Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Pekin, Illinois (IL)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 14Number of bridges
  • 108ft / 32.9mTotal length
  • $1,126,000Total costs
  • 35,075Total average daily traffic
  • 3,184Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Pekin
  • No street view available for this location

New bridges in Pekin, IL - historical statistics
  • New bridges - historical statistics
  • 21900-1909
  • 11910-1919
  • 11920-1929
  • 11940-1949
  • 11950-1959
  • 11960-1969
  • 31970-1979
  • 21980-1989
  • 21990-1999
Average Bridge Daily Traffic in Pekin, IL
Average Bridge Truck Traffic in Pekin, IL
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 10.0%Excellent
  • 30.0%Good
  • 40.0%Satisfactory
  • 10.0%Fair
  • 10.0%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 9.1%Excellent
  • 18.2%Very good
  • 27.3%Satisfactory
  • 18.2%Fair
  • 27.3%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 36.4%Very good
  • 27.3%Good
  • 36.4%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 30.0%Good
  • 60.0%Satisfactory
  • 10.0%Poor
Find on map >>   Show street view

Structure Number: 900112,  Location: 1.5 MI S OF PEKIN (Lat: 40.529411,  Lng: -89.664458),  Route carried "on" structure: State highway 29,  Year Built: 1976,  Status: Open,  Structure Length: 2.62m (8.60ft),  Average Daily Traffic: 5,850 (year 2021),  Truck Traffic: 8%,  Average Future Daily Traffic: 5,106 (year 2032),  Design Load: HS 20,  Features Intersected: LOST CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 165.339,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 9.8m (32.2ft),  Curb-To-Curb Width: 9.3m (30.5ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 53.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 31.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 3.41m (11.19ft),  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: Febuary 2020,  Other Special Inspection Date: August 2021,  Bridge Improvement Cost: $369,000,  Roadway Improvement Cost: $37,000,  Total Project Cost: $554,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 900113,  Location: 1MI SW PEKIN (Lat: 40.538108,  Lng: -89.678639),  Route carried "on" structure: County highway ,  Year Built: 1977,  Status: Open,  Structure Length: 9.91m (32.51ft),  Average Daily Traffic: 4,800 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 6,128 (year 2032),  Design Load: HS 20,  Features Intersected: C&IM POWERTON SPUR,  Facility Carried by Structure: FAS 461-CH 16
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.933,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 42.1m (138.1ft),  Curb-To-Curb Width: 8.7m (28.5ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Very good,  Operating Rating: 65.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 39.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 903,  Location: SW-8-T24NR6W (Lat: 40.537911,  Lng: -89.699606),  Route carried "on" structure: County highway ,  Year Built: 1940,  Year Reconstructed: 1987,  Status: Open,  Structure Length: 5.11m (16.77ft),  Average Daily Traffic: 4,050 (year 2018),  Truck Traffic: 9%,  Average Future Daily Traffic: 5,268 (year 2032),  Design Load: HS 15,  Features Intersected: Mackinaw River Over,  Facility Carried by Structure: FAS-461 (CH-16)
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.736,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 19.6m (64.3ft),  Curb-To-Curb Width: 9.6m (31.5ft),  Out-to-Out Width: 9.6m (31.5ft)

Condition: Deck: Good,  Superstructure: Poor,  Substructure: Good,  Channel: Good,  Operating Rating: 41.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 24.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 4.21m (13.81ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Bridge Improvement Cost: $381,000,  Roadway Improvement Cost: $38,000,  Total Project Cost: $572,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 903073,  Location: SE-23-T24NR5W (Lat: 40.514411,  Lng: -89.632608),  Route carried "on" structure: County highway ,  Year Built: 1900,  Year Reconstructed: 1991,  Status: Open,  Structure Length: 0.98m (3.22ft),  Average Daily Traffic: 1,000 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 1,559 (year 2032),  Features Intersected: STREAM,  Facility Carried by Structure: TYRRELL RD - TR 76
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.867,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.4m (30.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Poor,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 90309,  Location: SE-31-T25NR4W (Lat: 40.570306,  Lng: -89.588192),  Route carried "on" structure: Other road ,  Year Built: 1962,  Status: Open,  Structure Length: 1.40m (4.59ft),  Average Daily Traffic: 1,000 (year 2018),  Truck Traffic: 7%,  Average Future Daily Traffic: 1,236 (year 2032),  Features Intersected: STREAM,  Facility Carried by Structure: COUNTRY CLUB DR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.304,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.8m (42.0ft),  Curb-To-Curb Width: 9.7m (31.8ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Satisfactory,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 42.8 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 20.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2022,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 903092,  Location: SW-29-T24NR4W (Lat: 40.499386,  Lng: -89.587050),  Route carried "on" structure: County highway ,  Year Built: 1957,  Status: Open,  Structure Length: 1.77m (5.81ft),  Average Daily Traffic: 175 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 242 (year 2032),  Features Intersected: LOST CREEK,  Facility Carried by Structure: RED SHALE HILL-TR1
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 5.134,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 16.8m (55.1ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 33.7 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 20.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 903166,  Location: SE-17-T24NR4W (Lat: 40.524700,  Lng: -89.576453),  Route carried "on" structure: County highway ,  Year Built: 1972,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 425 (year 2018),  Truck Traffic: 4%,  Average Future Daily Traffic: 591 (year 2032),  Design Load: HS 15,  Features Intersected: LOST CREEK,  Facility Carried by Structure: TR 116
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.186,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.9m (22.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.3m (40.4ft),  Curb-To-Curb Width: 7.8m (25.6ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 56.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 903194,  Location: SE-24-T24NR5W (Lat: 40.509558,  Lng: -89.608786),  Route carried "on" structure: County highway ,  Year Built: 1984,  Status: Open,  Structure Length: 1.89m (6.20ft),  Average Daily Traffic: 175 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 296 (year 2032),  Design Load: HS 20,  Features Intersected: STREAM,  Facility Carried by Structure: RED SHALE HILL-TR1
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.189,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.5m (24.6ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 18.0m (59.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 44.4 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: January 2021,  Deck Structure Type: Concrete Precast Panels
Find on map >>   Show street view

