Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Soledad, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 16Number of bridges
  • 512ft / 156mTotal length
  • $1,562,000Total costs
  • 246,010Total average daily traffic
  • 24,781Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Soledad
  • No street view available for this location

New bridges in Soledad, CA - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 11940-1949
  • 61950-1959
  • 51960-1969
  • 21990-1999
  • 12000-2009
Reconstructed bridges in Soledad, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11990-1999
  • 12000-2009
Average Bridge Daily Traffic in Soledad, CA
Average Bridge Truck Traffic in Soledad, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 66.7%Good
  • 11.1%Satisfactory
  • 11.1%Fair
  • 11.1%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 88.9%Good
  • 11.1%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 75.0%Excellent
  • 25.0%Very good
Find on map >>   Show street view

Structure Number: 44 0002L,  Location: 05-MON-101-60.75 (Lat: 36.407981,  Lng: -121.318856),  Route carried "on" structure: US 101,  Year Built: 1999,  Status: Open,  Structure Length: 47.08m (154.46ft),  Average Daily Traffic: 18,600 (year 2009),  Average Future Daily Traffic: 27,850 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: SALINAS RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.750,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 11,  Length of Maximum Span: 43.4m (142.4ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 44 0002R,  Location: 05-MON-101-60.75 (Lat: 36.408036,  Lng: -121.318608),  Route carried "on" structure: US 101,  Year Built: 1999,  Status: Open,  Structure Length: 47.08m (154.46ft),  Average Daily Traffic: 18,600 (year 2009),  Average Future Daily Traffic: 27,850 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: SALINAS RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 60.750,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.9m (39.0ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 11,  Length of Maximum Span: 43.4m (142.4ft),  Curb-To-Curb Width: 11.9m (39.0ft),  Out-to-Out Width: 13.0m (42.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 44 0091L,  Location: 05-MON-101-62.70 (Lat: 36.431156,  Lng: -121.337211),  Route carried "on" structure: US 101,  Year Built: 1960,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 9.55m (31.33ft),  Average Daily Traffic: 18,660 (year 2009),  Truck Traffic: 16%,  Average Future Daily Traffic: 23,260 (year 2042),  Design Load: HS 20,  Features Intersected: UP RR, AMTRAK, FRONT ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 62.700,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.0m (91.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 75.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: May 2020,  Other Special Inspection Date: July 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete
Find on map >>   Show street view

Structure Number: 44 0091R,  Location: 05-MON-101-62.70 (Lat: 36.430981,  Lng: -121.336911),  Route carried "on" structure: US 101,  Year Built: 1960,  Status: Open,  Structure Length: 9.55m (31.33ft),  Average Daily Traffic: 18,200 (year 2009),  Truck Traffic: 16%,  Average Future Daily Traffic: 22,852 (year 2042),  Design Load: HS 20,  Features Intersected: UP RR, AMTRAK, FRONT ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 62.700,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 1,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 5 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 28.0m (91.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Good,  Operating Rating: 76.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 46.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: High priority of corrective action,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 9.55m (31.33ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: May 2020,  Other Special Inspection Date: July 2018,  Bridge Improvement Cost: $984,000,  Roadway Improvement Cost: $186,000,  Total Project Cost: $1,562,000 ( Estimate for 2017),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 44 0115,  Location: 05-MON-101-60.40 (Lat: 36.403175,  Lng: -121.316925),  Route carried "on" structure: County highway ,  Year Built: 1958,  Status: Open,  Structure Length: 6.57m (21.56ft),  Average Daily Traffic: 2,750 (year 2006),  Truck Traffic: 5%,  Average Future Daily Traffic: 3,451 (year 2042),  Design Load: HS 20,  Features Intersected: US HIGHWAY 101,  Facility Carried by Structure: ARROYO SECO RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.7m (67.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 68.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 41.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 44 0116,  Location: 05-MON-101-66.40 (Lat: 36.464728,  Lng: -121.387856),  Route carried "on" structure: County highway ,  Year Built: 1959,  Status: Open,  Structure Length: 5.59m (18.34ft),  Average Daily Traffic: 1,060 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,630 (year 2038),  Design Load: HS 20,  Features Intersected: US HIGHWAY 101,  Facility Carried by Structure: SOLEDAD PRISON RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.6m (61.0ft),  Curb or Sidewalk Widths: Left: 1.6m (5.2ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 40.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 31.1 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 44 0117,  Location: 05-MON-101-64.63 (Lat: 36.448775,  Lng: -121.363106),  Route carried "on" structure: County highway ,  Year Built: 1959,  Status: Open,  Structure Length: 5.58m (18.31ft),  Average Daily Traffic: 1,060 (year 2009),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,630 (year 2038),  Design Load: HS 20,  Features Intersected: US HIGHWAY 101,  Facility Carried by Structure: SILLIMAN RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.6m (61.0ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 41.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 44C0126,  Location: 0.6 MI.S ARROYO SECO ROAD (Lat: 36.371756,  Lng: -121.318733),  Route carried "on" structure: County highway ,  Year Built: 1940,  Year Reconstructed: 2003,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 580 (year 2016),  Truck Traffic: 1%,  Average Future Daily Traffic: 800 (year 2037),  Features Intersected: SPRECKELS CANAL,  Facility Carried by Structure: LOS COCHES ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.0m (19.7ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.1m (26.6ft),  Curb-To-Curb Width: 6.5m (21.3ft),  Out-to-Out Width: 6.7m (22.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Excellent,  Operating Rating: 45.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 26.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 44C018,  Location: 0.5 MI SW OF SR 101 (Lat: 36.398344,  Lng: -121.326264),  Route carried "on" structure: County highway ,  Year Built: 2007,  Status: Open,  Structure Length: 24.40m (80.05ft),  Average Daily Traffic: 3,900 (year 2017),  Truck Traffic: 3%,  Average Future Daily Traffic: 8,000 (year 2037),  Features Intersected: ARROYO SECO RIVER,  Facility Carried by Structure: ARROYO SECO ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.0m (39.4ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 44.5m (146.0ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 44 0090E,  Location: 05-MON-146-1.49 (Lat: 36.419039,  Lng: -121.323772),  Route carried "under" structure: US 101,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 32,000 (year 2011),  Truck Traffic: 2%,  Features Intersected: US HWY 101
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 61.580,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 23.5m (77.1ft)

