Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Templeton, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 16Number of bridges
  • 207ft / 62.7mTotal length
  • $1,901,000Total costs
  • 311,480Total average daily traffic
  • 12,865Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Templeton
  • No street view available for this location

New bridges in Templeton, CA - historical statistics
  • New bridges - historical statistics
  • 21920-1929
  • 21930-1939
  • 11950-1959
  • 91960-1969
  • 21970-1979
Reconstructed bridges in Templeton, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 21960-1969
  • 01970-1979
  • 11980-1989
  • 01990-1999
  • 02000-2009
  • 32010-2019
Average Bridge Daily Traffic in Templeton, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 55.6%Good
  • 33.3%Satisfactory
  • 11.1%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 88.9%Good
  • 11.1%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 88.9%Good
  • 11.1%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 25.0%Very good
  • 50.0%Good
  • 12.5%Satisfactory
  • 12.5%Fair
Find on map >>   Show street view

Structure Number: 49 0002R,  Location: 05-SLO-101-49.64 (Lat: 35.530136,  Lng: -120.707739),  Route carried "on" structure: US 101,  Year Built: 1939,  Year Reconstructed: 1994,  Status: Open,  Structure Length: 5.18m (16.99ft),  Average Daily Traffic: 31,000 (year 2009),  Truck Traffic: 3%,  Average Future Daily Traffic: 38,685 (year 2043),  Design Load: H 15,  Features Intersected: PASO ROBLES CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 49.640,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 39.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 49 0105,  Location: 05-SLO-046-R15.85 (Lat: 35.548344,  Lng: -120.787575),  Route carried "on" structure: State highway 46,  Year Built: 1969,  Status: Open,  Structure Length: 4.88m (16.01ft),  Average Daily Traffic: 4,600 (year 2009),  Average Future Daily Traffic: 5,628 (year 2037),  Design Load: HS 20,  Features Intersected: JACK CREEK (PSO RBLS CR)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.850,  Lanes on structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 18.9m (62.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 31.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 20.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 49 0137,  Location: 05-SLO-101-53.17 (Lat: 35.575756,  Lng: -120.697353),  Route carried "on" structure: US 101,  Year Built: 1952,  Year Reconstructed: 1974,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 54,000 (year 2009),  Truck Traffic: 9%,  Average Future Daily Traffic: 71,674 (year 2039),  Features Intersected: WHITEHORSE DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 53.170,  Lanes on structure: 4,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 34.1m (111.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021
Find on map >>   Show street view

