLVILLE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.690,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 13.4m (44.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 64.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5446,  Location: SEC. 21 MAYFIELD TWP. (Lat: 43.088967,  Lng: -83.297658),  Route carried "on" structure: ServiceCounty highway ,  Year Built: 1976,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 2,150 (year 2019),  Average Future Daily Traffic: 2,623 (year 2039),  Design Load: H 20,  Features Intersected: PLUM CREEK DRAIN,  Facility Carried by Structure: FARNSWORTH ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.367,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.9m (25.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021
Find on map >>   Show street view

Structure Number: 5481,  Location: 3265 FT EAST OF M24 JUNCT (Lat: 43.055850,  Lng: -83.307850),  Route carried "on" structure: City street 2048,  Year Built: 1973,  Status: Open,  Structure Length: 1.64m (5.38ft),  Average Daily Traffic: 5,850 (year 1987),  Truck Traffic: 7%,  Average Future Daily Traffic: 10,565 (year 2007),  Design Load: HS 20+Mod,  Features Intersected: FLINT RIVER,  Facility Carried by Structure: NEPESSING STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.098,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.8m (51.8ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 0.0m,  Curb-To-Curb Width: 13.7m (44.9ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 70.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 5482,  Location: 3280 FT EAST OF M24 JUNCT (Lat: 43.058367,  Lng: -83.306650),  Route carried "on" structure: City street 2048,  Year Built: 1975,  Status: Open,  Structure Length: 1.64m (5.38ft),  Average Daily Traffic: 3,618 (year 1987),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,534 (year 2007),  Design Load: HS 20+Mod,  Features Intersected: FLINT RIVER,  Facility Carried by Structure: OREGON STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 12.428,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.8m (51.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Very good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 5483,  Location: 250 FT SOUTH OF M-21 JUNC (Lat: 43.050214,  Lng: -83.313847),  Route carried "on" structure: City street 2048,  Year Built: 1978,  Status: Posted for load,  Structure Length: 1.82m (5.97ft),  Average Daily Traffic: 1,010 (year 1987),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,824 (year 2007),  Design Load: HS 20+Mod,  Features Intersected: FARMERS CREEK,  Facility Carried by Structure: BENTLEY STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.505,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.0m (55.8ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Serious,  Superstructure: Serious,  Substructure: Very good,  Channel: Good,  Operating Rating: 34.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 20.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 5484,  Location: 400 FEET NORTH OF M21 JUN (Lat: 43.051722,  Lng: -83.312261),  Route carried "on" structure: City street ,  Year Built: 1995,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 1,076 (year 1983),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,076 (year 2003),  Design Load: HS 20,  Features Intersected: FARMERS CREEK,  Facility Carried by Structure: MASON STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.124,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.0m (45.9ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 14.3m (46.9ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 77.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 46.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 5485,  Location: 350 FT NORTH OF M21 JUNCT (Lat: 43.051692,  Lng: -83.310914),  Route carried "on" structure: City street ,  Year Built: 1983,  Status: Open,  Structure Length: 1.82m (5.97ft),  Average Daily Traffic: 737 (year 1983),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,331 (year 2003),  Design Load: HS 20+Mod,  Features Intersected: FARMERS CREEK,  Facility Carried by Structure: FOX STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.122,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.6m (57.7ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Channel: Very good,  Operating Rating: 56.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Discuss Lapeer, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.