Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for El Dorado Hills, California (CA)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 26Number of bridges
  • 292ft / 89.4mTotal length
  • $4,399,000Total costs
  • 511,416Total average daily traffic
  • 30,931Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for El Dorado Hills
  • No street view available for this location

New bridges in El Dorado Hills, CA - historical statistics
  • New bridges - historical statistics
  • 11910-1919
  • 21930-1939
  • 11950-1959
  • 21960-1969
  • 11970-1979
  • 11980-1989
  • 21990-1999
  • 52000-2009
  • 112010-2019
Reconstructed bridges in El Dorado Hills, CA - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 01970-1979
  • 01980-1989
  • 01990-1999
  • 22000-2009
Average Bridge Daily Traffic in El Dorado Hills, CA
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 47.1%Good
  • 47.1%Fair
  • 5.9%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 83.3%Good
  • 16.7%Fair
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 83.3%Good
  • 16.7%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 33.3%Very good
  • 41.7%Good
  • 16.7%Satisfactory
  • 8.3%Fair
Find on map >>   Show street view

Structure Number: 25 0072,  Location: 03-ED-050-R1.66 (Lat: 38.657206,  Lng: -121.057158),  Route carried "on" structure: US 50,  Year Built: 1965,  Year Reconstructed: 2009,  Status: Open,  Structure Length: 3.35m (10.99ft),  Average Daily Traffic: 95,000 (year 2012),  Truck Traffic: 6%,  Average Future Daily Traffic: 159,000 (year 2037),  Design Load: HL 93,  Features Intersected: OLD SILVA VALLEY PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.660,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 41.4m (135.8ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 40.5m (132.9ft),  Out-to-Out Width: 41.4m (135.8ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 33.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 25.6 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 25 0072K,  Location: 03-ED-050-R1.65 (Lat: 38.657597,  Lng: -121.057372),  Route carried "on" structure: Ramp US 50,  Year Built: 2015,  Status: Open,  Structure Length: 3.52m (11.55ft),  Average Daily Traffic: 10,000 (year 2015),  Truck Traffic: 6%,  Average Future Daily Traffic: 14,378 (year 2042),  Design Load: HL 93,  Features Intersected: OLD SILVA VALLEY PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.650,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.8m (48.6ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 25 0072S,  Location: 03-ED-050-R1.66 (Lat: 38.656994,  Lng: -121.057028),  Route carried "on" structure: US 50,  Year Built: 2015,  Status: Open,  Structure Length: 3.89m (12.76ft),  Average Daily Traffic: 10,000 (year 2015),  Truck Traffic: 6%,  Average Future Daily Traffic: 15,000 (year 2037),  Design Load: HL 93,  Features Intersected: OLD SILVA VALLEY PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.660,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes,  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 2 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 37.9m (124.3ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 25 0073,  Location: 03-ED-050-R3.24 (Lat: 38.655356,  Lng: -121.030011),  Route carried "on" structure: US 50,  Year Built: 1966,  Year Reconstructed: 2013,  Status: Open,  Structure Length: 3.78m (12.40ft),  Average Daily Traffic: 60,000 (year 2009),  Truck Traffic: 6%,  Average Future Daily Traffic: 105,000 (year 2037),  Design Load: HL 93,  Features Intersected: BASS LAKE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 3.240,  Lanes on structure: 6,  Lanes under structure: 2,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 33.9m (111.2ft),  Skew: 30 degrees,  Material/Design: Concrete continuous,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 33.9m (111.2ft),  Out-to-Out Width: 35.5m (116.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 37.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 26.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 25 0079,  Location: 03-ED-050-R1.90L (Lat: 38.658025,  Lng: -121.052900),  Route carried "on" structure: US 50,  Year Built: 1939,  Year Reconstructed: 1965,  Status: Open,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 72,000 (year 2012),  Truck Traffic: 6%,  Average Future Daily Traffic: 119,000 (year 2037),  Features Intersected: CARSON CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.900,  Lanes on structure: 6,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 50.2m (164.7ft),  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 3.0m (9.8ft)

Condition: Channel: Satisfactory,  Culverts: Good,  Operating Rating: 40.5 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 24.3 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020
Find on map >>   Show street view

