The mobile unit is not approved.
- Nonfood-Contact Surfaces/Nonabsorbent
Observation: The nonfood-contact surface of the raw wood under the 3 compartment sink is not corrosion-resistant, nonabsorbent, and/or smooth.
Correction: Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that requires frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material. Nonfood-contact surfaces of equipment routinely exposed to splash or food debris are required to be constructed of nonabsorbent materials to facilitate cleaning. Equipment that is easily cleaned minimizes the presence of pathogenic organisms, moisture, and debris and deters the attraction of rodents and insects.
- Ventilation Hood-Systems, Drip Prevention/Functionality
Observation: A grease/oil drip pan was not provided.
Correction: Exhaust ventilation hood systems in food preparation and warewashing areas including components such as hoods, fans, guards, and ducting shall be designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, single-service and single-use articles. The dripping of grease or condensation onto food constitutes adulteration and may involve contamination of the food with pathogenic organisms. Equipment, utensils, linens, and single service and single use articles that are subjected to such drippage are no longer clean.
- Equipment/Fixed, Spacing or Sealing
Observation: The 3 compartment sink is not sealed to the adjoining wall.
Correction: Equipment that is fixed because it is not easily movable shall be installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, and above the equipment
- Water/Pressure/Quantity and Availability
Observation: Water under pressure is not provided to the handwashing sink.
Correction: Water under pressure shall be provided to all fixtures, equipment, and nonfood equipment that are required to use water except that water supplied as specified under paragraphs 5-104.12(A) and (B) to a temporary food establishment or in response to a temporary interruption of a water supply need not be under pressure. Inadequate water pressure could lead to situations that place the public health at risk. For example, inadequate pressure could result in improper handwashing or equipment operation. Sufficient water pressure ensures that equipment such as mechanical warewashers operate according to manufacturer's specifications.
- Plumbing System/Maintained in Good Repair
Observation: The waste tank and 3 compartment sink were observed leaking and not maintained in good repair.
Correction: A plumbing system shall be maintained in good repair. Improper repair or maintenance may result in the creation of obnoxious odors or nuisances, and may also adversely affect the operation of warewashing equipment or other equipment which depends on sufficient volume and pressure to perform its intended functions.
- Handwashing Signage
Observation: A sign or poster that notifies food employees to wash their hands is not provided at all handwashing lavatories used by food employees and/or is not clearly visible to food employees.
Correction: A sign or poster that notifies food employees to wash their hands shall be provided at all handwashing sinks used by food employees and shall be clearly visible to food employees. A sign or poster is required to remind food employees to wash their hands.
|
10/10/2014 | Pre-Opening | |