Jump to a detailed profile or search site with Google Custom Search

Bridge Statistics for Vinland, Wisconsin (WI)
Condition, Traffic, Stress, Structural Evaluation, Project Costs


  • National Bridge Inventory (NBI) Statistics
  • 14Number of bridges
  • 135ft / 41.1mTotal length
  • $286,000Total costs
  • 101,688Total average daily traffic
  • 1,134Total average daily truck traffic
  • National Bridge Inventory (NBI) Registered Bridges for Vinland
  • No street view available for this location

New bridges in Vinland, WI - historical statistics
  • New bridges - historical statistics
  • 31920-1929
  • 11930-1939
  • 11990-1999
  • 72000-2009
  • 22010-2019
Average Bridge Daily Traffic in Vinland, WI
Bridge Condition - Deck
  • Bridge Condition - Deck
  • 40.0%Very good
  • 20.0%Good
  • 20.0%Satisfactory
  • 20.0%Poor
Bridge Condition - Superstructure
  • Bridge Condition - Superstructure
  • 40.0%Very good
  • 20.0%Good
  • 20.0%Satisfactory
  • 10.0%Fair
  • 10.0%Poor
Bridge Condition - Substructure
  • Bridge Condition - Substructure
  • 50.0%Very good
  • 10.0%Good
  • 20.0%Satisfactory
  • 20.0%Poor
Bridge Condition - Channel
  • Bridge Condition - Channel
  • 14.3%Excellent
  • 42.9%Very good
  • 14.3%Good
  • 28.6%Satisfactory
Find on map >>   Show street view

Structure Number: B700155,  Location: 0.8M W JCT CTH T (Lat: 44.139550,  Lng: -88.598600),  Route carried "on" structure: County highway ,  Year Built: 1994,  Status: Open,  Structure Length: 1.16m (3.81ft),  Average Daily Traffic: 1,435 (year 2019),  Truck Traffic: 8%,  Average Future Daily Traffic: 1,578 (year 2040),  Design Load: HS 20,  Features Intersected: DAGGETS CREEK,  Facility Carried by Structure: CTH-G
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: County Highway Agency,  Approaching Roadway Width: 11.0m (36.1ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Channel: Good,  Operating Rating: 62.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B70021,  Location: TOWN OF MENASHA (Lat: 44.211567,  Lng: -88.475994),  Route carried "on" structure: City street ,  Year Built: 2001,  Status: Open,  Structure Length: 11.95m (39.21ft),  Average Daily Traffic: 2,500 (year 2021),  Average Future Daily Traffic: 1,310 (year 2040),  Design Load: HS 20,  Features Intersected: IH 41,  Facility Carried by Structure: LRD JACOBSON ROAD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 7,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 3 degrees,  Material/Design: Steel,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 3,  Length of Maximum Span: 44.2m (145.0ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 14.5m (47.6ft)

Condition: Deck: Good,  Superstructure: Satisfactory,  Substructure: Good,  Operating Rating: 70.2 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B700217,  Location: TOWN OF VINLAND (Lat: 44.096528,  Lng: -88.618511),  Route carried "on" structure: City street ,  Year Built: 2002,  Status: Open,  Structure Length: 7.73m (25.36ft),  Average Daily Traffic: 1,400 (year 2020),  Average Future Daily Traffic: 1,400 (year 2039),  Design Load: HS 20,  Features Intersected: USH 45,  Facility Carried by Structure: LRD BROOKS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 4 degrees,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 37.8m (124.0ft),  Curb-To-Curb Width: 10.4m (34.1ft),  Out-to-Out Width: 11.1m (36.4ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 86.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 42.1 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B70022,  Location: TOWN OF VINLAND (Lat: 44.100903,  Lng: -88.624161),  Route carried "on" structure: City street ,  Year Built: 2002,  Status: Open,  Structure Length: 8.13m (26.67ft),  Average Daily Traffic: 500 (year 2020),  Average Future Daily Traffic: 500 (year 2039),  Design Load: HS 20,  Features Intersected: USH 45,  Facility Carried by Structure: LRD SKELETON BRIDG
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Owner: State Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 3 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 40.5m (132.9ft),  Curb-To-Curb Width: 10.3m (33.8ft),  Out-to-Out Width: 11.2m (36.7ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 68.6 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 34.0 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present minimum criteria,  Underclear: Somewhat better than minimum adequacy,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: September 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B700234,  Location: TOWN OF VINLAND (Lat: 44.096917,  Lng: -88.621650),  Route carried "on" structure: City street ,  Year Built: 2002,  Status: Open,  Structure Length: 0.84m (2.76ft),  Average Daily Traffic: 153 (year 2019),  Average Future Daily Traffic: 168 (year 2039),  Design Load: HS 20,  Features Intersected: DAGGETS CREEK,  Facility Carried by Structure: LRD BROOKS RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 2 degrees,  Material/Design: Concrete continuous,  Design/Construction: Culvert,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 3.7m (12.1ft)

