Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Clermont, Florida (FL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 23Number of bridges
  • 223ft / 67.8mTotal length
  • 365,751Total average daily traffic
  • 61,199Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Clermont
  • No street view available for this location

New bridges in Clermont, FL - historical statistics
  • New bridges - historical statistics
  • 11940-1949
  • 11950-1959
  • 101960-1969
  • 21990-1999
  • 62000-2009
  • 32010-2019
Average Bridge Daily Traffic in Clermont, FL
Average Bridge Truck Traffic in Clermont, FL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 38.5%Very good
  • 38.5%Good
  • 23.1%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 30.8%Very good
  • 53.8%Good
  • 15.4%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 30.8%Very good
  • 53.8%Good
  • 15.4%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 28.6%Very good
  • 71.4%Good
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Good
  • 50.0%Satisfactory
Find on map >>   Show street view

Structure Number: 110032,  Location: 1.2MI N OF ORANGE CO LINE (Lat: 28.558756,  Lng: -81.677094),  Route carried "on" structure: State highway 91,  Year Built: 1964,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 8.98m (29.46ft),  Average Daily Traffic: 30,550 (year 2020),  Truck Traffic: 21%,  Average Future Daily Traffic: 53,004 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SR 438
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.997,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 23.5m (77.1ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 34.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 26.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 110033,  Location: 3.1MI N OF ORANGE CO LINE (Lat: 28.575967,  Lng: -81.700233),  Route carried "on" structure: State highway 91,  Year Built: 1964,  Status: Open,  Structure Length: 4.01m (13.16ft),  Average Daily Traffic: 30,550 (year 2020),  Truck Traffic: 21%,  Average Future Daily Traffic: 53,004 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: BLACKSTILL LAKE RD
Minimum Vertical Clearance: 30.45m (99.90ft),  Kilometerpoint: 5.003,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.7m (44.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 110037,  Location: 1.2MI N OF ORANGE CO LINE (Lat: 28.559025,  Lng: -81.677275),  Route carried "on" structure: State highway 91,  Year Built: 1964,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 8.98m (29.46ft),  Average Daily Traffic: 30,550 (year 2020),  Truck Traffic: 21%,  Average Future Daily Traffic: 53,004 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SR 438
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.029,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 5 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 23.5m (77.1ft),  Curb-To-Curb Width: 12.3m (40.4ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 34.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 26.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 110038,  Location: 3.1MI N OF ORANGE CO LINE (Lat: 28.575978,  Lng: -81.699994),  Route carried "on" structure: State highway 91,  Year Built: 1964,  Status: Open,  Structure Length: 4.02m (13.19ft),  Average Daily Traffic: 30,550 (year 2020),  Truck Traffic: 21%,  Average Future Daily Traffic: 53,004 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: BLACKSTILL LAKE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.997,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Toll: On toll road,  Owner: State Toll Authority,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 13.7m (44.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 32.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 110052,  Location: 1.6MI N OF ORANGE CO LINE (Lat: 28.560900,  Lng: -81.682250),  Route carried "on" structure: County highway 455,  Year Built: 1964,  Status: Open,  Structure Length: 6.60m (21.65ft),  Average Daily Traffic: 6,800 (year 2020),  Truck Traffic: 7%,  Average Future Daily Traffic: 11,798 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: SR 91 TPK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.588,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Toll Authority,  Approaching Roadway Width: 7.7m (25.3ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.0m (65.6ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 34.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 26.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 110087,  Location: US-27 SB - Pitt Street (Lat: 28.557606,  Lng: -81.743486),  Route carried "on" structure: US 27,  Year Built: 2008,  Status: Open,  Structure Length: 2.90m (9.51ft),  Average Daily Traffic: 13,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 22,555 (year 2042),  Design Load: HL 93,  Features Intersected: Pitt Street
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.946,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.3m (92.8ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 66.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 61.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 110088,  Location: US-27 NB - Pitt Street (Lat: 28.557606,  Lng: -81.743281),  Route carried "on" structure: US 27,  Year Built: 2008,  Status: Open,  Structure Length: 2.90m (9.51ft),  Average Daily Traffic: 13,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 22,555 (year 2042),  Design Load: HL 93,  Features Intersected: Pitt Street
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 24.948,  Lanes on structure: 3,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 28.3m (92.8ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Very good,  Operating Rating: 66.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 61.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 110093,  Location: US -27 over SR-50 (Lat: 28.547333,  Lng: -81.742056),  Route carried "on" structure: State highway 27,  Year Built: 2013,  Status: Open,  Structure Length: 5.19m (17.03ft),  Average Daily Traffic: 26,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 45,110 (year 2042),  Design Load: HL 93,  Features Intersected: SR-50
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 23.768,  Lanes on structure: 10,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 52.4m (171.9ft),  Skew: 31 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 26.1m (85.6ft),  Curb-To-Curb Width: 52.4m (171.9ft),  Out-to-Out Width: 56.4m (185.0ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 39.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 35.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 114045,  Location: 2.4 MI W of US-27 (Lat: 28.581264,  Lng: -81.787089),  Route carried "on" structure: County highway 561,  Year Built: 1958,  Status: Open,  Structure Length: 4.88m (16.01ft),  Average Daily Traffic: 3,900 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 6,767 (year 2042),  Design Load: H 15,  Features Intersected: Crystal Cove
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.388,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.0m (23.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 8,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 57.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Underwater Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 114078,  Location: 0.8 MILE EAST OF CR-561 (Lat: 28.515753,  Lng: -81.771364),  Route carried "on" structure: County highway ,  Year Built: 1940,  Status: Posted for load,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 1,501 (year 2021),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,001 (year 2042),  Design Load: HS 20,  Features Intersected: Crescent Lake Canal,  Facility Carried by Structure: Bronson Rd.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.331,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: High priority of replacement,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Underwater Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 114091,  Location: 0.9 MI NORTH OF SR-50 (Lat: 28.565653,  Lng: -81.777047),  Route carried "on" structure: Alternate County highway 561A,  Year Built: 1999,  Status: Open,  Structure Length: 4.33m (14.21ft),  Average Daily Traffic: 3,900 (year 2021),  Truck Traffic: 10%,  Average Future Daily Traffic: 6,767 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: LAKE MINNEOLA
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.048,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.2m (46.6ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.0m (9.8ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 16.2m (53.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 53.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Underwater Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 114092,  Location: 1.0 MI SW OF SR-50 (Lat: 28.544047,  Lng: -81.783708),  Route carried "on" structure: County highway 561,  Year Built: 1999,  Status: Open,  Structure Length: 7.38m (24.21ft),  Average Daily Traffic: 1,100 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,909 (year 2042),  Design Load: HS 20,  Features Intersected: Lake Minnehaha Canal
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 17.281,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 83.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Underwater Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 114096,  Location: 2.3 Miles East of CR-561 (Lat: 28.461244,  Lng: -81.757317),  Route carried "on" structure: County highway ,  Year Built: 2004,  Status: Open,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 100 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 125 (year 2042),  Design Load: HS 20,  Features Intersected: Little Creek,  Facility Carried by Structure: Lake Nellie Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.5m (24.6ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.1m (10.2ft)

