Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for White Pigeon, Michigan (MI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 12Number of bridges
  • 108ft / 32.8mTotal length
  • 62,890Total average daily traffic
  • 3,557Total average daily truck traffic
  • 107,184Total future (year 2010) average daily traffic
  • National Bridge Inventory (NBI) Registered Bridges for White Pigeon
  • No street view available for this location

New bridges in White Pigeon, MI - historical statistics
  • New bridges - historical statistics
  • 21930-1939
  • 11950-1959
  • 21970-1979
  • 51980-1989
  • 11990-1999
  • 12010-2019
Reconstructed bridges in White Pigeon, MI - Historical Statistics
  • Reconstructed bridges - Historical Statistics
  • 11960-1969
  • 01970-1979
  • 01980-1989
  • 11990-1999
Average Bridge Daily Traffic in White Pigeon, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 18.2%Very good
  • 27.3%Good
  • 36.4%Satisfactory
  • 18.2%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 18.2%Very good
  • 9.1%Good
  • 45.5%Satisfactory
  • 9.1%Fair
  • 9.1%Poor
  • 9.1%Serious
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 9.1%Very good
  • 45.5%Good
  • 45.5%Satisfactory
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 8.3%Very good
  • 8.3%Good
  • 25.0%Satisfactory
  • 50.0%Fair
  • 8.3%Poor
Find on map >>   Show street view

Structure Number: 6784,  Location: CITY OF BIG RAPIDS (Lat: 43.708908,  Lng: -85.481192),  Route carried "on" structure: City street ,  Year Built: 2016,  Status: Open,  Structure Length: 7.01m (23.00ft),  Average Daily Traffic: 7,400 (year 2015),  Truck Traffic: 5%,  Average Future Daily Traffic: 13,000 (year 2035),  Design Load: Greater than HL93,  Features Intersected: MUSKEGON RIVER,  Facility Carried by Structure: BALDWIN STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.014,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 31.5m (103.3ft),  Curb or Sidewalk Widths: Left: 2.0m (6.6ft),  Right: 2.0m (6.6ft),  Curb-To-Curb Width: 11.0m (36.1ft),  Out-to-Out Width: 15.9m (52.2ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 47.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 42.8 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7012,  Location: IN CITY OF MIDLAND (Lat: 43.641264,  Lng: -84.272697),  Route carried "on" structure: City street 2015,  Year Built: 1931,  Year Reconstructed: 1968,  Status: Open,  Structure Length: 0.61m (2.00ft),  Average Daily Traffic: 17,000 (year 1990),  Truck Traffic: 3%,  Average Future Daily Traffic: 19,550 (year 2010),  Design Load: HS 20+Mod,  Features Intersected: STATE DRAIN,  Facility Carried by Structure: N SAGINAW ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 30.670,  Lanes on structure: 2,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Concrete,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.1m (20.0ft),  Curb or Sidewalk Widths: Left: 1.5m (4.9ft),  Right: 0.0m

Condition: Channel: Poor,  Culverts: Satisfactory,  Operating Rating: 55.0 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 33.0 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 7013,  Location: IN CITY OF MIDLAND (Lat: 43.641286,  Lng: -84.266272),  Route carried "on" structure: City street 2015,  Year Built: 1931,  Year Reconstructed: 1990,  Status: Open,  Structure Length: 1.52m (4.99ft),  Average Daily Traffic: 20,000 (year 1985),  Truck Traffic: 3%,  Average Future Daily Traffic: 50,000 (year 2016),  Design Load: HS 20,  Features Intersected: STURGEON CREEK,  Facility Carried by Structure: N SAGINAW ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 31.189,  Lanes on structure: 4,  Owner: City or Municipal Highway Agency,  Approaching Roadway Width: 13.4m (44.0ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.6m (47.9ft),  Curb or Sidewalk Widths: Left: 2.4m (7.9ft),  Right: 1.5m (4.9ft),  Curb-To-Curb Width: 20.7m (67.9ft),  Out-to-Out Width: 25.9m (85.0ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 70.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 41.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 7313,  Location: 0.55 MI N OF READY ROAD (Lat: 42.058339,  Lng: -83.346331),  Route carried "on" structure: County highway ,  Year Built: 1982,  Status: Posted for load,  Structure Length: 3.47m (11.38ft),  Average Daily Traffic: 220 (year 2008),  Truck Traffic: 14%,  Average Future Daily Traffic: 253 (year 2028),  Design Load: HS 20,  Features Intersected: SWAN CREEK,  Facility Carried by Structure: SWEITZER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.113,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 10.9m (35.8ft),  Curb-To-Curb Width: 9.4m (30.8ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Poor,  Superstructure: Serious,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 30.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 18.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Other
Find on map >>   Show street view

