  • National Bridge Inventory (NBI) Statistics
  • 25Number of bridges
  • 715ft / 218mTotal length
  • $11,733,000Total costs
  • 53,313Total average daily traffic
  • 7,440Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Glendive
  • No street view available for this location

New bridges in Glendive, MT - historical statistics
  • New bridges - historical statistics
  • 21950-1959
  • 151960-1969
  • 21970-1979
  • 51980-1989
  • 12010-2019
Average Bridge Daily Traffic in Glendive, MT
Average Bridge Truck Traffic in Glendive, MT
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 6.7%Very good
  • 20.0%Good
  • 73.3%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 20.0%Very good
  • 33.3%Good
  • 33.3%Satisfactory
  • 13.3%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 6.7%Very good
  • 33.3%Good
  • 53.3%Satisfactory
  • 6.7%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 26.3%Good
  • 57.9%Satisfactory
  • 15.8%Fair
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 71.4%Satisfactory
  • 28.6%Fair
Find on map >>   Show street view

Structure Number: 202008006,  Location: 5M SE CLYDE PARK (Lat: 45.825539,  Lng: -110.547569),  Route carried "on" structure: County highway 347,  Year Built: 2019,  Status: Open,  Structure Length: 0.76m (2.49ft),  Average Daily Traffic: 100 (year 2022),  Truck Traffic: 3%,  Average Future Daily Traffic: 100 (year 2037),  Design Load: HL 93,  Features Intersected: IRRIGATION CANAL,  Facility Carried by Structure: SHIELDS RIVER ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.368,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 1 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.3m (24.0ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 34.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 202008007,  Location: NW Glendive (Lat: 47.116450,  Lng: -104.764531),  Route carried "on" structure: County highway 11603,  Year Built: 1970,  Status: Open,  Structure Length: 1.14m (3.74ft),  Average Daily Traffic: 242 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 254 (year 2040),  Features Intersected: Dry Creek,  Facility Carried by Structure: Dry Creek Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.294,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 5.6m (18.4ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 37.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: I00094214+08321,  Location: N GLENDIVE (Lat: 47.122861,  Lng: -104.707758),  Route carried "on" structure: Interstate 94,  Year Built: 1968,  Status: Open,  Structure Length: 60.16m (197.38ft),  Average Daily Traffic: 6,764 (year 2020),  Truck Traffic: 18%,  Average Future Daily Traffic: 7,812 (year 2040),  Design Load: HS 20,  Features Intersected: YELLOWSTONE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 344.872,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 8,  Number Of Approach Spans: 2,  Length of Maximum Span: 82.3m (270.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 35.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 60.09m (197.15ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2021,  Critical Feature Inspection Date: May 2021,  Underwater Inspection Date: October 2020,  Bridge Improvement Cost: $3,872,000,  Roadway Improvement Cost: $1,936,000,  Total Project Cost: $5,808,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: I00094214+08322,  Location: N GLENDIVE (Lat: 47.123047,  Lng: -104.707578),  Route carried "on" structure: Interstate 94,  Year Built: 1968,  Status: Open,  Structure Length: 61.38m (201.38ft),  Average Daily Traffic: 6,764 (year 2020),  Truck Traffic: 18%,  Average Future Daily Traffic: 7,812 (year 2040),  Design Load: HS 20,  Features Intersected: YELLOWSTONE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 345.746,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 8,  Number Of Approach Spans: 2,  Length of Maximum Span: 82.3m (270.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 35.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 20.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 61.38m (201.38ft),  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2021,  Critical Feature Inspection Date: May 2021,  Underwater Inspection Date: October 2020,  Bridge Improvement Cost: $3,950,000,  Roadway Improvement Cost: $1,975,000,  Total Project Cost: $5,925,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: I00094216+08651,  Location: 1M E GLENDIVE (Lat: 47.120542,  Lng: -104.665394),  Route carried "on" structure: Interstate 94,  Year Built: 1969,  Status: Open,  Structure Length: 6.95m (22.80ft),  Average Daily Traffic: 3,658 (year 2020),  Truck Traffic: 23%,  Average Future Daily Traffic: 3,841 (year 2040),  Design Load: HS 20,  Features Intersected: GLENDIVE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 348.157,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.5m (77.1ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: I00094216+08652,  Location: 1M E GLENDIVE (Lat: 47.120728,  Lng: -104.665250),  Route carried "on" structure: Interstate 94,  Year Built: 1969,  Status: Open,  Structure Length: 6.95m (22.80ft),  Average Daily Traffic: 3,658 (year 2020),  Truck Traffic: 23%,  Average Future Daily Traffic: 3,841 (year 2040),  Design Load: HS 20,  Features Intersected: GLENDIVE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 349.028,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 23.5m (77.1ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.3m (40.4ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: I00094218+05881,  Location: 3M E GLENDIVE (Lat: 47.108783,  Lng: -104.634586),  Route carried "on" structure: Interstate 94,  Year Built: 1980,  Status: Open,  Structure Length: 3.44m (11.29ft),  Average Daily Traffic: 3,658 (year 2020),  Truck Traffic: 23%,  Average Future Daily Traffic: 3,841 (year 2040),  Design Load: HS 20,  Features Intersected: SEP COUNTY RD 300