Condition: Channel: Good,  Culverts: Good,  Inventory Rating: 62.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Underwater Inspection Date: March 2021
Find on map >>   Show street view

Structure Number: 114098,  Location: 2.25 Mi West of US 27 (Lat: 28.520381,  Lng: -81.756014),  Route carried "on" structure: County highway 1040A,  Year Built: 2012,  Status: Open,  Structure Length: 3.66m (12.01ft),  Average Daily Traffic: 3,000 (year 2020),  Truck Traffic: 10%,  Average Future Daily Traffic: 5,205 (year 2042),  Design Load: HL 93,  Features Intersected: Palatlakaha River,  Facility Carried by Structure: Lakeshore Drive
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.769,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 36.6m (120.1ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 0.0m,  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 15.8m (51.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 46.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Underwater Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 118002,  Location: 2 Miles W of US-27 (Lat: 28.447297,  Lng: -81.740331),  Route carried "on" structure: State lands road ,  Year Built: 2001,  Status: Open,  Structure Length: 2.34m (7.68ft),  Average Daily Traffic: 50 (year 2011),  Truck Traffic: 5%,  Average Future Daily Traffic: 105 (year 2033),  Design Load: HS 25 or greater,  Features Intersected: Big Creek,  Facility Carried by Structure: Lake Louisa Rd.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Agenciy,  Approaching Roadway Width: 9.5m (31.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 8.8m (28.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Inventory Rating: 75.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 110032,  Location: 1.2MI N OF ORANGE CO LINE (Lat: 28.558756,  Lng: -81.677094),  Route carried "under" structure: State highway 438,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 30,550 (year 2020),  Truck Traffic: 21%,  Features Intersected: SR 438,  Facility Carried by Structure: SR 91 TPK SB 275.3
Minimum Vertical Clearance: 6.98m (22.90ft),  Kilometerpoint: 1.960,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.5m (77.1ft)