Structure Number: 25 0122,  Location: 03-ED-050-0.86 (Lat: 38.652650,  Lng: -121.070858),  Route carried "on" structure: US 50,  Year Built: 2009,  Status: Open,  Structure Length: 6.16m (20.21ft),  Average Daily Traffic: 72,000 (year 2009),  Truck Traffic: 6%,  Average Future Daily Traffic: 122,828 (year 2042),  Design Load: HL 93,  Features Intersected: LATROBE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.860,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 45.7m (149.9ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.1m (98.8ft),  Curb-To-Curb Width: 41.5m (136.2ft),  Out-to-Out Width: 43.0m (141.1ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 6.16m (20.21ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Bridge Improvement Cost: $2,619,000,  Roadway Improvement Cost: $523,000,  Total Project Cost: $4,399,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 25 0122K,  Location: 03-ED-050-0.85 (Lat: 38.653078,  Lng: -121.071097),  Route carried "on" structure: Ramp US 50,  Year Built: 2013,  Status: Open,  Structure Length: 6.16m (20.21ft),  Average Daily Traffic: 12,000 (year 2012),  Truck Traffic: 6%,  Average Future Daily Traffic: 15,500 (year 2037),  Design Load: HL 93,  Features Intersected: LATROBE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.850,  Lanes on structure: 2,  Lanes under structure: 8,  Base Highway Network: Yes (Inventory Route: 50,  Subroute: 2),  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.1m (98.8ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Underclear: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 25 0122S,  Location: 03-ED-050-0.86 (Lat: 38.652483,  Lng: -121.070772),  Route carried "on" structure: US 50,  Year Built: 2009,  Status: Open,  Structure Length: 6.16m (20.21ft),  Average Daily Traffic: 12,000 (year 2012),  Truck Traffic: 6%,  Average Future Daily Traffic: 15,500 (year 2037),  Design Load: HL 93,  Features Intersected: LATROBE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.860,  Lanes on structure: 1,  Lanes under structure: 8,  Base Highway Network: Yes (,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 30.1m (98.8ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 11.9m (39.0ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 25 0127,  Location: 03-ED-050-R1.81L (Lat: 38.658278,  Lng: -121.054519),  Route carried "on" structure: Business County highway ,  Year Built: 2015,  Status: Open,  Structure Length: 8.50m (27.89ft),  Average Daily Traffic: 10,000 (year 2015),  Truck Traffic: 6%,  Average Future Daily Traffic: 15,000 (year 2037),  Design Load: HL 93,  Features Intersected: US 50,  Facility Carried by Structure: SILVA PARKWAY
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 6,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 27.7m (90.9ft),  Skew: 30 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 42.7m (140.1ft),  Curb-To-Curb Width: 27.7m (90.9ft),  Out-to-Out Width: 30.5m (100.1ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 25 0130K,  Location: 03-ED-050-R1.90L (Lat: 38.659306,  Lng: -121.053306),  Route carried "on" structure: Ramp US 50,  Year Built: 2015,  Status: Open,  Structure Length: 7.83m (25.69ft),  Average Daily Traffic: 4,000 (year 2015),  Truck Traffic: 6%,  Average Future Daily Traffic: 6,400 (year 2037),  Design Load: HL 93,  Features Intersected: CARSON CREEK
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 1.900,  Lanes on structure: 3,  Owner: State Highway Agency,  Approaching Roadway Width: 14.6m (47.9ft),  Material/Design: Concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 31.1m (102.0ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.5m (50.9ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 42.1 metric tons,  Method Used To Determine Operating Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned ratings based on Load and Resistance Factor Design (LRFD) reported by rating factor (RF) using HL93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 25C0035,  Location: 4.6 MI SOUTH U.S. 50 (Lat: 38.600269,  Lng: -121.022536),  Route carried "on" structure: County highway ,  Year Built: 1987,  Status: Open,  Structure Length: 7.01m (23.00ft),  Average Daily Traffic: 4,879 (year 2013),  Truck Traffic: 10%,  Average Future Daily Traffic: 6,471 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: DEER CREEK,  Facility Carried by Structure: LATROBE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 4 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 7,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 12.4m (40.7ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 25C0036,  Location: 1.2 MI N GREEN VALLEY RD (Lat: 38.724025,  Lng: -121.071461),  Route carried "on" structure: County highway ,  Year Built: 1975,  Status: Open,  Structure Length: 2.53m (8.30ft),  Average Daily Traffic: 2,239 (year 2012),  Truck Traffic: 10%,  Average Future Daily Traffic: 4,304 (year 2040),  Features Intersected: NEW YORK CREEK,  Facility Carried by Structure: SALMON FALLS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 5 degrees,  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 9.7m (31.8ft),  Out-to-Out Width: 9.9m (32.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 86.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 51.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 25C0037,  Location: 4.5 MI S PILOT HILL (Lat: 38.772708,  Lng: -121.037522),  Route carried "on" structure: County highway ,  Year Built: 1953,  Status: Open,  Structure Length: 15.54m (50.98ft),  Average Daily Traffic: 1,900 (year 2012),  Truck Traffic: 10%,  Average Future Daily Traffic: 4,304 (year 2040),  Design Load: H 15,  Features Intersected: SOUTH FK AMERICAN RIVER,  Facility Carried by Structure: SALMON FALLS RD
Minimum Vertical Clearance: 4.54m (14.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Base Highway Network: Yes,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Truss - Thru,  Number Of Spans In Main Unit: 1,  Number Of Approach Spans: 4,  Length of Maximum Span: 69.5m (228.0ft),  Curb or Sidewalk Widths: Left: 0.3m (1.0ft),  Right: 0.3m (1.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.0m (29.5ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Good,  Operating Rating: 29.5 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 18.5 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Critical Feature Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Critical Feature Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 25C0095,  Location: 0.2 MI E SALMON FALLS RD (Lat: 38.712256,  Lng: -121.075303),  Route carried "on" structure: County highway ,  Year Built: 1932,  Status: Open,  Structure Length: 1.13m (3.71ft),  Average Daily Traffic: 963 (year 2009),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,130 (year 2040),  Features Intersected: NEW YORK CREEK,  Facility Carried by Structure: MALCOLM-DIXON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.8m (19.0ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.7m (35.1ft),  Curb or Sidewalk Widths: Left: 0.1m (0.3ft),  Right: 0.1m (0.3ft),  Curb-To-Curb Width: 5.8m (19.0ft),  Out-to-Out Width: 7.2m (23.6ft)

