Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Westbrook, Connecticut (CT)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 22Number of bridges
  • 200ft / 61.0mTotal length
  • $8,750,000Total costs
  • 478,255Total average daily traffic
  • 49,091Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Westbrook
  • No street view available for this location

New bridges in Westbrook, CT - historical statistics
  • New bridges - historical statistics
  • 1Before 1900
  • 21930-1939
  • 101950-1959
  • 11970-1979
  • 11980-1989
  • 51990-1999
  • 22010-2019
Reconstructed bridges in Westbrook, CT - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11950-1959
  • 21960-1969
  • 01970-1979
  • 11980-1989
  • 11990-1999
Average Bridge Daily Traffic in Westbrook, CT
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 5.9%Very good
  • 41.2%Good
  • 23.5%Satisfactory
  • 23.5%Fair
  • 5.9%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 11.8%Very good
  • 29.4%Good
  • 29.4%Satisfactory
  • 23.5%Fair
  • 5.9%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 11.8%Very good
  • 52.9%Good
  • 29.4%Satisfactory
  • 5.9%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 44.4%Very good
  • 44.4%Good
  • 11.1%Satisfactory
Find on map >>   Show street view

Structure Number: 23,  Location: INTERSTATE-95 EXIT NO. 6 (Lat: 41.044522,  Lng: -73.558436),  Route carried "on" structure: Interstate 95,  Year Built: 1958,  Year Reconstructed: 1995,  Status: Open,  Structure Length: 2.04m (6.69ft),  Average Daily Traffic: 122,700 (year 2017),  Truck Traffic: 10%,  Average Future Daily Traffic: 182,320 (year 2037),  Design Load: H 20,  Features Intersected: WEST AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 10.654,  Lanes on structure: 6,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 36.0m (118.1ft),  Skew: 30 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 19.2m (63.0ft),  Curb-To-Curb Width: 36.0m (118.1ft),  Out-to-Out Width: 38.9m (127.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 87.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 52.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 227,  Location: 0.3 MI N OF ROUTE 145 (Lat: 41.292444,  Lng: -72.493400),  Route carried "on" structure: City street ,  Year Built: 1957,  Year Reconstructed: 1972,  Status: Open,  Structure Length: 4.75m (15.58ft),  Average Daily Traffic: 264 (year 2020),  Truck Traffic: 4%,  Average Future Daily Traffic: 392 (year 2040),  Design Load: HS 20,  Features Intersected: INTERSTATE-95,  Facility Carried by Structure: CHAPMAN MILLPOND R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.370,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 22.9m (75.1ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 36.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 28.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 228,  Location: 2.4 MI S OF ROUTE 153 (Lat: 41.293986,  Lng: -72.488567),  Route carried "on" structure: State highway 145,  Year Built: 1957,  Status: Open,  Structure Length: 4.51m (14.80ft),  Average Daily Traffic: 9,500 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 14,116 (year 2036),  Design Load: HS 20,  Features Intersected: INTERSTATE-95
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.154,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 21.6m (70.9ft),  Curb or Sidewalk Widths: Left: 0.5m (1.6ft),  Right: 0.5m (1.6ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.9m (45.6ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 40.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 229,  Location: 1.7 MI N OF US ROUTE 145 (Lat: 41.291650,  Lng: -72.456078),  Route carried "on" structure: Interstate 95,  Year Built: 1957,  Status: Open,  Structure Length: 1.68m (5.51ft),  Average Daily Traffic: 60,500 (year 2015),  Truck Traffic: 10%,  Average Future Daily Traffic: 89,897 (year 2035),  Design Load: H 20,  Features Intersected: POND MEADOW ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 116.677,  Lanes on structure: 4,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 28.4m (93.2ft),  Skew: 31 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 15.2m (49.9ft),  Curb-To-Curb Width: 28.4m (93.2ft),  Out-to-Out Width: 31.5m (103.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 23,  Location: 2.0 MI N OF ROUTE 145 (Lat: 41.292072,  Lng: -72.450692),  Route carried "on" structure: City street ,  Year Built: 1958,  Status: Open,  Structure Length: 5.37m (17.62ft),  Average Daily Traffic: 2,455 (year 2021),  Truck Traffic: 4%,  Average Future Daily Traffic: 3,648 (year 2041),  Design Load: H 20,  Features Intersected: INTERSTATE-95,  Facility Carried by Structure: WILLARD AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.789,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.4m (57.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Satisfactory,  Operating Rating: 50.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Total Project Cost: $2,450,000 ( Estimate for 2018),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 232,  Location: I-95 EXIT NO. 65 (Lat: 41.291733,  Lng: -72.443811),  Route carried "on" structure: State highway 153,  Year Built: 1957,  Status: Open,  Structure Length: 5.46m (17.91ft),  Average Daily Traffic: 12,200 (year 2016),  Truck Traffic: 5%,  Average Future Daily Traffic: 18,128 (year 2036),  Design Load: H 20,  Features Intersected: INTERSTATE-95
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.789,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 26.2m (86.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.6m (5.2ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Satisfactory,  Operating Rating: 86.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Total Project Cost: $6,300,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 666,  Location: 1 MILE NORTH OF ROUTE 201 (Lat: 41.620294,  Lng: -71.975314),  Route carried "on" structure: State highway 12,  Year Built: 1930,  Year Reconstructed: 1986,  Status: Open,  Structure Length: 6.21m (20.37ft),  Average Daily Traffic: 4,800 (year 2017),  Truck Traffic: 5%,  Average Future Daily Traffic: 7,132 (year 2037),  Design Load: HS 20,  Features Intersected: PROV & WORC RAILROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 35.422,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.2m (26.9ft),  Skew: 6 degrees,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 21.5m (70.5ft),  Curb-To-Curb Width: 8.2m (26.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 43.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Critical Feature Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1385,  Location: 0.3 MI S OF I-95 (Lat: 41.288878,  Lng: -72.446972),  Route carried "on" structure: State highway 153,  Year Built: 1933,  Year Reconstructed: 1963,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 11,600 (year 2018),  Truck Traffic: 3%,  Average Future Daily Traffic: 17,236 (year 2038),  Design Load: HS 20,  Features Intersected: AMTRAK RAILROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.386,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 9.4m (30.8ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.4m (34.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 1.3m (4.3ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 12.6m (41.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 68.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 3527,  Location: 0.2 MI N OF US ROUTE 1 (Lat: 41.277647,  Lng: -72.485339),  Route carried "on" structure: State highway 625,  Year Built: 1890,  Year Reconstructed: 1968,  Status: Open,  Structure Length: 1.04m (3.41ft),  Average Daily Traffic: 5,000 (year 2016),  Truck Traffic: 3%,  Average Future Daily Traffic: 7,430 (year 2036),  Design Load: HS 20,  Features Intersected: AMTRAK RAILROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.354,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Operating Rating: 74.