Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Fountain Valley, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 24Number of bridges
  • 341ft / 104mTotal length
  • 2,704,300Total average daily traffic
  • 155,759Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Fountain Valley
  • No street view available for this location

New bridges in Fountain Valley, CA - historical statistics
  • New bridges - historical statistics
  • 191960-1969
  • 11970-1979
  • 11980-1989
  • 22010-2019
  • 12020-2022
Average Bridge Daily Traffic in Fountain Valley, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 88.9%Good
  • 11.1%Fair
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 88.9%Good
  • 11.1%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 66.7%Good
  • 11.1%Satisfactory
  • 22.2%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.3%Excellent
  • 66.7%Very good
Find on map >>   Show street view

Structure Number: 55 0261,  Location: 12-ORA-405-14.13-FNV (Lat: 33.708808,  Lng: -117.959100),  Route carried "on" structure: City street M029,  Year Built: 1966,  Status: Open,  Structure Length: 9.63m (31.59ft),  Average Daily Traffic: 10,000 (year 2011),  Truck Traffic: 3%,  Average Future Daily Traffic: 11,797 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: ROUTE 405,  Facility Carried by Structure: SLATER AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 11,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 39.0m (128.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 19.5m (64.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 55 0262,  Location: 12-ORA-405-14.50-FNV (Lat: 33.712144,  Lng: -117.962997),  Route carried "on" structure: City street M075,  Year Built: 1966,  Status: Open,  Structure Length: 9.20m (30.18ft),  Average Daily Traffic: 10,000 (year 2011),  Truck Traffic: 3%,  Average Future Daily Traffic: 11,797 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: ROUTE 405,  Facility Carried by Structure: BUSHARD ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 10,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 34.4m (112.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 18.6m (61.0ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 55 0402,  Location: 12-ORA-405-13.78-FNV (Lat: 33.704542,  Lng: -117.954208),  Route carried "on" structure: City street M004,  Year Built: 1966,  Status: Open,  Structure Length: 13.62m (44.69ft),  Average Daily Traffic: 20,000 (year 2011),  Truck Traffic: 3%,  Average Future Daily Traffic: 23,592 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: INTERSTATE 405,  Facility Carried by Structure: BROOKHURST ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 8,  Lanes under structure: 14,  Owner: State Highway Agency,  Approaching Roadway Width: 30.5m (100.1ft),  Skew: 24 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 35.7m (117.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 30.5m (100.1ft),  Out-to-Out Width: 36.6m (120.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 55 0421F,  Location: 12-ORA-405-8.65-IRVN (Lat: 33.686958,  Lng: -117.870911),  Route carried "on" structure: Ramp Interstate 405,  Year Built: 1968,  Status: Open,  Structure Length: 13.20m (43.31ft),  Average Daily Traffic: 28,500 (year 2011),  Truck Traffic: 5%,  Average Future Daily Traffic: 33,619 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: I 405 & N405-S55 CONN
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 8.650,  Lanes on structure: 2,  Lanes under structure: 12,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 9 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 30.5m (100.1ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.0m,  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 55 0429,  Location: 12-ORA-405-13.15-FNV (Lat: 33.699667,  Lng: -117.945603),  Route carried "on" structure: City street M076,  Year Built: 1966,  Status: Open,  Structure Length: 7.68m (25.20ft),  Average Daily Traffic: 5,000 (year 2021),  Truck Traffic: 3%,  Average Future Daily Traffic: 5,898 (year 2043),  Design Load: HS 20+Mod,  Features Intersected: INTERSTATE 405,  Facility Carried by Structure: WARD ST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 12,  Owner: State Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 22 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 27.1m (88.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m,  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 11.3m (37.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 55 0477,  Location: 12-ORA-405-12.90-FNV (Lat: 33.698553,  Lng: -117.941517),  Route carried "on" structure: Interstate 405,  Year Built: 1966,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 302,000 (year 2011),  Truck Traffic: 6%,  Average Future Daily Traffic: 432,000 (year 2038),  Features Intersected: EAST VALLEY CHANNEL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 12.900,  Lanes on structure: 13,  Base Highway Network: Yes (Inventory Route: 4,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 51.5m (169.0ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb-To-Curb Width: 51.5m (169.0ft),  Out-to-Out Width: 52.5m (172.2ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 55 0478,  Location: 12-ORA-405-15.00-FNV (Lat: 33.717586,  Lng: -117.968708),  Route carried "on" structure: Interstate 405,  Year Built: 1966,  Status: Open,  Structure Length: 1.25m (4.10ft),  Average Daily Traffic: 263,000 (year 2011),  Truck Traffic: 7%,  Average Future Daily Traffic: 362,000 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: OCEAN VIEW CHANNEL
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 15.000,  Lanes on structure: 13,  Base Highway Network: Yes (Inventory Route: 4,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 64.0m (210.0ft),  Skew: 35 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.2m (20.3ft),  Curb-To-Curb Width: 64.0m (210.0ft),  Out-to-Out Width: 65.0m (213.3ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021
Find on map >>   Show street view

