Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Wolverine, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 23Number of bridges
  • 151ft / 46.4mTotal length
  • $223,000Total costs
  • 57,514Total average daily traffic
  • 5,342Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Wolverine
  • No street view available for this location

New bridges in Wolverine, MI - historical statistics
  • New bridges - historical statistics
  • 11900-1909
  • 11940-1949
  • 11950-1959
  • 101960-1969
  • 41970-1979
  • 11980-1989
  • 21990-1999
  • 32000-2009
Reconstructed bridges in Wolverine, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11990-1999
  • 12000-2009
  • 22010-2019
Average Bridge Daily Traffic in Wolverine, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 5.9%Excellent
  • 23.5%Very good
  • 29.4%Good
  • 17.6%Satisfactory
  • 11.8%Fair
  • 11.8%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 41.2%Very good
  • 29.4%Good
  • 23.5%Satisfactory
  • 5.9%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 17.6%Very good
  • 29.4%Good
  • 35.3%Satisfactory
  • 5.9%Fair
  • 5.9%Poor
  • 5.9%Serious
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 38.5%Very good
  • 30.8%Good
  • 15.4%Satisfactory
  • 15.4%Fair
Find on map >>   Show street view

Structure Number: 156,  Location: 6.0 MI N OF WAYLAND (Lat: 42.764381,  Lng: -85.672975),  Route carried "on" structure: US 131,  Year Built: 1958,  Year Reconstructed: 2001,  Status: Open,  Structure Length: 5.63m (18.47ft),  Average Daily Traffic: 18,376 (year 2007),  Truck Traffic: 13%,  Average Future Daily Traffic: 23,284 (year 2018),  Design Load: HS 20,  Features Intersected: GRAND ELK RR
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 38.626,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 78,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 15.2m (49.9ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 20.1m (65.9ft),  Curb-To-Curb Width: 15.8m (51.8ft),  Out-to-Out Width: 16.9m (55.4ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Satisfactory,  Operating Rating: 62.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 5.64m (18.50ft),  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Bridge Improvement Cost: $924,000,  Roadway Improvement Cost: $13,000,  Total Project Cost: $148,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1521,  Location: 2.3 MI N OF OTSEGO COL (Lat: 45.226283,  Lng: -84.592767),  Route carried "on" structure: Interstate 75,  Year Built: 1962,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 7,777 (year 2018),  Truck Traffic: 6%,  Average Future Daily Traffic: 8,944 (year 2038),  Design Load: HS 20+Mod,  Features Intersected: STURGEON RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.850,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 55,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.5m (47.6ft),  Curb-To-Curb Width: 11.7m (38.4ft),  Out-to-Out Width: 13.3m (43.6ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 94.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 1523,  Location: 2.5 MI N OF OTSEGO COL (Lat: 45.229808,  Lng: -84.587664),  Route carried "on" structure: Interstate 75,  Year Built: 1962,  Year Reconstructed: 2007,  Status: Open,  Structure Length: 7.67m (25.16ft),  Average Daily Traffic: 5,338 (year 2007),  Truck Traffic: 12%,  Average Future Daily Traffic: 11,700 (year 2028),  Design Load: HS 20+Mod,  Features Intersected: TROWBRIDGE & D&MRR(ABN)
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 4.410,  Lanes on structure: 2,  Lanes under structure: 2,  Base Highway Network: Yes (Inventory Route: 55,  Subroute: 7),  Owner: State Highway Agency,  Approaching Roadway Width: 13.7m (44.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 20.7m (67.9ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 10.9m (35.8ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Satisfactory,  Operating Rating: 75.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 45.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay
Find on map >>   Show street view

Structure Number: 1527,  Location: 6.2 MI S OF M-68 (Lat: 45.316686,  Lng: -84.596319),  Route carried "on" structure: County highway 1622,  Year Built: 1962,  Status: Open,  Structure Length: 6.64m (21.78ft),  Average Daily Traffic: 230 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 400 (year 2007),  Design Load: H 15,  Features Intersected: I-75 SB,  Facility Carried by Structure: RONDO RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.375,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.0m (32.8ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.2m (72.8ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Fair,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 67.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1528,  Location: 6.2 MI S OF M-68 (Lat: 45.316658,  Lng: -84.595153),  Route carried "on" structure: County highway 1622,  Year Built: 1962,  Status: Open,  Structure Length: 6.64m (21.78ft),  Average Daily Traffic: 230 (year 1997),  Truck Traffic: 3%,  Average Future Daily Traffic: 400 (year 2007),  Design Load: H 15,  Features Intersected: I-75 NB,  Facility Carried by Structure: RONDO RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.466,  Lanes on structure: 2,  Lanes under structure: 2,  Owner: State Highway Agency,  Approaching Roadway Width: 10.0m (32.8ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 22.2m (72.8ft),  Curb or Sidewalk Widths: Left: 0.7m (2.3ft),  Right: 0.7m (2.3ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Fair,  Operating Rating: 67.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 40.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: High priority of corrective action,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1532,  Location: IN SEC 14 T33NR3W (Lat: 45.255217,  Lng: -84.632650),  Route carried "on" structure: County highway 1619,  Year Built: 1991,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 1,260 (year 2005),  Average Future Daily Traffic: 2,300 (year 2025),  Design Load: HL 93,  Features Intersected: STURGEON RIVER,  Facility Carried by Structure: OLD 27
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.919,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 13.1m (43.0ft),  Curb-To-Curb Width: 12.5m (41.0ft),  Out-to-Out Width: 13.2m (43.3ft)

