C.O. not approved
- Equipment and Utensils/Durability and Strength
Observation: The "GE" refrigerators in the classrooms are not designed and constructed to be durable.
Correction: Equipment and utensils shall be designed and constructed to be durable and to retain their characteristic qualities under normal use conditions. Equipment and utensils must be designed and constructed to be durable and capable of retaining their original characteristics so that such items can continue to fulfill their intended purpose for the duration of their life expectancy and to maintain their easy cleanability. If they can not maintain their original characteristics, they may become difficult to clean, allowing for the harborage of pathogenic microorganisms, insects, and rodents. Equipment and utensils must be designed and constructed so that parts do not break and end up in food as foreign objects or present injury hazards to consumers. A common example of presenting an injury hazard is the tendency for tines of poorly designed single service forks to break during use.
- Food Temperature Measuring Devices
Observation: A food temperature measuring device is not provided and readily accessible for use in ensuring attainment and maintenance of food temperatures.
Correction: Food temperature measuring devices shall be provided and readily accessible for use in ensuring attainment and maintenance of food temperatures as specified under Chapter 3. The presence and accessibility of food temperature measuring devices is critical to the effective monitoring of food temperatures. Proper use of such devices provides the operator or person in charge with important information with which to determine if temperatures should be adjusted or if foods should be discarded.
- Sanitizing Solutions, Testing Devices
Observation: A test kit or other device that accurately measures the concentration of the sanitizing solution is not provided.
Correction: A test kit or other device that accurately measures the concentration in mg/L of sanitizing solutions shall be provided. Testing devices to measure the concentration of sanitizing solutions are required for 2 reasons: 1. The use of chemical sanitizers requires minimum concentrations of the sanitizer during the final rinse step to ensure sanitization
- Equipment/Fixed, Spacing or Sealing
Observation: The counter-mounted pantry three compartment sink and counter that are not easily movable were not installed to allow cleaning of the equipment and areas underneath and around it.
Correction: Counter-mounted equipment that is not easily movable shall be installed to allow cleaning of the equipment and areas underneath and around the equipment by being: (1) Sealed
- Equipment/Good Repair and Proper Adjustment
Observation: The pantry wall shelving with it's protective liner is not maintained in a state of repair and condition that meets the requirements of materials for construction and repair and/or design.
Correction: Equipment shall be maintained in a state of repair and condition that meets the requirements specified under Parts 4-1 [Materials for Construction and Repair] and 4-2 [Design and Construction]. Proper maintenance of equipment to manufacturer specifications helps ensure that it will continue to operate as designed. Failure to properly maintain equipment could lead to violations of the associated requirements of the Code that place the health of the consumer at risk. For example, refrigeration units in disrepair may no longer be capable of properly cooling or holding potentially hazardous (time/temperature control for safety) foods at safe temperatures.
- Critical: Equipment/Food-Contact/Before Use After Cleaning/Sanitized
Observation: There is no sanitizer on-site.
Correction: Utensils and food-contact surfaces of equipment shall be sanitized before use after cleaning. Sanitization is accomplished after the warewashing steps of cleaning and rinsing so that utensils and food-contact surfaces are sanitized before coming in contact with food and before use.
- Critical: Sanitized/Hot Water and Chemical/Methods
Observation: After being cleaned, equipment food-contact surfaces and utensils are not sanitized in the hot water mechanical operations by being cycled through equipment that is properly set up and/or achieving a utensil surface temperature of 160°F as measured by an irreversible registering temperature indicator.
Correction: After being cleaned, equipment food-contact surfaces and utensils shall be sanitized in hot water mechanical operations by being cycled through equipment that is set up as specified under sections 4-501.15, 4-501.112, and 4-501.113 and achieving a utensil surface temperature of 71°C (160°F) as measured by an irreversible registering temperature indicator. When surface temperatures of utensils passing through warewashing machines using hot water for sanitizing do not reach the required 71°C (160°F), it is important to understand the factors affecting the decreased surface temperature. A comparison should be made between the machine manufacturer's operating instructions and the machine's actual wash and rinse temperatures and final rinse pressure. The actual temperatures and rinse pressure should be consistent with the machine manufacturer's operating instructions and within limits specified in sections 4-501.112 and 4-501.113. If either the temperature of pressure of the final rinse spray is higher than the specified upper limit, spray droplets may disperse and begin to vaporize resulting in less heat delivery to utensil surfaces. Temperatures below the specified limit will not convey the needed heat to surfaces. Pressures below the specified limit will result in incomplete coverage of the heat-conveying sanitizing rinse across utensil surfaces.