Condition: Deck: Good,  Superstructure: Fair,  Substructure: Fair,  Channel: Fair,  Operating Rating: 25.6 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 15.6 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 25C0112,  Location: 1.1 MI E OF LATROBE RD (Lat: 38.654944,  Lng: -121.052686),  Route carried "on" structure: County highway ,  Year Built: 1918,  Status: Open,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 100 (year 2011),  Truck Traffic: 10%,  Average Future Daily Traffic: 319 (year 2040),  Features Intersected: CARSON CREEK,  Facility Carried by Structure: OLD WHITE ROCK RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 5.5m (18.0ft),  Material/Design: Concrete continuous,  Design/Construction: Slab,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 5.2m (17.1ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 6.4m (21.0ft),  Out-to-Out Width: 7.2m (23.6ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Good,  Channel: Good,  Operating Rating: 26.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 25C0123,  Location: EAST OF ED HILLS BLVD. (Lat: 38.674117,  Lng: -121.059939),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 2.22m (7.28ft),  Average Daily Traffic: 5,414 (year 2013),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,636 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: ALLEGHENY CREEK,  Facility Carried by Structure: SERRANO PKWAY WEST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.3m (69.9ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.1m (39.7ft)

Condition: Deck: Fair,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 25C0124,  Location: EAST OF ED HILLS BLVD. (Lat: 38.675031,  Lng: -121.057658),  Route carried "on" structure: County highway ,  Year Built: 1998,  Status: Open,  Structure Length: 1.26m (4.13ft),  Average Daily Traffic: 6,200 (year 2013),  Truck Traffic: 4%,  Average Future Daily Traffic: 2,636 (year 2040),  Design Load: HS 20+Mod,  Features Intersected: ALLEGHENY CREEK,  Facility Carried by Structure: SERRANO PKWAY EAST
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.5m (37.7ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.3m (37.1ft),  Curb-To-Curb Width: 11.5m (37.7ft),  Out-to-Out Width: 12.2m (40.0ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2018,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 25C0127,  Location: W OF CARSON CRK RESERVOIR (Lat: 38.635519,  Lng: -121.060944),  Route carried "on" structure: County highway ,  Year Built: 2009,  Status: Open,  Structure Length: 3.00m (9.84ft),  Average Daily Traffic: 4,879 (year 2013),  Truck Traffic: 10%,  Average Future Daily Traffic: 6,471 (year 2042),  Design Load: HS 20+Mod,  Features Intersected: CARSON CREEK,  Facility Carried by Structure: LATROBE ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 25.2m (82.7ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 30.0m (98.4ft),  Curb-To-Curb Width: 25.2m (82.7ft),  Out-to-Out Width: 26.3m (86.3ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Fair,  Channel: Satisfactory,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Assigned rating based on Load Factor Design (LFD) reported in metric tons,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2020,  Deck Structure Type: Concrete Cast-file-Place
Find on map >>   Show street view