Find on map >>   Show street view

Structure Number: 44 0091L,  Location: 05-MON-101-62.70 (Lat: 36.431156,  Lng: -121.337211),  Route carried "under" structure: County highway W003,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 5,150 (year 2009),  Truck Traffic: 7%,  Features Intersected: UP RR, AMTRAK, FRONT ST,  Facility Carried by Structure: US HIGHWAY 101 SB
Minimum Vertical Clearance: 6.88m (22.57ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.0m (91.9ft)

Find on map >>   Show street view

Structure Number: 44 0091R,  Location: 05-MON-101-62.70 (Lat: 36.430981,  Lng: -121.336911),  Route carried "under" structure: County highway W003,  Year Built: 1960,  Structure Length: 0. m,  Average Daily Traffic: 6,950 (year 2009),  Truck Traffic: 3%,  Features Intersected: UP RR, AMTRAK, FRONT ST,  Facility Carried by Structure: US HIGHWAY 101 NB
Minimum Vertical Clearance: 7.34m (24.08ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 28.0m (91.9ft)

Find on map >>   Show street view

Structure Number: 44 0115,  Location: 05-MON-101-60.40 (Lat: 36.403175,  Lng: -121.316925),  Route carried "under" structure: US 101,  Year Built: 1958,  Structure Length: 0. m,  Average Daily Traffic: 35,000 (year 2010),  Truck Traffic: 16%,  Features Intersected: US HIGHWAY 101,  Facility Carried by Structure: ARROYO SECO RD
Minimum Vertical Clearance: 5.02m (16.47ft),  Kilometerpoint: 60.400,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 20.7m (67.9ft)

Find on map >>   Show street view

Structure Number: 44 0116,  Location: 05-MON-101-66.40 (Lat: 36.464728,  Lng: -121.387856),  Route carried "under" structure: US 101,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 38,700 (year 2009),  Truck Traffic: 18%,  Features Intersected: US HIGHWAY 101,  Facility Carried by Structure: SOLEDAD PRISON RD
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 66.400,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 18.6m (61.0ft)

Find on map >>   Show street view

Structure Number: 44 0117,  Location: 05-MON-101-64.63 (Lat: 36.448775,  Lng: -121.363106),  Route carried "under" structure: US 101,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 39,500 (year 2010),  Truck Traffic: 10%,  Features Intersected: US HIGHWAY 101,  Facility Carried by Structure: SILLIMAN RD
Minimum Vertical Clearance: 4.64m (15.22ft),  Kilometerpoint: 64.630,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Length of Maximum Span: 18.6m (61.0ft)

Find on map >>   Show street view

Structure Number: 44C0187,  Location: 0.2 MI SW OF EAST ST (Lat: 36.422442,  Lng: -121.323294),  Route carried "under" structure: City street ,  Year Built: 1936,  Structure Length: 0. m,  Average Daily Traffic: 5,300 (year 2006),  Truck Traffic: 15%,  Features Intersected: FRONT ST,  Facility Carried by Structure: UP RR & AMTRAK
Minimum Vertical Clearance: 4.44m (14.57ft),  Kilometerpoint: 0.000,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Girder and Floorbeam System,  Length of Maximum Span: 30.2m (99.1ft)

Discuss Soledad, California (CA) on our hugely popular California forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.