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 44.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of replacement,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 4807,  Location: 750 FEET N OF U.S.ROUTE 1 (Lat: 41.287800,  Lng: -72.451556),  Route carried "on" structure: City street ,  Year Built: 1976,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 3,305 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 4,911 (year 2040),  Design Load: HS 20,  Features Intersected: PATCHOGUE RIVER,  Facility Carried by Structure: OLD CLINTON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.306,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.6m (38.1ft),  Curb or Sidewalk Widths: Left: 1.1m (3.6ft),  Right: 0.0m,  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.7m (38.4ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 62.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 5701,  Location: 0.6 MI S OF I-95 (Lat: 41.287508,  Lng: -72.492481),  Route carried "on" structure: State highway 145,  Year Built: 1988,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 9,100 (year 2015),  Truck Traffic: 2%,  Average Future Daily Traffic: 13,522 (year 2035),  Design Load: HS 20,  Features Intersected: MENUNKETESUCK RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.253,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 4.0m (13.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Channel: Satisfactory,  Culverts: Fair,  Operating Rating: 42.6 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 6084,  Location: 500 FT N OF US ROUTE 1 (Lat: 41.283936,  Lng: -72.456853),  Route carried "on" structure: City street ,  Year Built: 1991,  Status: Open,  Structure Length: 1.95m (6.40ft),  Average Daily Traffic: 300 (year 2020),  Truck Traffic: 2%,  Average Future Daily Traffic: 446 (year 2040),  Design Load: HS 20,  Features Intersected: PATCHOGUE RIVER,  Facility Carried by Structure: WESLEY AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.161,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.3m (60.0ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 10.3m (33.8ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Very good,  Operating Rating: 66.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 6658,  Location: 0.2 MI EAST OF ROUTE 153 (Lat: 41.290036,  Lng: -72.441758),  Route carried "on" structure: City street ,  Year Built: 1996,  Status: Open,  Structure Length: 1.98m (6.50ft),  Average Daily Traffic: 3,380 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 5,022 (year 2038),  Design Load: HS 20,  Features Intersected: WETLANDS,  Facility Carried by Structure: FLAT ROCK PLACE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.338,  Lanes on structure: 4,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.7m (58.1ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 17.9m (58.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 46.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Underwater Inspection Frequency: Every 48 months,  Inspection Date: July 2018,  Underwater Inspection Date: July 2018,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 6659,  Location: 0.4 MI E OF ROUTRE 153 (Lat: 41.289750,  Lng: -72.435786),  Route carried "on" structure: City street ,  Year Built: 1996,  Status: Open,  Structure Length: 9.51m (31.20ft),  Average Daily Traffic: 3,380 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 5,022 (year 2038),  Design Load: HS 20,  Features Intersected: WETLANDS,  Facility Carried by Structure: FLAT ROCK PLACE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.805,  Lanes on structure: 4,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 18.0m (59.1ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 0.0m,  Curb-To-Curb Width: 14.9m (48.9ft),  Out-to-Out Width: 18.0m (59.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 52.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 31.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2018,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 666,  Location: 0.5 M EAST RTE 154 (Lat: 41.289714,  Lng: -72.434211),  Route carried "on" structure: City street ,  Year Built: 1996,  Status: Open,  Structure Length: 5.52m (18.11ft),  Average Daily Traffic: 3,380 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 5,022 (year 2038),  Design Load: HS 20,  Features Intersected: WETLANDS,  Facility Carried by Structure: FLAT ROCK PLACE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.966,  Lanes on structure: 4,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.0m (59.1ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 0.0m,  Curb-To-Curb Width: 14.7m (48.2ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Good,  Channel: Very good,  Operating Rating: 51.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2018,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 6661,  Location: 0.6 MI E OF ROUTE 153 (Lat: 41.289314,  Lng: -72.432967),  Route carried "on" structure: City street ,  Year Built: 1996,  Status: Open,  Structure Length: 5.73m (18.80ft),  Average Daily Traffic: 3,376 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 5,016 (year 2038),  Design Load: HS 20,  Features Intersected: WETLANDS,  Facility Carried by Structure: FLAT ROCK PLACE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.966,  Lanes on structure: 4,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 14.9m (48.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.0m (59.1ft),  Curb or Sidewalk Widths: Left: 1.9m (6.2ft),  Right: 0.0m,  Curb-To-Curb Width: 14.8m (48.6ft),  Out-to-Out Width: 17.7m (58.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 48.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2018,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 6942,  Location: 1.8 MI S OF ROUTE 80 (Lat: 41.338167,  Lng: -72.483056),  Route carried "on" structure: City street ,  Year Built: 2016,  Status: Open,  Structure Length: 0.82m (2.69ft),  Average Daily Traffic: 210 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 312 (year 2040),  Design Load: HL 93,  Features Intersected: FALLS RIVER,  Facility Carried by Structure: WINTHROP ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.772,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.4m (27.6ft),  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 79.7 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 61.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7038,  Location: 40 FT N. OF POND MEADOW R (Lat: 41.331111,  Lng: -72.464167),  Route carried "on" structure: City street ,  Year Built: 2019,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 505 (year 2020),  Truck Traffic: 1%,  Average Future Daily Traffic: 750 (year 2040),  Design Load: HL 93,  Features Intersected: FALLS RIVER,  Facility Carried by Structure: LYNN ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.016,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.2m (30.2ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.1m (33.1ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 63.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 227,  Location: 0.3 MI N OF ROUTE 145 (Lat: 41.292444,  Lng: -72.493400),  Route carried "under" structure: Interstate 95,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 62,000 (year 2017),  Truck Traffic: 14%,  Features Intersected: INTERSTATE-95,  Facility Carried by Structure: CHAPMAN MILLPOND R
Minimum Vertical Clearance: 4.52m (14.83ft),  Kilometerpoint: 113.459,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.9m (75.1ft)

