Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Mountain View, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 92Number of bridges
  • 1,135ft / 346mTotal length
  • $3,121,000Total costs
  • 4,624,873Total average daily traffic
  • 184,706Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Mountain View
  • No street view available for this location

New bridges in Mountain View, CA - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 21920-1929
  • 21930-1939
  • 31950-1959
  • 411960-1969
  • 41970-1979
  • 51980-1989
  • 121990-1999
  • 182000-2009
  • 42010-2019
Reconstructed bridges in Mountain View, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11940-1949
  • 01950-1959
  • 11960-1969
  • 21970-1979
  • 31980-1989
  • 51990-1999
  • 12000-2009
Average Bridge Daily Traffic in Mountain View, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 41.3%Good
  • 23.9%Satisfactory
  • 30.4%Fair
  • 4.3%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 78.3%Good
  • 6.5%Satisfactory
  • 15.2%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 95.7%Good
  • 2.2%Satisfactory
  • 2.2%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 4.2%Excellent
  • 54.2%Very good
  • 12.5%Good
  • 20.8%Satisfactory
  • 8.3%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 25.0%Satisfactory
  • 25.0%Poor
Find on map >>   Show street view

Structure Number: 37 0014,  Location: 04-SCL-082-18.96-MVW (Lat: 37.378828,  Lng: -122.069775),  Route carried "on" structure: State highway 82,  Year Built: 1907,  Year Reconstructed: 1965,  Status: Open,  Structure Length: 1.71m (5.61ft),  Average Daily Traffic: 49,000 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 87,584 (year 2036),  Design Load: H 15,  Features Intersected: STEVENS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.960,  Lanes on structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 29.0m (95.1ft),  Skew: 24 degrees,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 21.0m (68.9ft),  Out-to-Out Width: 30.1m (98.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 67.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37 0034,  Location: 04-SCL-101-48.04-MVW (Lat: 37.408356,  Lng: -122.068314),  Route carried "on" structure: US 101,  Year Built: 1932,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 155,000 (year 2009),  Truck Traffic: 3%,  Average Future Daily Traffic: 221,268 (year 2040),  Design Load: HS 20,  Features Intersected: STEVENS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 48.040,  Lanes on structure: 10,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 59.5m (195.2ft),  Skew: 32 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 59.5m (195.2ft),  Out-to-Out Width: 61.0m (200.1ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 24.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37 0072,  Location: 04-SCL-101-47.01-MVW (Lat: 37.404236,  Lng: -122.051028),  Route carried "on" structure: US 101,  Year Built: 1961,  Year Reconstructed: 1989,  Status: Open,  Structure Length: 5.94m (19.49ft),  Average Daily Traffic: 155,000 (year 2009),  Truck Traffic: 3%,  Average Future Daily Traffic: 221,268 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: ELLIS STREET & VTA LRT
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 47.010,  Lanes on structure: 8,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 40.2m (131.9ft),  Skew: 32 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 40.2m (131.9ft),  Out-to-Out Width: 42.0m (137.8ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0080L,  Location: 04-SCL-237-R0.99-MVW (Lat: 37.387219,  Lng: -122.058236),  Route carried "on" structure: State highway 237,  Year Built: 1964,  Status: Open,  Structure Length: 12.86m (42.19ft),  Average Daily Traffic: 34,000 (year 2009),  Truck Traffic: 6%,  Average Future Daily Traffic: 49,799 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: CALTRAIN,UP RR,CENTRAL,
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.990,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 31.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 22.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0080R,  Location: 04-SCL-237-R0.99-MVW (Lat: 37.387122,  Lng: -122.057956),  Route carried "on" structure: State highway 237,  Year Built: 1981,  Status: Open,  Structure Length: 12.87m (42.22ft),  Average Daily Traffic: 34,000 (year 2009),  Truck Traffic: 6%,  Average Future Daily Traffic: 50,132 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: CALTRAIN,UP RR,CENTRAL,
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.990,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.7m (41.7ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 6,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0105,  Location: 04-SCL-101-47.89-MVW (Lat: 37.407331,  Lng: -122.066389),  Route carried "on" structure: City street C335,  Year Built: 1957,  Status: Open,  Structure Length: 5.01m (16.44ft),  Average Daily Traffic: 32,000 (year 1998),  Truck Traffic: 1%,  Average Future Daily Traffic: 46,833 (year 2042),  Design Load: HS 20,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: MOFFETT BOULEVARD
