- Critical: Backflow Prevention
- Comment:
- OBSERVED THAT THE DRAINLINES FROM FOODSERVICE EQUIPMENT HAS A SEPERATION FROM SEWAGE BY MEANS OF AN AIR GAP
- General violation description:
- 5-402.11 - ON THE WATERLINES FROM THE 3-COMPARTMENT SINK,SODA MACHINES AND THE HOT WELL. CORRECTED.
- Critical: Backflow Prevention Device, Wh
- Comment:
- OBSERVED THAT AN ASSE BACKFLOW PREVENTER -RPZ HAS BEEN INSTALLED ON THE WATERLINE TO THE CLEAN IN PLACE SHAKE MACHINE. COORECTED.
- General violation description:
- 5-203.14 - A PLUMBING SYSTEM shall be installed to preclude backflow of a solid, liquid, or gas contaminant into the water supply system at each point of use at the FOOD ESTABLISHMENT, including on a hose bibb if a hose is attached or on a hose bibb if a hose is not attached and backflow prevention is required by LAW, by: (A) Providing an air gap as specified under 5-202.13
- Contents of the Plans and Spec
- Comment:
- RECEIVED THAT SPECIFICATION INFORMATION ON THE SHAKE MACHINE AND THE COOLER. HOT WELL REMAINED THE SAME. CORRECTED.
- General violation description:
- 8-201.12 - The plans and specifications for a food establishment, including a food establishment specified under # 8-201.13, shall include, as required by the regulatory authority based on the type of operation, type of food preparation, and foods prepared, the following information to demonstrate conformance with Code provisions: (A) Intended menu
- Floor and Wall Junctures, Cove
- Comment:
- OBSERVED THAT A VINYL COVE HAS BEEN INSTALLED IN THE RESTROOM. CORRECTED.
- General violation description:
- 6-201.13 - (A) In FOOD ESTABLISHMENTS in which cleaning methods other than water flushing are used for cleaning floors, the floor and wall junctures shall be coved and closed to no larger than 1 mm (one thirty-second inch). (B) The floors in FOOD ESTABLISHMENTS in which water flush cleaning methods are used shall be provided with drains and be graded to drain, and the floor and wall junctures shall be coved and SEALED.
- Floors, Walls, and Ceilings
- Comment:
- OBSERVED THAT THE FLOOR INSTALLATION HAS BEEN COMPLETED AND IS NOW SEALED TO BE NON-ABSORBENT. CORRECTED.
- General violation description:
- 6-201.11 - Except as specified under # 6-201.14 and except for antislip floor coverings or applications that may be used for safety reasons, floors, floor coverings, walls, wall coverings, and ceilings shall be designed, constructed, and installed so they are SMOOTH and EASILY CLEANABLE.
- Good Repair and Proper Adjustm
- Comment:
- OBSERVED THAT THE WALK-IN COOLER PANELS HAVE BEEN SEALED TO REPAIR LEAK AND DRIPPAGE OVER FOOD STORAGE.CORRECTED. OBSERVED THAT THE DRAINLINE HAS BEEN DOUBLE CONTAINED ON THE INTERIOR OF THE ISLAND COOKLINE COOLER. CORRECTED.
- General violation description:
- 4-501.11 - (A) EQUIPMENT shall be maintained in a state of repair and condition that meets the requirements specified under Parts 4-1 and 4-2. (B) EQUIPMENT components such as doors, seals, hinges, fasteners, and kick plates shall be kept intact, tight, and adjusted in accordance with manufacturer's specifications. (C) Cutting or piercing parts of can openers shall be kept sharp to minimize the creation of metal fragments that can contaminate FOOD when the container is opened.
- Nonfood-Contact Surfaces
- Comment:
- OBSERVED THAT THE OPENINGS HAVE BEEN ELIMINATED
- General violation description:
- 4-202.16 - STAINLESS CHASE HAS BEEN CAPPED AND SEALED. AND THE OPENINGS AROUND THE SODA LINES HAVE BEEN SEALED.CORRECTED.
|