Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Post Falls, Idaho (ID)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 31Number of bridges
  • 407ft / 124mTotal length
  • $1,533,000Total costs
  • 691,895Total average daily traffic
  • 47,599Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Post Falls
  • No street view available for this location

New bridges in Post Falls, ID - historical statistics
  • New bridges - historical statistics
  • 221970-1979
  • 12000-2009
  • 72010-2019
  • 12020-2022
Average Bridge Daily Traffic in Post Falls, ID
Average Bridge Truck Traffic in Post Falls, ID
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 5.6%Excellent
  • 5.6%Very good
  • 50.0%Good
  • 38.9%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 5.6%Excellent
  • 27.8%Very good
  • 27.8%Good
  • 38.9%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 5.6%Excellent
  • 11.1%Very good
  • 11.1%Good
  • 72.2%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.3%Very good
  • 66.7%Good
Find on map >>   Show street view

Structure Number: 14246,  Location: 1.5 N. POST FALLS (Lat: 47.766083,  Lng: -116.894139),  Route carried "on" structure: State highway 41,  Year Built: 2021,  Status: Open,  Structure Length: 4.30m (14.11ft),  Average Daily Traffic: 6,750 (year 2021),  Truck Traffic: 6%,  Average Future Daily Traffic: 10,125 (year 2041),  Design Load: HL 93,  Features Intersected: UPRR MAINLINE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.282,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 41.8m (137.1ft),  Curb or Sidewalk Widths: Left: 0.0m,  Right: 3.7m (12.1ft),  Curb-To-Curb Width: 12.0m (39.4ft),  Out-to-Out Width: 16.7m (54.8ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Excellent,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: No rating analysis performed,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: No rating analysis performed,  Structural Evaluation: Superior to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 16735,  Location: AT IDAHO WASH.STATE LINE (Lat: 47.697111,  Lng: -117.040139),  Route carried "on" structure: Interstate 90,  Year Built: 1976,  Status: Open,  Structure Length: 14.17m (46.49ft),  Average Daily Traffic: 30,500 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 45,750 (year 2039),  Design Load: HS 20,  Features Intersected: SPOKANE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: I,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Navigation Control: Yes ( Vertical Clearance: 8.0m (26.2ft), Horizontal Clearance: 22.0m (72.2ft)),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 28.0m (91.9ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 60.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: March 2021,  Underwater Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 1674,  Location: AT IDAHO WASH.STATE LINE (Lat: 47.696611,  Lng: -117.041583),  Route carried "on" structure: Interstate 90,  Year Built: 1976,  Status: Open,  Structure Length: 14.17m (46.49ft),  Average Daily Traffic: 30,500 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 45,750 (year 2039),  Design Load: HS 20,  Features Intersected: SPOKANE RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.002,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: I,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 3 degrees,  Navigation Control: Yes ( Vertical Clearance: 8.0m (26.2ft), Horizontal Clearance: 22.0m (72.2ft)),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 28.0m (91.9ft),  Curb-To-Curb Width: 14.7m (48.2ft),  Out-to-Out Width: 17.0m (55.8ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 57.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: March 2021,  Underwater Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 16742,  Location: 0.96 E. IDA-WA LINE (Lat: 47.701167,  Lng: -117.019361),  Route carried "on" structure: County highway 7227,  Year Built: 2012,  Status: Open,  Structure Length: 7.28m (23.88ft),  Average Daily Traffic: 6,000 (year 2019),  Average Future Daily Traffic: 9,000 (year 2039),  Design Load: HL 93,  Features Intersected: I 90; POINTE PARKWAY IC