Condition: Deck: Poor,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 73.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 55.7 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1539,  Location: SEC 29 T33NR2W (Lat: 45.222292,  Lng: -84.588150),  Route carried "on" structure: County highway 1631,  Year Built: 1977,  Status: Posted for load,  Structure Length: 1.34m (4.40ft),  Average Daily Traffic: 400 (year 2005),  Average Future Daily Traffic: 730 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: STURGEON RIVER,  Facility Carried by Structure: TROWBRIDGE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.810,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 37.6 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 28.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 154,  Location: SEC 20 T33NR2W (Lat: 45.232022,  Lng: -84.588486),  Route carried "on" structure: County highway 1631,  Year Built: 1977,  Status: Posted for load,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 410 (year 2005),  Average Future Daily Traffic: 730 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: STURGEON RIVER,  Facility Carried by Structure: TROWBRIDGE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 6.912,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 39.5 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 1541,  Location: BETWEEN SEC. 24&25 T34R3W (Lat: 45.316808,  Lng: -84.622383),  Route carried "on" structure: County highway 1622,  Year Built: 1979,  Status: Open,  Structure Length: 2.37m (7.78ft),  Average Daily Traffic: 640 (year 2005),  Average Future Daily Traffic: 1,100 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: STURGEON RIVER,  Facility Carried by Structure: RONDO ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.187,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.8m (32.2ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 23.7m (77.8ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.2m (30.2ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Good,  Operating Rating: 66.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1544,  Location: SEC.31,T34N,R2W (Lat: 45.291361,  Lng: -84.605517),  Route carried "on" structure: County highway ,  Year Built: 2003,  Status: Posted for load,  Structure Length: 2.26m (7.41ft),  Average Daily Traffic: 220 (year 2005),  Average Future Daily Traffic: 400 (year 2025),  Design Load: HS 20,  Features Intersected: STURGEON RIVER,  Facility Carried by Structure: SCOTT ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.288,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 21.6m (70.9ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.5m (34.4ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 58.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1549,  Location: SEC 20 T33N R2W (Lat: 45.236633,  Lng: -84.586078),  Route carried "on" structure: County highway ,  Year Built: 1978,  Year Reconstructed: 2010,  Status: Posted for load,  Structure Length: 1.07m (3.51ft),  Average Daily Traffic: 30 (year 2005),  Average Future Daily Traffic: 50 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: STURGEON RIVER,  Facility Carried by Structure: FREEWAY TRAIL
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.332,  Lanes on structure: 1,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 10.4m (34.1ft),  Curb-To-Curb Width: 3.5m (11.5ft),  Out-to-Out Width: 3.7m (12.1ft)

Condition: Deck: Excellent,  Superstructure: Very good,  Substructure: Serious,  Channel: Fair,  Operating Rating: 39.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 23.7 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Length Of Structure Improvement: 1.00m (3.28ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: July 2021,  Bridge Improvement Cost: $60,000,  Roadway Improvement Cost: $15,000,  Total Project Cost: $75,000,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 1556,  Location: WILMOT TWP SEC 16 (Lat: 45.248908,  Lng: -84.676617),  Route carried "on" structure: County highway ,  Year Built: 2008,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 180 (year 2007),  Average Future Daily Traffic: 325 (year 2027),  Design Load: HS 20+Mod,  Features Intersected: W BR STURGEON RIVER,  Facility Carried by Structure: MC EACHRON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.579,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.0m (45.9ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 41.5 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Somewhat better than minimum adequacy,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1557,  Location: SEC.14/15,T33N,R3W (Lat: 45.249375,  Lng: -84.651972),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 1.82m (5.97ft),  Average Daily Traffic: 240 (year 2005),  Average Future Daily Traffic: 430 (year 2025),  Design Load: HS 20,  Features Intersected: W BR STURGEON RIVER,  Facility Carried by Structure: OLD STURGEON RD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.989,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.0m (55.8ft),  Curb-To-Curb Width: 9.8m (32.2ft),  Out-to-Out Width: 10.4m (34.1ft)

Condition: Deck: Satisfactory,  Superstructure: Very good,  Substructure: Good,  Channel: Good,  Operating Rating: 39.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1558,  Location: SEC.12,T33N,R3W (Lat: 45.260481,  Lng: -84.620803),  Route carried "on" structure: County highway ,  Year Built: 2005,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 144 (year 2005),  Average Future Daily Traffic: 260 (year 2025),  Design Load: HS 20+Mod,  Features Intersected: W BR STURGEON RIVER,  Facility Carried by Structure: SHIRE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 9.682,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 10.0m (32.8ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 68.4 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 52.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 156,  Location: IN WOLVERINE (Lat: 45.271192,  Lng: -84.602536),  Route carried "on" structure: City street 653,  Year Built: 1949,  Status: Open,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 520 (year 2017),  Average Future Daily Traffic: 650 (year 2037),  Design Load: HS 20+Mod,  Features Intersected: W BR STURGEON RIVER,  Facility Carried by Structure: TROWBRIDGE ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.491,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.8m (28.9ft),  Curb or Sidewalk Widths: Left: 0.6m (2.0ft),  Right: 0.6m (2.0ft),  Curb-To-Curb Width: 6.7m (22.0ft),  Out-to-Out Width: 8.5m (27.9ft)