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 10,  Owner: State Highway Agency,  Approaching Roadway Width: 17.6m (57.7ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 17.6m (57.7ft),  Out-to-Out Width: 20.5m (67.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 39.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37 0143,  Location: 04-SCL-101-49.61-MVW (Lat: 37.420597,  Lng: -122.092544),  Route carried "on" structure: City street C321,  Year Built: 1961,  Status: Open,  Structure Length: 7.65m (25.10ft),  Average Daily Traffic: 15,000 (year 2009),  Truck Traffic: 1%,  Average Future Daily Traffic: 20,814 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: NB RENGSTORFF AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 10,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 26.2m (86.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 8.7m (28.5ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 46.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 26.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Length Of Structure Improvement: 7.65m (25.10ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Bridge Improvement Cost: $858,000,  Roadway Improvement Cost: $171,000,  Total Project Cost: $1,441,000 ( Estimate for 2020),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0153,  Location: 04-SCL-101-48.60-MVW (Lat: 37.411361,  Lng: -122.077894),  Route carried "on" structure: City street ,  Year Built: 1992,  Status: Open,  Structure Length: 11.40m (37.40ft),  Average Daily Traffic: 27,903 (year 1997),  Truck Traffic: 1%,  Average Future Daily Traffic: 43,039 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: N. SHORELINE BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 15,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.0m (82.0ft),  Skew: 22 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 57.3m (188.0ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 25.0m (82.0ft),  Out-to-Out Width: 35.3m (115.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0187,  Location: 04-SCL-085-R23.44-MVW (Lat: 37.402631,  Lng: -122.069694),  Route carried "on" structure: State highway 85,  Year Built: 1965,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 6.31m (20.70ft),  Average Daily Traffic: 72,000 (year 2012),  Truck Traffic: 2%,  Average Future Daily Traffic: 89,869 (year 2037),  Design Load: HS 20,  Features Intersected: MOFFETT BOULEVARD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.440,  Lanes on structure: 6,  Lanes under structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 40.0m (131.2ft),  Skew: 34 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.9m (62.0ft),  Curb-To-Curb Width: 39.6m (129.9ft),  Out-to-Out Width: 41.4m (135.8ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 56.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0189,  Location: 04-SCL-085-R20.96-MVW (Lat: 37.366969,  Lng: -122.063708),  Route carried "on" structure: State highway 85,  Year Built: 1965,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 115,000 (year 2012),  Truck Traffic: 3%,  Average Future Daily Traffic: 139,717 (year 2037),  Design Load: H 20,  Features Intersected: STEVENS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 20.960,  Lanes on structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 37.0m (121.4ft),  Skew: 39 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.3m (27.2ft),  Curb-To-Curb Width: 36.5m (119.8ft),  Out-to-Out Width: 38.1m (125.0ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Very good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 94.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 019,  Location: 04-SCL-280-5.95-SJS (Lat: 37.316872,  Lng: -121.975028),  Route carried "on" structure: City street C017,  Year Built: 1964,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 8.23m (27.00ft),  Average Daily Traffic: 49,000 (year 1998),  Truck Traffic: 2%,  Average Future Daily Traffic: 61,926 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: INTERSTATE 280,  Facility Carried by Structure: SARATOGA AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 9,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 32.0m (105.0ft),  Skew: 31 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 31.6m (103.7ft),  Out-to-Out Width: 34.4m (112.