Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Rumford, Maine (ME)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 18Number of bridges
  • 305ft / 93.1mTotal length
  • 60,326Total average daily traffic
  • 3,298Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Rumford
  • No street view available for this location

New bridges in Rumford, ME - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 11920-1929
  • 21930-1939
  • 11940-1949
  • 41950-1959
  • 11960-1969
  • 11970-1979
  • 11980-1989
  • 22000-2009
  • 22010-2019
Reconstructed bridges in Rumford, ME - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 01960-1969
  • 01970-1979
  • 01980-1989
  • 21990-1999
  • 02000-2009
  • 12010-2019
Average Bridge Daily Traffic in Rumford, ME
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 23.1%Good
  • 7.7%Satisfactory
  • 30.8%Fair
  • 38.5%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 7.7%Very good
  • 7.7%Good
  • 30.8%Satisfactory
  • 30.8%Fair
  • 23.1%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 23.1%Good
  • 30.8%Satisfactory
  • 38.5%Fair
  • 7.7%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 35.7%Very good
  • 28.6%Good
  • 28.6%Satisfactory
  • 7.1%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 33.3%Very good
  • 33.3%Good
  • 33.3%Poor
Find on map >>   Show street view

Structure Number: 2585,  Location: 50 FT E'LY OF JCT RTE 2 (Lat: 44.543461,  Lng: -70.546561),  Route carried "on" structure: State highway 108,  Year Built: 1936,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 8.69m (28.51ft),  Average Daily Traffic: 7,203 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 10,084 (year 2036),  Design Load: H 15,  Features Intersected: ANDROSCOGGIN RIVER
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 42.792,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Arch - Thru,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 1,  Length of Maximum Span: 71.3m (233.9ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.6m (24.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 60 months,  Inspection Date: September 2021,  Critical Feature Inspection Date: September 2021,  Other Special Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 2707,  Location: 0.1 MI W JCT RTE 17 (Lat: 44.555489,  Lng: -70.546231),  Route carried "on" structure: State highway 2,  Year Built: 1952,  Status: Open,  Structure Length: 5.36m (17.59ft),  Average Daily Traffic: 10,165 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 14,231 (year 2036),  Design Load: H 20,  Features Intersected: SWIFT RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 57.100,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 26.8m (87.9ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 19.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 14.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Critical Feature Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 299,  Location: W'LY END ABUTTS US2 (Lat: 44.547619,  Lng: -70.547950),  Route carried "on" structure: County highway ,  Year Built: 1929,  Year Reconstructed: 1999,  Status: Open,  Structure Length: 22.80m (74.80ft),  Average Daily Traffic: 3,509 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,913 (year 2036),  Design Load: HS 20,  Features Intersected: ANDROSCOGGIN R. W CHANEL,  Facility Carried by Structure: PORTLAND STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.032,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 9,  Length of Maximum Span: 61.0m (200.1ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 14.0m (45.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Very good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 3056,  Location: 3.4 MI SW'LY OF JCT US2 (Lat: 44.505369,  Lng: -70.566439),  Route carried "on" structure: County highway ,  Year Built: 1933,  Status: Open,  Structure Length: 0.71m (2.33ft),  Average Daily Traffic: 545 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 872 (year 2036),  Design Load: H 15,  Features Intersected: MT ZIRCON BROOK,  Facility Carried by Structure: SOUTH RUMFORD ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.327,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 7.8m (25.6ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 38.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 29.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 3327,  Location: 50 FT S of US 2 (Lat: 44.549619,  Lng: -70.533981),  Route carried "on" structure: State highway ,  Year Built: 2000,  Status: Open,  Structure Length: 12.99m (42.62ft),  Average Daily Traffic: 6,182 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 8,655 (year 2036),  Design Load: HS 25 or greater,  Features Intersected: ANDROSCOGGIN RIVER,  Facility Carried by Structure: RAILROAD STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.354,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 53.5m (175.5ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 47.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 3638,  Location: 50 FT E OF JCT CANAL ST (Lat: 44.545811,  Lng: -70.544311),  Route carried "on" structure: City street ,  Year Built: 1942,  Status: Open,  Structure Length: 5.30m (17.39ft),  Average Daily Traffic: 1,264 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,896 (year 2036),  Design Load: H 15,  Features Intersected: ANDROSCOGGIN RIVER CANAL,  Facility Carried by Structure: HARTFORD STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.048,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 24.3m (79.7ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2021,  Underwater Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other
Find on map >>   Show street view

Structure Number: 5094,  Location: 1.3 MI S'LY OF JCT US 2 (Lat: 44.523031,  Lng: -70.537281),  Route carried "on" structure: County highway ,  Year Built: 1980,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 898 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,437 (year 2036),  Design Load: H 20,  Features Intersected: LOGAN BROOK,  Facility Carried by Structure: SOUTH RUMFORD ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.915,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft)

