Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Doctor Phillips, Florida (FL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 17Number of bridges
  • 269ft / 81.9mTotal length
  • $66,000Total costs
  • 852,400Total average daily traffic
  • 63,666Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Doctor Phillips
  • No street view available for this location

New bridges in Doctor Phillips, FL - historical statistics
  • New bridges - historical statistics
  • 41960-1969
  • 51970-1979
  • 81990-1999
Reconstructed bridges in Doctor Phillips, FL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11970-1979
  • 01980-1989
  • 11990-1999
Average Bridge Daily Traffic in Doctor Phillips, FL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 85.7%Good
  • 14.3%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 85.7%Good
  • 14.3%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 71.4%Good
  • 28.6%Satisfactory
Find on map >>   Show street view

Structure Number: 750087,  Location: I-4 & SR 528 Interchange (Lat: 28.421781,  Lng: -81.474586),  Route carried "on" structure: Ramp State highway 528,  Year Built: 1973,  Status: Open,  Structure Length: 18.93m (62.11ft),  Average Daily Traffic: 18,500 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 32,098 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: INTERSTATE 4 SR 400
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 7,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 30.9m (101.4ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 40.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 750142,  Location: I-4 WB - Central Fl Pkwy (Lat: 28.410314,  Lng: -81.475558),  Route carried "on" structure: Interstate 4,  Year Built: 1960,  Year Reconstructed: 1979,  Status: Open,  Structure Length: 2.71m (8.89ft),  Average Daily Traffic: 97,000 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 168,295 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: Central Fl Pkwy
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.861,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.9m (65.3ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 26.5m (86.9ft),  Curb-To-Curb Width: 21.0m (68.9ft),  Out-to-Out Width: 21.6m (70.9ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 31.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.79m (5.87ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Bridge Improvement Cost: $20,000,  Total Project Cost: $66,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 75018,  Location: I-4 & SR 528 INTERSECTION (Lat: 28.420178,  Lng: -81.474250),  Route carried "on" structure: Ramp State highway 528,  Year Built: 1973,  Status: Open,  Structure Length: 9.36m (30.71ft),  Average Daily Traffic: 17,500 (year 2020),  Truck Traffic: 12%,  Average Future Daily Traffic: 30,362 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: INTERSTATE 4 SR 400
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.378,  Lanes on structure: 1,  Lanes under structure: 6,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 7.7m (25.3ft),  Skew: 9 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 32.6m (107.0ft),  Curb-To-Curb Width: 8.3m (27.2ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 39.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 7502,  Location: I-4 EB - Central Fl Pkwy (Lat: 28.410197,  Lng: -81.475306),  Route carried "on" structure: Interstate 4,  Year Built: 1960,  Year Reconstructed: 2002,  Status: Open,  Structure Length: 2.69m (8.83ft),  Average Daily Traffic: 97,000 (year 2020),  Truck Traffic: 8%,  Average Future Daily Traffic: 168,295 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: Central Fl Parkway
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.861,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 26.2m (86.0ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 31.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 28.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 750335,  Location: I-4 WB - SR-482 (Lat: 28.449981,  Lng: -81.474528),  Route carried "on" structure: Interstate 4,  Year Built: 1991,  Status: Open,  Structure Length: 5.09m (16.70ft),  Average Daily Traffic: 50,000 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 86,750 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SR-482
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.279,  Lanes on structure: 5,  Lanes under structure: 10,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 24.9m (81.7ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 50.3m (165.0ft),  Curb-To-Curb Width: 24.9m (81.7ft),  Out-to-Out Width: 25.9m (85.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 60.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 36.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 750336,  Location: I-4 EB - SR-482 (Lat: 28.449992,  Lng: -81.474119),  Route carried "on" structure: Interstate 4,  Year Built: 1991,  Status: Open,  Structure Length: 5.08m (16.67ft),  Average Daily Traffic: 50,000 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 86,750 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SR-482
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 13.279,  Lanes on structure: 3,  Lanes under structure: 10,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 16.6m (54.5ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 50.2m (164.7ft),  Curb-To-Curb Width: 17.0m (55.8ft),  Out-to-Out Width: 17.9m (58.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 64.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 750402,  Location: Central Fl Pkwy Ramp- I-4 (Lat: 28.409664,  Lng: -81.475419),  Route carried "on" structure: Ramp Other road 4,  Year Built: 1990,  Status: Open,  Structure Length: 38.07m (124.90ft),  Average Daily Traffic: 9,400 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 16,309 (year 2042),  Design Load: HS 20,  Features Intersected: I-4,  Facility Carried by Structure: Central Fl Parkway
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.116,  Lanes on structure: 1,  Lanes under structure: 11,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Steel continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 56.8m (186.4ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 75.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: November 2020,  Critical Feature Inspection Date: November 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 750087,  Location: I-4 & SR 528 Interchange (Lat: 28.421781,  Lng: -81.474586),  Route carried "under" structure: Ramp State highway 528,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 17,500 (year 2020),  Truck Traffic: 12%,  Features Intersected: INTERSTATE 4 SR 400
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 0.246,  Lanes on structure: 2,  Lanes under structure: 1,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.9m (101.4ft)

