Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Wilmette, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 10Number of bridges
  • 135ft / 40.5mTotal length
  • $3,837,000Total costs
  • 403,125Total average daily traffic
  • 23,865Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Wilmette
  • No street view available for this location

New bridges in Wilmette, IL - historical statistics
  • New bridges - historical statistics
  • 21900-1909
  • 11910-1919
  • 41940-1949
  • 21950-1959
  • 12010-2019
Reconstructed bridges in Wilmette, IL - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21970-1979
  • 11980-1989
Average Bridge Daily Traffic in Wilmette, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 14.3%Very good
  • 28.6%Good
  • 28.6%Satisfactory
  • 14.3%Fair
  • 14.3%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 14.3%Very good
  • 71.4%Fair
  • 14.3%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 14.3%Very good
  • 14.3%Good
  • 42.9%Satisfactory
  • 28.6%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 75.0%Very good
  • 25.0%Good
Find on map >>   Show street view

Structure Number: 160167,  Location: 0.9 M S WILLOW RD (Lat: 42.084953,  Lng: -87.758617),  Route carried "on" structure: Other road ,  Year Built: 1949,  Year Reconstructed: 1983,  Status: Open,  Structure Length: 9.06m (29.72ft),  Average Daily Traffic: 10,300 (year 2021),  Truck Traffic: 2%,  Average Future Daily Traffic: 9,270 (year 2032),  Design Load: HS 20+Mod,  Features Intersected: I- 94 EDENS,  Facility Carried by Structure: US 41 SB RAMP SKOK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.418,  Lanes on structure: 2,  Lanes under structure: 6,  Base Highway Network: Yes (Inventory Route: 10094040,  Subroute: 30),  Owner: State Highway Agency,  Approaching Roadway Width: 6.4m (21.0ft),  Skew: 4 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 24.8m (81.4ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Poor,  Superstructure: Serious,  Substructure: Good,  Operating Rating: 72.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Length Of Structure Improvement: 8.96m (29.40ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $512,000,  Roadway Improvement Cost: $51,000,  Total Project Cost: $845,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 160545,  Location: 2.7 M N IL 58 (Lat: 42.079517,  Lng: -87.759042),  Route carried "on" structure: Other road ,  Year Built: 1950,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 6.91m (22.67ft),  Average Daily Traffic: 21,700 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 23,175 (year 2032),  Design Load: HS 20,  Features Intersected: I- 94 EDENS,  Facility Carried by Structure: LAKE AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 25.829,  Lanes on structure: 5,  Lanes under structure: 8,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 19.2m (63.0ft),  Skew: 30 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.2m (63.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 21.0m (68.9ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 49.6 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 16062,  Location: 2.5 M N ILL 58 P12 (Lat: 42.075703,  Lng: -87.685414),  Route carried "on" structure: Other road ,  Year Built: 1911,  Status: Open,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 10,500 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 9,682 (year 2032),  Design Load: H 15,  Features Intersected: N SHORE CHANNEL,  Facility Carried by Structure: SHERIDAN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.217,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: Local Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 23.5m (77.1ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 14.0m (45.9ft),  Out-to-Out Width: 19.3m (63.3ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 33.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 17.2 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.68m (25.20ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Bridge Improvement Cost: $1,757,000,  Roadway Improvement Cost: $176,000,  Total Project Cost: $2,636,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 160821,  Location: 2 M N IL 58 (Lat: 42.068628,  Lng: -87.756614),  Route carried "on" structure: Other road ,  Year Built: 1949,  Year Reconstructed: 1984,  Status: Open,  Structure Length: 7.06m (23.16ft),  Average Daily Traffic: 2,425 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 10,403 (year 2032),  Design Load: HS 20,  Features Intersected: I- 94 EDENS,  Facility Carried by Structure: GLENVIEW RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 9.237,  Lanes on structure: 4,  Lanes under structure: 6,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 19.5m (64.0ft),  Curb or Sidewalk Widths: Left: 1.4m (4.6ft),  Right: 1.4m (4.6ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 65.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 7.10m (23.29ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Bridge Improvement Cost: $297,000,  Roadway Improvement Cost: $15,000,  Total Project Cost: $356,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 163056,  Location: 0.5 Mi S of Winnetka (Lat: 42.086550,  Lng: -87.766300),  Route carried "on" structure: Other road ,  Year Built: 2017,  Status: Open,  Structure Length: 2.29m (7.51ft),  Average Daily Traffic: 4,100 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 3,399 (year 2032),  Design Load: HS 25 or greater,  Features Intersected: Skokie River,  Facility Carried by Structure: Happ Road
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.837,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 2,  Length of Maximum Span: 8.2m (26.9ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 0.0m,  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 72.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 56.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: November 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 169958,  Location: WILMETTE (Lat: 42.073725,  Lng: -87.687797),  Route carried "on" structure: City street ,  Year Built: 1909,  Status: Open,  Structure Length: 4.39m (14.40ft),  Average Daily Traffic: 1,400 (year 2018),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,039 (year 2032),  Features Intersected: N SHORE CHANNEL,  Facility Carried by Structure: LINDEN AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.979,  Lanes on structure: 2,  Owner: Local Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.6m (70.9ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 1.9m (6.2ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Critical Feature Inspection Date: December 2021,  Deck Structure Type: Open Grating,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 169959,  Location: WILMETTE (Lat: 42.071186,  Lng: -87.686672),  Route carried "on" structure: City street ,  Year Built: 1909,  Status: Open,  Structure Length: 4.39m (14.40ft),  Average Daily Traffic: 200 (year 2018),  Truck Traffic: 14%,  Average Future Daily Traffic: 412 (year 2032),  Features Intersected: N SHORE CHANNEL,  Facility Carried by Structure: MAPLE AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.885,  Lanes on structure: 2,  Owner: Local Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.6m (70.9ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 1.9m (6.2ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 11.8m (38.7ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 45.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.1 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: December 2021,  Critical Feature Inspection Date: December 2021,  Deck Structure Type: Open Grating,  Wearing Surface/Protective System: Wearing Surface: Other
Find on map >>   Show street view

