Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Bridgeville, Pennsylvania (PA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 28Number of bridges
  • 315ft / 95.8mTotal length
  • $3,819,000Total costs
  • 528,024Total average daily traffic
  • 75,212Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Bridgeville
  • No street view available for this location

New bridges in Bridgeville, PA - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 11920-1929
  • 31930-1939
  • 21950-1959
  • 131960-1969
  • 11980-1989
  • 31990-1999
  • 32000-2009
  • 12010-2019
Reconstructed bridges in Bridgeville, PA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 01960-1969
  • 01970-1979
  • 01980-1989
  • 31990-1999
  • 32000-2009
Average Bridge Daily Traffic in Bridgeville, PA
Average Bridge Truck Traffic in Bridgeville, PA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 25.0%Very good
  • 43.8%Good
  • 18.8%Satisfactory
  • 6.3%Fair
  • 6.3%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 29.4%Very good
  • 35.3%Good
  • 11.8%Satisfactory
  • 17.6%Fair
  • 5.9%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 11.8%Very good
  • 35.3%Good
  • 35.3%Satisfactory
  • 11.8%Fair
  • 5.9%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 6.3%Excellent
  • 31.3%Very good
  • 25.0%Good
  • 12.5%Satisfactory
  • 6.3%Fair
  • 18.8%Poor
Find on map >>   Show street view