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0197,  Location: 04-SCL-085-R22.95-MVW (Lat: 37.395856,  Lng: -122.068389),  Route carried "on" structure: State highway 85,  Year Built: 1965,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 3.72m (12.20ft),  Average Daily Traffic: 115,000 (year 2012),  Truck Traffic: 3%,  Average Future Daily Traffic: 139,253 (year 2037),  Design Load: HS 20,  Features Intersected: STEVENS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.950,  Lanes on structure: 7,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 45.0m (147.6ft),  Skew: 39 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 44.6m (146.3ft),  Out-to-Out Width: 46.0m (150.9ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Fair,  Channel: Excellent,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 27.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0198,  Location: 04-SCL-085-R22.13-MVW (Lat: 37.383872,  Lng: -122.068036),  Route carried "on" structure: State highway 85,  Year Built: 1965,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 9.46m (31.04ft),  Average Daily Traffic: 115,000 (year 2012),  Truck Traffic: 3%,  Average Future Daily Traffic: 139,717 (year 2037),  Design Load: H 20,  Features Intersected: STATE ROUTE 237
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.130,  Lanes on structure: 8,  Lanes under structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 41.0m (134.5ft),  Skew: 32 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 20.1m (65.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 40.7m (133.5ft),  Out-to-Out Width: 43.2m (141.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 63.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0199F,  Location: 04-SCL-085-R22.20-MVW (Lat: 37.385317,  Lng: -122.069058),  Route carried "on" structure: Ramp State highway 85,  Year Built: 1965,  Status: Open,  Structure Length: 7.26m (23.82ft),  Average Daily Traffic: 3,600 (year 2012),  Truck Traffic: 2%,  Average Future Daily Traffic: 5,239 (year 2037),  Design Load: HS 20,  Features Intersected: STEVENS CREEK & TRAIL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.200,  Lanes on structure: 1,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 7.5m (24.6ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 8.0m (26.2ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 19.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 14.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0201F,  Location: 04-SCL-237-R0.32-MVW (Lat: 37.384075,  Lng: -122.069178),  Route carried "on" structure: Ramp State highway 237,  Year Built: 1965,  Status: Open,  Structure Length: 2.44m (8.01ft),  Average Daily Traffic: 16,600 (year 2001),  Truck Traffic: 3%,  Average Future Daily Traffic: 27,515 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: STEVENS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.320,  Lanes on structure: 1,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 7.9m (25.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 7.1m (23.3ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 65.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0201L,  Location: 04-SCL-237-R0.32-MVW (Lat: 37.383819,  Lng: -122.069106),  Route carried "on" structure: State highway 237,  Year Built: 1964,  Status: Open,  Structure Length: 2.53m (8.30ft),  Average Daily Traffic: 21,500 (year 2009),  Truck Traffic: 1%,  Average Future Daily Traffic: 42,098 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: STEVENS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.320,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.3m (37.1ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 11.3m (37.1ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0201R,  Location: 04-SCL-237-R0.32-MVW (Lat: 37.383542,  Lng: -122.069036),  Route carried "on" structure: State highway 237,  Year Built: 1964,  Status: Open,  Structure Length: 2.53m (8.30ft),  Average Daily Traffic: 21,500 (year 2009),  Truck Traffic: 1%,  Average Future Daily Traffic: 42,098 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: STEVENS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.320,  Lanes on structure: 3,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 17.1m (56.1ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 17.9m (58.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0204,  Location: 04-SCL-082-18.82-MVW (Lat: 37.378222,  Lng: -122.067311),  Route carried "on" structure: State highway 82,  Year Built: 1965,  Status: Open,  Structure Length: 7.38m (24.21ft),  Average Daily Traffic: 40,500 (year 2009),  Truck Traffic: 2%,  Average Future Daily Traffic: 86,302 (year 2042),  Design Load: HS 20,  Features Intersected: STATE ROUTE 85