Structure Number: 160167,  Location: 0.9 M S WILLOW RD (Lat: 42.084953,  Lng: -87.758617),  Route carried "under" structure: Interstate 94,  Year Built: 1949,  Structure Length: 0. m,  Average Daily Traffic: 118,100 (year 2021),  Truck Traffic: 6%,  Features Intersected: I- 94 EDENS,  Facility Carried by Structure: US 41 SB RAMP SKOK
Minimum Vertical Clearance: 4.65m (15.26ft),  Kilometerpoint: 55.054,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 24.8m (81.4ft)

Find on map >>   Show street view

Structure Number: 160545,  Location: 2.7 M N IL 58 (Lat: 42.079514,  Lng: -87.758703),  Route carried "under" structure: Interstate 94,  Year Built: 1950,  Structure Length: 0. m,  Average Daily Traffic: 112,700 (year 2021),  Truck Traffic: 7%,  Features Intersected: I- 94 EDENS,  Facility Carried by Structure: LAKE AVE
Minimum Vertical Clearance: 4.22m (13.85ft),  Kilometerpoint: 55.650,  Lanes on structure: 5,  Lanes under structure: 8,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.2m (63.0ft)

Find on map >>   Show street view

Structure Number: 160821,  Location: 2 M N IL 58 (Lat: 42.068628,  Lng: -87.756614),  Route carried "under" structure: Interstate 94,  Year Built: 1949,  Structure Length: 0. m,  Average Daily Traffic: 121,700 (year 2021),  Truck Traffic: 6%,  Features Intersected: I- 94 EDENS,  Facility Carried by Structure: GLENVIEW RD
Minimum Vertical Clearance: 4.57m (14.99ft),  Kilometerpoint: 56.889,  Lanes on structure: 4,  Lanes under structure: 6,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.5m (64.0ft)

Discuss Wilmette, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.