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 162.159,  Lanes on structure: 6,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 23.2m (76.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 36.0m (118.1ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 27.1m (88.9ft),  Out-to-Out Width: 31.6m (103.7ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 51.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 39.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2018,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 16745,  Location: 2.1 E. IDA-WA LINE (Lat: 47.709056,  Lng: -117.002056),  Route carried "on" structure: Interstate 90,  Year Built: 1976,  Status: Open,  Structure Length: 4.91m (16.11ft),  Average Daily Traffic: 28,750 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 43,125 (year 2039),  Design Load: HS 20,  Features Intersected: S 8505;PLEASANT VIEW IC
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.326,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: I,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.3m (73.2ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1675,  Location: 2.1 E. IDA-WA LINE (Lat: 47.709500,  Lng: -117.001450),  Route carried "on" structure: Interstate 90,  Year Built: 1976,  Status: Open,  Structure Length: 4.91m (16.11ft),  Average Daily Traffic: 28,750 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 43,125 (year 2039),  Design Load: HS 20,  Features Intersected: S 8505;PLEASANT VIEW IC
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.328,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: I,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.3m (73.2ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1676,  Location: IN POST FALLS (Lat: 47.712778,  Lng: -116.951944),  Route carried "on" structure: Interstate 90,  Year Built: 1977,  Status: Open,  Structure Length: 6.40m (21.00ft),  Average Daily Traffic: 57,500 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 86,250 (year 2039),  Design Load: HS 20,  Features Intersected: BNRR;POST FALLS OP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.178,  Lanes on structure: 5,  Base Highway Network: Yes (Inventory Route: I,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 44.2m (145.0ft),  Skew: 33 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 24.1m (79.1ft),  Curb-To-Curb Width: 51.1m (167.7ft),  Out-to-Out Width: 52.0m (170.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 68.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 40.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: March 2021,  Other Special Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 16765,  Location: IN POST FALLS;SPOKANE ST. (Lat: 47.712553,  Lng: -116.948431),  Route carried "on" structure: Interstate 90,  Year Built: 1977,  Status: Open,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 28,750 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 43,125 (year 2039),  Design Load: HS 20,  Features Intersected: I 90B;POST FALLS IC
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.434,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: I,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 36.6m (120.1ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 36.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 28.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 1677,  Location: IN POST FALLS;SPOKANE ST. (Lat: 47.712756,  Lng: -116.947708),  Route carried "on" structure: Interstate 90,  Year Built: 1977,  Status: Open,  Structure Length: 5.21m (17.09ft),  Average Daily Traffic: 28,750 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 43,125 (year 2039),  Design Load: HS 20,  Features Intersected: I 90B;POST FALLS IC