Structure Number: 55 1121,  Location: 12-ORA-405-15.21-HNTB (Lat: 33.719250,  Lng: -117.971722),  Route carried "on" structure: City street ,  Year Built: 2021,  Status: Open,  Structure Length: 13.54m (44.42ft),  Average Daily Traffic: 254,000 (year 2021),  Truck Traffic: 7%,  Average Future Daily Traffic: 320,000 (year 2040),  Design Load: HL 93,  Features Intersected: ROUTE 405,  Facility Carried by Structure: MAGNOLIA STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 11,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 31.0m (101.7ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 71.8m (235.6ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 28.0m (91.9ft),  Out-to-Out Width: 35.2m (115.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 55 1122,  Location: 12-ORA-405-14.13-FNV (Lat: 33.708833,  Lng: -117.959056),  Route carried "on" structure: City street M029,  Year Built: 2019,  Status: Open,  Structure Length: 10.05m (32.97ft),  Average Daily Traffic: 20,000 (year 2016),  Truck Traffic: 3%,  Average Future Daily Traffic: 11,797 (year 2038),  Design Load: HS 20,  Features Intersected: ROUTE 405,  Facility Carried by Structure: SLATER AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Lanes under structure: 11,  Owner: State Highway Agency,  Approaching Roadway Width: 17.7m (58.1ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 53.1m (174.2ft),  Curb or Sidewalk Widths: Left: 1.8m (5.9ft),  Right: 1.8m (5.9ft),  Curb-To-Curb Width: 17.7m (58.1ft),  Out-to-Out Width: 21.9m (71.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: August 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 55C0095,  Location: 0.3 MI. S/O ELLIS AVENUE (Lat: 33.690469,  Lng: -117.953950),  Route carried "on" structure: City street ,  Year Built: 1966,  Status: Open,  Structure Length: 0.91m (2.99ft),  Average Daily Traffic: 47,000 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 97,829 (year 2040),  Features Intersected: FOUNTAIN VALLEY CHANNEL,  Facility Carried by Structure: BROOKHURST STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 26.2m (86.0ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 26.2m (86.0ft),  Out-to-Out Width: 36.6m (120.1ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 55C0097,  Location: 0.6 MI W/O HARBOR BLVD. (Lat: 33.701811,  Lng: -117.930811),  Route carried "on" structure: County highway ,  Year Built: 1983,  Status: Open,  Structure Length: 11.00m (36.09ft),  Average Daily Traffic: 26,000 (year 2018),  Truck Traffic: 1%,  Average Future Daily Traffic: 54,119 (year 2039),  Design Load: HS 20,  Features Intersected: SANTA ANA RIVER CHANNEL,  Facility Carried by Structure: TALBERT/MACARTHUR
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 20.7m (67.9ft),  Skew: 3 degrees,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 29.9m (98.1ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 24.4m (80.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Excellent,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: January 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 55C037,  Location: 0.3 MI W/O BRISTOL ST (Lat: 33.707322,  Lng: -117.891069),  Route carried "on" structure: City street ,  Year Built: 1965,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 22,000 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 49,330 (year 2041),  Features Intersected: SANTA ANA GARDENS CHA,  Facility Carried by Structure: SEGERSTROM AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Base Highway Network: Yes,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 30 degrees,  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 3.0m (9.8ft),  Right: 2.7m (8.9ft),  Curb-To-Curb Width: 15.2m (49.9ft),  Out-to-Out Width: 25.8m (84.6ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: Febuary 2021
Find on map >>   Show street view