Find on map >>   Show street view

Structure Number: 228,  Location: 2.4 MI S OF ROUTE 153 (Lat: 41.293986,  Lng: -72.488567),  Route carried "under" structure: Interstate 95,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 56,000 (year 2017),  Truck Traffic: 14%,  Features Intersected: INTERSTATE-95,  Facility Carried by Structure: ROUTE 145
Minimum Vertical Clearance: 4.67m (15.32ft),  Kilometerpoint: 113.909,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 21.6m (70.9ft)

Find on map >>   Show street view

Structure Number: 23,  Location: 2.0 MI N OF ROUTE 145 (Lat: 41.292072,  Lng: -72.450692),  Route carried "under" structure: Interstate 95,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 50,800 (year 2020),  Truck Traffic: 14%,  Features Intersected: INTERSTATE-95,  Facility Carried by Structure: WILLARD AVENUE
Minimum Vertical Clearance: 4.47m (14.67ft),  Kilometerpoint: 117.144,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.4m (57.1ft)

Find on map >>   Show street view

Structure Number: 232,  Location: I-95 EXIT NO. 65 (Lat: 41.291733,  Lng: -72.443811),  Route carried "under" structure: Interstate 95,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 53,500 (year 2018),  Truck Traffic: 9%,  Features Intersected: INTERSTATE-95,  Facility Carried by Structure: ROUTE 153 (ESSEX R
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 117.707,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 26.2m (86.0ft)