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.435,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: I,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.6m (38.1ft),  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 2,  Length of Maximum Span: 36.6m (120.1ft),  Curb-To-Curb Width: 12.4m (40.7ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 36.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 28.2 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 16773,  Location: 1.0 W of I-90/SH-41 IC (Lat: 47.712000,  Lng: -116.915944),  Route carried "on" structure: City street 7525,  Year Built: 2015,  Status: Open,  Structure Length: 10.18m (33.40ft),  Average Daily Traffic: 10,500 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 15,750 (year 2039),  Design Load: HL 93,  Features Intersected: I 90 EB-WB;SCHNEIDMILLER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 160.810,  Lanes on structure: 4,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 21.3m (69.9ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 35.1m (115.2ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 18.3m (60.0ft),  Out-to-Out Width: 22.7m (74.5ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 48.0 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 16785,  Location: 1.7 E. POST FALLS (Lat: 47.710417,  Lng: -116.895444),  Route carried "on" structure: Interstate 90,  Year Built: 1971,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 30,000 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 45,000 (year 2039),  Design Load: HS 20,  Features Intersected: SH 41;SH 41 IC
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.452,  Lanes on structure: 2,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: I,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1679,  Location: 1.7 E. POST FALLS (Lat: 47.710500,  Lng: -116.894889),  Route carried "on" structure: Interstate 90,  Year Built: 1971,  Status: Open,  Structure Length: 3.96m (12.99ft),  Average Daily Traffic: 30,000 (year 2019),  Truck Traffic: 7%,  Average Future Daily Traffic: 45,000 (year 2039),  Design Load: HS 20,  Features Intersected: SH 41;SH 41 IC
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 11.454,  Lanes on structure: 3,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: I,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 11.6m (38.1ft),  Out-to-Out Width: 14.1m (46.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 59.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Underclear: High priority of replacement,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.97m (16.31ft),  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2019,  Bridge Improvement Cost: $1,022,000,  Roadway Improvement Cost: $102,000,  Total Project Cost: $1,533,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 174,  Location: IN POST FALLS (Lat: 47.712361,  Lng: -116.951444),  Route carried "on" structure: Ramp Interstate 90,  Year Built: 1977,  Status: Open,  Structure Length: 5.30m (17.39ft),  Average Daily Traffic: 6,600 (year 2019),  Average Future Daily Traffic: 9,900 (year 2039),  Design Load: HS 20,  Features Intersected: BNRR;POST FALLS RAMP OP
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.303,  Lanes on structure: 1,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 7.5m (24.6ft),  Out-to-Out Width: 8.4m (27.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 63.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Other Special Inspection Frequency: Every 48 months,  Inspection Date: March 2021,  Other Special Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 30535,  Location: 1.5 W. POST FALLS (Lat: 47.710861,  Lng: -116.980278),  Route carried "on" structure: County highway ,  Year Built: 1976,  Status: Open,  Structure Length: 9.88m (32.41ft),  Average Daily Traffic: 2,400 (year 2019),  Truck Traffic: 13%,  Average Future Daily Traffic: 3,600 (year 2039),  Design Load: HS 20,  Features Intersected: I 90 EB-WB;MCGUIRE RD.GS,  Facility Carried by Structure: MCGUIRE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.730,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 31.7m (104.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 10.5m (34.4ft),  Out-to-Out Width: 12.9m (42.3ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 45.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor (LRFR),  Inventory Rating: 35.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor (LRFR),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Cathodic Protection
Find on map >>   Show street view