Structure Number: 903203,  Location: W JCT ILL 29 CH 16 (Lat: 40.538053,  Lng: -89.670817),  Route carried "on" structure: County highway ,  Year Built: 1984,  Status: Open,  Structure Length: 3.26m (10.70ft),  Average Daily Traffic: 4,800 (year 2018),  Truck Traffic: 12%,  Average Future Daily Traffic: 6,128 (year 2032),  Design Load: HS 20,  Features Intersected: LOST CREEK,  Facility Carried by Structure: POWERTON RD CH 16
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.257,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.8m (42.0ft)

Condition: Deck: Excellent,  Superstructure: Excellent,  Substructure: Good,  Channel: Good,  Operating Rating: 54.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Other Special Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Other Special Inspection Date: June 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 903218,  Location: 2 MI NW OF GROVELAND (Lat: 40.600631,  Lng: -89.569756),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 3.92m (12.86ft),  Average Daily Traffic: 1,400 (year 2018),  Truck Traffic: 2%,  Average Future Daily Traffic: 1,021 (year 2032),  Design Load: HS 20,  Features Intersected: BRANCH OF LICK CREEK,  Facility Carried by Structure: TR 128
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.435,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 15.8m (51.8ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Built-up
Find on map >>   Show street view

Structure Number: 903224,  Location: NW1/4-16-T24NR4W (Lat: 40.533083,  Lng: -89.557753),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 725 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 645 (year 2032),  Design Load: HS 20,  Features Intersected: LOST CREEK,  Facility Carried by Structure: TR 730(MAYFLOWER D
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.644,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Skew: 2 degrees,  Material/Design: Concrete,  Design/Construction: Frame,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 44.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported by rating factor (RF) using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2020
Find on map >>   Show street view

Structure Number: 729916,  Location: SEC 23 T7N,R7E (Lat: 40.572850,  Lng: -89.679733),  Route carried "under" structure: County highway ,  Year Built: 1926,  Structure Length: 0. m,  Average Daily Traffic: 25 (year 2017),  Truck Traffic: 80%,  Features Intersected: TR 317,  Facility Carried by Structure: C&NW RR (175543A)
Minimum Vertical Clearance: 4.11m (13.48ft),  Kilometerpoint: 1.996,  Lanes under structure: 2,  Material/Design: Concrete,  Design/Construction: Slab,  Length of Maximum Span: 10.1m (33.1ft)

Find on map >>   Show street view

Structure Number: 909902,  Location: E.CTR-16-T24NR5W (Lat: 40.532856,  Lng: -89.664500),  Route carried "under" structure: State highway 29,  Year Built: 1900,  Structure Length: 0. m,  Average Daily Traffic: 5,850 (year 2021),  Truck Traffic: 8%,  Features Intersected: ILL 29,  Facility Carried by Structure: CNW(175541L)
Minimum Vertical Clearance: 4.22m (13.85ft),  Kilometerpoint: 165.726,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Truss - Thru,  Length of Maximum Span: 11.6m (38.1ft)

Find on map >>   Show street view

Structure Number: 909905,  Location: SE COR-9-T24NR5W (Lat: 40.538047,  Lng: -89.668022),  Route carried "under" structure: County highway ,  Year Built: 1913,  Structure Length: 0. m,  Average Daily Traffic: 4,800 (year 2018),  Truck Traffic: 12%,  Features Intersected: FAS 461,  Facility Carried by Structure: CNW(175542T)
Minimum Vertical Clearance: 4.42m (14.50ft),  Kilometerpoint: 0.016,  Lanes under structure: 2,  Material/Design: Concrete,  Design/Construction: Slab,  Length of Maximum Span: 6.7m (22.0ft)

Discuss Pekin, Illinois (IL) on our hugely popular Illinois forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.