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 18.820,  Lanes on structure: 8,  Lanes under structure: 8,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 33.0m (108.3ft),  Skew: 22 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.4m (80.1ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 31.9m (104.7ft),  Out-to-Out Width: 41.5m (136.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 41.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.38m (24.21ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0205,  Location: 04-SCL-237-R0.61-MVW (Lat: 37.385967,  Lng: -122.064947),  Route carried "on" structure: City street ,  Year Built: 1964,  Status: Open,  Structure Length: 7.62m (25.00ft),  Average Daily Traffic: 7,533 (year 2001),  Truck Traffic: 2%,  Average Future Daily Traffic: 9,652 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: STATE ROUTE 237 & RAMPS,  Facility Carried by Structure: DANA STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Skew: 21 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 20.6m (67.6ft),  Out-to-Out Width: 24.2m (79.4ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 33.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37 0207,  Location: 04-SCL-085-R22.63-MVW (Lat: 37.390850,  Lng: -122.068406),  Route carried "on" structure: State highway 85,  Year Built: 1965,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 13.30m (43.64ft),  Average Daily Traffic: 115,000 (year 2012),  Truck Traffic: 3%,  Average Future Daily Traffic: 139,717 (year 2037),  Design Load: HS 20,  Features Intersected: CALTRAIN,UP RR,CENTRAL,
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.630,  Lanes on structure: 6,  Lanes under structure: 10,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 33.5m (109.9ft),  Skew: 39 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 26.8m (87.9ft),  Curb-To-Curb Width: 33.2m (108.9ft),  Out-to-Out Width: 34.3m (112.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0213,  Location: 04-SCL-085-R23.19-MVW (Lat: 37.398875,  Lng: -122.069825),  Route carried "on" structure: City street D002,  Year Built: 1965,  Status: Open,  Structure Length: 5.88m (19.29ft),  Average Daily Traffic: 23,200 (year 2012),  Truck Traffic: 2%,  Average Future Daily Traffic: 36,184 (year 2037),  Design Load: HS 20,  Features Intersected: STATE ROUTE 85,  Facility Carried by Structure: MIDDLEFIELD ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 17.5m (57.4ft),  Skew: 32 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.0m (65.6ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 17.1m (56.1ft),  Out-to-Out Width: 21.3m (69.9ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 52.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0253,  Location: 04-SCL-085-R22.43-MVW (Lat: 37.388300,  Lng: -122.069575),  Route carried "on" structure: City street ,  Year Built: 1966,  Status: Open,  Structure Length: 12.46m (40.88ft),  Average Daily Traffic: 8,140 (year 2006),  Truck Traffic: 2%,  Average Future Daily Traffic: 13,053 (year 2042),  Design Load: H 20,  Features Intersected: STATE ROUTE 85 & RAMP,  Facility Carried by Structure: DANA STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Owner: State Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Skew: 33 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 18.9m (62.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 31.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 20.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 12.50m (41.01ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0440L,  Location: 04-SCL-085-4.50-SJS (Lat: 37.254822,  Lng: -121.845919),  Route carried "on" structure: State highway 85,  Year Built: 1990,  Status: Open,  Structure Length: 4.08m (13.39ft),  Average Daily Traffic: 51,500 (year 2009),  Truck Traffic: 1%,  Average Future Daily Traffic: 77,119 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: CAHALAN AVE (FUTURE)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.500,  Lanes on structure: 4,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 40.8m (133.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 20.5m (67.3ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0449,  Location: 04-SCL-101-49.61-MVW (Lat: 37.420617,  Lng: -122.092717),  Route carried "on" structure: City street C321,  Year Built: 1990,  Status: Open,  Structure Length: 7.70m (25.26ft),  Average Daily Traffic: 15,000 (year 1998),  Truck Traffic: 3%,  Average Future Daily Traffic: 21,518 (year 2044),  Design Load: HS 20,  Features Intersected: U.S. HIGHWAY 101,  Facility Carried by Structure: SB RENGSTORFF AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 10,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 26.2m (86.0ft),  Curb-To-Curb Width: 8.8m (28.9ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0547K,  Location: 04-SCL-101-48.28-MVW (Lat: 37.409378,  Lng: -122.072289),  Route carried "on" structure: Ramp US 101,  Year Built: 2005,  Status: Open,  Structure Length: 16.52m (54.20ft),  Average Daily Traffic: 6,400 (year 2001),  Truck Traffic: 7%,  Average Future Daily Traffic: 10,760 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SB 101-SB 85 CONNECTOR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 48.280,  Lanes on structure: 1,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 7.5m (24.6ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 47.0m (154.2ft),  Curb-To-Curb Width: 7.2m (23.6ft),  Out-to-Out Width: 8.1m (26.6ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0552,  Location: 04-SCL-237-M1.60-MVW (Lat: 37.392181,  Lng: -122.050092),  Route carried "on" structure: State highway 237,  Year Built: 1997,  Status: Open,  Structure Length: 6.01m (19.72ft),  Average Daily Traffic: 68,000 (year 2009),  Truck Traffic: 6%,  Average Future Daily Traffic: 100,264 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: MIDDLEFIELD ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.600,  Lanes on structure: 4,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 38.7m (127.0ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.3m (99.4ft),  Curb-To-Curb Width: 38.7m (127.0ft),  Out-to-Out Width: 40.4m (132.