Structure Number: 55C0371,  Location: 0.3 MI. W/O HARBOR BLVD. (Lat: 33.708975,  Lng: -117.926083),  Route carried "on" structure: County highway ,  Year Built: 1974,  Year Reconstructed: 1982,  Status: Open,  Structure Length: 10.00m (32.81ft),  Average Daily Traffic: 30,000 (year 2019),  Truck Traffic: 1%,  Average Future Daily Traffic: 48,034 (year 2038),  Design Load: HS 20,  Features Intersected: SANTA ANA RIVER CHANNEL,  Facility Carried by Structure: SEGERSTROM-SLATER
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: County Highway Agency,  Approaching Roadway Width: 20.1m (65.9ft),  Skew: 1 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 5,  Length of Maximum Span: 21.9m (71.9ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 23.2m (76.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Excellent,  Operating Rating: 46.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 55C0379,  Location: 0.25 MI. W/O BUSHARD ST. (Lat: 33.693950,  Lng: -117.967239),  Route carried "on" structure: City street ,  Year Built: 1969,  Status: Open,  Structure Length: 0.79m (2.59ft),  Average Daily Traffic: 22,000 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 45,792 (year 2040),  Design Load: HS 20,  Features Intersected: TALBERT CHANNEL,  Facility Carried by Structure: ELLIS AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 19.5m (64.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.4m (7.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.5m (8.2ft),  Curb-To-Curb Width: 19.5m (64.0ft),  Out-to-Out Width: 25.0m (82.0ft)

Condition: Channel: Excellent,  Culverts: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 55C0381,  Location: 0.1 MI. E/O BROOKHURST ST (Lat: 33.694047,  Lng: -117.952092),  Route carried "on" structure: City street ,  Year Built: 1966,  Status: Open,  Structure Length: 0.88m (2.89ft),  Average Daily Traffic: 22,000 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 45,792 (year 2040),  Features Intersected: FOUNTAIN VALLEY CHANNEL,  Facility Carried by Structure: ELLIS AVENUE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 19.2m (63.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 2.7m (8.9ft),  Curb or Sidewalk Widths: Left: 2.6m (8.5ft),  Right: 2.4m (7.9ft),  Curb-To-Curb Width: 19.2m (63.0ft),  Out-to-Out Width: 25.0m (82.0ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 55C0466,  Location: 0.1 MI. N/O WARNER AVENUE (Lat: 33.717792,  Lng: -117.963083),  Route carried "on" structure: City street ,  Year Built: 1961,  Status: Open,  Structure Length: 0.67m (2.20ft),  Average Daily Traffic: 14,000 (year 2021),  Truck Traffic: 1%,  Average Future Daily Traffic: 44,003 (year 2040),  Design Load: HS 20,  Features Intersected: OCEAN VIEW CHANNEL,  Facility Carried by Structure: BUSHARD STREET
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 19.3m (63.3ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.0m (9.8ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 2.6m (8.5ft),  Curb-To-Curb Width: 19.3m (63.3ft),  Out-to-Out Width: 24.7m (81.0ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 55 026,  Location: 12-ORA-405-13.41-FNV (Lat: 33.701658,  Lng: -117.950033),  Route carried "under" structure: Interstate 405,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 262,000 (year 2020),  Truck Traffic: 4%,  Features Intersected: ROUTE 405,  Facility Carried by Structure: TALBERT AVE
Minimum Vertical Clearance: 5.79m (19.00ft),  Kilometerpoint: 13.410,  Lanes on structure: 4,  Lanes under structure: 12,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 45.1m (148.0ft)