Condition: Channel: Excellent,  Culverts: Good,  Operating Rating: 53.9 metric tons,  Method Used To Determine Operating Rating: Field evaluation and documented engineering judgment,  Inventory Rating: 32.4 metric tons,  Method Used To Determine Inventory Rating: Field evaluation and documented engineering judgment,  Structural Evaluation: Better than present minimum criteria,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete
Find on map >>   Show street view

Structure Number: B70028,  Location: 0.3M E OF CTH R (Lat: 43.893617,  Lng: -88.497800),  Route carried "on" structure: City street ,  Year Built: 2009,  Status: Open,  Structure Length: 1.19m (3.90ft),  Average Daily Traffic: 610 (year 2020),  Average Future Daily Traffic: 622 (year 2039),  Design Load: HS 25 or greater,  Features Intersected: VAN DYNE CREEK,  Facility Carried by Structure: LRD LONE ELM RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 10.4m (34.1ft),  Skew: 3 degrees,  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 11.0m (36.1ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 9.1m (29.9ft)

Condition: Deck: Good,  Superstructure: Good,  Substructure: Very good,  Channel: Very good,  Operating Rating: 62.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 37.3 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Better than present minimum criteria,  Deck Geometry: Somewhat better than minimum adequacy,  Waterway Adequacy: Superior to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: B700287,  Location: AT USH 41 (Lat: 44.112397,  Lng: -88.521328),  Route carried "on" structure: County highway ,  Year Built: 2014,  Status: Open,  Structure Length: 6.81m (22.34ft),  Average Daily Traffic: 940 (year 2021),  Average Future Daily Traffic: 600 (year 2040),  Design Load: HL 93,  Features Intersected: IH 41,  Facility Carried by Structure: CTH GG
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Owner: State Highway Agency,  Approaching Roadway Width: 12.2m (40.0ft),  Skew: 34 degrees,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 2,  Length of Maximum Span: 33.2m (108.9ft),  Curb or Sidewalk Widths: Left: 4.3m (14.1ft),  Right: 0.0m,  Curb-To-Curb Width: 12.2m (40.0ft),  Out-to-Out Width: 17.8m (58.4ft)

Condition: Deck: Very good,  Superstructure: Very good,  Substructure: Very good,  Operating Rating: 43.1 metric tons,  Method Used To Determine Operating Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Inventory Rating: 33.4 metric tons,  Method Used To Determine Inventory Rating: Load and Resistance Factor Rating (LRFR) rating reported by rating factor(RF) method using HL-93 loadings,  Structural Evaluation: Equal to present desirable criteria,  Deck Geometry: Equal to present desirable criteria,  Underclear: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 48 months,  Inspection Date: March 2021,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Monolithic Concrete,  Deck Protection: Epoxy Coated Reinforcing
Find on map >>   Show street view

Structure Number: P700051,  Location: 0.2M S JCT CTH D (Lat: 44.093583,  Lng: -88.820050),  Route carried "on" structure: City street ,  Year Built: 1926,  Status: Open,  Structure Length: 1.01m (3.31ft),  Average Daily Traffic: 90 (year 2019),  Average Future Daily Traffic: 99 (year 2039),  Design Load: HS 20,  Features Intersected: PUMPKINSEED CREEK,  Facility Carried by Structure: LRD RUSHFORD AVE
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.7m (22.0ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 9.6m (31.5ft),  Curb-To-Curb Width: 5.8m (19.0ft),  Out-to-Out Width: 6.8m (22.3ft)

Condition: Deck: Satisfactory,  Superstructure: Good,  Substructure: Satisfactory,  Channel: Very good,  Operating Rating: 42.5 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 25.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Equal to present minimum criteria,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present minimum criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: December 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: P700056,  Location: 1.2M S JCT CTH G (Lat: 44.121983,  Lng: -88.523350),  Route carried "on" structure: City street ,  Year Built: 1925,  Year Reconstructed: 1960,  Status: Open,  Structure Length: 0.85m (2.79ft),  Average Daily Traffic: 38 (year 2020),  Average Future Daily Traffic: 38 (year 2040),  Design Load: HS 20,  Features Intersected: NEENAH SLOUGH,  Facility Carried by Structure: LRD WOODENSHOE RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Stringer/Multi-beam,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 8.3m (27.2ft),  Curb-To-Curb Width: 8.5m (27.9ft),  Out-to-Out Width: 8.7m (28.5ft)

