Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Naples, Texas (TX)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 15Number of bridges
  • 282ft / 86.1mTotal length
  • 12,303Total average daily traffic
  • 1,630Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Naples
  • No street view available for this location

New bridges in Naples, TX - historical statistics
  • New bridges - historical statistics
  • 11920-1929
  • 21930-1939
  • 31940-1949
  • 21950-1959
  • 51960-1969
  • 21990-1999
Average Bridge Daily Traffic in Naples, TX
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 42.9%Good
  • 57.1%Satisfactory
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 28.6%Good
  • 71.4%Satisfactory
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 28.6%Good
  • 28.6%Satisfactory
  • 42.9%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 23.1%Good
  • 46.2%Satisfactory
  • 30.8%Fair
Find on map >>   Show street view

Structure Number: 19019000101108,  Location: AT SULPHUR RIVER (Lat: 33.252181,  Lng: -94.623147),  Route carried "on" structure: US 67,  Year Built: 1942,  Status: Open,  Structure Length: 38.86m (127.49ft),  Average Daily Traffic: 708 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 1,580 (year 2033),  Design Load: H 15,  Features Intersected: SULPHUR RIVER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 25.206,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Material/Design: Steel continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Number Of Approach Spans: 27,  Length of Maximum Span: 22.9m (75.1ft),  Curb-To-Curb Width: 7.7m (25.3ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 41.7 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: June 2020,  Underwater Inspection Date: Febuary 2017,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 190340001010079,  Location: 3.60 MI NE OF SH 77 (Lat: 33.246464,  Lng: -94.631106),  Route carried "on" structure: US 67,  Year Built: 1941,  Status: Temporarily open,  Structure Length: 24.38m (79.99ft),  Average Daily Traffic: 953 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 1,510 (year 2033),  Design Load: H 15,  Features Intersected: JENNINGS SLOUGH
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.492,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 20,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 9.5m (31.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Good,  Operating Rating: 46.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 27.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 190340157402001,  Location: 0.0 MI SE OF MORRIS C/L (Lat: 33.153522,  Lng: -94.652369),  Route carried "on" structure: State highway 161,  Year Built: 1953,  Status: Open,  Structure Length: 1.55m (5.09ft),  Average Daily Traffic: 278 (year 2020),  Truck Traffic: 17%,  Average Future Daily Traffic: 490 (year 2033),  Features Intersected: FLOYD CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.005,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 6,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 8.3m (27.2ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 190340157402002,  Location: 0.10 MI SE OF MORRIS C/L (Lat: 33.152331,  Lng: -94.651778),  Route carried "on" structure: State highway 161,  Year Built: 1953,  Status: Open,  Structure Length: 1.31m (4.30ft),  Average Daily Traffic: 278 (year 2020),  Truck Traffic: 17%,  Average Future Daily Traffic: 490 (year 2033),  Features Intersected: WATSON CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.208,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 6.1m (20.0ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 190340291901001,  Location: 2.20 MI SE OF SH 77 (Lat: 33.177111,  Lng: -94.634972),  Route carried "on" structure: State highway 2888,  Year Built: 1965,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 235 (year 2020),  Truck Traffic: 16%,  Average Future Daily Traffic: 340 (year 2033),  Design Load: HS 20,  Features Intersected: DRAW
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.557,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 191720001008063,  Location: 2.75 MI W OF FM 144 (Lat: 33.188133,  Lng: -94.792869),  Route carried "on" structure: US 67,  Year Built: 1936,  Year Reconstructed: 1965,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 3,078 (year 2020),  Truck Traffic: 11%,  Average Future Daily Traffic: 4,880 (year 2033),  Features Intersected: BOGGY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.239,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 14.0m (45.9ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 14.5m (47.6ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Channel: Fair,  Culverts: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 191720001008137,  Location: 0.00 MI NW OF US 67 (Lat: 33.209303,  Lng: -94.673000),  Route carried "on" structure: State highway 77,  Year Built: 1969,  Status: Open,  Structure Length: 10.82m (35.50ft),  Average Daily Traffic: 530 (year 2013),  Truck Traffic: 15%,  Average Future Daily Traffic: 740 (year 2033),  Design Load: H 20,  Features Intersected: US 67 JOHNSON ST UPRR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 7.590,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 18.3m (60.0ft),  Curb-To-Curb Width: 13.3m (43.6ft),  Out-to-Out Width: 13.9m (45.6ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 53.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 29.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 191720001008147,  Location: 1.00 MI NE OF SH 77 (Lat: 33.222156,  Lng: -94.663367),  Route carried "on" structure: US 67,  Year Built: 1942,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 916 (year 2020),  Truck Traffic: 15%,  Average Future Daily Traffic: 1,550 (year 2033),  Features Intersected: CANEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.972,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft),  Curb-To-Curb Width: 12.7m (41.7ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 191720062201003,  Location: 0.50 MI S OF FM 161 (Lat: 33.179322,  Lng: -94.675539),  Route carried "on" structure: State highway 338,  Year Built: 1962,  Status: Open,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 1,372 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 1,900 (year 2033),  Design Load: HS 20,  Features Intersected: GIN CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 19.262,  Lanes on structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 15.9m (52.2ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 23.0m (75.5ft)