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: April 2019,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0553,  Location: 04-SCL-237-M1.80-MVW (Lat: 37.394506,  Lng: -122.046656),  Route carried "on" structure: State highway 237,  Year Built: 1997,  Status: Open,  Structure Length: 10.91m (35.79ft),  Average Daily Traffic: 68,000 (year 2009),  Truck Traffic: 6%,  Average Future Daily Traffic: 99,599 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: MAUDE AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.800,  Lanes on structure: 4,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 2,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Skew: 32 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 51.8m (169.9ft),  Curb-To-Curb Width: 34.1m (111.9ft),  Out-to-Out Width: 35.8m (117.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0572S,  Location: 04-SCL-085-R23.81-MVW (Lat: 37.408006,  Lng: -122.069403),  Route carried "on" structure: Ramp State highway 85,  Year Built: 2004,  Status: Open,  Structure Length: 19.00m (62.34ft),  Average Daily Traffic: 40,000 (year 2004),  Truck Traffic: 7%,  Average Future Daily Traffic: 53,798 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: U.S. HIGHWAY 101 & RAMPS
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.810,  Lanes on structure: 2,  Lanes under structure: 12,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.8m (35.4ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 72.0m (236.2ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 11.7m (38.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0573S,  Location: 04-SCL-101-48.97-MVW (Lat: 37.414583,  Lng: -122.082861),  Route carried "on" structure: Ramp US 101,  Year Built: 2005,  Status: Open,  Structure Length: 12.36m (40.55ft),  Average Daily Traffic: 8,000 (year 2001),  Truck Traffic: 5%,  Average Future Daily Traffic: 10,408 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: U.S. HIGHWAY 101
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 48.970,  Lanes on structure: 2,  Lanes under structure: 9,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 49.0m (160.8ft),  Curb-To-Curb Width: 10.8m (35.4ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2022,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0610E,  Location: 04-SCL-085-R23.83-MVW (Lat: 37.408131,  Lng: -122.070072),  Route carried "on" structure: Ramp State highway 85,  Year Built: 2006,  Status: Open,  Structure Length: 20.00m (65.62ft),  Average Daily Traffic: 64,000 (year 1998),  Truck Traffic: 6%,  Average Future Daily Traffic: 225,952 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: U.S. HWY 101 SB & RAMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.830,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 14.4m (47.2ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 80.0m (262.5ft),  Curb-To-Curb Width: 14.4m (47.2ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0611G,  Location: 04-SCL-085-R23.81-MVW (Lat: 37.407969,  Lng: -122.069717),  Route carried "on" structure: Ramp State highway 85,  Year Built: 2005,  Status: Open,  Structure Length: 21.70m (71.19ft),  Average Daily Traffic: 64,000 (year 1998),  Truck Traffic: 6%,  Average Future Daily Traffic: 225,952 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: U.S. HIGHWAY 101, SB RMP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.810,  Lanes on structure: 2,  Lanes under structure: 10,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.7m (38.4ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 63.0m (206.7ft),  Curb-To-Curb Width: 11.7m (38.4ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37 0673G,  Location: 04-SCL-280-5.34 (Lat: 37.318833,  Lng: -121.939111),  Route carried "on" structure: Ramp State highway 280,  Year Built: 2015,  Status: Open,  Structure Length: 15.51m (50.89ft),  Average Daily Traffic: 6,000 (year 2015),  Truck Traffic: 10%,  Average Future Daily Traffic: 12,000 (year 2039),  Design Load: HL 93,  Features Intersected: NB I-280 & I-880 OFFRAMP