Structure Number: 30543,  Location: 1.4 S. 2.6 E. POST FALLS (Lat: 47.694417,  Lng: -116.872750),  Route carried "on" structure: County highway ,  Year Built: 2000,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 500 (year 2019),  Truck Traffic: 5%,  Average Future Daily Traffic: 750 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: CHANNEL OF SPOKANE RIVER,  Facility Carried by Structure: W HARBOR DRIVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 161.177,  Lanes on structure: 2,  Owner: Local Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Navigation Control: Yes ( Vertical Clearance: 2.1m (6.9ft), Horizontal Clearance: 7.9m (25.9ft)),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 3057,  Location: IN POST FALLS (Lat: 47.712250,  Lng: -116.937278),  Route carried "on" structure: City street ,  Year Built: 1977,  Status: Open,  Structure Length: 8.96m (29.40ft),  Average Daily Traffic: 3,500 (year 2019),  Average Future Daily Traffic: 5,250 (year 2039),  Design Load: HS 20,  Features Intersected: I 90 EB-WB;IDAHO RD GS,  Facility Carried by Structure: IDAHO ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.129,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 33.5m (109.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 13.4m (44.0ft),  Out-to-Out Width: 17.4m (57.1ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 40.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Cathodic Protection
Find on map >>   Show street view

Structure Number: 30575,  Location: AT POST FALLS WCL (Lat: 47.713000,  Lng: -116.931194),  Route carried "on" structure: City street 7605,  Year Built: 1977,  Status: Open,  Structure Length: 12.04m (39.50ft),  Average Daily Traffic: 14,500 (year 2019),  Truck Traffic: 2%,  Average Future Daily Traffic: 21,750 (year 2039),  Design Load: HS 20,  Features Intersected: I 90 EB-WB;SELTICE IC
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.933,  Lanes on structure: 4,  Lanes under structure: 4,  Base Highway Network: Yes (Inventory Route: 76,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 38.1m (125.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 19.8m (65.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Operating Rating: 61.2 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 47.3 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 3377,  Location: AT POST FALLS WCL (Lat: 47.700500,  Lng: -117.018694),  Route carried "on" structure: City street 7227,  Year Built: 2013,  Status: Open,  Structure Length: 2.50m (8.20ft),  Average Daily Traffic: 3,000 (year 2019),  Average Future Daily Traffic: 4,500 (year 2039),  Design Load: HL 93,  Features Intersected: RIVERBEND AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 162.288,  Lanes on structure: 4,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 27.1m (88.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 25.0m (82.0ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 27.1m (88.9ft),  Out-to-Out Width: 31.6m (103.7ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Operating Rating: 48.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 32.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2019,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 16742,  Location: 0.96 E. IDA-WA LINE (Lat: 47.701167,  Lng: -117.019361),  Route carried "under" structure: Interstate 90,  Year Built: 2012,  Structure Length: 0. m,  Average Daily Traffic: 60,000 (year 2018),  Truck Traffic: 7%,  Features Intersected: I 90; POINTE PARKWAY IC,  Facility Carried by Structure: SMA7227;POINTEPKWY
Minimum Vertical Clearance: 5.54m (18.18ft),  Kilometerpoint: 1.545,  Lanes on structure: 6,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 36.0m (118.1ft)

Find on map >>   Show street view

Structure Number: 16745,  Location: 2.1 E. IDA-WA LINE (Lat: 47.709056,  Lng: -117.002056),  Route carried "under" structure: County highway 8505,  Year Built: 1976,  Structure Length: 0. m,  Average Daily Traffic: 10,500 (year 2018),  Truck Traffic: 10%,  Features Intersected: S 8505;PLEASANT VIEW IC,  Facility Carried by Structure: I 90 EBL
Minimum Vertical Clearance: 5.18m (16.99ft),  Kilometerpoint: 5.317,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.3m (73.2ft)

Find on map >>   Show street view

Structure Number: 1675,  Location: 2.1 E. IDA-WA LINE (Lat: 47.709500,  Lng: -117.001450),  Route carried "under" structure: County highway 8505,  Year Built: 1976,  Structure Length: 0. m,  Average Daily Traffic: 10,500 (year 2018),  Truck Traffic: 10%,  Features Intersected: S 8505;PLEASANT VIEW IC,  Facility Carried by Structure: I 90 WBL
Minimum Vertical Clearance: 5.49m (18.01ft),  Kilometerpoint: 5.349,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.3m (73.2ft)

Find on map >>   Show street view

Structure Number: 16765,  Location: IN POST FALLS;SPOKANE ST. (Lat: 47.712553,  Lng: -116.948431),  Route carried "under" structure: Business Interstate 90,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 17,000 (year 2018),  Truck Traffic: 2%,  Features Intersected: I 90B;POST FALLS IC
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 0.288,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 36.6m (120.1ft)

Find on map >>   Show street view

Structure Number: 1677,  Location: IN POST FALLS;SPOKANE ST. (Lat: 47.712756,  Lng: -116.947708),  Route carried "under" structure: Business Interstate 90,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 17,000 (year 2018),  Truck Traffic: 2%,  Features Intersected: I 90B;POST FALLS IC
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 0.267,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 36.6m (120.1ft)

Find on map >>   Show street view

Structure Number: 16773,  Location: 1.0 W of I-90/SH-41 IC (Lat: 47.712000,  Lng: -116.915944),  Route carried "under" structure: Interstate 90,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 60,500 (year 2018),  Truck Traffic: 7%,  Features Intersected: I 90 EB-WB;SCHNEIDMILLER,  Facility Carried by Structure: S7525;GREENSFERRY
Minimum Vertical Clearance: 5.51m (18.08ft),  Kilometerpoint: 9.815,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Find on map >>   Show street view