Condition: Channel: Satisfactory,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 191720062201004,  Location: 2.20 MI S OF FM 161 (Lat: 33.156286,  Lng: -94.686008),  Route carried "on" structure: State highway 338,  Year Built: 1964,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 1,372 (year 2020),  Truck Traffic: 14%,  Average Future Daily Traffic: 1,900 (year 2033),  Design Load: HS 20,  Features Intersected: WATSON CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 21.993,  Lanes on structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Good,  Culverts: Satisfactory,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 23.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020
Find on map >>   Show street view

Structure Number: 191720AA0148001,  Location: 0.5 MI NE OF US 67 (Lat: 33.222872,  Lng: -94.668344),  Route carried "on" structure: County highway 4321,  Year Built: 1933,  Status: Posted for load,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 25 (year 2013),  Average Future Daily Traffic: 25 (year 2033),  Features Intersected: LITTLE CANEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.805,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 3.4m (11.2ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 6.3m (20.7ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Fair,  Channel: Fair,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 191720AA0148002,  Location: 1.3 MI NE OF US 67 (Lat: 33.232819,  Lng: -94.661631),  Route carried "on" structure: County highway 4321,  Year Built: 1925,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 25 (year 2013),  Average Future Daily Traffic: 25 (year 2033),  Features Intersected: CANEY CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 2.092,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 3.7m (12.1ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 6.3m (20.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 191720AA0170001,  Location: 0.3 MI W OF FM 161 (Lat: 33.173533,  Lng: -94.665725),  Route carried "on" structure: County highway 4304,  Year Built: 1991,  Status: Open,  Structure Length: 1.28m (4.20ft),  Average Daily Traffic: 23 (year 2013),  Average Future Daily Traffic: 23 (year 2033),  Features Intersected: WATSON CREEK TRIBUTARY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.483,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 3.0m (9.8ft),  Material/Design: Steel,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.9m (39.0ft),  Curb-To-Curb Width: 5.8m (19.0ft),  Out-to-Out Width: 5.8m (19.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Steel plate,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 191720AA4207001,  Location: 1.9 MI S OF SH 338 (Lat: 33.151378,  Lng: -94.669067),  Route carried "on" structure: County highway 4207,  Year Built: 1993,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 30 (year 2013),  Average Future Daily Traffic: 30 (year 2033),  Features Intersected: WATSON CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.058,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 3.7m (12.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.2m (26.9ft),  Curb-To-Curb Width: 5.5m (18.0ft),  Out-to-Out Width: 5.5m (18.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Good,  Operating Rating: 32.7 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.5 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2020,  Deck Structure Type: Steel plate,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Structure Number: 191720001008137,  Location: 0.00 MI NW OF US 67,  Route carried "under" structure: US 67,  Year Built: 1969,  Structure Length: 0. m,  Average Daily Traffic: 2,480 (year 2013),  Truck Traffic: 13%,  Features Intersected: US 67 JOHNSON ST UPRR,  Facility Carried by Structure: SH 77
Minimum Vertical Clearance: 8.10m (26.57ft),  Kilometerpoint: 2.700,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.3m (60.0ft)

Discuss Naples, Texas (TX) on our hugely popular Texas forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.