Structure Number: 49 0194L,  Location: 05-SLO-101-51.45 (Lat: 35.554253,  Lng: -120.712258),  Route carried "on" structure: US 101,  Year Built: 1967,  Status: Open,  Structure Length: 3.69m (12.11ft),  Average Daily Traffic: 31,000 (year 2009),  Truck Traffic: 3%,  Average Future Daily Traffic: 37,418 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: LAS TABLAS AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 51.450,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.6m (54.5ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 43.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 49 0194R,  Location: 05-SLO-101-51.45 (Lat: 35.554253,  Lng: -120.711942),  Route carried "on" structure: US 101,  Year Built: 1967,  Status: Open,  Structure Length: 3.69m (12.11ft),  Average Daily Traffic: 31,000 (year 2009),  Truck Traffic: 3%,  Average Future Daily Traffic: 37,418 (year 2039),  Design Load: HS 20+Mod,  Features Intersected: LAS TABLAS AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 51.450,  Lanes on structure: 2,  Lanes under structure: 3,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.6m (54.5ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 43.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 49 0195,  Location: 05-SLO-101-50.64 (Lat: 35.543600,  Lng: -120.714875),  Route carried "on" structure: County highway W113,  Year Built: 1967,  Year Reconstructed: 2010,  Status: Open,  Structure Length: 5.91m (19.39ft),  Average Daily Traffic: 6,600 (year 2005),  Truck Traffic: 5%,  Average Future Daily Traffic: 11,046 (year 2041),  Design Load: HS 20,  Features Intersected: US HIGHWAY 101,  Facility Carried by Structure: VINEYARD DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 3,  Lanes under structure: 5,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 14.1m (46.3ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 33.9m (111.2ft),  Curb or Sidewalk Widths: Left: 2.1m (6.9ft),  Right: 0.0m,  Curb-To-Curb Width: 14.1m (46.3ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 41.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 49 02,  Location: 05-SLO-101-52.44 (Lat: 35.565994,  Lng: -120.702267),  Route carried "on" structure: County highway W113,  Year Built: 1966,  Status: Open,  Structure Length: 5.90m (19.36ft),  Average Daily Traffic: 6,800 (year 2008),  Truck Traffic: 5%,  Average Future Daily Traffic: 9,116 (year 2041),  Design Load: HS 20+Mod,  Features Intersected: US HIGHWAY 101,  Facility Carried by Structure: MAIN STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Number Of Approach Spans: 2,  Length of Maximum Span: 19.1m (62.7ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.2m (30.2ft),  Out-to-Out Width: 11.4m (37.4ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 36.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 26.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 49C0177,  Location: 0.3 MI E OF U.S. 101 (Lat: 35.543142,  Lng: -120.706353),  Route carried "on" structure: County highway ,  Year Built: 1977,  Status: Open,  Structure Length: 20.51m (67.29ft),  Average Daily Traffic: 4,119 (year 2010),  Truck Traffic: 3%,  Average Future Daily Traffic: 4,211 (year 2040),  Design Load: HS 20,  Features Intersected: SALINAS RIVER,  Facility Carried by Structure: VINEYARD DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 5,  Number Of Approach Spans: 2,  Length of Maximum Span: 38.1m (125.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 99.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 65.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 49C0342,  Location: 0.2 MI N STATE RTE 46 (Lat: 35.548272,  Lng: -120.793064),  Route carried "on" structure: County highway ,  Year Built: 1938,  Year Reconstructed: 1969,  Status: Posted for load-capacity,  Structure Length: 6.22m (20.41ft),  Average Daily Traffic: 151 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 151 (year 2040),  Design Load: H 15,  Features Intersected: PASO ROBLES CREEK,  Facility Carried by Structure: JACK CREEK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 7.4m (24.3ft),  Material/Design: Wood or Timber,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 11,  Length of Maximum Span: 5.8m (19.0ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 4.0m (13.1ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Poor,  Channel: Good,  Operating Rating: 20.4 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 13.3 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.22m (20.41ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Bridge Improvement Cost: $1,131,000,  Roadway Improvement Cost: $226,000,  Total Project Cost: $1,901,000 ( Estimate for 2019),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 49C0348,  Location: 0.9 MI SWVINEYARD DR (Lat: 35.536883,  Lng: -120.727553),  Route carried "on" structure: County highway ,  Year Built: 1971,  Status: Open,  Structure Length: 4.54m (14.90ft),  Average Daily Traffic: 538 (year 2010),  Truck Traffic: 1%,  Average Future Daily Traffic: 596 (year 2040),  Design Load: H 15,  Features Intersected: PASO ROBLES CREEK,  Facility Carried by Structure: SNTA RITA OLD CK R
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.5m (54.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Channel: Fair,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 48.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 49C0402,  Location: 0.35 MI SOUTH RAMADA DR (Lat: 35.561233,  Lng: -120.700594),  Route carried "on" structure: County highway ,  Year Built: 1929,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 0.81m (2.66ft),  Average Daily Traffic: 6,836 (year 2009),  Truck Traffic: 3%,  Average Future Daily Traffic: 9,243 (year 2040),  Features Intersected: TEMPLETON CREEK,  Facility Carried by Structure: MAIN ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 13.9m (45.6ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 27.2 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 49C0403,  Location: 0.3 MI SOUTH RAMADA DR (Lat: 35.562014,  Lng: -120.700475),  Route carried "on" structure: County highway ,  Year Built: 1929,  Year Reconstructed: 2016,  Status: Open,  Structure Length: 0.68m (2.23ft),  Average Daily Traffic: 6,836 (year 2009),  Truck Traffic: 3%,  Average Future Daily Traffic: 9,243 (year 2039),  Features Intersected: NORTH FORK TEMPLETON CRK,  Facility Carried by Structure: MAIN ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.4m (11.2ft)

Condition: Channel: Good,  Culverts: Good,  Operating Rating: 27.2 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 49 0194L,  Location: 05-SLO-101-51.45 (Lat: 35.554253,  Lng: -120.712258),  Route carried "under" structure: Business City street ,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 2,000 (year 2005),  Truck Traffic: 7%,  Features Intersected: LAS TABLAS AVE,  Facility Carried by Structure: US HIGHWAY 101 SB
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 16.6m (54.5ft)

Find on map >>   Show street view

Structure Number: 49 0194R,  Location: 05-SLO-101-51.45 (Lat: 35.554253,  Lng: -120.711942),  Route carried "under" structure: Business City street ,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 2,000 (year 2005),  Truck Traffic: 7%,  Features Intersected: LAS TABLAS AVE,  Facility Carried by Structure: US HIGHWAY 101 NB
Minimum Vertical Clearance: 4.97m (16.31ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 3,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 16.6m (54.5ft)

Find on map >>   Show street view

Structure Number: 49 0195,  Location: 05-SLO-101-50.64 (Lat: 35.543600,  Lng: -120.714875),  Route carried "under" structure: US 101,  Year Built: 1967,  Structure Length: 0. m,  Average Daily Traffic: 62,000 (year 2009),  Truck Traffic: 3%,  Features Intersected: US HIGHWAY 101,  Facility Carried by Structure: VINEYARD DR
Minimum Vertical Clearance: 4.74m (15.55ft),  Kilometerpoint: 50.640,  Lanes on structure: 3,  Lanes under structure: 5,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 33.9m (111.2ft)

Find on map >>   Show street view

Structure Number: 49 02,  Location: 05-SLO-101-52.44 (Lat: 35.565994,  Lng: -120.702267),  Route carried "under" structure: US 101,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 62,000 (year 2009),  Truck Traffic: 3%,  Features Intersected: US HIGHWAY 101,  Facility Carried by Structure: MAIN STREET
Minimum Vertical Clearance: 4.92m (16.14ft),  Kilometerpoint: 52.440,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 19.1m (62.7ft)

Discuss Templeton, California (CA) on our hugely popular California forum.