Structure Number: 25C0142,  Location: 0.9 MI E/O LATROBE ROAD (Lat: 38.653572,  Lng: -121.055819),  Route carried "on" structure: County highway ,  Year Built: 2014,  Status: Open,  Structure Length: 3.62m (11.88ft),  Average Daily Traffic: 9,442 (year 2012),  Truck Traffic: 2%,  Average Future Daily Traffic: 13,306 (year 2040),  Features Intersected: BUCKS RAVINE CREEK,  Facility Carried by Structure: WHITE ROCK ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 5,  Owner: County Highway Agency,  Approaching Roadway Width: 23.5m (77.1ft),  Skew: 34 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 2.5m (8.2ft),  Curb-To-Curb Width: 23.5m (77.1ft),  Out-to-Out Width: 37.4m (122.7ft)

Condition: Channel: Very good,  Culverts: Good,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2018
Find on map >>   Show street view

Structure Number: 25C0143,  Location: 0.2 MI E/O SILVA VLY PKWY (Lat: 38.660019,  Lng: -121.052133),  Route carried "on" structure: Spur County highway ,  Year Built: 2014,  Status: Open,  Structure Length: 1.10m (3.61ft),  Average Daily Traffic: 400 (year 2016),  Truck Traffic: 1%,  Average Future Daily Traffic: 500 (year 2036),  Features Intersected: CARSON CREEK,  Facility Carried by Structure: TONG ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Arch - Deck,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Superstructure: Good,  Substructure: Good,  Channel: Very good,  Operating Rating: 54.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: June 2018
Find on map >>   Show street view

Structure Number: 25 0072K,  Location: 03-ED-050-R1.65 (Lat: 38.657597,  Lng: -121.057372),  Route carried "under" structure: Business County highway ,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 8,000 (year 2015),  Truck Traffic: 10%,  Features Intersected: OLD SILVA VALLEY PARKWAY,  Facility Carried by Structure: WB 50 ON-RAMP
Minimum Vertical Clearance: 4.75m (15.58ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete continuous,  Design/Construction: Slab,  Length of Maximum Span: 14.8m (48.6ft)

Find on map >>   Show street view

Structure Number: 25 0072S,  Location: 03-ED-050-R1.66 (Lat: 38.656994,  Lng: -121.057028),  Route carried "under" structure: Business County highway ,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 8,000 (year 2015),  Truck Traffic: 10%,  Features Intersected: OLD SILVA VALLEY PARKWAY,  Facility Carried by Structure: EB 50 OFF-RAMP
Minimum Vertical Clearance: 5.94m (19.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 37.9m (124.3ft)

Find on map >>   Show street view

Structure Number: 25 0122,  Location: 03-ED-050-0.86 (Lat: 38.652650,  Lng: -121.070858),  Route carried "under" structure: County highway ,  Year Built: 2009,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2012),  Truck Traffic: 5%,  Features Intersected: LATROBE ROAD,  Facility Carried by Structure: US HIGHWAY 50
Minimum Vertical Clearance: 4.74m (15.55ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 30.1m (98.8ft)

Find on map >>   Show street view

Structure Number: 25 0122K,  Location: 03-ED-050-0.85 (Lat: 38.653078,  Lng: -121.071097),  Route carried "under" structure: City street ,  Year Built: 2013,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2012),  Truck Traffic: 5%,  Features Intersected: LATROBE ROAD,  Facility Carried by Structure: HWY 50
Minimum Vertical Clearance: 4.72m (15.49ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 30.1m (98.8ft)

Find on map >>   Show street view

Structure Number: 25 0122S,  Location: 03-ED-050-0.86 (Lat: 38.652483,  Lng: -121.070772),  Route carried "under" structure: County highway ,  Year Built: 2009,  Structure Length: 0. m,  Average Daily Traffic: 10,000 (year 2012),  Truck Traffic: 5%,  Features Intersected: LATROBE ROAD,  Facility Carried by Structure: EB 50-NB LATROBE
Minimum Vertical Clearance: 5.11m (16.77ft),  Kilometerpoint: 0.000,  Lanes on structure: 1,  Lanes under structure: 8,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Length of Maximum Span: 30.1m (98.8ft)

Find on map >>   Show street view

Structure Number: 25 0127,  Location: 03-ED-050-R1.81L (Lat: 38.658278,  Lng: -121.054519),  Route carried "under" structure: US 50,  Year Built: 2015,  Structure Length: 0. m,  Average Daily Traffic: 72,000 (year 2009),  Truck Traffic: 6%,  Features Intersected: US 50,  Facility Carried by Structure: SILVA PARKWAY
Minimum Vertical Clearance: 5.63m (18.47ft),  Kilometerpoint: 1.810,  Lanes on structure: 6,  Lanes under structure: 7,  Material/Design: Prestressed concrete continuous,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 42.7m (140.1ft)

Discuss El Dorado Hills, California (CA) on our hugely popular California forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.