Structure Number: 7483,  Location: 0.25 MI N OF CO 544 (Lat: 43.434694,  Lng: -85.126694),  Route carried "on" structure: County highway ,  Year Built: 1978,  Status: Posted for load,  Structure Length: 0.97m (3.18ft),  Average Daily Traffic: 577 (year 2003),  Truck Traffic: 5%,  Average Future Daily Traffic: 753 (year 2023),  Design Load: HS 20+Mod,  Features Intersected: FLAT RIVER,  Facility Carried by Structure: MUSSON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.794,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.1m (29.9ft),  Curb-To-Curb Width: 7.6m (24.9ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 35.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 24.0 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 30.0 - 39.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 7507,  Location: STATION 0.02 W DERBY RD (Lat: 43.185103,  Lng: -85.134003),  Route carried "on" structure: County highway ,  Year Built: 1985,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 107 (year 2003),  Average Future Daily Traffic: 145 (year 2023),  Design Load: HS 20+Mod,  Features Intersected: DICKERSON CREEK,  Facility Carried by Structure: STATION ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.901,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.3m (24.0ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 7.0m (23.0ft),  Curb-To-Curb Width: 7.3m (24.0ft),  Out-to-Out Width: 7.8m (25.6ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Fair,  Operating Rating: 51.1 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS),  Inventory Rating: 35.7 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Gravel
Find on map >>   Show street view

Structure Number: 10268,  Location: 4.4 MI E OF US-131 (Lat: 41.796456,  Lng: -85.582342),  Route carried "on" structure: US 12,  Year Built: 1983,  Status: Open,  Structure Length: 3.35m (10.99ft),  Average Daily Traffic: 5,925 (year 2007),  Truck Traffic: 8%,  Average Future Daily Traffic: 8,200 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: FAWN RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 14.969,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 23,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 13.1m (43.0ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 33.5m (109.9ft),  Curb-To-Curb Width: 14.6m (47.9ft),  Out-to-Out Width: 15.6m (51.2ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Fair,  Operating Rating: 70.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.4 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: July 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10269,  Location: 2.4 MI N OF INDIANA STATE (Lat: 41.790461,  Lng: -85.662586),  Route carried "on" structure: US 131,  Year Built: 1994,  Status: Open,  Structure Length: 3.41m (11.19ft),  Average Daily Traffic: 9,556 (year 2007),  Truck Traffic: 15%,  Average Future Daily Traffic: 12,276 (year 2018),  Design Load: HS 25 or greater,  Features Intersected: WHITE PIGEON RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 3.898,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 23,  Subroute: 1),  Owner: State Highway Agency,  Approaching Roadway Width: 12.8m (42.0ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 17.0m (55.8ft),  Curb-To-Curb Width: 15.9m (52.2ft),  Out-to-Out Width: 16.8m (55.1ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Fair,  Operating Rating: 82.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 47.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Underwater Inspection Frequency: Every 60 months,  Inspection Date: September 2021,  Underwater Inspection Date: August 2017,  Bridge Improvement Cost: $222,000,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 10288,  Location: 3.5 MI SE OF WHITE PIGEON (Lat: 41.780511,  Lng: -85.583050),  Route carried "on" structure: County highway 7812,  Year Built: 1954,  Status: Open,  Structure Length: 2.43m (7.97ft),  Average Daily Traffic: 1,011 (year 2003),  Truck Traffic: 5%,  Average Future Daily Traffic: 1,443 (year 2023),  Design Load: H 20,  Features Intersected: FAWN RIVER,  Facility Carried by Structure: FAWN RIVER ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 1.712,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 12.2m (40.0ft),  Curb or Sidewalk Widths: Left: 0.4m (1.3ft),  Right: 0.4m (1.3ft),  Curb-To-Curb Width: 7.0m (23.0ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 53.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 32.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10328,  Location: 3 MI S OF CONSTANTINE (Lat: 41.790114,  Lng: -85.681625),  Route carried "on" structure: County highway ,  Year Built: 1978,  Status: Posted for load,  Structure Length: 2.92m (9.58ft),  Average Daily Traffic: 282 (year 2003),  Truck Traffic: 8%,  Average Future Daily Traffic: 401 (year 2023),  Design Load: H 20,  Features Intersected: WHITE PIGEON RIVER,  Facility Carried by Structure: BLUE SCHOOL ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.966,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Skew: 1 degrees,  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.8m (32.2ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 33.0 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 22.4 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Meets minimum limits,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 20.0 - 29.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: November 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 10329,  Location: 3 MI E OF WHITE PIGEON (Lat: 41.809658,  Lng: -85.578411),  Route carried "on" structure: County highway ,  Year Built: 1987,  Status: Posted for load,  Structure Length: 2.92m (9.58ft),  Average Daily Traffic: 381 (year 2003),  Truck Traffic: 5%,  Average Future Daily Traffic: 543 (year 2023),  Design Load: HS 20,  Features Intersected: FAWN RIVER,  Facility Carried by Structure: DICKINSON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.518,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.1m (33.1ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 7.3m (24.0ft),  Curb-To-Curb Width: 10.1m (33.1ft),  Out-to-Out Width: 10.3m (33.8ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 42.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.8 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: 0.1 - 9.9% below),  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 1033,  Location: 2 MI SE OF WHITE PIGEON (Lat: 41.773572,  Lng: -85.603556),  Route carried "on" structure: County highway ,  Year Built: 1984,  Status: Open,  Structure Length: 3.53m (11.58ft),  Average Daily Traffic: 431 (year 2003),  Truck Traffic: 5%,  Average Future Daily Traffic: 620 (year 2023),  Design Load: HS 20,  Features Intersected: WHITE PIGEON RIVER,  Facility Carried by Structure: SEVISON ROAD
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 2.554,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 17.6m (57.7ft),  Curb-To-Curb Width: 9.1m (29.9ft),  Out-to-Out Width: 9.4m (30.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Channel: Good,  Operating Rating: 58.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: November 2021,  Deck Structure Type: Other,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Discuss White Pigeon, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.