  • 18Number of bridges
  • 121ft / 36.5mTotal length
  • 255,467Total average daily traffic
  • 32,588Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Wayland
  • No street view available for this location

New bridges in Wayland, MI - historical statistics
  • New bridges - historical statistics
  • 11930-1939
  • 11940-1949
  • 71950-1959
  • 31970-1979
  • 11980-1989
  • 21990-1999
  • 12000-2009
  • 22010-2019
Average Bridge Daily Traffic in Wayland, MI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 9.1%Very good
  • 27.3%Good
  • 45.5%Satisfactory
  • 9.1%Fair
  • 9.1%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 18.2%Very good
  • 18.2%Good
  • 18.2%Satisfactory
  • 36.4%Fair
  • 9.1%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 9.1%Very good
  • 45.5%Good
  • 27.3%Satisfactory
  • 18.2%Fair
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 75.0%Satisfactory
  • 12.5%Fair
  • 12.5%Serious
Bridge Condition - Culverts
  • Bridge Condition - Culverts
  • 50.0%Poor
  • 50.0%Serious
Find on map >>   Show street view

Structure Number: 153,  Location: 0.3 MI N OF WAYLAND (Lat: 42.683728,  Lng: -85.660469),  Route carried "on" structure: US 131,  Year Built: 1957,  Status: Open,  Structure Length: 1.70m (5.58ft),  Average Daily Traffic: 15,300 (year 2009),  Truck Traffic: 10%,  Average Future Daily Traffic: 24,415 (year 2018),  Design Load: HS 20,  Features Intersected: RABBIT RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 29.397,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 78,  Subroute: 6),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.0m (55.8ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 83.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 154,  Location: 0.3 MI N OF WAYLAND (Lat: 42.683639,  Lng: -85.660717),  Route carried "on" structure: US 131,  Year Built: 1957,  Status: Open,  Structure Length: 1.70m (5.58ft),  Average Daily Traffic: 18,817 (year 2007),  Truck Traffic: 14%,  Average Future Daily Traffic: 24,415 (year 2018),  Design Load: HS 20,  Features Intersected: RABBIT RIVER
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 29.388,  Lanes on structure: 2,  Base Highway Network: Yes (Inventory Route: 78,  Subroute: 5),  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 13 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 17.0m (55.8ft),  Curb-To-Curb Width: 12.8m (42.0ft),  Out-to-Out Width: 14.4m (47.2ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 83.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 49.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Equal to present desirable criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Latex Concrete
Find on map >>   Show street view

Structure Number: 161,  Location: 6.0 MI N OF M-222 (Lat: 42.630378,  Lng: -85.662156),  Route carried "on" structure: State highway 179,  Year Built: 1959,  Status: Open,  Structure Length: 5.65m (18.54ft),  Average Daily Traffic: 4,627 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 6,476 (year 2018),  Design Load: HS 20,  Features Intersected: US-131
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.866,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.8m (28.9ft),  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 17.9m (58.7ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Fair,  Operating Rating: 59.9 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 36.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Deck Geometry: High priority of corrective action,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 12 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 162,  Location: AT W LTS OF WAYLAND (Lat: 42.674089,  Lng: -85.661103),  Route carried "on" structure: County highway 366,  Year Built: 1999,  Status: Open,  Structure Length: 5.40m (17.72ft),  Average Daily Traffic: 18,355 (year 1999),  Truck Traffic: 13%,  Average Future Daily Traffic: 21,100 (year 2020),  Design Load: HS 25 or greater,  Features Intersected: US-131,  Facility Carried by Structure: 135TH AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 10.628,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.3m (33.8ft),  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 27.0m (88.6ft),  Curb-To-Curb Width: 18.1m (59.4ft),  Out-to-Out Width: 19.1m (62.7ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Good,  Operating Rating: 75.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 42.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Superior to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 163,  Location: 2.0 MI N OF WAYLAND (Lat: 42.710211,  Lng: -85.661242),  Route carried "on" structure: County highway ,  Year Built: 1957,  Status: Open,  Structure Length: 5.72m (18.77ft),  Average Daily Traffic: 209 (year 1986),  Truck Traffic: 2%,  Average Future Daily Traffic: 240 (year 2006),  Design Load: H 15,  Features Intersected: US-131,  Facility Carried by Structure: 140TH AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 7.410,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 8.5m (27.9ft),  Skew: 2 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 4,  Length of Maximum Span: 18.1m (59.4ft),  Curb or Sidewalk Widths: Left: 0.2m (0.7ft),  Right: 0.2m (0.7ft),  Curb-To-Curb Width: 7.9m (25.9ft),  Out-to-Out Width: 10.2m (33.5ft)