Structure Number: 695,  Location: NORTH END OF BRIDGEVILLE (Lat: 40.358333,  Lng: -80.100000),  Route carried "on" structure: State highway 50,  Year Built: 1986,  Status: Open,  Structure Length: 2.53m (8.30ft),  Average Daily Traffic: 34,004 (year 2022),  Truck Traffic: 7%,  Average Future Daily Traffic: 21,171 (year 2032),  Design Load: HS 20,  Features Intersected: CHARTIERS CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.791,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 24.7m (81.0ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Inventory Rating: 50.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.50m (8.20ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2020,  Bridge Improvement Cost: $10,000,  Roadway Improvement Cost: $39,000,  Total Project Cost: $132,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 855,  Location: NORTH OF TR50 (Lat: 40.358678,  Lng: -80.118633),  Route carried "on" structure: Interstate 79,  Year Built: 1965,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 17.50m (57.41ft),  Average Daily Traffic: 31,325 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 29,322 (year 2032),  Design Load: HS 20,  Features Intersected: WLE RR,CHARTIERS CREEK,  Facility Carried by Structure: RAYMOND SHAFER HW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.635,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 10 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 2,  Length of Maximum Span: 41.1m (134.8ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 13.1m (43.0ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 43.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 17.50m (57.41ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $98,000,  Roadway Improvement Cost: $288,000,  Total Project Cost: $1,321,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 857,  Location: I-79 SB OVER SR 50 (Lat: 40.366667,  Lng: -80.125000),  Route carried "on" structure: Interstate 79,  Year Built: 1965,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 5.70m (18.70ft),  Average Daily Traffic: 43,660 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 28,273 (year 2032),  Design Load: HS 20,  Features Intersected: SR 0050,  Facility Carried by Structure: RAYMOND SHAFER HW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.637,  Lanes on structure: 3,  Lanes under structure: 10,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 14 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 33.5m (109.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 15.2m (49.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 78.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 4.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: High priority of corrective action,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.70m (18.70ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $39,000,  Roadway Improvement Cost: $157,000,  Total Project Cost: $522,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 858,  Location: 500'NORTH OF TR 50 (Lat: 40.358642,  Lng: -80.118969),  Route carried "on" structure: Interstate 79,  Year Built: 1965,  Year Reconstructed: 1998,  Status: Open,  Structure Length: 17.62m (57.81ft),  Average Daily Traffic: 43,660 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 28,273 (year 2032),  Design Load: HS 20,  Features Intersected: W&LE RR,CHARTIERS CREEK,  Facility Carried by Structure: RAYMOND SHAFER HW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 4.637,  Lanes on structure: 3,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 10 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 2,  Length of Maximum Span: 40.2m (131.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 14.8m (48.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 70.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 17.60m (57.74ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $61,000,  Roadway Improvement Cost: $181,000,  Total Project Cost: $828,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 86,  Location: 1016NB OVER CHARTIERS CRK (Lat: 40.372314,  Lng: -80.109344),  Route carried "on" structure: Interstate 79,  Year Built: 1965,  Year Reconstructed: 2005,  Status: Open,  Structure Length: 7.77m (25.49ft),  Average Daily Traffic: 31,325 (year 2021),  Truck Traffic: 15%,  Average Future Daily Traffic: 29,322 (year 2032),  Design Load: HS 20,  Features Intersected: CHARTIERS CREEK,  Facility Carried by Structure: RAYMOND SHAFER HW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.049,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 18.6m (61.0ft),  Skew: 10 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 29.9m (98.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 17.5m (57.4ft),  Out-to-Out Width: 18.5m (60.7ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 72.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.80m (25.59ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1348,  Location: 539' NORTH OF SR 3026 (Lat: 40.349692,  Lng: -80.164481),  Route carried "on" structure: State highway 978,  Year Built: 1929,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 3,480 (year 2022),  Truck Traffic: 6%,  Average Future Daily Traffic: 3,363 (year 2032),  Design Load: HS 20,  Features Intersected: DOLPHIN RUN,  Facility Carried by Structure: BATTLE RIDGE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.334,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.1m (33.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 84.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 50.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.80m (2.62ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2020,  Bridge Improvement Cost: $20,000,  Roadway Improvement Cost: $58,000,  Total Project Cost: $267,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1692,  Location: 1/2 MI.E.OF BOWER HILL RD (Lat: 40.354128,  Lng: -80.100358),  Route carried "on" structure: State highway ,  Year Built: 1900,  Year Reconstructed: 1950,  Status: Posted for load,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 4,921 (year 2022),  Truck Traffic: 8%,  Average Future Daily Traffic: 8,154 (year 2032),  Design Load: HS 20,  Features Intersected: MCLAUGHLIN RUN,  Facility Carried by Structure: MCLAUGHLIN RUN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.805,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.8m (32.2ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Poor,  Channel: Poor,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 19.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 10.0 - 19.9% below),  Length Of Structure Improvement: 1.70m (5.58ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: May 2021,  Other Special Inspection Date: May 2021,  Bridge Improvement Cost: $14,000,  Roadway Improvement Cost: $41,000,  Total Project Cost: $188,000,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1739,  Location: 400' NORTHWEST OF SR 0050 (Lat: 40.358436,  Lng: -80.128369),  Route carried "on" structure: State highway ,  Year Built: 2000,  Status: Open,  Structure Length: 2.26m (7.41ft),  Average Daily Traffic: 5,109 (year 2021),  Truck Traffic: 14%,  Average Future Daily Traffic: 9,042 (year 2032),  Design Load: HS 20,  Features Intersected: MILLER'S RUN,  Facility Carried by Structure: MILLER'S RUN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.322,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 22.3m (73.2ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 12.7m (41.7ft),  Out-to-Out Width: 13.6m (44.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 2.30m (7.55ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1746,  Location: INTERSECTI THOMS RUN RD (Lat: 40.372303,  Lng: -80.120569),  Route carried "on" structure: State highway ,  Year Built: 1935,  Year Reconstructed: 2012,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 5,038 (year 2022),  Truck Traffic: 5%,  Average Future Daily Traffic: 4,962 (year 2032),  Design Load: HL 93,  Features Intersected: THOMS RUN,  Facility Carried by Structure: PRESTO SYGAN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.160,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 12.0m (39.4ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.8 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 34.7 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.60m (1.97ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Bridge Improvement Cost: $7,000,  Roadway Improvement Cost: $26,000,  Total Project Cost: $97,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1749,  Location: @ INTER.W/THOMS RUN RD. (Lat: 40.374492,  Lng: -80.114836),  Route carried "on" structure: State highway ,  Year Built: 1956,  Status: Open,  Structure Length: 4.75m (15.58ft),  Average Daily Traffic: 6,888 (year 2022),  Truck Traffic: 9%,  Average Future Daily Traffic: 7,454 (year 2032),  Design Load: HL 93,  Features Intersected: CHARTIERS CREEK,  Facility Carried by Structure: PRESLEY RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.411,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 2 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 22.9m (75.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Very good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 73.5 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.80m (15.75ft),  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: May 2021,  Underwater Inspection Date: September 2021,  Bridge Improvement Cost: $25,000,  Roadway Improvement Cost: $74,000,  Total Project Cost: $339,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 2249,  Location: PA06 PAINTERS RUN NO. 6 (Lat: 40.362300,  Lng: -80.095986),  Route carried "on" structure: County highway ,  Year Built: 1934,  Status: Open,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 15,049 (year 2005),  Truck Traffic: 5%,  Average Future Daily Traffic: 19,108 (year 2023),  Features Intersected: PAINTERS RUN,  Facility Carried by Structure: BOWER HILL RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft)