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 350.941,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 12.6m (41.3ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: I00094218+05882,  Location: 3M E GLENDIVE (Lat: 47.108883,  Lng: -104.634342),  Route carried "on" structure: Interstate 94,  Year Built: 1980,  Status: Open,  Structure Length: 3.44m (11.29ft),  Average Daily Traffic: 3,658 (year 2020),  Truck Traffic: 23%,  Average Future Daily Traffic: 3,841 (year 2040),  Design Load: HS 20,  Features Intersected: SEP COUNTY RD 300
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 351.824,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.8m (38.7ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 12.6m (41.3ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: L11315001+03001,  Location: 1M E GLENDIVE (Lat: 47.120981,  Lng: -104.664925),  Route carried "on" structure: ServiceState highway 11315,  Year Built: 1969,  Status: Open,  Structure Length: 6.49m (21.29ft),  Average Daily Traffic: 695 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 730 (year 2040),  Design Load: HS 20,  Features Intersected: GLENDIVE CREEK 084,  Facility Carried by Structure: FRONTAGE ROAD 315
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.231,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.9m (71.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 9.5m (31.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 61.6 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: M11050000+00201,  Location: WEST GLENDIVE-PINE ST (Lat: 47.107175,  Lng: -104.752014),  Route carried "on" structure: City street 5012,  Year Built: 1981,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 589 (year 2020),  Average Future Daily Traffic: 618 (year 2040),  Design Load: HS 20,  Features Intersected: DRY CREEK 076,  Facility Carried by Structure: PINE STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.576,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.8m (25.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Channel Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.4m (44.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: M11050000+00301,  Location: GLENDIVE-N KENDRICK AVE (Lat: 47.113425,  Lng: -104.706617),  Route carried "on" structure: City street 11050,  Year Built: 1965,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 1,779 (year 2020),  Truck Traffic: 3%,  Average Future Daily Traffic: 1,868 (year 2040),  Design Load: HS 20,  Features Intersected: GRAVEYARD COULEE 093,  Facility Carried by Structure: N KENDRICK AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.324,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.4m (14.4ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 1.7m (5.6ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 50.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: M11050000+00401,  Location: GLENDIVE-MEADE AVE (Lat: 47.113692,  Lng: -104.708225),  Route carried "on" structure: City street 5002,  Year Built: 1965,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 754 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 792 (year 2040),  Design Load: HS 20,  Features Intersected: GRAVEYARD COULEE 094,  Facility Carried by Structure: MEADE AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.186,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.3m (14.1ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.7m (5.6ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 50.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: M11050000+00501,  Location: GLENDIVE-S PEARSON AVE (Lat: 47.096061,  Lng: -104.717522),  Route carried "on" structure: City street 11050,  Year Built: 1965,  Status: Open,  Structure Length: 0.90m (2.95ft),  Average Daily Traffic: 100 (year 2022),  Truck Traffic: 3%,  Average Future Daily Traffic: 100 (year 2037),  Design Load: HS 20,  Features Intersected: CAINS COULEE 095,  Facility Carried by Structure: S PEARSON AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.812,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.6m (41.3ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.0m (29.5ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: M11050000+00601,  Location: GLENDIVE-S SARGENT AVE (Lat: 47.095464,  Lng: -104.716183),  Route carried "on" structure: City street 5008,  Year Built: 1965,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 1,024 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,075 (year 2040),  Design Load: HS 20,  Features Intersected: CAINS COULEE 096,  Facility Carried by Structure: S SARGENT AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.231,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 1.9m (6.2ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: M11050000+00701,  Location: GLENDIVE-S TAYLOR AVE (Lat: 47.094278,  Lng: -104.713556),  Route carried "on" structure: City street 5010,  Year Built: 1965,  Status: Open,  Structure Length: 0.90m (2.95ft),  Average Daily Traffic: 1,486 (year 2020),  Average Future Daily Traffic: 1,560 (year 2040),  Design Load: HS 20,  Features Intersected: CAINS COULEE 097,  Facility Carried by Structure: TAYLOR AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.631,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.0m (29.5ft),  Curb or Sidewalk Widths: Left: 2.3m (7.5ft),  Right: 1.7m (5.6ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 44.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: P00020007+00501,  Location: 7M NE GLENDIVE (Lat: 47.198944,  Lng: -104.682444),  Route carried "on" structure: State highway 16,  Year Built: 1964,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 3,598 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 4,084 (year 2040),  Features Intersected: THREE MILE CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.319,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.5m (11.5ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021
Find on map >>   Show street view