- Refuse/Toilet Room Receptacle, Covered
Observation: There are no covered receptacles in the toilet rooms used by females.
Correction: A toilet room used by females shall be provided with a covered receptacle for sanitary napkins. Garbage containers should be available wherever garbage is generated to aid in the proper disposal of refuse.
- Floors, Walls, and Ceilings/Cleanability
Observation: The wall by the entrance door and the ceiling surfaces of the pantry and rest-rooms are not designed, constructed, and installed so that it is smooth and easily cleanable.
Correction: Floors, floor coverings, walls, wall coverings, and ceilings shall be designed, constructed and installed so that they are smooth and easily cleanable except for anti-slip floor coverings or applications that may be used for safety reasons and except as specified under section 6-201.14. Floors that are of smooth, durable construction and that are nonabsorbent are more easily cleaned. Requirements and restrictions regarding floor coverings, utility lines, and floor/wall junctures are intended to ensure that regular and effective cleaning is possible and that insect and rodent harborage is minimized.
- Floor and Wall Junctures, Coved, Enclosed or Sealed
Observation: The floor and wall juncture is not coved and closed to larger than one thirty-second inch in the Pre-K closet.
Correction: In food establishments in which cleaning methods other than water flushing are used for cleaning floors, the floor and wall junctures shall be coved and closed to no larger than 1 mm (one thirty-second inch). When cleaning is accomplished by spraying or flushing, coving and sealing of the floor/wall junctures is required to provide a surface that is conducive to water flushing.
- Toilet Rooms, Enclosed
Observation: The toilet rooms are not completely enclosed and/or provided with a tight-fitting and/or self-closing doors.
Correction: Except where a toilet room is located outside a food establishment and does not open directly into the food establishment such as a toilet room that is provided by the management of a shopping mall, a toilet room located on the premises shall be completely enclosed and provided with a tight-fitting and self-closing door. Completely enclosed toilet facilities minimize the potential for the spread of disease by the movement of flies and other insects between the toilet facility and food preparation areas.
- Handwashing Cleanser, Availability
Observation: A supply of hand cleaning liquid, powder, or bar soap is not provided at each handwashing sink.
Correction: Each handwashing sink or group of 2 adjacent handwashing sinks shall be provided with a supply of hand cleaning liquid, powder, or bar soap. Hand cleanser must always be present to aid in reducing microorganisms and particulate matter found on hands.
- Hand Drying Provision
Observation: Each handwashing sink is not provided with individual, disposable towels
Correction: a continuous towel system that supplies the user with a clean towel
- Handwashing Aids and Devices, Use Restrictions
Observation: Handwashing aids and devices are provided at the pantry three compartment sink used for food preparation or utensil washing.
Correction: A sink used for food preparation or utensil washing, or a service sink or curbed cleaning facility used for the disposal of mop water or similar wastes, may not be provided with the handwashing aids and devices required for a handwashing sink.
- Handwashing Signage
Observation: A sign or poster that notifies food employees to wash their hands is not provided at all handwashing lavatories used by food employees and/or is not clearly visible to food employees (pantry).
Correction: A sign or poster that notifies food employees to wash their hands shall be provided at all handwashing sinks used by food employees and shall be clearly visible to food employees. A sign or poster is required to remind food employees to wash their hands.
- Physical Facilities/Repairing
Observation: There are some holes/openings in the walls and ceiling of the water heater closet and Pre-K closet.
Correction: Physical facilities shall be maintained in good repair. Poor repair and maintenance compromises the functionality of the physical facilities. This requirement is intended to ensure that the physical facilities are properly maintained in order serve their intended purpose.
|