Find on map >>   Show street view

Structure Number: 55 0261,  Location: 12-ORA-405-14.13-FNV (Lat: 33.708808,  Lng: -117.959100),  Route carried "under" structure: Interstate 405,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 263,000 (year 2011),  Truck Traffic: 7%,  Features Intersected: ROUTE 405,  Facility Carried by Structure: SLATER AVE
Minimum Vertical Clearance: 5.33m (17.49ft),  Kilometerpoint: 14.130,  Lanes on structure: 4,  Lanes under structure: 11,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 39.0m (128.0ft)

Find on map >>   Show street view

Structure Number: 55 0262,  Location: 12-ORA-405-14.50-FNV (Lat: 33.712144,  Lng: -117.962997),  Route carried "under" structure: Interstate 405,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 263,000 (year 2011),  Truck Traffic: 7%,  Features Intersected: ROUTE 405,  Facility Carried by Structure: BUSHARD ST
Minimum Vertical Clearance: 5.20m (17.06ft),  Kilometerpoint: 14.500,  Lanes on structure: 4,  Lanes under structure: 10,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 34.4m (112.9ft)

Find on map >>   Show street view

Structure Number: 55 0402,  Location: 12-ORA-405-13.78-FNV (Lat: 33.704542,  Lng: -117.954208),  Route carried "under" structure: Interstate 405,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 263,000 (year 2011),  Truck Traffic: 7%,  Features Intersected: INTERSTATE 405,  Facility Carried by Structure: BROOKHURST ST
Minimum Vertical Clearance: 5.23m (17.16ft),  Kilometerpoint: 13.780,  Lanes on structure: 8,  Lanes under structure: 10,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 35.7m (117.1ft)

Find on map >>   Show street view

Structure Number: 55 0402,  Location: 12-ORA-405-13.78-FNV (Lat: 33.704542,  Lng: -117.954208),  Route carried "under" structure: Ramp Interstate 405,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 9,300 (year 2011),  Truck Traffic: 3%,  Features Intersected: INTERSTATE 405,  Facility Carried by Structure: BROOKHURST ST
Minimum Vertical Clearance: 5.05m (16.57ft),  Kilometerpoint: 13.780,  Lanes on structure: 8,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 35.7m (117.1ft)

Find on map >>   Show street view

Structure Number: 55 0402,  Location: 12-ORA-405-13.78-FNV (Lat: 33.704542,  Lng: -117.954208),  Route carried "under" structure: Ramp Interstate 405,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 8,500 (year 2011),  Truck Traffic: 3%,  Features Intersected: INTERSTATE 405,  Facility Carried by Structure: BROOKHURST ST
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 13.780,  Lanes on structure: 8,  Lanes under structure: 2,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 35.7m (117.1ft)

Find on map >>   Show street view

Structure Number: 55 0429,  Location: 12-ORA-405-13.15-FNV (Lat: 33.699667,  Lng: -117.945603),  Route carried "under" structure: Interstate 405,  Year Built: 1966,  Structure Length: 0. m,  Average Daily Traffic: 260,000 (year 2020),  Truck Traffic: 4%,  Features Intersected: INTERSTATE 405,  Facility Carried by Structure: WARD ST
Minimum Vertical Clearance: 5.25m (17.22ft),  Kilometerpoint: 13.150,  Lanes on structure: 2,  Lanes under structure: 12,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 27.1m (88.9ft)

Find on map >>   Show street view

Structure Number: 55 1122,  Location: 12-ORA-405-14.13-FNV (Lat: 33.708833,  Lng: -117.959056),  Route carried "under" structure: Interstate 405,  Year Built: 2019,  Structure Length: 0. m,  Average Daily Traffic: 280,000 (year 2019),  Truck Traffic: 7%,  Features Intersected: ROUTE 405,  Facility Carried by Structure: SLATER AVENUE
Minimum Vertical Clearance: 6.20m (20.34ft),  Kilometerpoint: 14.130,  Lanes on structure: 4,  Lanes under structure: 11,  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 53.1m (174.2ft)

Discuss Fountain Valley, California (CA) on our hugely popular California forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.