Condition: Channel: Satisfactory,  Culverts: Poor,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 5188,  Location: 0.1 MI E OF JCT US2 (Lat: 44.536161,  Lng: -70.542781),  Route carried "on" structure: County highway ,  Year Built: 1951,  Status: Open,  Structure Length: 6.14m (20.14ft),  Average Daily Traffic: 1,641 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,462 (year 2036),  Design Load: H 20,  Features Intersected: ANDROSCOGGIN RIVER,  Facility Carried by Structure: SOUTH RUMFORD ROAD
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 0.145,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 60.4m (198.2ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.2m (26.9ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Very good,  Operating Rating: 21.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 16.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 12 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Critical Feature Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 531,  Location: 1.0 MI SO TOWNLINE (Lat: 44.567950,  Lng: -70.560211),  Route carried "on" structure: County highway 120,  Year Built: 2002,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 1,362 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,043 (year 2036),  Design Load: Greater than HL93,  Features Intersected: SCOTTY RICHARDSON BROOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 22.627,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.7m (22.0ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 62.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 5619,  Location: .2 MI E US 2 (Lat: 44.544339,  Lng: -70.544211),  Route carried "on" structure: State highway 108,  Year Built: 1954,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 8.23m (27.00ft),  Average Daily Traffic: 7,389 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 10,345 (year 2036),  Design Load: H 20,  Features Intersected: MILL CANAL (ANDRO RIVER)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 42.583,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2021,  Underwater Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 5679,  Location: 250 FT NE ANDOVER ROAD (Lat: 44.512481,  Lng: -70.620089),  Route carried "on" structure: State highway 2,  Year Built: 1955,  Status: Open,  Structure Length: 0.72m (2.36ft),  Average Daily Traffic: 3,942 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 5,519 (year 2036),  Design Load: H 20,  Features Intersected: COFFIN BROOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 46.156,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 38.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 29.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 5754,  Location: .2 MI SO US 2 (Lat: 44.547919,  Lng: -70.536769),  Route carried "on" structure: State highway ,  Year Built: 1960,  Status: Open,  Structure Length: 5.43m (17.81ft),  Average Daily Traffic: 6,398 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 8,957 (year 2036),  Design Load: HS 20,  Features Intersected: MCRR SIDING,  Facility Carried by Structure: RAILROAD STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.032,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.6m (61.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Poor,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 54.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 5931,  Location: 0.1 MI N PORTLAND ST (Lat: 44.549711,  Lng: -70.543739),  Route carried "on" structure: City street ,  Year Built: 1913,  Year Reconstructed: 1964,  Status: Open,  Structure Length: 10.75m (35.27ft),  Average Daily Traffic: 310 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 496 (year 2036),  Design Load: H 20,  Features Intersected: MILL YARD,  Facility Carried by Structure: CONGRESS STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.740,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 15.2m (49.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Poor,  Operating Rating: 57.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 44.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 6325,  Location: CONNECTS RTE 17 TO 120 (Lat: 44.592500,  Lng: -70.563050),  Route carried "on" structure: City street ,  Year Built: 1974,  Status: Open,  Structure Length: 2.99m (9.81ft),  Average Daily Traffic: 372 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 595 (year 2036),  Design Load: HS 20,  Features Intersected: SWIFT RIVER,  Facility Carried by Structure: BLACK BRIDGE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.161,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.3m (92.8ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 9.7m (31.8ft)

Condition: Deck: Poor,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 51.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 6478,  Location: 0.1 Ml W of Martin Road (Lat: 44.534550,  Lng: -70.648619),  Route carried "on" structure: County highway ,  Year Built: 2015,  Status: Open,  Structure Length: 0.74m (2.43ft),  Average Daily Traffic: 682 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,091 (year 2016),  Design Load: HL 93,  Features Intersected: Meadow Brook,  Facility Carried by Structure: Andover Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.589,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.1m (23.3ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 47.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 6487,  Location: 1.38 MI NW INT RTE 2 (Lat: 44.526800,  Lng: -70.637661),  Route carried "on" structure: Other road ,  Year Built: 2015,  Status: Open,  Structure Length: 0.66m (2.17ft),  Average Daily Traffic: 795 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,272 (year 2036),  Design Load: Greater than HL93,  Features Intersected: Split Brook,  Facility Carried by Structure: Andover Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.221,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 8.5m (27.9ft)

Condition: Channel: Very good,  Culverts: Very good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: August 2021
Find on map >>   Show street view

Location: 1.4 MI N OF SIDNEY TL (Lat: 44.524831,  Lng: -70.643358),  Route carried "on" structure: Business County highway 12400,  Structure Length: 0. m,  Average Daily Traffic: 1,770 (year 2014),  Truck Traffic: 8%,  Features Intersected: I-95 SOUTHBOUND,  Facility Carried by Structure: WEBB ROAD
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 2.446,  Lanes on structure: 2,  Length of Maximum Span: 0.0m

Find on map >>   Show street view

Location: 3 MI N JCT 1A (Lat: 44.517403,  Lng: -70.561494),  Route carried "under" structure: Other road 12310,  Structure Length: 0. m,  Average Daily Traffic: 5,899 (year 2014),  Truck Traffic: 9%,  Features Intersected: BANGOR & AROOSTOOK,  Facility Carried by Structure: US 1 & ROUTE 3
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 270.418,  Lanes on structure: 2,  Length of Maximum Span: 0.0m

Discuss Rumford, Maine (ME) on our hugely popular Maine forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.