Find on map >>   Show street view

Structure Number: 110033,  Location: 3.1MI N OF ORANGE CO LINE (Lat: 28.575967,  Lng: -81.700233),  Route carried "under" structure: County highway ,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 1,850 (year 2020),  Truck Traffic: 19%,  Features Intersected: BLACKSTILL LAKE RD,  Facility Carried by Structure: SR 91 TPK SB 277.1
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 1.323,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 13.7m (44.9ft)

Find on map >>   Show street view

Structure Number: 110037,  Location: 1.2MI N OF ORANGE CO LINE (Lat: 28.559025,  Lng: -81.677275),  Route carried "under" structure: State highway 438,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 30,550 (year 2020),  Truck Traffic: 21%,  Features Intersected: SR 438,  Facility Carried by Structure: SR 91 TPK NB 275.3
Minimum Vertical Clearance: 7.01m (23.00ft),  Kilometerpoint: 2.029,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 23.5m (77.1ft)

Find on map >>   Show street view

Structure Number: 110038,  Location: 3.1MI N OF ORANGE CO LINE (Lat: 28.575978,  Lng: -81.699994),  Route carried "under" structure: County highway ,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 1,850 (year 2020),  Truck Traffic: 19%,  Features Intersected: BLACKSTILL LAKE RD,  Facility Carried by Structure: SR 91 TPK NB 277.1
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 1.344,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 13.7m (44.9ft)

Find on map >>   Show street view

Structure Number: 110052,  Location: 1.6MI N OF ORANGE CO LINE (Lat: 28.560900,  Lng: -81.682250),  Route carried "under" structure: State highway 91,  Year Built: 1964,  Structure Length: 0. m,  Average Daily Traffic: 61,100 (year 2020),  Truck Traffic: 21%,  Features Intersected: SR 91 TPK,  Facility Carried by Structure: CR 455 275.6
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 2.594,  Lanes on structure: 2,  Lanes under structure: 4,  Toll: On toll road,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.0m (65.6ft)

Find on map >>   Show street view

Structure Number: 110087,  Location: US-27 SB - Pitt Street (Lat: 28.557606,  Lng: -81.743486),  Route carried "under" structure: Business City street ,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 400 (year 2003),  Truck Traffic: 5%,  Features Intersected: Pitt Street,  Facility Carried by Structure: US-27 SB
Minimum Vertical Clearance: 6.07m (19.91ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.3m (92.8ft)

Find on map >>   Show street view

Structure Number: 110088,  Location: US-27 NB - Pitt Street (Lat: 28.557606,  Lng: -81.743281),  Route carried "under" structure: Business City street ,  Year Built: 2008,  Structure Length: 0. m,  Average Daily Traffic: 400 (year 2003),  Truck Traffic: 5%,  Features Intersected: Pitt Street,  Facility Carried by Structure: US-27 NB
Minimum Vertical Clearance: 5.27m (17.29ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.3m (92.8ft)

Find on map >>   Show street view

Structure Number: 110093,  Location: US -27 over SR-50 (Lat: 28.547333,  Lng: -81.742056),  Route carried "under" structure: State highway 50,  Year Built: 2013,  Structure Length: 0. m,  Average Daily Traffic: 44,500 (year 2016),  Truck Traffic: 5%,  Features Intersected: SR-50,  Facility Carried by Structure: US-27
Minimum Vertical Clearance: 5.09m (16.70ft),  Kilometerpoint: 17.555,  Lanes on structure: 10,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.1m (85.6ft)

Discuss Clermont, Florida (FL) on our hugely popular Florida forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.