Structure Number: P00057000+03941,  Location: 3M SE BELT (Lat: 47.345156,  Lng: -110.890692),  Route carried "on" structure: US 87,  Year Built: 1959,  Status: Open,  Structure Length: 3.78m (12.40ft),  Average Daily Traffic: 1,046 (year 2020),  Truck Traffic: 34%,  Average Future Daily Traffic: 1,098 (year 2040),  Design Load: HS 20,  Features Intersected: OTTER CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.636,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 12.6m (41.3ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 66.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: P00057327+03371,  Location: GLENDIVE-TOWNE ST (Lat: 47.107286,  Lng: -104.720864),  Route carried "on" structure: State highway 200,  Year Built: 1958,  Status: Open,  Structure Length: 40.31m (132.25ft),  Average Daily Traffic: 8,515 (year 2020),  Average Future Daily Traffic: 8,941 (year 2040),  Design Load: HS 20,  Features Intersected: YELLOWSTONE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 524.162,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.9m (55.4ft),  Material/Design: Steel continuous,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 55.8m (183.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.2m (3.9ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2021,  Critical Feature Inspection Date: May 2021,  Underwater Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: P00057329+03381,  Location: NE GLENDIVE-MERRILL AVE (Lat: 47.123842,  Lng: -104.694681),  Route carried "on" structure: State highway 200,  Year Built: 1969,  Status: Open,  Structure Length: 10.79m (35.40ft),  Average Daily Traffic: 100 (year 2022),  Truck Traffic: 3%,  Average Future Daily Traffic: 100 (year 2037),  Design Load: HS 20,  Features Intersected: INT E GLENDIVE I 94
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 527.316,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 31.4m (103.0ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 62.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 33.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: S00335000+06001,  Location: S GLENDIVE (Lat: 47.097278,  Lng: -104.720000),  Route carried "on" structure: Alternate State highway 335,  Year Built: 1964,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 1.05m (3.44ft),  Average Daily Traffic: 456 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 479 (year 2040),  Design Load: HL 93,  Features Intersected: CAINS COULEE,  Facility Carried by Structure: MARSH RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.057,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.9m (29.2ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.7m (15.4ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 89.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 89.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020
Find on map >>   Show street view

Structure Number: S00335001+07141,  Location: 1M S GLENDIVE (Lat: 47.083889,  Lng: -104.732472),  Route carried "on" structure: State highway 335,  Year Built: 1964,  Status: Open,  Structure Length: 1.57m (5.15ft),  Average Daily Traffic: 456 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 479 (year 2040),  Design Load: HS 15,  Features Intersected: DRAINAGE,  Facility Carried by Structure: MARSH RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.823,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.9m (29.2ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 7.6m (24.9ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 36.3 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: S00335003+07691,  Location: 3M S GLENDIVE (Lat: 47.057250,  Lng: -104.740583),  Route carried "on" structure: State highway 335,  Year Built: 1970,  Status: Open,  Structure Length: 2.82m (9.25ft),  Average Daily Traffic: 359 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 377 (year 2040),  Design Load: HS 20,  Features Intersected: DRAINAGE,  Facility Carried by Structure: MARSH RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.131,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.2m (30.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 13.7m (44.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 9.6m (31.5ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 47.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: I00094218+05881,  Location: 3M E GLENDIVE (Lat: 47.108783,  Lng: -104.634586),  Route carried "under" structure: ServiceCounty highway 11315,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 98 (year 2020),  Truck Traffic: 20%,  Features Intersected: SEP COUNTY RD 300,  Facility Carried by Structure: I 94
Minimum Vertical Clearance: 5.14m (16.86ft),  Kilometerpoint: 5.093,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 12.2m (40.0ft)

Find on map >>   Show street view

Structure Number: I00094218+05882,  Location: 3M E GLENDIVE (Lat: 47.108883,  Lng: -104.634342),  Route carried "under" structure: ServiceCounty highway 11315,  Year Built: 1980,  Structure Length: 0. m,  Average Daily Traffic: 98 (year 2020),  Truck Traffic: 20%,  Features Intersected: SEP COUNTY RD 300,  Facility Carried by Structure: I 94
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 5.072,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 12.2m (40.0ft)

Find on map >>   Show street view

Structure Number: P00057329+03381,  Location: NE GLENDIVE-MERRILL AVE (Lat: 47.123842,  Lng: -104.694681),  Route carried "under" structure: Interstate 94,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 3,658 (year 2020),  Truck Traffic: 23%,  Features Intersected: INT E GLENDIVE I 94,  Facility Carried by Structure: S 200S-MERRILL AVE
Minimum Vertical Clearance: 5.22m (17.13ft),  Kilometerpoint: 345.869,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 31.4m (103.0ft)