Condition: Deck: Poor,  Superstructure: Fair,  Substructure: Poor,  Channel: Satisfactory,  Operating Rating: 62.1 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 38.9 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Better than present minimum criteria,  Waterway Adequacy: Equal to present minimum criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.31m (4.30ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: October 2021,  Bridge Improvement Cost: $100,000,  Roadway Improvement Cost: $10,000,  Total Project Cost: $150,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: P700903,  Location: 0.2M S JCT CTH B (Lat: 44.121400,  Lng: -88.785133),  Route carried "on" structure: City street ,  Year Built: 1920,  Year Reconstructed: 1960,  Status: Open,  Structure Length: 0.73m (2.40ft),  Average Daily Traffic: 40 (year 2019),  Average Future Daily Traffic: 44 (year 2040),  Design Load: HS 20,  Features Intersected: LAKE POYGAN TRIB,  Facility Carried by Structure: LRD QUIGLEY RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 7.9m (25.9ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.7m (22.0ft),  Curb-To-Curb Width: 8.4m (27.6ft),  Out-to-Out Width: 8.6m (28.2ft)

Condition: Deck: Poor,  Superstructure: Poor,  Substructure: Poor,  Channel: Very good,  Operating Rating: 29.4 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 16.2 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Meets minimum limits,  Deck Geometry: Equal to present minimum criteria,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Length Of Structure Improvement: 1.19m (3.90ft),  Designated Inspection Frequency: Every 12 months,  Inspection Date: December 2021,  Bridge Improvement Cost: $91,000,  Roadway Improvement Cost: $9,000,  Total Project Cost: $136,000 ( Estimate for 2021),  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: P700905,  Location: 1.0M W JCT CTH T (Lat: 44.118667,  Lng: -88.603767),  Route carried "on" structure: City street ,  Year Built: 1930,  Year Reconstructed: 1965,  Status: Open,  Structure Length: 0.70m (2.30ft),  Average Daily Traffic: 82 (year 2020),  Average Future Daily Traffic: 83 (year 2039),  Design Load: HS 20,  Features Intersected: SKELTON CREEK,  Facility Carried by Structure: LRD MAXWELL RD
Minimum Vertical Clearance: 30+ m (98+ ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Owner: Town or Township Highway Agency,  Approaching Roadway Width: 6.1m (20.0ft),  Material/Design: Concrete,  Design/Construction: Slab,  Number Of Spans In Main Unit: 1,  Length of Maximum Span: 6.6m (21.7ft),  Curb-To-Curb Width: 6.0m (19.7ft),  Out-to-Out Width: 7.9m (25.9ft)

Condition: Deck: Satisfactory,  Superstructure: Satisfactory,  Substructure: Satisfactory,  Channel: Satisfactory,  Operating Rating: 31.0 metric tons,  Method Used To Determine Operating Rating: Load Factor (LF),  Inventory Rating: 17.8 metric tons,  Method Used To Determine Inventory Rating: Load Factor (LF),  Structural Evaluation: Somewhat better than minimum adequacy,  Deck Geometry: Meets minimum limits,  Waterway Adequacy: Equal to present desirable criteria,  Approach Roadway Alignment: Equal to present desirable criteria,  Designated Inspection Frequency: Every 24 months,  Inspection Date: October 2020,  Deck Structure Type: Concrete Cast-file-Place,  Wearing Surface/Protective System: Wearing Surface: Bituminous
Find on map >>   Show street view

Structure Number: B700217,  Location: 1.5M N JCT USH 41 (Lat: 44.096528,  Lng: -88.618511),  Route carried "under" structure: US 45,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 17,000 (year 2020),  Features Intersected: USH 45,  Facility Carried by Structure: LRD BROOKS RD
Minimum Vertical Clearance: 5.17m (16.96ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete continuous,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 37.8m (124.0ft)

Find on map >>   Show street view

Structure Number: B70022,  Location: 2.6M N JCT USH 41 (Lat: 44.100903,  Lng: -88.624161),  Route carried "under" structure: US 45,  Year Built: 2002,  Structure Length: 0. m,  Average Daily Traffic: 17,000 (year 2020),  Truck Traffic: 6%,  Features Intersected: USH 45,  Facility Carried by Structure: LRD SKELETON BRIDG
Minimum Vertical Clearance: 5.31m (17.42ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 4,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 40.5m (132.9ft)

Find on map >>   Show street view

Structure Number: B700287,  Location: AT CTH GG (Lat: 44.112397,  Lng: -88.521328),  Route carried "under" structure: Interstate 41,  Year Built: 2014,  Structure Length: 0. m,  Average Daily Traffic: 59,900 (year 2021),  Features Intersected: IH 41,  Facility Carried by Structure: CTH GG
Minimum Vertical Clearance: 5.15m (16.90ft),  Kilometerpoint: 0.000,  Lanes on structure: 2,  Lanes under structure: 6,  Material/Design: Prestressed concrete,  Design/Construction: Stringer/Multi-beam,  Length of Maximum Span: 33.2m (108.9ft)