Condition: Deck: Fair,  Superstructure: Fair,  Substructure: Fair,  Operating Rating: 54.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 29.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: 164,  Location: 3.0 MI N OF WAYLAND (Lat: 42.724778,  Lng: -85.672131),  Route carried "on" structure: County highway 382,  Year Built: 2011,  Status: Open,  Structure Length: 5.18m (16.99ft),  Average Daily Traffic: 10,163 (year 1997),  Truck Traffic: 2%,  Average Future Daily Traffic: 8,550 (year 2030),  Design Load: HL 93,  Features Intersected: US-131,  Facility Carried by Structure: 142ND AVE
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 26.677,  Lanes on structure: 3,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 15.8m (51.8ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 25.9m (85.0ft),  Curb-To-Curb Width: 15.5m (50.9ft),  Out-to-Out Width: 16.4m (53.8ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Good,  Operating Rating: 94.3 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 72.9 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Superior to present desirable criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: June 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Integral Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 21,  Location: WAYLAND TWP SEC 29-30 (Lat: 42.610000,  Lng: -85.642244),  Route carried "on" structure: County highway 385,  Year Built: 1939,  Year Reconstructed: 2006,  Status: Open,  Structure Length: 4.59m (15.06ft),  Average Daily Traffic: 2,222 (year 2016),  Truck Traffic: 7%,  Average Future Daily Traffic: 3,270 (year 2036),  Design Load: HS 25 or greater,  Features Intersected: CONSOLIDATED RAIL CORP,  Facility Carried by Structure: 10TH STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 21.386,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 16.6m (54.5ft),  Curb-To-Curb Width: 12.6m (41.3ft),  Out-to-Out Width: 13.4m (44.0ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 81.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: September 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Epoxy Overlay,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 211,  Location: APPROX 3/8 MI SE OF 137TH (Lat: 42.686008,  Lng: -85.645947),  Route carried "on" structure: County highway 385,  Year Built: 1940,  Status: Open,  Structure Length: 1.00m (3.28ft),  Average Daily Traffic: 3,443 (year 2013),  Truck Traffic: 7%,  Average Future Daily Traffic: 3,615 (year 2033),  Design Load: HS 20+Mod,  Features Intersected: RABBIT RIVER,  Facility Carried by Structure: DIVISION STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.425,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 10.7m (35.1ft),  Skew: 4 degrees,  Material/Design: Concrete,  Design/Construction: Tee Beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.7m (31.8ft),  Curb-To-Curb Width: 10.7m (35.1ft),  Out-to-Out Width: 11.7m (38.4ft)

Condition: Deck: Satisfactory,  Superstructure: Fair,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 51.3 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 30.7 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Better than present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 23,  Location: APPROX 0.15 MI W OF 12TH (Lat: 42.681153,  Lng: -85.664503),  Route carried "on" structure: County highway ,  Year Built: 1971,  Status: Open,  Structure Length: 1.22m (4.00ft),  Average Daily Traffic: 112 (year 2002),  Truck Traffic: 7%,  Average Future Daily Traffic: 224 (year 2022),  Design Load: HS 20+Mod,  Features Intersected: RABBIT RIVER,  Facility Carried by Structure: 136TH AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 6.290,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Material/Design: Wood or Timber,  Design/Construction: Slab,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 6.1m (20.0ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.9m (29.2ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Fair,  Operating Rating: 53.8 metric tons,  Method Used To Determine Operating Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 38.6 metric tons,  Method Used To Determine Inventory Rating: Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Wood or Timber,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: 24,  Location: APPROX 1/8MI N OF 140TH A (Lat: 42.712061,  Lng: -85.702036),  Route carried "on" structure: County highway ,  Year Built: 1974,  Status: Posted for load,  Structure Length: 0.94m (3.08ft),  Average Daily Traffic: 436 (year 2002),  Truck Traffic: 7%,  Average Future Daily Traffic: 872 (year 2022),  Design Load: H 20,  Features Intersected: RED RUN DRAIN,  Facility Carried by Structure: 16TH STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 11.456,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 7.6m (24.9ft),  Skew: 4 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.9m (12.8ft)

Condition: Channel: Serious,  Culverts: Serious,  Operating Rating: 22.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 13.6 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: High priority of corrective action,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Bridge Posting: Required (Relationship of Operating Rating to Maximum Legal Load: > 39.9% below),  Designated Inspection Frequency: Every 12 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 261,  Location: HOPKINS TWP SEC 10-11 (Lat: 42.656253,  Lng: -85.702336),  Route carried "on" structure: County highway ,  Year Built: 1982,  Status: Open,  Structure Length: 1.43m (4.69ft),  Average Daily Traffic: 120 (year 2015),  Truck Traffic: 7%,  Average Future Daily Traffic: 178 (year 2035),  Design Load: HS 20+Mod,  Features Intersected: RABBIT RIVER,  Facility Carried by Structure: 16TH STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 5.221,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 14.3m (46.9ft),  Curb-To-Curb Width: 8.9m (29.2ft),  Out-to-Out Width: 9.3m (30.5ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Good,  Channel: Satisfactory,  Operating Rating: 58.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 35.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Better than present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: May 2021,  Deck Structure Type: Concrete Precast Panels,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Membrane: Preformed Fabric
Find on map >>   Show street view