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 5.340,  Lanes on structure: 1,  Lanes under structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 54.3m (178.1ft),  Curb-To-Curb Width: 10.3m (33.8ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0055,  Location: BTWN SR 85 & SR 82 (Lat: 37.382119,  Lng: -122.068961),  Route carried "on" structure: City street ,  Year Built: 1924,  Year Reconstructed: 1953,  Status: Open,  Structure Length: 1.83m (6.00ft),  Average Daily Traffic: 500 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 614 (year 2042),  Design Load: H 15,  Features Intersected: STEVENS CREEK,  Facility Carried by Structure: YUBA DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.8m (55.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Fair,  Operating Rating: 30.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 22.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0121,  Location: AT CENTRAL EXPWY (Lat: 37.396461,  Lng: -122.082253),  Route carried "on" structure: City street ,  Year Built: 1971,  Status: Open,  Structure Length: 12.15m (39.86ft),  Average Daily Traffic: 34,000 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 35,761 (year 2040),  Design Load: HS 20,  Features Intersected: UP RR,CENTRAL EXP,EVELYN,  Facility Carried by Structure: SHORELINE BLVD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 9,  Owner: County Highway Agency,  Approaching Roadway Width: 29.9m (98.1ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 30.4m (99.7ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 3.3m (10.8ft),  Curb-To-Curb Width: 28.0m (91.9ft),  Out-to-Out Width: 33.7m (110.6ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0122,  Location: AT CENTRAL EXPWY (Lat: 37.388758,  Lng: -122.063039),  Route carried "on" structure: City street ,  Year Built: 1967,  Status: Open,  Structure Length: 11.67m (38.29ft),  Average Daily Traffic: 11,000 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 12,000 (year 2040),  Design Load: HS 20,  Features Intersected: UP RR,CENTRAL EXP,EVELYN,  Facility Carried by Structure: S WHISMAN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: County Highway Agency,  Approaching Roadway Width: 18.9m (62.0ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 6,  Length of Maximum Span: 22.9m (75.1ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 1.7m (5.6ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 21.8m (71.5ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 69.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0123,  Location: AT CENTRAL EXPWY (Lat: 37.386381,  Lng: -122.046214),  Route carried "on" structure: City street ,  Year Built: 1971,  Status: Open,  Structure Length: 8.41m (27.59ft),  Average Daily Traffic: 14,000 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 15,813 (year 2040),  Design Load: HS 20,  Features Intersected: CENTRAL EXPRESSWAY,  Facility Carried by Structure: E MIDDLEFIELD ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 25.6m (84.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.6m (34.8ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 62.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 37C0175,  Location: JSP PRESTON DRIVE (Lat: 37.362889,  Lng: -122.077747),  Route carried "on" structure: City street ,  Year Built: 1959,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 18,000 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 20,471 (year 2042),  Features Intersected: PERMANENTE CREEK,  Facility Carried by Structure: GRANT ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0186L,  Location: NEAR SH 85 (Lat: 37.392167,  Lng: -122.069850),  Route carried "on" structure: County highway ,  Year Built: 1967,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 47,000 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 50,839 (year 2040),  Design Load: HS 20,  Features Intersected: STEVENS CREEK,  Facility Carried by Structure: CENTRAL EXPWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C0186R,  Location: NEAR SH 85 (Lat: 37.392392,  Lng: -122.069856),  Route carried "on" structure: County highway ,  Year Built: 1967,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 46,000 (year 2013),  Truck Traffic: 5%,  Average Future Daily Traffic: 48,806 (year 2040),  Design Load: HS 20,  Features Intersected: STEVENS CREEK,  Facility Carried by Structure: CENTRAL EXPWY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 37C022,  Location: E STEVENS CANYON RD (Lat: 37.312925,  Lng: -122.064042),  Route carried "on" structure: City street ,  Year Built: 1920,  Year Reconstructed: 1976,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 4,509 (year 2013),  Truck Traffic: 1%,  Average Future Daily Traffic: 7,309 (year 2040),  Features Intersected: STEVENS CREEK,  Facility Carried by Structure: MCCLELLAN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.1m (33.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 25.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 15.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Discuss Mountain View, California (CA) on our hugely popular California forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.