Find on map >>   Show street view

Structure Number: 750087,  Location: I-4 & SR 528 Interchange (Lat: 28.421781,  Lng: -81.474586),  Route carried "under" structure: Interstate 4,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 194,000 (year 2020),  Truck Traffic: 8%,  Features Intersected: INTERSTATE 4 SR 400,  Facility Carried by Structure: SR528 EXIT RMP 0.0
Minimum Vertical Clearance: 5.72m (18.77ft),  Kilometerpoint: 10.203,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 30.9m (101.4ft)

Find on map >>   Show street view

Structure Number: 750142,  Location: I-4 WB - Central Fl Pkwy (Lat: 28.410314,  Lng: -81.475558),  Route carried "under" structure: County highway ,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 17,900 (year 2020),  Truck Traffic: 7%,  Features Intersected: Central Fl Pkwy,  Facility Carried by Structure: I-4 WB
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 0.179,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.5m (86.9ft)

Find on map >>   Show street view

Structure Number: 75018,  Location: I-4 & SR 528 INTERSECTION (Lat: 28.420178,  Lng: -81.474250),  Route carried "under" structure: Interstate 4,  Year Built: 1973,  Structure Length: 0. m,  Average Daily Traffic: 194,000 (year 2020),  Truck Traffic: 8%,  Features Intersected: INTERSTATE 4 SR 400,  Facility Carried by Structure: SR 528 RAMP 0.0
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 9.992,  Lanes on structure: 1,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 32.6m (107.0ft)

Find on map >>   Show street view

Structure Number: 7502,  Location: I-4 EB - Central Fl Pkwy (Lat: 28.410197,  Lng: -81.475306),  Route carried "under" structure: County highway ,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 17,900 (year 2020),  Truck Traffic: 7%,  Features Intersected: Central Fl Parkway,  Facility Carried by Structure: I-4 EB
Minimum Vertical Clearance: 5.24m (17.19ft),  Kilometerpoint: 0.225,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.2m (86.0ft)

Find on map >>   Show street view

Structure Number: 750335,  Location: I-4 WB - SR-482 (Lat: 28.449981,  Lng: -81.474528),  Route carried "under" structure: State highway 482,  Year Built: 1991,  Structure Length: 0. m,  Average Daily Traffic: 28,500 (year 2020),  Truck Traffic: 5%,  Features Intersected: SR-482,  Facility Carried by Structure: I-4 WB
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 0.195,  Lanes on structure: 5,  Lanes under structure: 10,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 50.3m (165.0ft)

Find on map >>   Show street view

Structure Number: 750336,  Location: I-4 EB - SR-482 (Lat: 28.449992,  Lng: -81.474119),  Route carried "under" structure: State highway 482,  Year Built: 1991,  Structure Length: 0. m,  Average Daily Traffic: 28,500 (year 2020),  Truck Traffic: 5%,  Features Intersected: SR-482,  Facility Carried by Structure: I-4 EB
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 0.233,  Lanes on structure: 3,  Lanes under structure: 10,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 50.2m (164.7ft)

Find on map >>   Show street view

Structure Number: 750402,  Location: Central Fl Pkwy Ramp- I-4 (Lat: 28.409664,  Lng: -81.475419),  Route carried "under" structure: Ramp Other road ,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 1,200 (year 2020),  Truck Traffic: 1%,  Features Intersected: I-4,  Facility Carried by Structure: Central Fl Parkway
Minimum Vertical Clearance: 11.25m (36.91ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 1,  Material/Design: Steel continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 56.8m (186.4ft)

Find on map >>   Show street view

Structure Number: 750402,  Location: Central Fl Pkwy Ramp- I-4 (Lat: 28.409664,  Lng: -81.475419),  Route carried "under" structure: City street ,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 3,000 (year 2020),  Truck Traffic: 1%,  Features Intersected: I-4,  Facility Carried by Structure: Central Fl Parkway
Minimum Vertical Clearance: 6.68m (21.92ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 2,  Material/Design: Steel continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 56.8m (186.4ft)

Find on map >>   Show street view

Structure Number: 750402,  Location: Central Fl Pkwy Ramp- I-4 (Lat: 28.409664,  Lng: -81.475419),  Route carried "under" structure: Interstate 4,  Year Built: 1990,  Structure Length: 0. m,  Average Daily Traffic: 10,500 (year 2020),  Truck Traffic: 6%,  Features Intersected: I-4,  Facility Carried by Structure: Central Fl Parkway
Minimum Vertical Clearance: 5.97m (19.59ft),  Kilometerpoint: 0.027,  Lanes on structure: 1,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 56.8m (186.4ft)

Discuss Doctor Phillips, Florida (FL) on our hugely popular Florida forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.