Structure Number: 273,  Location: LEIGHTON TWP SEC 31-32 (Lat: 42.685681,  Lng: -85.643586),  Route carried "on" structure: County highway ,  Year Built: 2009,  Status: Open,  Structure Length: 1.37m (4.49ft),  Average Daily Traffic: 1,271 (year 2007),  Truck Traffic: 5%,  Average Future Daily Traffic: 2,091 (year 2028),  Features Intersected: RABBIT RIVER DRAIN,  Facility Carried by Structure: 10TH STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 29.827,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 1 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Single/Spread,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 12.5m (41.0ft),  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 13.1m (43.0ft)

Condition: Deck: Good,  Superstructure: Very good,  Substructure: Very good,  Channel: Satisfactory,  Operating Rating: 97.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 70.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: 312,  Location: APPROX 3/8MI S OF 135TH A (Lat: 42.668650,  Lng: -85.613700),  Route carried "on" structure: County highway ,  Year Built: 1971,  Status: Posted for load,  Structure Length: 0.64m (2.10ft),  Average Daily Traffic: 300 (year 2002),  Truck Traffic: 7%,  Average Future Daily Traffic: 600 (year 2002),  Design Load: H 20,  Features Intersected: RABBIT RIVER,  Facility Carried by Structure: 7TH STREET
Minimum Vertical Clearance: 30.48m (100.00ft),  Kilometerpoint: 0.636,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 9.1m (29.9ft),  Skew: 1 degrees,  Material/Design: Steel,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 2.4m (7.9ft)

Condition: Channel: Satisfactory,  Culverts: Poor,  Operating Rating: 23.3 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Inventory Rating: 13.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF) rating reported by rating factor (RF) method using MS18 loading,  Structural Evaluation: Meets minimum limits,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: April 2021
Find on map >>   Show street view

Structure Number: 161,  Location: 6.0 MI N OF M-222 (Lat: 42.630378,  Lng: -85.662156),  Route carried "under" structure: US 131,  Year Built: 1959,  Structure Length: 0. m,  Average Daily Traffic: 30,438 (year 2007),  Truck Traffic: 16%,  Features Intersected: US-131,  Facility Carried by Structure: M-179 (129TH AVE)
Minimum Vertical Clearance: 4.62m (15.16ft),  Kilometerpoint: 23.468,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 17.9m (58.7ft)

Find on map >>   Show street view

Structure Number: 162,  Location: AT W LTS OF WAYLAND (Lat: 42.674089,  Lng: -85.661103),  Route carried "under" structure: US 131,  Year Built: 1999,  Structure Length: 0. m,  Average Daily Traffic: 37,634 (year 2007),  Truck Traffic: 14%,  Features Intersected: US-131,  Facility Carried by Structure: 135TH AVE
Minimum Vertical Clearance: 4.98m (16.34ft),  Kilometerpoint: 28.325,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 27.0m (88.6ft)

Find on map >>   Show street view

Structure Number: 163,  Location: 2.0 MI N OF WAYLAND (Lat: 42.710211,  Lng: -85.661242),  Route carried "under" structure: US 131,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 37,634 (year 2007),  Truck Traffic: 14%,  Features Intersected: US-131,  Facility Carried by Structure: 140TH AVE
Minimum Vertical Clearance: 4.82m (15.81ft),  Kilometerpoint: 32.363,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 18.1m (59.4ft)

Find on map >>   Show street view

Structure Number: 164,  Location: 3.0 MI N OF WAYLAND (Lat: 42.724778,  Lng: -85.672131),  Route carried "under" structure: US 131,  Year Built: 2011,  Structure Length: 0. m,  Average Daily Traffic: 37,634 (year 2007),  Truck Traffic: 13%,  Features Intersected: US-131,  Facility Carried by Structure: 142ND AVE
Minimum Vertical Clearance: 6.17m (20.24ft),  Kilometerpoint: 34.214,  Lanes on structure: 3,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Box Beam or Girders - Multiple,  Length of Maximum Span: 25.9m (85.0ft)

Find on map >>   Show street view

Structure Number: 165,  Location: 4.1 MI N OF WAYLAND (Lat: 42.739336,  Lng: -85.673183),  Route carried "under" structure: US 131,  Year Built: 1957,  Structure Length: 0. m,  Average Daily Traffic: 36,752 (year 2007),  Truck Traffic: 13%,  Features Intersected: US-131,  Facility Carried by Structure: 144TH AVE
Minimum Vertical Clearance: 4.55m (14.93ft),  Kilometerpoint: 35.840,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 16.3m (53.5ft)

Discuss Wayland, Michigan (MI) on our hugely popular Michigan forum.


City-data.com does not guarantee the accuracy or timeliness of any information on this site.  Use at your own risk.
Some parts © 2024 Advameg, Inc.