Condition: Deck: Fair,  Superstructure: Poor,  Substructure: Good,  Channel: Very good,  Operating Rating: 50.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 30.5 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 1561,  Location: IN WOLVERINE (Lat: 45.273153,  Lng: -84.600608),  Route carried "on" structure: City street 1641,  Year Built: 1987,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 800 (year 2017),  Average Future Daily Traffic: 1,100 (year 2037),  Design Load: HS 20+Mod,  Features Intersected: STURGEON RIVER,  Facility Carried by Structure: EAST MAIN STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.295,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 13.7m (44.9ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 72.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 43.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 1562,  Location: VILLAGE OF WOLVERINE (Lat: 45.274967,  Lng: -84.600036),  Route carried "on" structure: County highway ,  Year Built: 1900,  Year Reconstructed: 2019,  Status: Posted for load,  Structure Length: 1.58m (5.18ft),  Average Daily Traffic: 25 (year 2015),  Average Future Daily Traffic: 30 (year 2035),  Design Load: HL 93,  Features Intersected: STURGEON RIVER,  Facility Carried by Structure: NEW NATURE AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.533,  Lanes on structure: 1,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 3.7m (12.1ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 4.2m (13.8ft),  Curb-To-Curb Width: 3.3m (10.8ft),  Out-to-Out Width: 3.7m (12.1ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Poor,  Channel: Fair,  Operating Rating: 24.9 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 19.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of replacement,  Waterway Adequacy: Meets minimum limits,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Wood or Timber
Find on map >>   Show street view

Structure Number: 1523,  Location: 2.5 MI N OF OTSEGO COL (Lat: 45.229808,  Lng: -84.587664),  Route carried "under" structure: County highway 1631,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 200 (year 1997),  Truck Traffic: 3%,  Features Intersected: TROWBRIDGE & D&MRR(ABN),  Facility Carried by Structure: I-75 SB
Minimum Vertical Clearance: 6.12m (20.08ft),  Kilometerpoint: 6.658,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.7m (67.9ft)

Find on map >>   Show street view

Structure Number: 1524,  Location: 2.5 MI N OF OTSEGO COL (Lat: 45.229364,  Lng: -84.587486),  Route carried "under" structure: County highway 1631,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 200 (year 1997),  Truck Traffic: 3%,  Features Intersected: TROWBRIDGE & D&MRR(ABN),  Facility Carried by Structure: I-75 NB
Minimum Vertical Clearance: 6.12m (20.08ft),  Kilometerpoint: 6.607,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 20.7m (67.9ft)

Find on map >>   Show street view

Structure Number: 1525,  Location: 5.8 MI N OF OTSEGO COL (Lat: 45.273178,  Lng: -84.592539),  Route carried "under" structure: Interstate 75,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 5,338 (year 2007),  Truck Traffic: 9%,  Features Intersected: I-75 SB,  Facility Carried by Structure: WEBB RD
Minimum Vertical Clearance: 5.03m (16.50ft),  Kilometerpoint: 9.597,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.6m (57.7ft)

Find on map >>   Show street view

Structure Number: 1526,  Location: 5.8 MI N OF OTSEGO COL (Lat: 45.273161,  Lng: -84.591592),  Route carried "under" structure: Interstate 75,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 5,338 (year 2007),  Truck Traffic: 9%,  Features Intersected: I-75 NB,  Facility Carried by Structure: WEBB RD
Minimum Vertical Clearance: 5.00m (16.40ft),  Kilometerpoint: 9.500,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.6m (57.7ft)

Find on map >>   Show street view

Structure Number: 1527,  Location: 6.2 MI S OF M-68 (Lat: 45.316686,  Lng: -84.596319),  Route carried "under" structure: Interstate 75,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 4,809 (year 2007),  Truck Traffic: 9%,  Features Intersected: I-75 SB,  Facility Carried by Structure: RONDO RD
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 14.565,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.2m (72.8ft)

Find on map >>   Show street view

Structure Number: 1528,  Location: 6.2 MI S OF M-68 (Lat: 45.316658,  Lng: -84.595153),  Route carried "under" structure: Interstate 75,  Year Built: 1962,  Structure Length: 0. m,  Average Daily Traffic: 4,809 (year 2007),  Truck Traffic: 9%,  Features Intersected: I-75 NB,  Facility Carried by Structure: RONDO RD
Minimum Vertical Clearance: 5.08m (16.67ft),  Kilometerpoint: 14.462,  Lanes on structure: 2,  Lanes under structure: 2,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 22.2m (72.8ft)

Discuss Wolverine, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.