Condition: Channel: Poor,  Culverts: Satisfactory,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 0.60m (1.97ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 256,  Location: ML06 MCLAUGHLIN RUN # 6 (Lat: 40.357625,  Lng: -80.105678),  Route carried "on" structure: City street ,  Year Built: 1935,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 3,155 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,500 (year 2023),  Features Intersected: MC LAUGHLIN RUN,  Facility Carried by Structure: BALDWIN ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 1.2m (3.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 11.6m (38.1ft)

Condition: Superstructure: Fair,  Substructure: Fair,  Channel: Poor,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 2.00m (6.56ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Bridge Improvement Cost: $9,000,  Roadway Improvement Cost: $50,000,  Total Project Cost: $125,000
Find on map >>   Show street view

Structure Number: 4688,  Location: 1 MI.W.OF LEHIGH CO.LINE (Lat: 40.577939,  Lng: -75.749331),  Route carried "on" structure: Interstate 78,  Year Built: 1958,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 41,403 (year 2022),  Truck Traffic: 29%,  Average Future Daily Traffic: 50,359 (year 2032),  Design Load: HL 93,  Features Intersected: MILL CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 55.790,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 25.6m (84.0ft),  Skew: 31 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.5m (27.9ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.50m (4.92ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2019
Find on map >>   Show street view

Structure Number: 4015,  Location: 500 FT SOUTHEAST OF SR 50 (Lat: 40.354606,  Lng: -80.112419),  Route carried "on" structure: State highway ,  Year Built: 1998,  Status: Open,  Structure Length: 2.80m (9.19ft),  Average Daily Traffic: 8,404 (year 2022),  Truck Traffic: 3%,  Average Future Daily Traffic: 8,588 (year 2032),  Design Load: HS 20,  Features Intersected: PGH AND OHIO RAILWAY,  Facility Carried by Structure: CHARTIERS STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 27.4m (89.9ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Inventory Rating: 39.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.40m (11.15ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 40426,  Location: 102001 300' E OF WASH RD (Lat: 40.367461,  Lng: -80.100464),  Route carried "on" structure: City street ,  Year Built: 1999,  Status: Open,  Structure Length: 2.99m (9.81ft),  Average Daily Traffic: 1,200 (year 2019),  Truck Traffic: 10%,  Average Future Daily Traffic: 1,250 (year 2041),  Design Load: HS 20,  Features Intersected: WHEELING & LAKE ERIE RR,  Facility Carried by Structure: BERAM AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 29.6m (97.1ft),  Curb or Sidewalk Widths: Left: 1.7m (5.6ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 8.6m (28.2ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.00m (9.84ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 44993,  Location: BRIDGEVILLE INTERCHANGE (Lat: 40.358203,  Lng: -80.118347),  Route carried "on" structure: Ramp State highway ,  Year Built: 2008,  Status: Open,  Structure Length: 17.25m (56.59ft),  Average Daily Traffic: 5,748 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 15,208 (year 2032),  Design Load: HS 20,  Features Intersected: Chartiers Creek, WERR,  Facility Carried by Structure: RAMP F
Minimum Vertical Clearance: 7.01m (23.00ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 54.9m (180.1ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Excellent,  Operating Rating: 95.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 57.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4561,  Location: 0.7 MI W OF SR0050 (Lat: 40.353889,  Lng: -80.138056),  Route carried "on" structure: State highway ,  Year Built: 2009,  Status: Open,  Structure Length: 5.94m (19.49ft),  Average Daily Traffic: 4,153 (year 2022),  Truck Traffic: 7%,  Average Future Daily Traffic: 4,411 (year 2032),  Design Load: HS 20,  Features Intersected: MILLER'S RUN,  Facility Carried by Structure: MILLER'S RUN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.649,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 58.8m (192.9ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Inventory Rating: 63.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 4688,  Location: 1/2 MI. S.E. OF SR 50 (Lat: 40.355678,  Lng: -80.106564),  Route carried "on" structure: State highway ,  Year Built: 2011,  Status: Open,  Structure Length: 1.46m (4.79ft),  Average Daily Traffic: 4,921 (year 2022),  Truck Traffic: 8%,  Average Future Daily Traffic: 8,154 (year 2032),  Design Load: HL 93,  Features Intersected: MCLAUGHLIN RUN,  Facility Carried by Structure: MCLAUGHLIN RUN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.7m (44.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 7.4m (24.3ft),  Out-to-Out Width: 11.0m (36.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 55.4 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 53204,  Location: 100' SW of Thoms Run Rd (Lat: 40.373606,  Lng: -80.133047),  Route carried "on" structure: City street ,  Year Built: 1990,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 25 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 30 (year 2039),  Design Load: HS 20,  Features Intersected: Thoms Run,  Facility Carried by Structure: Bridge St.
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 4.9m (16.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 3.4m (11.2ft),  Out-to-Out Width: 3.8m (12.5ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Channel: Fair,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 34.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 854,  Location: I 79 NB OVER SR 50 (Lat: 40.356158,  Lng: -80.118247),  Route carried "under" structure: State highway 50,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 15,586 (year 2022),  Truck Traffic: 4%,  Features Intersected: SR 0050,  Facility Carried by Structure: RAYMOND SHAFER HW
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 6.685,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 854,  Location: I 79 NB OVER SR 50 (Lat: 40.356158,  Lng: -80.118247),  Route carried "under" structure: State highway 50,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 17,218 (year 2022),  Truck Traffic: 6%,  Features Intersected: SR 0050,  Facility Carried by Structure: RAYMOND SHAFER HW
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 6.737,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 857,  Location: I-79 SB OVER SR 50 (Lat: 40.366667,  Lng: -80.125000),  Route carried "under" structure: State highway 50,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 17,218 (year 2022),  Truck Traffic: 6%,  Features Intersected: SR 0050,  Facility Carried by Structure: RAYMOND SHAFER HW
Minimum Vertical Clearance: 4.50m (14.76ft),  Kilometerpoint: 6.737,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 857,  Location: I-79 SB OVER SR 50 (Lat: 40.366667,  Lng: -80.125000),  Route carried "under" structure: State highway 50,  Year Built: 1965,  Structure Length: 0. m,  Average Daily Traffic: 15,586 (year 2022),  Truck Traffic: 4%,  Features Intersected: SR 0050,  Facility Carried by Structure: RAYMOND SHAFER HW
Minimum Vertical Clearance: 4.60m (15.09ft),  Kilometerpoint: 6.685,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 1748,  Location: 4400' N.W. OF SR 0050 (Lat: 40.372311,  Lng: -80.113511),  Route carried "under" structure: Interstate 79,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 31,325 (year 2021),  Truck Traffic: 15%,  Features Intersected: SR 0079 NB SB,  Facility Carried by Structure: PRESTLEY RD.
Minimum Vertical Clearance: 5.79m (19.00ft),  Kilometerpoint: 6.244,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 26.5m (86.9ft)

