- Critical: Backflow Prevention
- Comment:
- CORRECTED. ICE MACHINE INSTALLED AND DRAIN LINE IS AIR GAPPED. BATCH FREEZER AND ELECTRO FREEZER DRAIN PIPES HAVE BEEN AIR GAPPED.
- General violation description:
- 5-402.11 - (A) Except as specified in (B) and (C) of this section, a direct connection may not exist between the SEWAGE system and a drain originating from EQUIPMENT in which FOOD, portable EQUIPMENT, or UTENSILS are placed. (B) If allowed by LAW, a WAREWASHING machine may have a direct connection between its waste outlet and a floor drain when the machine is located within 1.5 m (5 feet) of a trapped floor drain and the machine outlet is connected to the inlet side of a properly vented floor drain trap. (C) If allowed by LAW, a WAREWASHING or culinary sink may have a direct connection.
- Critical: Backflow Prevention Device, Wh
- Comment:
- CORRECTED BY PROVIDING BACKFLOW PROTECTION ON ICE MACHINE.
- General violation description:
- 5-203.14 - A PLUMBING SYSTEM shall be installed to preclude backflow of a solid, liquid, or gas contaminant into the water supply system at each point of use at the FOOD ESTABLISHMENT, including on a hose bibb if a hose is attached or on a hose bibb if a hose is not attached and backflow prevention is required by LAW, by: (A) Providing an air gap as specified under 5-202.13
- Critical: Hand Drying Provision
- Comment:
- CORRECTED BY PROVIDING PAPER TOWEL AT THE HANDWASH SINKS.
- General violation description:
- 6-301.12 - Each HANDWASHING SINK or group of adjacent HANDWASHING SINKS shall be provided with: (A) Individual, disposable towels
- Critical: Sanitizing Solutions, Testing
- Comment:
- CORRECTED BY PROVDING CHLORINE TEST STRIPS.
- General violation description:
- 4-302.14 - A test kit or other device that accurately measures the concentration in MG/L of SANITIZING solutions shall be provided. (Pf)
- Areas, Enclosures, and Recepta
- Comment:
- CORRECTED BY CLEANING ALL DEBRIS AROUND DUMPSTER.
- General violation description:
- 5-501.111 - Storage areas, enclosures, and receptacles for REFUSE, recyclables, and returnable's shall be maintained in good repair.
- Floors, Walls, and Ceilings
- Comment:
- CORRECTED BY INSTALLING THE CEILING TILES.
- General violation description:
- 6-201.11 - Except as specified under # 6-201.14 and except for antislip floor coverings or applications that may be used for safety reasons, floors, floor coverings, walls, wall coverings, and ceilings shall be designed, constructed, and installed so they are SMOOTH and EASILY CLEANABLE.
- Food-Contact Surfaces and Uten
- Comment:
- CORRECTED BY PROVIDING CHLORINE SANITIZER.
- General violation description:
- 4-701.10 - EQUIPMENT FOOD-CONTACT SURFACES and UTENSILS shall be SANITIZED.
- Handwashing Aids and Devices,
- Comment:
- CORRECTED BY REMOVING THE HAND SANITIZER DISPENSER.
- General violation description:
- 6-301.13 - A sink used for FOOD preparation or UTENSIL washing, or a service sink or curbed cleaning facility used for the disposal of mop water or similar wastes, may not be provided with the handwashing aids and devices required for a HANDWASHING SINK as specified under ## 6-301.11 and 6-301.12 and # 5-501.16(C).
- Outside Receptacles
- Comment:
- CORRECTED BY REPLACING DUMPSTER LIDS AND KEEPING THEM CLOSED.
- General violation description:
- 5-501.15 - (A) Receptacles and waste handling units for REFUSE, recyclables, and returnables used with materials containing FOOD residue and used outside the FOOD ESTABLISHMENT shall be designed and constructed to have tight-fitting lids, doors, or covers. (B) Receptacles and waste handling units for REFUSE and recyclables such as an on-site compactor shall be installed so that accumulation of debris and insect and rodent attraction and harborage are minimized and effective cleaning is facilitated around and, if the unit is not installed flush with the base pad, under the unit.
- System Maintained in Good Repa
- Comment:
- CORRECTED BY PROVIDING DRAIN PLUGS FOR 3-COMPARTMENT SINK.
- General violation description:
- 5-205.15 - A PLUMBING SYSTEM shall be: (A) Repaired according to LAW
- Toilet Rooms, Enclosed
- Comment:
- CORRECTED BY INSTALLING SELF-CLOSER ON THE RESTROOM DOOR.
- General violation description:
- 6-202.14 - Except where a toilet room is located outside a FOOD ESTABLISHMENT and does not open directly into the FOOD ESTABLISHMENT such as a toilet room that is provided by the management of a shopping mall, a toilet room located on the PREMISES shall be completely enclosed and provided with a tight-fitting and self-closing door.
|
06/20/2014 | Follow-up |
Restaurant representatives - add corrected or new information about La Gelati, 25442 Ford Road, Dearborn, MI 48128 »