Structure Number: 16773,  Location: 1.0 W of I-90/SH-41 IC (Lat: 47.712000,  Lng: -116.915944),  Route carried "under" structure: City street ,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 50 (year 2018),  Features Intersected: I 90 EB-WB;SCHNEIDMILLER,  Facility Carried by Structure: S7525;GREENSFERRY
Minimum Vertical Clearance: 5.52m (18.11ft),  Kilometerpoint: 161.557,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 35.1m (115.2ft)

Find on map >>   Show street view

Structure Number: 16785,  Location: 1.7 E. POST FALLS (Lat: 47.710417,  Lng: -116.895444),  Route carried "under" structure: State highway 41,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 21,500 (year 2018),  Truck Traffic: 4%,  Features Intersected: SH 41;SH 41 IC,  Facility Carried by Structure: I 90 EBL
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 0.105,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.6m (47.9ft)

Find on map >>   Show street view

Structure Number: 1679,  Location: 1.7 E. POST FALLS (Lat: 47.710500,  Lng: -116.894889),  Route carried "under" structure: State highway 41,  Year Built: 1971,  Structure Length: 0. m,  Average Daily Traffic: 21,500 (year 2018),  Truck Traffic: 4%,  Features Intersected: SH 41;SH 41 IC,  Facility Carried by Structure: I 90 WBL
Minimum Vertical Clearance: 4.85m (15.91ft),  Kilometerpoint: 0.121,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 14.6m (47.9ft)

Find on map >>   Show street view

Structure Number: 30535,  Location: 1.5 W. POST FALLS (Lat: 47.710861,  Lng: -116.980278),  Route carried "under" structure: Interstate 90,  Year Built: 1976,  Structure Length: 0. m,  Average Daily Traffic: 57,500 (year 2018),  Truck Traffic: 7%,  Features Intersected: I 90 EB-WB;MCGUIRE RD.GS,  Facility Carried by Structure: MCGUIRE RD
Minimum Vertical Clearance: 5.13m (16.83ft),  Kilometerpoint: 4.981,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 31.7m (104.0ft)

Find on map >>   Show street view

Structure Number: 3057,  Location: IN POST FALLS (Lat: 47.712250,  Lng: -116.937278),  Route carried "under" structure: Interstate 90,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 54,000 (year 2018),  Truck Traffic: 8%,  Features Intersected: I 90 EB-WB;IDAHO RD GS,  Facility Carried by Structure: IDAHO ROAD
Minimum Vertical Clearance: 4.93m (16.17ft),  Kilometerpoint: 8.277,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 33.5m (109.9ft)

Find on map >>   Show street view

Structure Number: 30575,  Location: AT POST FALLS WCL (Lat: 47.713000,  Lng: -116.931194),  Route carried "under" structure: Interstate 90,  Year Built: 1977,  Structure Length: 0. m,  Average Daily Traffic: 14,500 (year 2018),  Truck Traffic: 27%,  Features Intersected: I 90 EB-WB;SELTICE IC,  Facility Carried by Structure: STP7605;SELTICE WY
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 8.771,  Lanes on structure: 4,  Lanes under structure: 4,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 38.1m (125.0ft)

Find on map >>   Show street view

Structure Number: 3377,  Location: AT POST FALLS WCL (Lat: 47.700500,  Lng: -117.018694),  Route carried "under" structure: City street ,  Year Built: 2013,  Structure Length: 0. m,  Average Daily Traffic: 95 (year 2018),  Truck Traffic: 10%,  Features Intersected: RIVERBEND AVE,  Facility Carried by Structure: S7227;POINTE PKWY
Minimum Vertical Clearance: 5.67m (18.60ft),  Kilometerpoint: 16.441,  Lanes on structure: 4,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 25.0m (82.0ft)

Discuss Post Falls, Idaho (ID) on our hugely popular Idaho forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.