Find on map >>   Show street view

Structure Number: 1748,  Location: 4400' N.W. OF SR 0050 (Lat: 40.372311,  Lng: -80.113511),  Route carried "under" structure: Interstate 79,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 43,660 (year 2021),  Truck Traffic: 15%,  Features Intersected: SR 0079 NB SB,  Facility Carried by Structure: PRESTLEY RD.
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 6.268,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 26.5m (86.9ft)

Find on map >>   Show street view

Structure Number: 2747,  Location: HEIDELBERG EXIT (Lat: 40.375000,  Lng: -80.100000),  Route carried "under" structure: Interstate 79,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 44,403 (year 2021),  Truck Traffic: 20%,  Features Intersected: SR 0079 NB-SB,  Facility Carried by Structure: SR 8005 RAMP AB
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 7.049,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 26.2m (86.0ft)

Find on map >>   Show street view

Structure Number: 2747,  Location: HEIDELBERG EXIT (Lat: 40.375000,  Lng: -80.100000),  Route carried "under" structure: Interstate 79,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 43,560 (year 2021),  Truck Traffic: 24%,  Features Intersected: SR 0079 NB-SB,  Facility Carried by Structure: SR 8005 RAMP AB
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 7.126,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 26.2m (86.0ft)

Find on map >>   Show street view

Structure Number: 2747,  Location: HEIDELBERG EXIT (Lat: 40.375000,  Lng: -80.100000),  Route carried "under" structure: Ramp State highway 79,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 6,000 (year 1996),  Truck Traffic: 1%,  Features Intersected: SR 0079 NB-SB,  Facility Carried by Structure: SR 8005 RAMP AB
Minimum Vertical Clearance: 5.56m (18.24ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 7,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 26.2m (86.0ft)

Discuss Bridgeville, Pennsylvania (PA) on our hugely popular Pennsylvania forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.